• Title/Summary/Keyword: 제작재료

Search Result 5,096, Processing Time 0.039 seconds

EFFECT OF INSTRUMENT COMPLIANCE ON THE POLYMERIZATION SHRINKAGE STRESS MEASUREMENTS OF DENTAL RESIN COMPOSITES (측정장치의 compliance 유무가 복합레진의 중합수축음력의 측정에 미치는 영향)

  • Seo, Deog-Gyu;Min, Sun-Hong;Lee, In-Bog
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.2
    • /
    • pp.145-153
    • /
    • 2009
  • The purpose of this study was to evaluate the effect of instrument compliance on the polymerization shrinkage stress measurements of dental composites. The contraction strain and stress of composites during light curing were measured by a custom made stress-strain analyzer, which consisted of a displacement sensor, a cantilever load cell and a negative feedback mechanism. The instrument can measure the polymerization stress by two modes: with compliance mode in which the instrument compliance is allowed, or without compliance mode in which the instrument compliance is not allowed. A flowable (Filtek Flow: FF) and two universal hybrid (Z100: Z1 and Z250: Z2) composites were studied. A silane treated metal rod with a diameter of 3.0 mm was fixed at free end of the load cell, and other metal rod was fixed on the base plate. Composite of 1.0 mm thickness was placed between the two rods and light cured. The axial shrinkage strain and stress of the composite were recorded for 10 minutes during polymerization. and the tensile modulus of the materials was also determined with the instrument. The statistical analysis was conducted by ANOVA. paired t-test and Tukey's test (${\alpha}<0.05$). There were significant differences between the two measurement modes and among materials. With compliance mode, the contraction stress of FF was the highest: 3.11 (0.13). followed by Z1: 2.91 (0.10) and Z2: 1.94 (0.09) MPa. When the instrument compliance is not allowed, the contraction stress of Z1 was the highest: 17.08 (0.89), followed by FF: 10.11 (0.29) and Z2: 9.46 (1.63) MPa. The tensile modulus for Z1, Z2 and FF was 2.31 (0.18), 2.05 (0.20), 1.41 (0.11) GPa, respectively. With compliance mode. the measured stress correlated with the axial shrinkage strain of composite: while without compliance the elastic modulus of materials played a significant role in the stress measurement.

Effect of infection control barrier thickness on light curing units (감염 조절용 차단막의 두께가 광중합기의 중합광에 미치는 영향)

  • Chang, Hoon-Sang;Lee, Seok-Ryun;Hong, Sung-Ok;Ryu, Hyun-Wook;Song, Chang-Kyu;Min, Kyung-San
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.5
    • /
    • pp.368-373
    • /
    • 2010
  • Objectives: This study investigated the effect of infection control barrier thickness on power density, wavelength, and light diffusion of light curing units. Materials and Methods: Infection control barrier (Cleanwrap) in one-fold, two-fold, four-fold, and eightfold, and a halogen light curing unit (Optilux 360) and a light emitting diode (LED) light curing unit (Elipar FreeLight 2) were used in this study. Power density of light curing units with infection control barriers covering the fiberoptic bundle was measured with a hand held dental radiometer (Cure Rite). Wavelength of light curing units fixed on a custom made optical breadboard was measured with a portable spectroradiometer (CS-1000). Light diffusion of light curing units was photographed with DSLR (Nikon D70s) as above. Results: Power density decreased significantly as the layer thickness of the infection control barrier increased, except the one-fold and two-fold in halogen light curing unit. Especially, when the barrier was four-fold and more in the halogen light curing unit, the decrease of power density was more prominent. The wavelength of light curing units was not affected by the barriers and almost no change was detected in the peak wavelength. Light diffusion of LED light curing unit was not affected by barriers, however, halogen light curing unit showed decrease in light diffusion angle when the barrier was four-fold and statistically different decrease when the barrier was eight-fold (p < 0.05). Conclusions: It could be assumed that the infection control barriers should be used as two-fold rather than one-fold to prevent tearing of the barriers and subsequent cross contamination between the patients.

