• Title/Summary/Keyword: 조사선량율

Search Result 509, Processing Time 0.023 seconds

Calculation of the Air-Scattering Dose Rate by the Single Scattering Approximation (단일산란근사법(單一散亂近似法)에 의한 공기중(空氣中) 산란방사선량(散亂放射線量)의 계산(計算))

  • Yook, Chong-Chul;Ha, Chung-Woo;Lee, Jai-Ki;Moon, Philip S.
    • Journal of Radiation Protection and Research
    • /
    • v.4 no.1
    • /
    • pp.21-28
    • /
    • 1979
  • A calculation is presented of air-scattered gamma rays using the modified single-scattering approximation. The air-scattered tissue dose rates are calculated for a general purpose taking into account (a) the buildup and exponential attenuation, (b) the energy spectrum at the position of question and (c) the geometrical scattering volume in three dimensions. These calculations have been further modified to render them applicable to a typical field irradiation facility which is surrounded by a shield wall and in which the source is fitted with a beam collimating device. The results of the calculation include the energy spectra, angular distribution and tissue does rates at source-receiver separation distances of from 35m to 300m. The comparison shows that the present method developed may be generally adequate for the gamma-ray air-scattering problems in field irradiation facilities if energy and angular distribution at the shield are unimportant.

  • PDF

Textural and Sensory Characteristics of Gamma Irradiated Porridges (감마선 조사된 시판 분말죽의 물성 및 관능특성)

  • 육홍선;이유석;이주운;오상희;김장호;김동수;변명우
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.33 no.2
    • /
    • pp.427-432
    • /
    • 2004
  • Effect of gamma irradiation on porridge viscosity was studied. Vegetable, beef and pine nut dry flour porridges were irradiated at 0, 2.5, 5, 7.5 and 10 kGy, and rheological characteristics and sensory qualities of irradiated porridge were evaluated. Hunter color lightness were decreased, while redness were increased in dry flour porridge with the increase of irradiation dose. Firmness, consistency, cohesiveness and viscosity of dry flour porridge were significantly decreased with the increase of irradiation dose (p<0.05). Vegetable, beef and pine nut dry flour porridges at dose of 10 kGy reduced the viscosity with 93%, 71% and 55%, respectively Irradiation greatly reduced the viscosity of porridges, probably by starch depolymerization. Irradiation increased the total solids and thus, can improve the calorie up to 30 ㎉. Gamma irradiation was effective in enhancing calorie value of porridge due to reduction of viscosity. As a result of sensory evaluation, overall acceptability and the quality characteristics of irradiated porridges (up to S kGy) were not significantly different from those of the control (p<0.05). In the vegetable porridge, the irradiated porridge at dose of 2.5 kGy was a significantly better overall acceptability than the non-irradiated porridge (p<0.05).

Absorbed Dose for the Endovascular Ho-166-DTPA Brachytherapy Using a Balloon Angio Catheter (풍선도자관의 Ho-166-DTPA 흡수선량)

  • 조철우;박찬희;윤석남;강해준;김미화;장지선;박경배
    • Progress in Medical Physics
    • /
    • v.13 no.2
    • /
    • pp.98-103
    • /
    • 2002
  • The purpose of this study was to evaluate the absorbed dose to the coronary artery segment from various sized balloon angio catheters. The liquid form of Ho-166 was produced at the KAERI by (n, ${\gamma}$ ) reaction. We used GafChromic film for the estimation of the absorbed dose by beta particles. The exposed films were read using a videodensitometer. Several film exposures were made with varying irradiation times and activities. A modified micrometer was used for the measurement of the absorbed dose distribution near the balloon surface. Four balloons of coronary catheters evaluated were 30 m long and 2.5, 3.0, 3.5 and 4.0 mm in diameter. All doses are plotted in units of Gy/min/GBq/ml as a function of radial distance in mm from the surface of balloon. The absorbed dose rate was 0.86, 1.01, 1.11 and 1.24 Gy/min/GBq/ml at a balloon surface for various balloon diameter 2.5, 3.0, 3.5 and 4.0 mm respectively. Using a vacuum pump, the air in the balloon was evacuated prior to instillation of the Ho-166 source. By removing air bubbles in the balloon, the absorbed dose distribution was more uniform.

