• Title/Summary/Keyword: 제조방법

Search Result 6,547, Processing Time 0.038 seconds

A study of the antifungal properties and flexural strength of 3D printed denture base resin containing titanium dioxide nanoparticles (이산화티타늄 나노입자를 함유한 3D 프린팅 의치상 레진의 항진균성 및 굽힘 강도에 대한 연구)

  • Seok-Won Yoon;Young-Eun Cho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.2
    • /
    • pp.95-103
    • /
    • 2024
  • Purpose. With the advancement of digital technology, 3D printing is being utilized in the fabrication of denture base. Nevertheless, increasing microbial adhesion to the surface of denture base has been reported as the disadvantage of 3D-printed denture base. The purpose of this study is to investigate the antifungal properties and flexural strength of 3D-printed denture base resin according to the different contents of titanium dioxide nanoparticles. Materials and methods. Titanium dioxide nanoparticles were mixed with the 3D printing resin at the ratios of 0.5, 1, 1.5, and 2 wt%. Twenty specimens per each group were printed in the form of cylindrical shape (diameter: 20 mm, height: 3 mm) to evaluate antifungal properties. Ten specimens from each group underwent polishing using autogrinder, while the remaining ten specimens did not. Candida albicans in hyphae form was inoculated onto each specimen, optical density and colony-forming unit were analyzed. The surface of the specimen was observed using scanning electron microscopy. To evaluate the flexural strength, twenty specimens per each group were 3D printed in the form of rectangular prism shape (length: 64 mm, height: 10 mm, width: 3 mm) and three-point bending tests were conducted using universal testing machine according to ISO 20795-1. Results. Colony-forming unit of C.albicans and optical density of culture medium showed no difference between non-polished groups, but decreased in the polished groups at concentration of 1, 1.5, 2 wt% titanium dioxide nanoparticles. Flexural strength increased with titanium dioxide nanoparticle at concentration of 0.5, 1, 1.5 wt%, but decreased at 2 wt% compared to 1.5 wt%. Conclusion. When 1.5 wt% of titanium dioxide nanoparticles were added to the 3D-printed denture base resin with polishing, antifungal properties were increased.

The Effect of Empathy Value of Chinese Female University Students on Affection with Sustainable Fashion Products on Affection and Purchase Intention (중국 여대생의 지속가능한 패션제품에 대한 공감가치가 호감도와 구매의사에 미치는 영향)

  • Yi-Fei Wu;Young-Sook Lee
    • Journal of Internet of Things and Convergence
    • /
    • v.10 no.3
    • /
    • pp.35-48
    • /
    • 2024
  • This study analyzed the value empathy of environmentally sustainable fashion products, encompassing environmental, economic, and social values, drawing from existing literature. We sought to verify the relationship between empathic value and the likability and purchase intention towards these products. To validate these relationships, we formulated research hypotheses and conducted an online survey targeting female college students residing in Guangzhou, Guangdong Province, China, who have experience purchasing environmentally sustainable fashion products. The survey was conducted from August 10th to August 20th, 2023, with a total distribution of 352 questionnaires. Among the collected responses, 313 valid responses were utilized for data analysis. The collected survey data underwent frequency analysis, exploratory factor analysis, reliability and validity analysis, correlation analysis, and multiple regression analysis using SPSS 26.0 software. The analysis yielded the following results. First, the empathy value of environmentally sustainable fashion products was classified into environmental protection values, economic values, and social values. Second, the economic and social values of environmentally sustainable fashion products were found to have a positive effect on favorability. Third, it was found that the environmental protection value and social value of environmentally sustainable fashion products had a positive effect on purchase intention. Fourth, it was found that Chinese female college students' favorability toward environmentally sustainable fashion products had a positive effect on their purchase intention. Based on these results, it is judged that companies need to emphasize the characteristics of products such as environmental protective value, economic value, and social value in order to promote consumers' purchase of environmentally sustainable fashion products. The purpose of this study is to help develop marketing strategies for environmentally sustainable fashion products by providing basic data, development ideas, and methods useful for environmentally sustainable fashion-related industries and companies by analyzing the relationship between empathy value, favorability, and purchase intention.

