• Title/Summary/Keyword: 정적 시험

Search Result 655, Processing Time 0.027 seconds

Analytical Study on the Pullout Resistance Characteristics of Bored Pile (매입말뚝의 인발저항특성에 관한 연구)

  • Park, Jong-Bae;Chun, Young-Soo
    • Land and Housing Review
    • /
    • v.7 no.4
    • /
    • pp.281-289
    • /
    • 2016
  • Structural experiment result showed that PHC(d=600mm) Pile used as a common compression member could resist 83.6 ~ 91.6 tonf of ultimate tension force, if the adhesion of P.C. bar of PHC pile to the concrete foundation is strengthened. Considering a proper safety factor to ultimate tension strength, PHC pile can substitute the anti-floating anchor, or reduce the number of anchors. For this purpose, pullout resistance behavior of a Bored pile embedded in real ground as well as structural tension strength of PHC pile must be evaluated. This study performed the static pullout tests to evaluate the pullout behavior of bored pile, and compared the test results with design value of side resistance. To evaluate the pullout resistance easily, static pullout test results were compared with dynamic loading test results using PDA. As a result, cement paste of the bored pile was hardened which is after 15 days, LH side resistance design value corresponded well to the Static pullout test results, also to the side resistance evaluated by dynamic loading test.

A Study on the Static Performance Test of a Reciprocating Engine for Small Aircraft (소형항공기용 왕복엔진의 정적 성능시험 연구)

  • 김근배;안석민;김근택;최선우
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.7 no.3
    • /
    • pp.53-60
    • /
    • 2003
  • A test stand was developed to measure static performance of a reciprocating engine on the ground, related to the small aircraft being developed by KARI. The test stand consists of an apparatus to install and operate a pusher-type propulsion system and a data acquisition system to process many performance parameters including engine torque and propeller thrust as well as monitoring of the engine operations. First, the performance data from the basic operation tests were compared with the original engine data so the capacity of the test stand was verified. Engine performance tests were carried out with various test conditions through three stages, and it was measured and analyzed that the manifold pressure, the torque, and the back pressure of the engine, and the static thrust of the propeller.

Development of Precast Slab Track Reinforced with GFRP and Analysis of Behavior (GFRP로 보강된 프리캐스트 슬래브 궤도 개발 및 거동분석)

  • Zi, Goang-Seup;Lee, Seung-Jung;Moon, Do-Young;Kim, Yoo-Bong;Baek, In-Hyuk
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2072-2076
    • /
    • 2011
  • 철도 시스템에서 철도궤도와 레일은 주요한 신호 시스템의 일부로 사용되고 있으나 콘크리트 슬래브 궤도 내부의 철근으로 인한 신호전류 감소, 교란 등을 방지하기 위해 과도한 절연작업이 필요하다. 본 연구에서는 국내에서 기 개발된 프리캐스트 슬래브 궤도의 횡방향 철근을 GFRP 보강근으로 대체하여 절연작업의 감소를 가능하게 하였다. GFRP로 보강된 프리캐스트 슬래브 궤도의 설계과정과 정적 휨 시험과 단부의 연결철근 인발 시험을 통한 거동 분석 및 고찰 내용을 제시하였다. 휨 시험과 실스케일 인발 시험의 결과 정적 휨 강도는 정립된 설계법에 의해 적절한 강도를 가지고 있으나 기 개발된 연결철근의 위치와 형태는 온도 또는 수축으로 인해 발생할 수 있는 축력을 저항할 수 없음을 확인하였다.

  • PDF

A Constitutive Equation Including Strain Rate Effect for the Expanded Polypropylene (변형률 속도가 고려된 발포 폴리프로필렌의 구성방정식)

  • Kim, Han-Kook;Cheon, Seong S.
    • Composites Research
    • /
    • v.27 no.4
    • /
    • pp.130-134
    • /
    • 2014
  • The purpose of this paper is to build DB in order to Propose new constitutive equations by redefining constitutive equations for Polyurethane presented by Jeong et al. [12] based on Quasi-static test and Impact test DB of Expanded polypropylene using cylindrical specimens with 4 different densities presentsd by Kim et al. [7] for EPP foam and combining the impulse-momentum theory.