  • PDF

Development of the EGS4 Control Code to Calculate the Dose Distributions in a Strong Magnetic Field (자기장이 인가된 물팬텀 속의 전자선 선량분포 계산을 위한 EGS4 제어코드의 개발과 응용)

  • 정동혁;오영기;신교철;김진기;김기환;김정기;이강규;문성록;김성규
    • Progress in Medical Physics
    • /
    • v.14 no.1
    • /
    • pp.1-7
    • /
    • 2003
  • In this work we developed a EGS4 control code to calculate the dose distributions for high energy electron beams in water phantom applied longitudinal magnetic field. We reviewed the electron's motion in magnetic field and delivered equations for direction changs of the electron by the external magnetic field. The mathematical results are inserted into the EGS4 code system to account for the presence of external magnetic fields in phantom. The electron pencil beam paths of 6 MeV in water phantom are calculated for magnetic fields of 1-3 T and the dose distributions for a field of 1.0 cm in diameter are calculated for magnetic fields of 0.6-1 T using the code. From the results of path calculations we found that the lateral ranges of the electrons are reduced in the magnetic field of 3 T. For a field of 1 cm diameter and a magnetic field of 1 T, the small dose enhancement near the range of the electrons on the depth dose and the penumbra reduction of 0.15 cm on the beam profile are observed. We discussed and evaluated the results from the theoretical concepts.

  • PDF

Feasibility Study of Parallel- Plate Detector Using Dielectric film for 6 MV X-ray (6MV X-선 검출특성 조사를 위하여 유전체 필름을 이용하여 제작한 평행판 검출기의 유용성)

  • 조문준;김용은;이병용;김정기;임상욱;김현수;김기환
    • Progress in Medical Physics
    • /
    • v.15 no.2
    • /
    • pp.105-111
    • /
    • 2004
  • The parallel plate detector with dielectric film for dosimetry was designed to measure detection characteristic of 6 MV X-ray with medical linear accelerator. PTFE film was inserted into FEP films that are made by two one-side metal coated materials for ion source. The thicknesses of PTFE dielectric film was 100 ${\mu}{\textrm}{m}$ and the thickness of FEP dielectric film was 100 ${\mu}{\textrm}{m}$, respectively. This detector was fixed by two acrylic plate for physical hardness ad geometrical consistency. The geometrical condition for measurement with parallel-plate for detector was below; SSD=100 cm and the 5 cm depth between detector and phantom surface The major parameter of detector characteristics such as zero drift current, leakage current, charge response by applied voltage, reproducibility, linearity, TMR measurement, dose rate effect were measured. The zero drift currents are 8.3 pA and leakage currents are 10 pA. The charge response of applied voltage is showing linearity in 414 voltage. The measurement deviation of reproducibility in this detector is within 1% for dose and the linearity of applied dose shows in this detector. The TMR curves in phantom between this parallel plate detector and reference detector are matched within 3% deviation from maximum dose depth to 7.5 cm depth. It is considered that this dosimetric system is satisfactory for the purpose of the constancy check of the 6 MV x-ray from medical linear accelerator.

  • PDF

Interstitial Vaginal Needle Implantation in Gynecological Tumors : Design and Construction of Applicator (부인과암에서 조직내 삽입 방사선치료 - Applicator의 고안 및 제작-)

  • Kang, Seung-Hee;Chun, Mi-Son;Kang, Hae-Jin;Jung, Chil;Son, Jeong-Hyae
    • Radiation Oncology Journal
    • /
    • v.16 no.2
    • /
    • pp.167-175
    • /
    • 1998
  • Purpose : It is not a simple task to achieve the ideal isodose curve with a standard vaginal applicator or sing1e plane needle impant in the paravaginal tissue when primary or recurrent gynecological neoplasms(cervical cancers, vaginal cancers and vulvar cancers) are treated as a boost following external beam radiotherapy. The authors introduce the development and construction of a simple, inexpensive, customized applicator for volume implant to maximize the radiation dose to the tumor while minimizing the dose to the rectum and the bladder. Materials and Methods : Nine patients underwent Ir-192 transperineal interstitial implantation for either recurrent(5 cases) or primary(3 cases) cervical cancers or primary vaginal cancer(1 case) between August 1994 and February 1998 at Ajou university hospital. First 3 cases were performed with a sing1e plane implant guided by digital palpation. Because of inadequate isodose coverage in the tumor volume in first 3 cases, we designed and constructed interstitial vaginal applicator for volume implant to improve tumor dose distribution and homogeneity while sparing the surrounding normal tissue. Our applicators consist of vaginal obturator and perineal template that made of the clear acrylamide and dental mold material$(Provil^{(R)})$. The applicators were customized individually according to the tumor size and its location Both HDR and LDR irradiation were given with these applicators accomodating 6 Fr needles(Microselectron Nucletron). The pretreatment planning prior to actual implant was performed whenever possible. Results : Needles can be inserted easily and evenly into the tumor volume through the holes of templates, requiring less efforts and time for the implant procedure. Our applicators made of materials available from commercial vendors. These have an advantage that require easy procedure, and spend relatively short time to construct. Also it was possible to fabricate applicators to individualize according to the tumor size and its location and to achieve the ideal isodose coverage. We found an accurate needle arrangement and ideal dose distribution through the CT scan that was obtained in 3 cases after needle implant. Three patients with primary cervical and vaginal cancers were controlled locally at final follow up. But all recurrent cases failed to do so. Conclusion : The authors introduce inexpensive, simple interstitial vaginal templates which were self-designed and constructed using materials available from commercial vendors such as acrylanide and dental mold material $(Provil^{(R)})$.