Evaluation on Growth Characteristics of Red Pepper (Capsicum annuum L.) and Soil Chemical Properties by Continuous Application of Food Waste Compost with Manure (음식물류폐기물 혼합 가축분 퇴비 연용에 따른 고추(Capsicum annuum L.) 생육 및 토양 화학적 특성 평가)

  • Jin-Ju Yun;Young-Jae Jeong;Seong-Heon Kim;Sang-Ho Jeon;Ahn-Sung Roh;Soon-Ik Kwon;Yu-Na Lee;Jae-Hong Shim
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.32 no.3
    • /
    • pp.31-41
    • /
    • 2024
  • Food waste compost with high salt content produced by aerobic digestion, but concerns about application of cropland. To address this issue, food waste is being composted by mixing it with livestock manure, which has a lower salt content. Therefore, this study aimed to evaluate the growth characteristics of red pepper and soil chemical properties for continuous application with different amounts of food waste compost with manure (FWC). Treatments were consisted of no fertilizer (NF), inorganic fertilizer (N-N-P2O5-K2O, 19.0-11.2-14.9 kg 10a-1), and inorganic fertilizer + food waste compost with manure (NPKFWC). FWC treatment was applied at three treatment rates based on soil organic matter content: 900 kg 10a-1, 1,800 kg 10a-1, and 2,700 kg 10a-1 ( referred to a s FWC 1, 2, 3 , respectively). As a r esult of the red pepper yield was about 1.8 times higher in NPKFWC 1 and NPKFWC 2 than that in the NF, but decreased in the NPKFWC 3, 300% of the recommended FWC application rate. Yield decreased in all FWC treatments with continuous application for three year and also decreased about 40% from 3,265 kg 10a-1 in the first year to 1,948 kg 10a-1 in the third year. For the soil chemical properties, the content of soil organic matter, available P2O5, and exchangeable cations increased in the FWC treatments, and were higher than the NF. Exchangeable sodium in all treatments was increased slightly compared to the soil before used, and no significant salinization was observed in the FWC. This study confirmed that excessive use of FWC not only reduced nutrient use efficiency, but also decreased the red pepper yield. Therefore, it is concluded that optimum usage of FWC is effective for agroecological impacts.

An accuracy analysis of Cyberknife tumor tracking radiotherapy according to unpredictable change of respiration (예측 불가능한 호흡 변화에 따른 사이버나이프 종양 추적 방사선 치료의 정확도 분석)

  • Seo, jung min;Lee, chang yeol;Huh, hyun do;Kim, wan sun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.157-166
    • /
    • 2015
  • Purpose : Cyber-Knife tumor tracking system, based on the correlation relationship between the position of a tumor which moves in response to the real time respiratory cycle signal and respiration was obtained by the LED marker attached to the outside of the patient, the location of the tumor to predict in advance, the movement of the tumor in synchronization with the therapeutic device to track real-time tumor, is a system for treating. The purpose of this study, in the cyber knife tumor tracking radiation therapy, trying to evaluate the accuracy of tumor tracking radiation therapy system due to the change in the form of unpredictable sudden breathing due to cough and sleep. Materials and Methods : Breathing Log files that were used in the study, based on the Respiratory gating radiotherapy and Cyber-knife tracking radiosurgery breathing Log files of patients who received herein, measured using the Log files in the form of a Sinusoidal pattern and Sudden change pattern. it has been reconstituted as possible. Enter the reconstructed respiratory Log file cyber knife dynamic chest Phantom, so that it is possible to implement a motion due to respiration, add manufacturing the driving apparatus of the existing dynamic chest Phantom, Phantom the form of respiration we have developed a program that can be applied to. Movement of the phantom inside the target (Ball cube target) was driven by the displacement of three sizes of according to the size of the respiratory vertical (Superior-Inferior) direction to the 5 mm, 10 mm, 20 mm. Insert crosses two EBT3 films in phantom inside the target in response to changes in the target movement, the End-to-End (E2E) test provided in Cyber-Knife manufacturer depending on the form of the breathing five times each. It was determined by carrying. Accuracy of tumor tracking system is indicated by the target error by analyzing the inserted film, additional E2E test is analyzed by measuring the correlation error while being advanced. Results : If the target error is a sine curve breathing form, the size of the target of the movement is in response to the 5 mm, 10 mm, 20 mm, respectively, of the average $1.14{\pm}0.13mm$, $1.05{\pm}0.20mm$, with $2.37{\pm}0.17mm$, suddenly for it is variations in breathing, respective average $1.87{\pm}0.19mm$, $2.15{\pm}0.21mm$, and analyzed with $2.44{\pm}0.26mm$. If the correlation error can be defined by the length of the displacement vector in the target track is a sinusoidal breathing mode, the size of the target of the movement in response to 5 mm, 10 mm, 20 mm, respective average $0.84{\pm}0.01mm$, $0.70{\pm}0.13mm$, with $1.63{\pm}0.10mm$, if it is a variant of sudden breathing respective average $0.97{\pm}0.06mm$, $1.44{\pm}0.11mm$, and analyzed with $1.98{\pm}0.10mm$. The larger the correlation error values in both the both the respiratory form, the target error value is large. If the motion size of the target of the sine curve breathing form is greater than or equal to 20 mm, was measured at 1.5 mm or more is a recommendation value of both cyber knife manufacturer of both error value. Conclusion : There is a tendency that the correlation error value between about target error value magnitude of the target motion is large is increased, the error value becomes large in variation of rapid respiration than breathing the form of a sine curve. The more the shape of the breathing large movements regular shape of sine curves target accuracy of the tumor tracking system can be judged to be reduced. Using the algorithm of Cyber-Knife tumor tracking system, when there is a change in the sudden unpredictable respiratory due patient coughing during treatment enforcement is to stop the treatment, it is assumed to carry out the internal target validation process again, it is necessary to readjust the form of respiration. Patients under treatment is determined to be able to improve the treatment of accuracy to induce the observed form of regular breathing and put like to see the goggles monitor capable of the respiratory form of the person.

