• Title/Summary/Keyword: 정전방식

Search Result 270, Processing Time 0.029 seconds

A Study on the NOx Reduction of Flue Gas Using Un-divided Electrolysis of Seawater (무격막식 해수 전기분해 방식을 통한 배연 탈질에 관한 연구)

  • Kim, Tae-Woo;Choi, Su-Jin;Kim, Jong-Hwa;Song, Ju-Yeong
    • Korean Chemical Engineering Research
    • /
    • v.50 no.5
    • /
    • pp.825-829
    • /
    • 2012
  • In this study, we investigated NO oxidation characteristic that depends on available chlorine concentration and temperature of seawater which is treated by un-divided electrolysis. Reactant gas passed through bubbling reactors which is filled with electrolyzed water and then NO concentration change was analyzed. In the closed-loop electrolysis system, concentration of available chlorine increased with electrolysis time. The higher oxidation rate of NO to $NO_2$ was obtained with the higher concentration of available chlorine. Oxidation of NO was fast when temperature of electrolyzed water was high, in the case of same concentration of available chlorine.

Development of the voltage management recorder using o dual-slope A/D converter for power distribution lines (Dual-slope A/D 변환을 이용한 배전선 전압관리용 계측기 개발)

  • 손수국
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.5
    • /
    • pp.38-44
    • /
    • 2002
  • This paper describes the development of a new voltage recorder for the voltage management of power distribution lines. The voltage characteristics and measurement problems for the power distribution lines are analyzed and the functions required for the recorder are discussed. Applying a dual-slope A/D converter with low noise characteristics the voltage measurement algorithm, design and implementation for the recorder are discussed. Finally, the voltage variations of long-duration over-voltages or under-voltages, and short-duration temporary interruption based on IEEE 1159 are analyzed. It is verified with the experiment.

The Analysis of Mal-Operation of Protection Relay for Detecting Disconnection of Neutral Grounding Reactor (전력용 변압기 중성점 리액터 단선 감시용 보호계전기 오동작 사례 분석)

  • Kang, Y.W.;Kwak, J.S.;Kim, G.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.603-605
    • /
    • 2005
  • 전력수요의 증대에 따른 계동모의 확장에 따라 관련기기는 초고압 및 대용량화 추세에 있다. 이러한 관련기기들 중에서도 특히 154/22.9kV 전력용 변압기는 고장시 수용가의 정전범위가 방대하고 변압기 내부 고장의 복구비용 또한 막대하므로 경제적 손실은 물론 사회적 영향도 크다. 우리나라에서는 1980년 초기부터 154/22.9kV 전력용 변압기의 고장이 급증하였으며, 이러한 원인은 주로 직전접지 방식을 채택하고 있는 한전 계통에서 배전선의 지락고장에 의한 지락고장 전류가 변압기 중성점을 통하여 변압기에 충격을 가함으로써 변압기 권선 단락 절연파괴 및 ULTC 고장 등이 발생하는 것으로 밝혀졌다. 따라서 한전에서는 변압기 중성점으로 흐르는 지락고장전류의 저감을 위해 변압기 중성점 접지 리액터(NGR: Neutral Ground Reactor)를 설치하여 운전하고 있으며, 결과 변압기 고장이 크게 감소하였다. 그러나 모선 절체시 변압기 1, 2차측 차단기 Trip 고장이 발생하였으며, 고장 발생 원인은 NGR 보호계전기 59GT 계전기의 오동작에 의한 86T Lock Out 계전기 동자으로 변압기 1, 2차측 차단기 Trip 고장이 발생한 것으로 추정된다. 따라서 본 논문에서는 무부하 모선 차단시 59GT 계전기에 나타나는 이상 전압을 EMTP (electro-magnetic transient program)를 이용하여 분석하였다.

  • PDF

Flywheel Energy Storage UPS with Voltage Compensation (플라이휠 저장 에너지를 이용한 무순단 전압보상 기능을 갖는 UPS)

  • Lee K. S.;Kim J. W.;Chun T. W.;Kim I. D.;Kim H. G.;Lee H. H.;Nho E. C.
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.3
    • /
    • pp.241-247
    • /
    • 2005
  • This paper deals with the operation of a flywheel energy storage UPS. The UPS has good features such as long life-time, improved efficiency, no environmental problems, reduced size and space, and low maintenance cost compared with the conventional UPS using battery. The operating principle of the UPS is analysed in each mode including voltage compensation as well as uninterruptible power supply. Especially, the tracking characteristic of the disturbed phase of the source voltage after outage is analysed. The usefulness of the system is proved through simulations and experiments.

Loop power flow Analysis of Distribution lines Between Substations (변전소간 배전선로 Loop 조류 검토)

  • Jeon, Sang-Dong;Kim, Gi-Il;Jeong, Kyu-Won;Ryu, Hee-Young;Lee, Bong-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.169-170
    • /
    • 2008
  • 최근 전력수요의 증가 및 부하 고밀도화에 효과적으로 대응하고 배전설비 투자비용의 절감을 통한 경영효율성 증진을 위해 전배전선로를 대상으로 배전선로의 상시운전용량과 비상시운전용량을 상향조정하였다. 도심번화가 공단 등 부하밀집지역, 선로전압 유지곤란지역 및 경과지 확보가 곤란한 지역에 대용량 배전방식을 채택하여 운영하고 있다. 이와 같은 배전계통 운전 용량의 큰 변화에 따라 전력회사에서는 일선사업소의 모든 배전계획자들이 배전계획 및 운영시 배전계통의 설비를 가장 효율적으로 이용할 수 있도록 모든 배전선로에 대하여 배전용변전소, 주변압기, 인접 2회선 등의 상정사고 및 작업시에도 건전정전구간이 발생하지 않도록 부하를 융통할 수 있는 연계 기준이 마련되어 있다. 본 논문에서는 배전선로의 루프운전의 조건가능 여부를 보다 정확하고 신속한 방법으로 사전에 검토하여 고장을 예방하고자 한다.