THE CHANGE OF THE INITIAL DYNAMIC VISCO-ELASTIC MODULUS OF COMPOSITE RESINS DURING LIGHT POLYMERIZATION (광중합 복합레진의 중합초기 동적 점탄성의 변화)

  • Kim, Min-Ho;Lee, In-Bog
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.5
    • /
    • pp.450-459
    • /
    • 2009
  • The aim of this study was to measure the initial dynamic modulus changes of light cured composites using a custom made rheometer. The custom made rheometer consisted of 3 parts: (1) a measurement unit of parallel plates made of glass rods, (2) an oscillating shear strain generator with a DC motor and a crank mechanism, (3) a stress measurement device using an electromagnetic torque sensor. This instrument could measure a maximum torque of 2Ncm, and the switch of the light-curing unit was synchronized with the rheometer. Six commercial composite resins [Z-100 (Z1), Z-250 (Z2), Z-350 (Z3), DenFil (DF), Tetric Ceram (TC), and Clearfil AP-X (CF)] were investigated. A dynamic oscillating shear test was undertaken with the rheometer. A certain volume ($14.2\;mm^3$) of composite was loaded between the parallel plates, which were made of glass rods (3 mm in diameter). An oscillating shear strain with a frequency of 6 Hz and amplitude of 0.00579 rad was applied to the specimen and the resultant stress was measured. Data acquisition started simultaneously with light curing, and the changes in visco-elasticity of composites were recorded for 10 seconds. The measurements were repeated 5 times for each composite at $25{\pm}0.5^{\circ}C$. Complex shear modulus G*, storage shear modulus G', loss shear modulus G" were calculated from the measured strain-stress curves. Time to reach the complex modulus G* of 10 MPa was determined. The G* and time to reach the G* of 10 MPa of composites were analyzed with One-way ANOVA and Tukey's test ($\alpha$ = 0.05). The results were as follows. 1. The custom made rheometer in this study reliably measured the initial visco-elastic modulus changes of composites during 10 seconds of light curing. 2. In all composites, the development of complex shear modulus G* had a latent period for $1{\sim}2$ seconds immediately after the start of light curing, and then increased rapidly during 10 seconds. 3. In all composites, the storage shear modulus G" increased steeper than the loss shear modulus G" during 10 seconds of light curing. 4. The complex shear modulus of Z1 was the highest, followed by CF, Z2, Z3, TC and DF the lowest. 5. Z1 was the fastest and DF was the slowest in the time to reach the complex shear modulus of 10 MPa.

Flexural Test of H-Shape Members Fabricated of High-Strength Steel with Considering Local Buckling (국부좌굴을 고려한 고강도 조립 H형강 부재의 휨성능 실험)

  • Lee, Cheol-Ho;Han, Kyu-Hong;Park, Chang-Hee;Kim, Jin-Ho;Lee, Seung-Eun;Ha, Tae-Hyu
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.4
    • /
    • pp.417-428
    • /
    • 2011
  • Depending on the plastic deformation capacity required, structural steel design under the current codes can be classified into three categories: elastic, plastic, and seismic design. Most of the current steel codes explicitly forbid the use of a steel material with a yield strength higher than 450 MPa in the plastic design because of the concerns about its low plastic deformation capacity as well as the lack of test data on local and lateral torsional buckling behavior. In this study, flexural tests on full-scale H-shape members built with SM490A (ordinary steel or benchmark material) and HSB800 (high-strength steel) were carried out. The primary objective was to investigate the appropriateness of extrapolating the local buckling criterion of the current codes, which was originally developed for normal-strength steel, to the case of high-strength steel. All the SM490A specimens performed consistently with the current code criteria and exhibited sufficient strength and ductility. The performance of the HSB800 specimens was also very satisfactory from the strength perspective; even the specimens with a noncompact and slender flange developed the plastic moment capacity. The HSB800 specimens, however, showed an inferior plastic rotation capacity due to the premature tensile fracture of the beam bottom flange beneath the vertical stiffener at the loading point. The plastic rotation capacity that was achieved was less than 3 (or the minimum level required for a plastic design). Although the test results in this study indicate that the extrapolation of the current flange local-buckling criterion to the case of high-strength steel is conservative from the elastic design perspective, further testing together with an associated analytical study is required to identify the causes of the tensile fracture and to establish a flange slenderness criterion that is more appropriate for high-strength steel.