  • PDF

Evaluation of Image Quality Based on Time of Flight in PET/CT (PET/CT에서 재구성 프로그램의 성능 평가)

  • Lim, Jung Jin;Yoon, Seok Hwan;Kim, Jong Pil;Nam Koong, Sik;Shin, Seong Hwa;Yoon, Sang Hyeok;Kim, Yeong Seok;Lee, Hyeong Jin;Lee, Hong Jae;Kim, Jin Eui;Woo, Jae Ryong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.110-114
    • /
    • 2012
  • Purpose : PET/CT is widely used for early checking up of cancer and following up of pre and post operation. Image reconstruction method is advanced with mechanical function. We want to evaluate image quality of each reconstruction program based on time of flight (TOF). Materials and Methods : After acquiring phantom images during 2 minutes with Gemini TF (Philips, USA), Biograph mCT (Siemens, USA) and Discovery 690 (GE, USA), we reconstructed image applied to Astonish TF (Philips, USA), ultraHD PET (Siemens, USA), Sharp IR (GE, USA) and not applied. inside of Flangeless Esser PET phantom (Data Spectrum corp., USA) was filled with $^{18}F$-FDG 1.11 kBq/ml (30 Ci/ml) and 4 hot inserts (8. 12. 16. 25 mm) were filled with 8.88 kBq/ml (240 ${\mu}Ci/ml$) the ratio of background activity and hot inserts activity was 1 : 8. Inside of triple line phantom (Data Spectrum corp., USA) was filled with $^{18}F$-FDG 37 MBq/ml (1 mCi). Three of lines were filled with 0.37 MBq (100 ${\mu}Ci$). Contrast ratio and background variability were acquired from reconstruction image used Flangeless Esser PET phantom and resolution was acquired from reconstruction image used triple line phantom. Results : The contrast ratio of image which was not applied to Astonish TF was 8.69, 12.28, 19.31, 25.80% in phantom lid of which size was 8, 12, 16, 25 mm and it which was applied to Astonish TF was 6.24, 13.24, 19.55, 27.60%. It which was not applied to ultraHD PET was 4.94, 12.68, 22.09, 30.14%, it which was applied to ultraHD PET was 4.76, 13.23, 23.72, 31.65%. It which was not applied to SharpIR was 13.18, 17.44, 28.76, 34.67%, it which was applied to SharpIR was 13.15, 18.32, 30.33, 35.73%. The background variability of image which was not applied to Astonish TF was 5.51, 5.42, 7.13, 6.28%. it which was applied to Astonish TF was 7.81, 7.94, 6.40 6.28%. It which was not applied to ultraHD PET was 6.46, 6.63, 5.33, 5.21%, it which was applied to ultraHD PET was 6.08, 6.08, 4.45, 4.58%. It which was not applied to SharpIR was 5.93, 4.82, 4.45, 5.09%, it which was applied to SharpIR was 4.80, 3.92, 3.63, 4.50%. The resolution of phantom line of which location was upper, center, right, which was not applied to Astonish TF was 10.77, 11.54, 9.34 mm it which was applied to Astonish TF was 9.54, 8.90, 8.88 mm. It which was not applied to ultraHD PET was 7.84, 6.95, 8.32 mm, it which was applied to ultraHD PET was 7.51, 6.66, 8.27 mm. It which was not applied to SharpIR was 9.35, 8.69, 8.99, it which was applied to SharpIR was 9.88, 9.18, 9.00 mm. Conclusion : Image quality was advanced generally while reconstruction program which is based on time of flight was used. Futhermore difference of result compared each manufacture reconstruction program showed up, however this is caused by specification of instrument of each manufacture and difference of reconstruction algorithm. Therefore we need further examination to find out appropriate reconstruction condition while using reconstruction program used for advance of image quality.

