• Title/Summary/Keyword: 조명시스템

Search Result 2,635, Processing Time 0.031 seconds

A Study on the SVC System Stabilization Using a Neural Network (신경회로망을 이용한 SVC 계통의 안정화에 관한 연구)

  • 정형환;허동렬;김상효
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.3
    • /
    • pp.49-58
    • /
    • 2000
  • This paper deals with a systematic approach to neural network controller design for static VAR compensator (SVC) using a learning algorithm of error back propagation that accepts error and change of error as inputs, the momentum learning technique is used for reduction of learning time, to improve system stability. A SVC, one of the Flexible AC Transmission System(FACTS), constructed by a fixed capacitor(FC) and a thyristor controlled reactor(TCR), is designed and implemented to improve the damping of a synchronous generator, as well as controlling the system voltage.TO verify the robustness of the proposed method, we considered the dynamic response of generator rotor angle deviation, angular velocity deviation and generator terminal voltage by applying a power fluctuation and rotor angle fluctuation in initial point when heavy load and normal load. Thus, we prove the usefulness of proposed method to improve the stability of single machine-infinite bus with SVC system.

  • PDF

The Characteristics of Exhaust Gas in Diesel Engine by Corana Discharge-EGR System (코로나 방전-EGR 조합시스템에 의한 디젤기관의 배기 가스 특성)

  • Park, Jae-Yoon;Jung, Jang-Gun;Kim, Jong-Suk;Ha, Hyun-Jin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.7
    • /
    • pp.39-44
    • /
    • 2005
  • A great part of flint fuel is Hydrogen and carbon's combination, they should be generated steam and carbon gas when combine with oxygen for perfect combustion in the inside of engine but, the pollutive material are discharged, even though perfect combustion condition especially $NO_x$ and Smoke. they are really harmful for health. In this paper was shown the result of discharging gas' reduction quality. which used combination of corona discharge using the high voltage source of common frequency with EGR. $NO_x$ is increased in entire load erea in proportion to increasing of EGR rate and impression voltage. Smoke is increased slowly under 75[%] in load rate but it is increased rapidly in entire load erea and the reduction rate of Smoke is increased in proportion to increasing of impression voltage.

Design of the Small BPF for Wireless Communication Systems (무선통신용 초소형 대역통과 필터의 설계)

  • Hwang, Jae-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.7
    • /
    • pp.26-31
    • /
    • 2005
  • In this paper, a small BPF(band pass filter) is designed using new probe type for wireless communication system. The dielectric resonator is used high Q ceramics for low loss characteristic. In order to provide a band pass filter which can be reduced in dimension, can be reduced in height, and can be surface-mounted. The filter was fabricated using $TE_{01{\delta}}$ mode dielectric resonator. The input/output probes are attached to coner portion of the rectangular metal cavity. Results of the manufactured filter($12{\times}12{\times}8[mm]$) show that the center frequency is 9.95358[GHz], the insertion loss is -1.9[dB], the 3[dB]_bandwidth is 14.9[MHz], and the loaf Q is 664.

Effect of Glazing Systems on Chromaticity and Color Temperature in the Office Room (투과체에 적용된 채광방식이 사무소공간의 색도 및 색온도분포에 미치는 영향 분석)

  • Jeong, In-Young;Kim, Jeong-Tai
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.3
    • /
    • pp.18-26
    • /
    • 2007
  • One basic function of glazing system has always been the maintenance of visual contact with the natural environment-a fundamentally ecological function. In addition, penetration light through glazing system have an effect on variable atmosphere of interior. In this study, a typical office space was selected as a evaluation model and a 1/10 scale model was made. The conventional window, differentiated window and interior lightshelf were designed to enhance daylighting performance. The chromaticity and color temperature of interior space was measured using Prometric 1421. The result showed that transmittance by wavelength range of the glazing had an effect on chromaticity and color temperature. Also, color temperature of indoor environment were increased by $5{\sim}20[%]$ using differentiated window and interior lightshelf. Accordingly, it is thought that the use of a daylighting system will create activate indoor atmosphere.

Faults Current Discrimination of Power System Using Wavelet Transform (웨이블렛 변환을 이용한 전력시스템 고장전류의 판별)

  • Lee, Joon-Tark;Jeong, Jong-Won
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.3
    • /
    • pp.75-81
    • /
    • 2007
  • Recently the subject of "wavelet analysis" has be drawn by both mathematical and engineering application fields such as Signal Processing, Compression/Decomposition, Wavelet-Neural Network, Statistics and etc. Even though its similar to Fourier analysis, wavelet is a versatile tool with much mathematical content and great potential for applications. Especially, wavelet transform uses localizable various mother wavelet functions in time-frequency domain. Therefore, wavelet transform has good time-analysis ability for high frequency component, and has good frequency-analysis ability for low frequency component. Using the discriminative ability is more easy method than other conventional techniques. In this paper, Morlet wavelet transform was applied to discriminate the kind of line fault by acquired data from real power transformation network. The experimental result presented that Morlet wavelet transform is easier, and more useful method than the Fast Fourier Transform(FFT).