  • PDF

3D-Conformal Radiotherapy for Head and Neck Cancers at Asan Medical Center (두경부종양에서 3차원 입체조형치료의 서울아산병원 경험)

  • Lee Sang-Wook;Chang Hye-Sook;Ahn Seung-Do;Yi Byong-Yong;Choi Eun-Kyung;Nho Young-Ju;Back Geum-Mun;Kim Jong-Hoon
    • Korean Journal of Head & Neck Oncology
    • /
    • v.21 no.2
    • /
    • pp.151-157
    • /
    • 2005
  • 목적: 다양한 발생부위에서 발생한 두경부종양을 대상으로 3차원 입체조형치료를 시도하여 표적체적 내 선량균일성과 주변장기의 선량분포변하를 알아보고자 하였다. 대상 및 방법: 1995년 1월부터 1996년 12월까지 3차원 입체조형치료를 시행 받은 38명에 분석을 시행하였다. 3차원 입체조형 치료는 동일평면 또는 비동일평면상에서 4개에서 14개의 조사면 수로 시행되었다. 3차원 입체조형치료계획시 표적 체적에 $50{\sim}82Gy$의 선량을 처방하였고, 이하선 안구, 척수, 측두하악관절 등을 보호하고자 하였다. 3차원 입체조형치료 계획을 기존의 2차원 치료계획과 비교하기 위하여 표적체적과 주변정상자기의 선량체적히스토그램, 평균선량, 표적체적 내에서 처방선량의 $95{\sim}105%$의 선량이 분포하는 체적을 비교하였다 치료계획에서 실제 치료시까지 소용되는 비용효과를 비교하였다. 대상환자의 평균추적기간은 34개월이었다. 결 과: 3차원 입체조형시료는 2차원 치료에 비해서 표적체적내 평균선량이 평균 10% 증가하였고, 주변정장기에 조사되는 방사선량이 현저히 감소됨을 관찰할 수 있었고 표적체적에 대한 등선량 곡선 분포가 우수함을 관찰할 수 있었다. 결 론: 3차원 입체조형치료는 두경부종양에서 표적체적의 선량 균일성이 증가하였고, 주변장기의 보존이 가능할 것으로 생각되었다. 따라서 본 저자들은 3차원 입체조형치료가 두경부종양에서 국소제어율과 무질병생존율 향상에 기여할 것으로 생각하였다.

Effects of Gamma Irradiation on the Content of β-Carotene in Jeju Orange, Vitamin D3 in Anchovy and α-Tocopherol in Beef (방사선 조사에 의한 감귤의 β-Carotene, 멸치의 비타민 D3 및 쇠고기의 α-Tocopherol의 함량변화)

  • Kim, Shin-Hee;Yook, Hong-Sun;Byun, Myung-Woo;Chung, Young-Jin
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.34 no.7
    • /
    • pp.1071-1076
    • /
    • 2005
  • Gamma irradiation treatment brings about biochemical changes that could affect nutritional Quality of food. This study was conducted to examine the content of $\beta-Carotene$ in Jeju orange, vitamin $D_3$ in anchovy and $\alpha-Tocopherol$ in beef. $\beta-Carotene$ content of Jeju orange was not affected by irradiation of 5 and 10kGy. In anchovy, vitamin $D_3$ content was dose-dependently increased to $109.30\%\;and\;125.25\%$ of original content by irradiation of 5 and 10kGy, respectively. $\alpha-Tocopherol$ content in beef with high fat was progressively reduced by $17\%$ of original value with irradiation of 1kGy and by $84\%$ with 10kGy. It could be concluded that $\alpha-tocopherol$ might be most vulnerable to irradiation, while vitamin $D_3$ is very stable against irradiation within 10kGy of gamma irradiation.

A Study on the Effect of Field Shaping on Dose Distribution of Electron Beams (전자선의 선량분포에 있어서 Field Shaping의 효과에 관한 연구)

  • Kang, Wee-Saing;Cho, Moon-June
    • Radiation Oncology Journal
    • /
    • v.4 no.2
    • /
    • pp.165-172
    • /
    • 1986
  • In electron therapy, lead cutout or low-melting alloy block is used for shaping the field. Material for shaping electron field affects the output factor as wet 1 as the collimation system. The authors measured the output factors of electron beams for shaped fields from Clinac-18 using ionization chamber of Farmer type in polystyrene phantom. They analyzed the parameters that affect the output factors. The output factors of electron beams depend on the incident energy, collimation system and size of shaped field. For shaped field the variation of output factor for the field size (A/P) has appearence of a smooth curve for all energy and all applicator collimator combination. The output factors for open field deviate from the curves for shaped fields. An output factor for a given field can be calculated by equivalent field method such as A/P method, if a combination of applicator and collimator is fixed.

  • PDF