  • PDF

Change of Harmful Micnoorganisms in Pickling Process of Salted Cabbage According to Salting and Washing Conditions (배추김치의 절임공정 조건에 따른 위해미생물 변화)

  • Kim, Jin-Hee;Lee, Yu-Keun;Yang, Ji-Young
    • Journal of Food Hygiene and Safety
    • /
    • v.26 no.4
    • /
    • pp.417-423
    • /
    • 2011
  • Salted Cabbage products purchased from different companies at 4 different districts in South Korea were detected in this study. Cabbage and salt are the main materials for kimchi manufacture. The results of general bacteria contaminated in the samples were $1.4{\times}10^5$, $6.4{\times}10^5$, $1.7{\times}10^7$, $3.6{\times}10^7$ CFU/g in cabbage and $2.7{\times}10^3$ CFU/g in salt, respectively. The results of coliforms were detected as $2.4{\times}10^4$ CFU/g, and there was no Escherichia coli in any sample. Staphylococcus aureus was detected in cabbage as $9.9{\times}10^2$, $8.0{\times}10^1$, and $3.0{\times}10^3$ CFU/g, Bacillus cereus was also found in cabbage as $4.1{\times}10^3$ and $1.0{\times}10^1$ CFU/g. The results of Campylobacter jejuni and Vibrio paraheamolyticus were $2.4{\times}10^6$ and $1.0{\times}10^4$ CFU/g in cabbage, respectively. $1.0{\times}10^3$ CFU/g for Yersinia enterocolitica was determined in salt. In case of Listeria monocytogenes, the results were $1.5{\times}10^1$, $1.1{\times}10^2$, and $4.5{\times}10^1$ CFU/g in cabbage. Total batcteria ranged from $1.4{\times}10^1$ to $4.4{\times}10^5$ CFU/g were detected in salting solution, from $1.5{\times}10^4$ to $1.2{\times}10^8$ CFU/g in dehydrated salted-cabbage, from $9.4{\times}10^4{\sim}1.3{\times}10^8$ CFU/g in minced salted-cabbage. The results of E. coli in samples from different companies were different from one to anther. The results of the contamination of S. aureus and B. cereus showed positive in salting solution and dehydrated salted-cabbage at a portion of companies. V. paraheamolyticus was detected in salting solution. The contamination of Y. enterocolitica ranged from $9.5{\times}10^2$ to $1.8{\times}10^3$ CFU/g in salting solution, from $1.7{\times}10^1$ to $2.7{\times}10^2$ CFU/g in dehydrated salted-cabbage, from $1.2{\times}10^2$ to $1.3{\times}10^8$ CFU/g in minced salted-cabbage. The contamination of L. monocytogenes ranged from $8.0{\times}10^2$ to $1.7{\times}10^4$ CFU/g in salting solution, from $2.8{\times}10^2$ to $1.2{\times}10^4$ CFU/g in dehydrated salted-cabbage. During the manufacture processing of Kim chi, microorganisms were detected in cabbages salted in different concentrations of salt solution at 8%, 10%, 12% and 15% for 5-20 hours. As the results, $3.5{\times}10^5-1.7{\times}10^6$, $3.4{\times}10^5-2.5{\times}10^6$, $5.4{\times}10^5-2.3{\times}10^6$, $4.0{\times}10^5-2.3{\times}10^6$ CFU/g were detected for E. coli in samples at different treatment conditions. $1.9{\times}10^4-4.1{\times}10^4$, $4.1{\times}10^3-2.8{\times}10^4$, $1.5{\times}10^3-7.8{\times}10^3$, $2.2{\times}10^4-6.6{\times}10^4$ CFU/g were detected for S. aureus in samples at different treatment conditions. Salmonella typhimurium was detected in salted cabbage with various salt concentration after salting for 5 hrs, the result ranged from $2.5{\times}10^5$ to $3.8{\times}10^6$ CFU/g, and change of microorganism was the smallest in salted cabbage under the concentration of salting solution at 10% for 15 hours. The cabbage salted in 10% salting solution for 15 hours were washed with water for 2 and 3 times, with chlorine for 3 times, and with acetic acid for 3 times. E. coli was detected in the samples washed with water for 2 and 3 times, washed with chlorine for 3 times. The contamination of S. aureus was $3.0{\times}10^5$ CFU/g in the samples washed with water for 2 times, $5.6{\times}10^3$ CFU/g in the samples washed with acetic acid for 3 times, $3.6{\times}10^5$ CFU/g in the samples washed with water for 3 times and same amount in the samples washed with chlorine for 3 times. According to the results, the contamination of S. aureus was $5.6{\times}10^3$ CFU/g lower in samples washed with chlorine and acetic acid than that in samples washed with water. In case of S. typhimurium, it has been detected in samples washed with water and chlorine, $3.0{\times}10^1$ CFU/g as the lowest concentration among all the samples was measured in the samples washed with acetic acid for 3 times.