Interpretation of the Manufacturing Characteristics and the Mineral and Chemical Composition of Neolithic Pottery Excavated from the Jungsandong Site, Yeongjong Island, South Korea (영종도 중산동 신석기시대 토기의 광물 및 화학조성과 제작특성 해석)

  • Lee, Chan Hee;Kim, Ran Hee;Shin, Sook Chung
    • Korean Journal of Heritage: History & Science
    • /
    • v.51 no.1
    • /
    • pp.4-31
    • /
    • 2018
  • The Neolithic pottery excavated from the Jungsandong site has been classified into four types of pottery (I: feldspar type, II: mica type, III: talc type and IV: asbestos type) according to their mineral composition. These four types of potteries generally appear to have undergone incomplete firing, while the level of oxidation in the type I pottery objects, which have a relatively higher clay content, was found to be particularly low. The type III objects, which have a high talc content, are judged to have been somewhat slow in removing carbon because they contain saponite belonging to the smectite group. Of the four types of pottery, type IV showed the highest redness and the most uniform characteristics, thus indicating a good level of oxidation. In particular, fixed carbide (C; 33.7 wt.%) with a thickness of about 1mm, and originating from organic substances, was detected inside the walls of the type I pottery, while the deep radial cracks in the outer surfaces of the pottery are thought to have been caused by repeated thermal shocks. Given that all of the pottery except for the type I artifacts are considered to be have been made for storage purposes, those containing talc and tremolite are easy to done liquid storing vessels based on an analysis of their material characteristics. As for the type II relics, which are composed of various minerals and exhibit poor physical properties, they seem to have been used for simple storage purposes. As domestic talc and asbestos mines were concentrated in the areas of Gyeonggi, Gangwon, Chungbuk, and Chungnam, it seems likely that talc and tremolite were produced as contiguous minerals. Considering the distance between the remains in Jungsandong and these mines and their geographical distribution, there is a possibility - albeit somewhat slight - that these mines were developed for the mining of various minerals. Although ultramafic rock masses - such as serpentine capable of generating talc and tremolite - have not been found in the Jungsandong area, limestone and biotite granite containing mica schist have been identified in the northwestern part of Yeongjong Island, indicating that small rock masses might have formed there in the past. Therefore, it is judged necessary to accumulate data on pottery containing talc and tremolite, other than the remains in Jungsandong, and to investigate the rocks and soils in the surrounding area with greater precision. The firing temperatures of the pottery found at the Jungsandong site were interpreted by analyzing the stability ranges of the mineral composition of each type. As a result, they have been estimated to range from 550 to $800^{\circ}C$ for the type I artifacts, and from 550 to $700^{\circ}C$ for the type I, II and IV artifacts. However, these temperatures are not the only factors to have affected their physical properties and firing temperature, and the types, particle sizes, and firing time of the clay should all be taken into consideration.

Material Characteristics and Provenance Interpretation of Jade(Amazonite) from the Sijeonri Site at Asan, Korea (아산 시전리 유적 출토 옥기(천하석)의 재료과학적 특성과 산지해석)

  • Lee, Chan Hee;Kim, Jae Cheol;Na, Geon Ju;Kim, Myung Jin
    • Korean Journal of Heritage: History & Science
    • /
    • v.39
    • /
    • pp.219-242
    • /
    • 2006
  • Quantitative analysis and provenance interpretation of the raw materials for the jade (amazonite) excavated from the Asan Sijeonri site were studied. Geology of the Sijeonri site composed mainly of Precambrian metasedimentary rocks and the alluvium ranges extensively. In the site, amazonite jade was excavated in the Bronze Age No. 4 circular-shaped resident site. The jade has a comma-shaped and shows light green color with so much cracks. The jade is silicate mineral of columnar habits that is shown white streak, and has fine cleavages with vitreous luster. As the analytical results, this jade was identified as a feldspar-group mineral gemologically called amazonite that is mineralogically microcline formed to intergrowth of albite and orthoclase. Internal textures of the amazonite present Na-end member of albite coexisting with K-end member of orthoclase that are replaced each other along the cleavages and twin planes with several ${\mu}m$ scales. Therefore, the amazonite is one mineral phase combined with albite and orthoclase by substitution of $Na_2O$ and $K_2O$, respectively. The Danyang are is an unique producing site of amazonite in South Korea, and Gongju Janggimyeon was known as microcline provenance to the utmost area from the Sijeonri site. In the marginal area of southern coast in Korean Peninsula, Bronze Age amazonite has been excavated in several sites, where original provenance of the raw amazonite is not identified. The Sijeonri site does not show any facilities of producing and processing traces for amazonite jade. Also, only one jade was collected in the Sijeonri site. Therefore, there is not possibility that the provenance of raw jade is the Sijeonri area. To explain original provenance of the amazonite jade, migration path, manufacturing process and archaeological interpretation are required.