  • PDF

An feeder Automation System Using Active Database (능동 데이터베이스 이용한 배전선로 운전자동화)

  • 최상열
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.5
    • /
    • pp.94-102
    • /
    • 2003
  • This paper presents active management of feeder automation systems using active database. DAS(Distribution Automation System) has been managed for feeder automation in passive manner. Therefore, feeder automation system has to be managed by operator when feeder overloadings is detected. It may be possible for propagating the feeder overloadings area by operator's mistake. To overcome this defect, the author proposed the feeder automation technique with active manner to obtain feasible feeder reconfiguration. Active database can manage feeder automation system by data driven monitoring of events and by corresponding actions without operator's intervening. To manage feeder automation system with active manner, production rule, active rule manager are designed. And active database system architecture for feeder automation system is proposed. Test results on the KEPCO's 108 bus distribution system show that the performance is efficient and robust.

A Study on the Characteristics and Fabrication of Switching Power Module for High Efficiency and Small Size of Power Supply System (전원장치의 소형화와 고효율화를 위한 스위칭 파워 모듈의 제작과 특성에 관한 연구)

  • Kim, Chan;Jeon, Eui-Seok;Kang, Do-Young;Kim, Byung-Cheul
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.10a
    • /
    • pp.758-761
    • /
    • 2003
  • We have designed 5 V/500 mA transless type power module by using semiconductor switching technique, key technique for small size of power supply system. The power module is suitable to a small sized electronic system using a single power supply. It is composed of switching circuit using voltage drop type chopper method, control circuit, voltage detect circuit, and constant voltage circuit, and is fabricated to hybrid-IC type. The switching regulator power supply circuit, designed in this study, has satisfied the electrical characteristics of 5 V/500 mA transless type power module.

  • PDF

Microgrid Island Operation Based on Power Conditioning System with Distributed Energy Resources for Smart Grid (스마트 그리드를 위한 분산자원과 전력변환장치 기반 마이크로그리드 독립운전)

  • Heo, Sewan;Park, Wan-Ki;Lee, Ilwoo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.42 no.5
    • /
    • pp.1093-1101
    • /
    • 2017
  • Microgrid as a unit component consisting a smart grid is an isolated system, which has a decentralized power supply system. This paper proposes an electrical isolation of the microgrid from the utiliy grid based on a power conditioning system, and also proposes an operation method maintaining the isolated state efficiently using diverse distributed energy resources such as renewable energy sources and energy storage system. The proposed system minimizes the influence of the grid connection on the internal load though a phase detection and synchrnoization to the utiligy grid and the microgrid can be stable even if the grid is failed.

Investigation on Galvanostatic Method to Protect Cavitation-corrosion Damage for Cu Alloy in Sea Water (해양환경 하에서 동합금의 캐비테이션-부식손상 방지를 위한 방식정전류 기법 연구)

  • Park, Jae-Cheul;Kim, Seong-Jong
    • Journal of Surface Science and Engineering
    • /
    • v.45 no.1
    • /
    • pp.25-30
    • /
    • 2012
  • The galvanostatic tests for corrosion protection are conducted at various applied current densities during 93,600 sec, and evaluated in terms of the variations in current density with time and in the potential at the applied current density. In addition, the corrosion damage depth is analyzed with 3D analysis optical microscope after galvanostatic tests. In this study, it was investigated to decide condition of the corrosion protection gavalnostatic method for Cu-Al alloy that has an excellent corrosion resistance. In the galvanostatic test under the cavitation environment, the energy was reflected or cancelled out by the collision with the oxygen gas generated by the oxygen reduction action. The surface observation showed neither the cavitation damage nor the electrochemical damage in the current density over 0.01 $A/cm^2$ in the dynamic state under the cavitation environment.

A Study on the Safety Security of Emergency Power for Fire Fighting (소방용 비상전원 안전성 확보에 관한 연구)

  • Lee, Won-Kang;Choi, Chung-Seog
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.133-136
    • /
    • 2012
  • 본 논문에서는 소방용 비상전원 안전성 확보에 관한 것으로서, 과부하 조건 회피를 위한 인터록 시스템 및 기타 방법의 한계점을 분석하여 최근 제도적으로 도입된 소방전원보존형 발전기의 필요성과 타당성을 확인하고 나아갈 방향을 제시하는데 있다. 소방부하 및 비상부하 겸용의 자가발전설비에서 어느 한쪽의 용량으로만 택일하여 설치할 경우 정전 및 화재 발생 시 발전기 용량 초과로 비상전원 공급 중단과 소화설비의 미작동의 위험이 초래된다. 소방시설에 비상전원의 안전한 공급을 목적으로 하는 소방전원보존형 발전기는 과부하에 도달되면 소방전원보존용 컨트롤러에서 신호를 발신하여 소방부하는 남겨두고 비상부하의 일부 또는 전부를 차단하고, 소방부하에 비상전원이 연속적으로 공급하고 그 작동 상태가 표시되는 표시장치를 특징을 가진 시스템이다. 소방 안전을 확보하는 제도는 안전을 위한 행정적인 절차와 기준을 지킴으로써 기술적인 안전성이 보장되도록 하는 방식으로 운용되고 있다. 이에는 확인 절차가 필수적으로 요구되는 것이다. 임의의 구두 진술로나 이와 다름없는 임의적인 서류로만 인정할 수는 없는 것이며, 그럴 경우 제도에 의한 소방 안전 확보의 보장성이 무너지기 때문이다.

  • PDF