The Implementation of a HACCP System through u-HACCP Application and the Verification of Microbial Quality Improvement in a Small Size Restaurant (소규모 외식업체용 IP-USN을 활용한 HACCP 시스템 적용 및 유효성 검증)

  • Lim, Tae-Hyeon;Choi, Jung-Hwa;Kang, Young-Jae;Kwak, Tong-Kyung
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.42 no.3
    • /
    • pp.464-477
    • /
    • 2013
  • There is a great need to develop a training program proven to change behavior and improve knowledge. The purpose of this study was to evaluate employee hygiene knowledge, hygiene practice, and cleanliness, before and after HACCP system implementation at one small-size restaurant. The efficiency of the system was analyzed using time-temperature control after implementation of u-HACCP$^{(R)}$. The employee hygiene knowledge and practices showed a significant improvement (p<0.05) after HACCP system implementation. In non-heating processes, such as seasoned lettuce, controlling the sanitation of the cooking facility and the chlorination of raw ingredients were identified as the significant CCP. Sanitizing was an important CCP because total bacteria were reduced 2~4 log CFU/g after implementation of HACCP. In bean sprouts, microbial levels decreased from 4.20 logCFU/g to 3.26 logCFU/g. There were significant correlations between hygiene knowledge, practice, and microbiological contamination. First, personnel hygiene had a significant correlation with 'total food hygiene knowledge' scores (p<0.05). Second, total food hygiene practice scores had a significant correlation (p<0.05) with improved microbiological qualities of lettuce salad. Third, concerning the assessment of microbiological quality after 1 month, there were significant (p<0.05) improvements in times of heating, and the washing and division process. On the other hand, after 2 months, microbiological was maintained, although only two categories (division process and kitchen floor) were improved. This study also investigated time-temperature control by using ubiquitous sensor networks (USN) consisting of an ubi reader (CCP thermometer), an ubi manager (tablet PC), and application software (HACCP monitoring system). The result of the temperature control before and after USN showed better thermal management (accuracy, efficiency, consistency of time control). Based on the results, strict time-temperature control could be an effective method to prevent foodborne illness.

A Study on Food Safety of Distribution Foods in the Northern Gyeonggi Area (경기북부권역에서의 유통식품 안전성 연구)

