• Title/Summary/Keyword: 정진구동

Search Result 97, Processing Time 0.022 seconds

Design Factor Analysis of Aerospike Pintle Nozzle for Increasing Thrust in Off-Design (탈설계 조건에서 추력 증대를 위한 에어로 스파이크 핀틀 노즐의 설계인자 분석 연구)

  • Kim, Jeongjin
    • Journal of Aerospace System Engineering
    • /
    • v.16 no.4
    • /
    • pp.1-9
    • /
    • 2022
  • A design factor analysis was conducted to reduce the thrust reduction in the off-design, due to the driving of the aerospike pintle nozzle. The close (NPR 100) as well as the open (NPR 11) stroke were fixed, as under-expansion conditions. The pintle contour, pintle head radius (R), cowl angle (θ), and cowl exit length (L) were selected as design factors. The change in thrust was analyzed, using a verified numerical analysis technique. First, the pintle head radius and the length of the cowl exit had little influence on the thrust. The cowl angle changed the mass flow rate by affecting the effective nozzle throat area, and created a reverse pressure gradient at the cowl exit. As a result of applying the dual aerospike contour, it was confirmed that the thrust in the design-off increased by approximately 1.2%, compared to the reference case and by approximately 3.4% compared to the worst case.

An Analytical Study of Chloride Ion Diffusion in Concrete via Cellular Automaton Method (셀룰러 오토마톤 법을 이용한 콘크리트의 염화물이온 확산현상의 해석적 연구)

  • Kim, Jeong-Jin;Seok, Won-Kyun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.24 no.5
    • /
    • pp.541-552
    • /
    • 2024
  • This study introduces a new analytical model known as the Cellular Automaton Method(CAM) designed to predict the degree of deterioration in concrete, taking into account its complex pore structure. The CAM model assesses the impacts of moisture migration, driven by capillary action and pressure differentials at the gas-liquid interface, which are influenced by the distribution of pores. It also evaluates how porosity and diffusion coefficients affect the penetration of chloride ions. The model's application revealed distinct moisture movement patterns in concrete structures, distinguishing between those with porosity levels below and above 40 percent. Additionally, it facilitated a comparison and analysis of chloride ion diffusion phenomena, based on diffusion coefficients in areas penetrated by moisture, against results obtained from the Finite Element Method(FEM). The comparison showed a maximum deviation of only 0.989 percent between the predicted outcomes of the FEM and CAM, demonstrating substantial agreement and validating CAM's efficacy in simulating the diffusion processes of chloride ions within concrete under actual salt damage conditions. Thus, CAM proves to be a reliable tool for modeling and anticipating deterioration in concrete structures exposed to saline environments.

Analysis and Improvement of System Efficiency for the Moving-actuator type Bi-Ventricular Assist Device ($AnyHeart^{TM}$) (한국형 양심실 보조 인공 심장의 효율 분석 및 개선에 관한 연구)

  • Chung, J.H.;Nam, K.W.;Choi, S.W.;Lee, J.J.;Park, C.Y.;Kim, W.E.;Choi, J.S.;Min, B.G.
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.5
    • /
    • pp.449-458
    • /
    • 2001
  • This is a test report of system efficiency for the moving-actuator type Bi-ventricular assist device (AnyHear $t^{MT}$ ) Seoul National University). $AnyHeart^{TM}$), as an energy converter. utilities a brushless DC motor(S/M 566-26A. Sierracin/ Magnedyne, Carlsbad, CA. U.S.A.) generating their pendulous motion in the epicyclic gear train. It is necessary to know about the overall efficiency of the system. The system is subdivided into three parts: motor part, actuator part and blood sac part (including valves, etc.) according to system mechanism. The motor was operated with a variable range of torque. angular speed and width of voltage Pulse In this report. $AnyHeart^{TM}$ is focused on the efficiency of the motor and actuator parts. 4 $\ell/min$ pump output. which is normal condition of $AnyHeart^{TM}$ system, the total system efficiency is 8%, which is composed of 50%, 85% and 17% efficiency (motor Part, actuator Part and blood sac Part) respectively. In the analyzed result. applied input voltage on normal condition of $AnyHeart^{TM}$ is determined. Also speed Profile with considering filling state of blood sac is Provided. In the test of the in vitro mock circulation. some experimental results are Provided to demonstrate the effectiveness of the Presented approach.

  • PDF

W-band Single-chip Receiver MMIC for FMCW Radar (FMCW 레이더용 W-대역 단일칩 수신기 MMIC)

  • Lee, Seokchul;Kim, Youngmin;Lee, Sangho;Lee, Kihong;Kim, Wansik;Jeong, Jinho;Kwon, Youngwoo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.10
    • /
    • pp.159-168
    • /
    • 2012
  • In this paper, a W-band single-chip receiver MMIC for FMCW(Frequency-modulated continuous-wave) radar is presented using $0.15{\mu}m$ GaAs pHEMT technology. The receiver MMIC consists of a 4-stage low noise amplifier(LNA), a down-converting mixer and a 3-stage LO buffer amplifier. The LNA is designed to exhibit a low noise figure and high linearity. A resistive mixer is adopted as a down-converting mixer in order to obtain high linearity and low noise performance at low IF. An additional LO buffer amplifier is also demonstrated to reduce the required LO power of the W-band mixer. The fabricated W-band single-chip receiver MMIC shows an excellent performance such as a conversion gain of 6.2 dB, a noise figure of 5.0 dB and input 1-dB compression point($P_{1dB,in}$) of -12.8 dBm, at the RF frequency of $f_0$ GHz, LO input power of -1 dBm and IF frequency of 100 MHz.