The Online Protective Coordination Schemes of the Distribution Systems with Distributed Generation (분산전원이 연계된 배전계통의 온라인 보호협조 방안)

  • Choi, Joon-Ho;Ro, Kyoung-Soo;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.3
    • /
    • pp.132-141
    • /
    • 2007
  • Recently, there has been growing interest in distributed resources with high-energy efficiency due to the increasing energy consumption and environmental pollution problems. But an insertion of new distributed generation to existing power distribution systems can cause several problems such as voltage variations, harmonics, protective coordination, increasing fault current etc. In this paper, a new method of the fault location identification at the distribution system with distributed resources, which can be determined by the magnitude and direction of the fault current, is proposed. In addition, a new online protective coordination scheme of recloser-sectionalizer is proposed based on the proposed fault location identification method for distribution system with distributed resources.

Transient Grounding Impedance Characteristics of a Copper Rod-type Grounding Electrode used for Electric Distribution Systems Using EDSA Program (EDSA 프로그램을 이용한 배전계통에 사용되는 동봉 접지전극의 과도 접지임피던스 특성)

  • Kim, Kyung-Chul;Oh, Kyung-Hoon;Kim, Min-Sung;Choi, Jong-Kee;Kim, Dong-Myung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.8
    • /
    • pp.26-32
    • /
    • 2009
  • Grounding insures a reference potential point for electric devices and also provides a law resistance path for fault or transient currents in the earth. The ground impedance as a function of frequency is necessary for determining its performance since fault or transient currents could contain a wide range of frequencies. A copper rod electrode is the most commonly used grounding electrode in electric distribution systems. In this paper, the grounding impedance of copper rods has been measured in frequency raging from 60[Hz] up to 100 [kHz] and an equivalent model of the grounding impedance is identified from the measured values. The grounding impedance under study when a typical lightning surge is injected into the grounding system was simulated numerically and graphically through the use of the EDSA software program.

A experimental Study on the Reinforced Coil Development for the Efficiency Improvement of a Single Phase Induction Motor (단상유도전동기의 효율 개선을 위한 강화코일 개발에 관한 실험적 연구)

  • Lee, Jong-Myong;Kim, Nam-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.1
    • /
    • pp.78-84
    • /
    • 2010
  • The efficiency of system with a built-in coil is improved as (1) the total coil flux increases, (2) the space distribution of coil flux is closer to the sinusoidal wave and (3) the direction of coil flux flow becomes more inherent with the original direction at the same condition. Every turn RC(Reinforced Coil) is composed of OC having original region and two IC's strengthening bidirectionally the inner part flux in order to maintain the symmetry with origin. This way we will realize the inherent flux direction and the sinusoidal closeness as well. Accordingly RC type is obtained by connecting the pure OC's and RC's in just turns to be closer to sinusoidal flux wave. We proved experimentally the usefulness of reinforced coil to improve the efficiency of SPIM.

HIPI Controller of IPMSM Drive using ALM-FNN (ALM-FNN을 이용한 IPMSM 드라이브의 HIPI 제어기)

  • Ko, Jae-Sub;Choi, Jung-Sik;Chung, Dong-Hwa
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.8
    • /
    • pp.57-66
    • /
    • 2009
  • The conventional fixed gain PI controller is very sensitive to step change of command speed, parameter variation and load disturbances. The precise speed control of interior permanent magnet synchronous motor(IPMSM) drive becomes a complex issue due to nonlinear coupling among its winding currents and the rotor speed as well as the nonlinear electromagnetic developed torque. Therefore, there exists a need to tune the PI controller parameters on-line to ensure optimum drive performance over a wide range of operating conditions. This paper proposes hybrid intelligent-PI(HIPI) controller of IPMSM drive using adaptive learning mechanism(ALM) and fuzzy neural network(FNN). The proposed controller is developed to ensure accurate speed control of IPMSM drive under system disturbances and estimation of speed using artificial neural network(ANN) controller. The PI controller parameters are optimized by ALM-FNN at all possible operating condition in a closed loop vector control scheme, The validity of the proposed controller is verified by results at different dynamic operating conditions.

High Performance Control of Induction Motor Drive using Multi Adaptive Fuzzy Controller (다중 적응 퍼지제어기를 이용한 유도전동기 드라이브의 고성능 제어)

  • Ko, Jae-Sub;Choi, Jung-Sik;Chung, Dong-Hwa
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.10
    • /
    • pp.59-68
    • /
    • 2009
  • The field oriented control of induction motors is widely used in high performance applications. However, detuning caused by parameter disturbance still limits the performance of these drives. In order to accomplish variable speed operation, conventional PI-like controllers are commonly used. These controllers provide limited good performance over a wide range of operation, even under ideal field oriented conditions. This paper is proposed high performance control of induction motor drive using multi adaptive fuzzy controller. This controller has been performed for speed control with fuzzy adaptation mechanism (FAM)-PI, current control with model reference adaptive fuzzy control(MFC) and estimation of speed using ANN. The proposed control algorithm is applied to induction motor drive system using FAM-PI, MFC and ANN controller. The performance of proposed controller is evaluated by analysis for various operating conditions using parameters of induction motor drive. Also, this paper is proposed the analysis results to verify the effectiveness of this controller.