  • Kang, Jeung-Bok;Bang, Seon-Jae;Kwon, Yeon-Ok;Jang, Mi-Jung;Oh, Sang-Hun;Park, Jeong-Hwa;Hong, Seung-Hee
    • Journal of Food Hygiene and Safety
    • /
    • v.31 no.5
    • /
    • pp.349-355
    • /
    • 2016
  • This study was performed to investigate food safety of 18,446 distribution foods in the northern Gyeongii area from 2010 to 2014 year. Food safety analysis was conducted by using Korean food code and food additives code. Fail determination about standards and specifications was 184 cases of 18,446 distribution foods, which represented about 1.00% fail rate of total cases. In the case of collected by food sanitation inspector, fail determination was 124 cases of 13,706 foods and showed about 0.90% fail rate. In the case of requested for food safety inspection, fail determination was 42 cases of 3,419 foods and showed about 1.23% fail rate. Results of fail determination by years, 61 cases (about 1.66%) detected fail among 3,683 foods in 2010 year, 37 cases (about 0.96%) detected fail among 3,863 foods in 2011 year, 44 cases (about 1.18%) detected fail among 3,721 foods in 2012 year, 25 cases (about 0.68%) detected fail among 3,669 foods in 2013 year, and 17 cases (about 0.48%) detected fail among 3,510 foods in 2014 year. In distribution of fail rate by month, september was showed the highest fail rate at 2.54% compared with other months. Fail determination by type of foods showed that 23 cases of perilla oil detected fail in 204 foods (about 11.27%), 32 cases of sesame oil detected fail in 394 foods (about 8.12%), 9 cases of pickles detected fail in 177 foods (about 5.08%), and 10 cases of red pepper powder detected fail in 283 foods (about 3.53%). For analysis of fail determination by examination items, microorganism was 28 fail cases (15.22%) and that was the highest level among examination items, linolenic acid and acid value were 27 fail cases (14.67%), iodine value was 19 fail cases (10.33%), content amount was 16 fail cases (8.70%), and sulfur dioxide was 9 fail cases (4.89%). In conclusion, the result of this study indicate that various fail determination items were detected of distribution foods on the market during the past five years and it was showed to higher hazard occurrence potential due to food. Therefore, more strict food safety control will be need for improving human health by prevent food health problem and ensure food safety.

Immunogenicity and Safety of a Haemophilus influenzae Type b Polysaccharide-Tetanus Toxoid Conjugate Vaccine (PRP-T: HiberixTM) in Korean Infants (우리나라 영아에서 PRP-T(HiberixTM)백신의 면역원성 및 안전성에 대한 연구)

  • Chung, Eun Hee;Kim, Yae Jean;Kim, Yun Kyung;Kim, Dong Ho;Seo, Jeong Wan;Lee, Hoan Jong
    • Pediatric Infection and Vaccine
    • /
    • v.10 no.1
    • /
    • pp.71-80
    • /
    • 2003
  • Purpose : Four kinds of Haemophilus influenzae type b protein conjugate vaccines, PRPD, PRP-T, PRP-OMP and PRP-CRM197, have been developed, and PRP-T vaccines are currently produced by two manufacturer, $ActHib^{(R)}$ by Aventis and $Hiberix^{TM}$ by GlaxoSmith-Kline Biologicals. The purpose of this study is to evaluate the immunogenicity and safety of $Hiberix^{TM}$ in Korean infants. Methods : Seventy-three healthy infants(43 male infants) were recruited for this study after parental informed consent was obtained. Each infant was vaccinated at 2, 4 and 6 months of age with the study vaccine. At each visit, infants were also immunized with DTaP, trivalent oral polio vaccine and hepatitis B vaccine when indicated. The serum anti-PRP antibody was measured at prevaccination, 2 month later after the 2nd dose, and 1 month later after the 3rd dose by the ELISA method. The local and systemic adverse reactions of vaccination were monitored for 3 consecutive days after each immunization. Immunogenicity of vaccine was evaluated in infants who received all the scheduled immunization and the adverse reactions were evaluated for infants who received at least one dose of the study vaccine. Results : Among seventy three infants, enrolled in this study; sixty three(37 male infants) completed all the scheduled immunizations. The geometric mean titer(GMT) of anti-PRP antibodies at prevaccination was 0.17 ${\mu}g/mL$(95% confidence interval[CI]; 0.13~0.22). The GMT of anti-PRP antibodies increased to 4.14 ${\mu}g/mL$(95% CI; 2.65~6.48) at 2 month later after the 2nd dose of PRP-T and 14.65 ${\mu}g/mL$(95% CI; 10.83~19.81) at 1 month later after the 3rd dose. Anti-PRP antibody ${\geq}0.15$ ${\mu}g/mL$, was observed in 98.4%(95% CI; 91.8~100) after 2 doses and 100%(95% CI; 100~100) after 3 doses. Anti-PRP antibody ${\geq}1.0$ ${\mu}g/mL$, was obtained in 77.8%(95% CI; 67.5~88.0) after 2 doses, and 98.4%(95% CI; 95.3~100) after 3 doses. Most of the adverse reaction after vaccination were mild. Irritability, the most common systemic reaction, was observed in 45.5%, followed by drowsiness(30.5%), poor feeding(26.7%) and fever(5.6%). Among the local reactions tenderness was observed in 7.9%, redness(${\geq}5$ mm) in 2.8% and swelling(${\geq}5$ mm) in 1.8%. Conclusion : The PRP-T vaccine used in this study was highly immunogenic and safe in Korean young infants. The finding that high GMT and high frequency of infants with a protective titer achieved after 2 doses is consistent with the previous studies which were done with a PRP-T vaccine of other manufacturer. This study suggests that the immunization schedule of PRP-T vaccine for Korean infants may need re-evaluation.