A Comparative Study on the Change in Oriental Linked pearls Pattern (동전(東傳) 연주문의 변천과정 비교연구 -5세기~10세기 벽화복식 및 출토 직물을 중심으로-)

  • An, Bo-yeon
    • Korean Journal of Heritage: History & Science
    • /
    • v.40
    • /
    • pp.243-270
    • /
    • 2007
  • Linked pearls pattern expressed on textiles have no limited scale or shape when manufacturing, so they are free in expression. And from the design, material, and color we can analogize the social culture of that age. Oriental linked pearls pattern was started from the Sasanian Persia and introduced through the Silk Road, so it is closely connected with the East and the West culture. This study will consider from the 5th century to the 10th century; the mural costume of the West Central Asia, the ancient textiles excavated from the Sinjiang and Qinghai area of China, and the linked pearls pattern which are collected at Shosoin, Japan. And from this study, will concentrate on clarifying the linked pearls pattern's condition of the cultural exchange between the East and the West and it's structural variation process. The design of linked pearls pattern delivered to the East through the Silk Road is differed by area. For example, in the Western Pamir Plateau, where the ancient Sogdians mainly lived, the excavated linked pearls pattern's subject were deer or cassowary variated from the West Asian motif. But the ones excavated from Kucha Xingang had Chinese motifs added so they showed Chinese characters or Buddhist Bodhisattva image instead of Helios. Like this, the appearance of new patterns, which were accompanied by structural variations, gradually deviated from the standardized pattern of the Sasanian Persia. And this structural variation process has relations with the construction and arrangement method of various patterns of the after ages. The foliated floral Spray, which is placed at the lozenge space of linked pearls' space, had developed into ogival - shaped pattern (Neunghwamun). And the prevalence of geometrical structure pattern after the 10th century and the unfolding method of Tapjamun which is arranging unit pattern in order, are similar to the linked pearl pattern. In brief, linked pearls pattern accompanied by technical improvement let us understand the polished artistic code from its expression, and has importance in showing universal pattern beyond region and culture.

Effect of polishing methods on color change by water absorption in several composite resins (여러 복합레진에서 수분 흡수에 의한 색변화에 연마가 미치는 영향)

  • Kim, Hye Jin;Kim, Mi-yeon;Song, Byung-chul;Kim, Sun-ho;Kim, Jeong-hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.35 no.1
    • /
    • pp.1-10
    • /
    • 2019
  • Purpose: The aim of this study was to evaluate the influence of polishing methods on the color stability of composite resins. Materials and Methods: Two bulk-fill and four conventional resin composites were filled in cylindrical molds (6 mm diameter, 4 mm height) and light-cured. The specimens were stored in $34^{\circ}C$ distilled water for 24 h. Spectrophotometer was used to determine the color value according to the CIE $L^*a^*b^*$ color space. Each group was divided into three groups according to polishing methods (n = 5). Group 1 was control group (Mylar strip group), group 2 was polished with PoGo, and group 3 was polished with Sof-Lex Spiral wheels. Color evaluation was performed weekly for 4 weeks after immersion in $34^{\circ}C$ distilled water. The results were analyzed by generalized least squares method (P < 0.05). Results: Generalized least squares analysis revealed that Sof-Lex Spiral wheels group showed the significantly lower ${\Delta}E$ values compared to PoGo and control group (P < 0.05). The ${\Delta}E$ values of polished group showed the significantly lower than the ${\Delta}E$ values of unpolished group (P < 0.05). Regarding color changes of composite resins, there was no significant difference between the ${\Delta}E$ values of Filtek Z250 and Filtek Z350 XT Universal restorative in all time intervals (P < 0.05). Tetric N-Ceram Bulk Fill showed the significantly lower ${\Delta}E$ values compared to other composite resins in 1, 2, 3 weeks (P < 0.05). Conclusion: Within the limitations of this study, polishing methods influence the color stabilities of composite resins. The group polished with Sof-Lex Spiral Wheels showed more resistance to discoloration than group polished with PoGo.