Analysis of the Respiratory Motion Effects on Dose Distribution Using TLD Phantom (열형광선량계용 팬톰을 이용한 호흡 움직임에 따른 선량분포의 평가)

  • Hong, Ju-Young;Kim, Yon-Lae;Rah, Jeong-Eun;Chung, Jin-Beom;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.17 no.4
    • /
    • pp.187-191
    • /
    • 2006
  • The purpose of this study was to measure the dose distribution from the moving phantom for the respiratory motion. The phantom for TLD measurement was designed and built for this study based on the multiple plates for placing TLD and film. The TLDs may be inserted at 3 mm intervals in each TLD plate. For the measurements, TLD plate was inserted into the phantom at 1.5 cm ($d_{max}$) depth, and phantom was allowed to move in SI directions in the range of 1 to 2 cm with 0.5 cm interval for 6 MV X-ray beams. Penumbra and FWHM were measured at both moving state and compared stationary. It was found that penumbra increased 0.71 cm at stationary and 2.10 cm at moving state in 2 cm movement, and that FWHM are 7.52 cm for stationary state and 7.02 cm for moving state (2 cm movement). In this study, film was used to compared with TLD results of measurements and simitar results were observed. Therefore, it is expected that TLD moving phantom may be useful for the treatment of tumors that move due to the respiratory motion.

  • PDF

Application of Habitat Suitability Models for Assessing Climate Change Effects on Fish Distribution (어류 분포에 미치는 기후변화 영향 평가를 위한 서식적합성 모형 적용)

  • Shim, Taeyong;Bae, Eunhye;Jung, Jinho
    • Ecology and Resilient Infrastructure
    • /
    • v.3 no.2
    • /
    • pp.134-142
    • /
    • 2016
  • Temperature increase and precipitation changes caused by change alter aquatic environments including water quantity and quality that eventually affects the habitat of aquatic organisms. Such changes in habitat lead to changes in habitat suitability of the organisms, which eventually determines species distribution. Therefore, conventional habitat suitability models were investigated to evaluate habitat suitability changes of freshwater fish cause by change. Habitat suitability models can be divided into habitat-hydraulic (PHABSIM, CCHE2D, CASiMiR, RHABSIM, RHYHABSIM, and River2D) and habitat-physiologic (CLIMEX) models. Habitat-hydraulic models use hydraulic variables (velocity, depth, substrate) to assess habitat suitability, but lack the ability to evaluate the effect of water quality, including temperature. On the contrary, CLIMEX evaluates the physiological response against climatic variables, but lacks the ability to interpret the effects of physical habitat (hydraulic variables). A new concept of ecological habitat suitability modeling (EHSM) is proposed to overcome such limitations by combining the habitat-hydraulic model (PHABSIM) and the habitat-physiologic model (CLIMEX), which is able to evaluate the effect of more environmental variables than each conventional model. This model is expected to predict fish habitat suitability according to climate change more accurately.

An Effect of Time Gating Threshold (TGT) on the Delivered Dose at Internal Organ with Movement due to Respiration (호흡에 의해 내부 움직임을 갖는 장기에 전달되는 선량에서 Time Gating Threshold (TGT)의 효과)

  • Kim Yon Lae;Chung Jin Bum;Chung Won Kyun;Hong Semie;Suh Tae Suk
    • Progress in Medical Physics
    • /
    • v.16 no.2
    • /
    • pp.89-96
    • /
    • 2005
  • In this study, we investigated the effect of time gating threshold on the delivered dose at a organ with internal motion by respiration. Generally, the internal organs have minimum motion at exhalation during normal breathing. Therefore to compare the dose distribution time gating threshold, in this paper, was determined as the moving region of target during 1 sec at the initial position of exhalation. The irradiated fields were then delivered under three conditions; 1) non-moving target 2) existence of the moving target in the region of threshold (1sec), 3) existence of the moving target region out of threshold (1.4 sec, 2 sec). And each of conditions was described by the moving phantom system. It was compared with the dose distributions of three conditions using film dosimetry. Although the treatment time increased when the dose distributions was obtained by the internal motion to consider the TGT, it could be obtained more exact dose distribution than in the treatment field that didn't consider the internal motion. And it could be reduced the unnecessary dose at the penumbra region. When we set up 1.4 sec of threshold, to reduce the treatment time, it could not be obtained less effective dose distribution than 1 sec of threshold. Namely, although the treatment time reduce, the much dose was distributed out of the treatment region. Actually when it is treated the moving organ, it would rather measure internal motion and external motion of the moving organ than mathematical method. If it could be analyzed the correlation of the internal and external motion, the treatment scores would be improved.

  • PDF