  • PDF

The relationships between lead exposure indicies and urinary δ-ALA by HPLC and colorimetric method in lead exposure workers (연노출근로자에 있어서 흡광광도법과 HPLC법에 의한 요중 δ-ALA 배설량과 연노출지표들 간의 관련성)

  • Ahn, Kyu-Dong;Lee, Sung-Soo;Hwangbo, Young;Lee, Gab-Soo;Yeon, You-Yong;Kim, Yong-Bae;Lee, Byung-Kook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.6 no.1
    • /
    • pp.77-87
    • /
    • 1996
  • In order to compare the difference of the measurement of delta aminolevulinic acid(${\delta}$-ALA) in urine between HPLC method(HALA) and colorimetric method(CALA), and also to provide useful information for the new diagnostic criteria of ${\delta}$-ALA in urine in lead poisoning, if at all possible in the future, authors studied 234 male lead workers who were selected from 7 storage battery factories, 3 secondary smelting industries, and 2 litharge making industries. Study subjects were selected on the basis of blood Zinc protoporphyrin(ZPP) level from low to high concentration to cover wide range of lead exposure. Study variables for this study were ${\delta}$-ALA measured by two different methods, blood lead(PbB), and blood ZPP. The results were as follows: 1. There was very high correlation between ${\delta}$-ALA measured by two method(r = 0.989 : HALA = -0.8194 + 0.8110 ${\times}$ CALA), but the value of CALA was measured about 2mg/L greater than HALA. 2. While the correlations of ${\delta}$-ALA by two method with blood lead and blood ZPP were 0.46 and 0.37 respectively, they were increased to 0.63 and 0.57 if ${\delta}$-ALA values were log-transformed. 3. Simple linear regression of ${\delta}$-ALA measured by two method on ZPP were as follows: CALA = 2.0421 + 0.0341 ${\times}$ ZPP ($R^2=0.1385$ p = 0.0001) HALA = 0.8006 + 0.0280 ${\times}$ ZPP ($R^2=0.1389$ p = 0.0001) 4. Simple linear regression of ${\delta}$-ALA measured by two method on PbB were as follows: CALA = - 0.4134 + 0.1545 ${\times}$ PbB ($R^2=0.2085$ p = 0.0001) HALA = -1.2893 + 0.1287 PbB ($R^2=0.2154$ p = 0.0001), 5. Simple linear regression of log-transformed ${\delta}$-ALA by two method on ZPP and PbB were as follows: logHALA = 0.3078 + 0.0060 ZPP ($R^2=0.3329$ p = 0.0001) logCALA = 1.0189 + 0.0044 ZPP ($R^2=0.3290$ p = 0.0001) logHALA = -0.0221 + 0.0246 PbB ($R^2=0.4046$ p = 0.0001) logCALA = 0.7662 + 0.0184 PbB ($R^2=0.4108$ p = 0.0001) 6. The cumulative percent of colorimetric method to detect lead workers whose value of PbS and ZPP were over screening level such as $40{\mu}/dl$ and $100{\mu}/dl$ respectively was higher than HPLC method if cut-off level of ${\delta}$-ALA for screening of lead poisoning was 5 mg/L. But if cut-off level of ${\delta}$-ALA measured by HPLC was reduced to 3 mg/L which is compatible to 5 mg/L of ${\delta}$-ALA measured by colorimetric method, there were good agreement between two methods and showed dose-response relationship with other lead exposure indices such as PbB and ZPP.

  • PDF