Comparison of Thyroid Doses for Shielding Material Changes in Neck Computed Tomography (Neck CT에서 차폐체 재료 변화에 따른 Thyroid 선량 비교 연구)

  • Kang, Eun Bo
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.65-71
    • /
    • 2019
  • With regard to current Neck CT, Bismuth shielding boards are often being used to reduce exposure to superficial organs such as the thyroid. However, beam hardening often occurs near superficial organs with Bismuth shielding boards and variations in CT Number, Noise, and Uniformity values occur severely. This study looked into the usefulness of shielding boards made from aluminum and silicone that can be easily obtained and have good machinability by comparing them to the existing Bismuth shielding board. An Aluminum 7.3mm and a Silicone 21.5mm were made with shielding ratios similar to that of the Bismuth(0.06 mmPb). TLD (TLD-100) was placed on the thyroid area of the Phantom (RS-108T) and 5 doses were measured for each. To compare image quality, CT Number and Noise variations in axial images of the thyroid area in Neck CT images were compared. Also, variations in CT Number, Noise, and Uniformity were measured in the AAPM phantom images and compared. In the results, when thyroid doses for each shielding board were compared, the Bismuth shielding board showed a 14% reduction, the Silicone 21.5mm showed a 15% reduction, and the Aluminum 7.3mm showed a 13% reduction compared to the Non-Shield. Statistically, there were no significant differences in comparison with the Bismuth shielding board. In CT Number variations of thyroid area images, variations were largest for the Bismuth shielding board. With Uniformity evaluations of the AAPM phantom, the Bismuth shielding board was found unsuitable and the Aluminum 7.3mm and Silicone 21.5mm satisfied the acceptance criteria. Research results show that the Aluminum 7.3mm and Silicone 21.5mm have a similar shielding ratio to the high-priced Bismuth shielding board that is currently being used clinically and in comparison tests of CT Number attenuation coefficient variations, Noise, and Uniformity which are phantom image evaluation items, they proved to be better than Bismuth shielding boards. If various shielding boards are made using aluminum and silicone, sized appropriately for superficial organs, it would be useful in decreasing patient doses.

Effects of primers on the microtensile bond strength of resin cements to cobalt-chromium alloy (레진 시멘트와 코발트 크롬 합금의 미세인장결합강도에 다양한 프라이머들이 미치는 영향)

  • Jung, Hong-Taek;Campana, Shiela A.;Park, Jin-Hong;Shin, Joo-Hee;Lee, Jeong-Yol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.2
    • /
    • pp.95-101
    • /
    • 2019
  • Purpose: The aim of this study is to evaluate the effects of various primers on the microtensile bond strength (${\mu}TBS$) of resin cements to cobalt-chromium (Co-Cr) dental casting alloy. Materials and methods: Four adhesive primers (Universal primer, Metal primer II, Alloy primer, and Metal/Zirconia primer) and two resin cements (Panavia F2.0, G-CEM LinkAce) were tested. One hundred fifty Co-Cr beams were prepared from Co-Cr ingots via casting ($6mm\;ength{\times}1mm\;width{\times}1mm\;thick$). The metal beams were randomly divided into ten groups according to the adhesive primers and resin cements used; the no-primer groups served as the control (n = 15). After sandblasting with aluminum oxide ($125{\mu}m$ grain), the metal and resin cements were bonded together using a silicone mold. Prior to testing, all metal-resin beams were examined under stereomicroscope, and subjected to the ${\mu}TBS$ test. The mean value of each group was analyzed via one-way ANOVA with Tukey's test as post hoc (${\alpha}=.05$) using SPSS software. Results: The mean ${\mu}TBS$ of all groups was ranged from 20 to 28 MPa. There is no statistically significant difference between groups (P > .05). Mixed failure, which is the combination of adhesive and cohesive failures, is the most prevalent failure mode in both the Panavia F2.0 and G-Cem LinkAce groups. Conclusion: The ${\mu}TBS$ of all tested groups are relatively high; however, the primers used in this study result in no favorable effect in the ${\mu}TBS$ of Panavia F2.0 and G-Cem LinkAce resin cement to Co-Cr alloy.