Effects of Transducer Position in Ultrasonics Nondestructive Tests of Finger-Jointed Lumber (손가락결합부재에 대한 초음파 비파괴시험에서 센서 위치의 영향)

  • Jang, Sang-Sik
    • Journal of the Korean Wood Science and Technology
    • /
    • v.26 no.1
    • /
    • pp.1-6
    • /
    • 1998
  • 손가락결합부재에 대한 정적휨시험 및 초음파 비파괴시험을 실시하였다. 발신 및 수신 변환기의 상대 위치와 두 변환기 사이의 거리에 따른 음전달속도의 변화를 분석하였으며 정적 휨시험으로 부터 구한 MOE 및 MOR과 비교하였다. MOR과 음전달속도는 손가락의 경사가 증가할수록 감소하였다. MOR은 음전달속도와 매우 밀접한 상관관계를 보였으나 MOE는 손가락의 경사도나 음전달속도에 큰 영향을 받지 않는 것으로 나타났다. 음전달속도는 섬유방향이 방사방향이나 접선방향에 비하여 더 높은 값을 나타내었다. 발신 및 수선 변환기를 동일면에 부착한 경우에 직각면 또는 반대면에 부착한 경우보다 더 높은 음전달속도를 나타내었다. 변환기 사이의 거리가 증가할수록 음전달속도는 양끝면에 변환기를 부착한 경우의 속도에 수렴하는 경향을 나타내었다.

  • PDF

Characteristics of Undrained Static Shear Behavior for Sand Due to Aging Effect (Aging 효과에 따른 모래의 비배수 정적전단거동 특성)

  • 김영수;김대만
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.6
    • /
    • pp.137-150
    • /
    • 2004
  • Aging effect of sands showed insignificant result in comparison with that of clay, so that it has not been studied so far. But, as penetration resistance increase has been observed with the lapse of time after deposition and disturbance, aging effect of sands has been actively investigated by field tests, and recently many researchers are performing not oかy field tests but also laboratory tests on sands, so aging effects of sands have been also examined by laboratory tests. In this study, to observe the aging effect of undrained static shear behavior for Nak-Dong River sand, undrained static triaxial tests were performed with changing relative density$(D_r)$, consolidation stress ratio$(K_c)$, and consolidation time. These tests showed that modulus within elastic section increased as consolidation time increased, and in addition, phase transformation point strength$(S_{PT})$ and critical stress ratio point strength $(S_{CSR})$ also increased. But pore water pressure ratio$(u/{p_c}')$ decreased as consolidation time increased, so with this various result, aging effect of static shear for sands can be observed as well.

Evaluation of the Load Carrying Capacity of Existing Bridges with Long Span Hollow Web Prestressed Concrete Girder by Static Load Test (정적재하시험을 통한 장경간 중공 웨브 PSC 거더교의 내하력 평가)

  • Kim, Seong-Kyum;Jang, Pan-Ki;Jang, Il-Young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.3
    • /
    • pp.97-102
    • /
    • 2018
  • Conventional PSC I type girders were adversely affected by the self - weight of concrete, anchorage, prestressing. In order to overcome this problem, PSC girder was constructed with a hollow in the web and developed a hollow web PSC type I girder which is applicable to 50 - 70m span by multistage stressing and then actually long span hollow web PSC girder bridge was constructed. In this study, the results of Static Load Test and the Finite Element Analysis of the hollow web PSC I girder bridges were compared and analyzed, and the Load Carrying Capacity and safety of PSC girder bridges were evaluated. The Static Load Test and the numerical analysis results of this bridge showed similar tendency and the behavior of the hollow web PSC I girder was well simulated. The entire girders of the bridges had sufficient Load Carrying Capacity under the live load design condition and the bridges satisfied the safety and confirmed the appropriateness of the construction.

KC-100 Full-scale Airframe Static Test (KC-100 전기체 정적 구조시험)

  • Shim, Jae-Yeul;Jung, Keunwan;Lee, Hanyong;Lee, Sang Keun;Hwang, Gui-Chul;Ahn, Seokmin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.1
    • /
    • pp.67-75
    • /
    • 2014
  • A full-scale static test for a composite structure small aircraft (KC-100) was conducted in the KARI. The test includes 15 full-scale test and 7 local test conditions. Test requirements with test schedule, test article with dummy structures, test load generation, test system, and equipment are introduced for the test. Test load data of the 1st test condition(U1) was analyzed to evaluate an accuracy of load control for the test. The analysis results show that load data obtained during test were within tolerance of Static Null Pacing Error(SNPE) and the error value of load control was 8.6N. The error of load controls for the full-scale static test using dozens of actuators was calculated by a method suggested by authors. Test data for all other test conditions is also shown in this paper. Finally, reactions measured from restraint system of the U1 test condition show that the reaction changes as load increment. The factors which may change the change of reactions for a full-scale static test are introduced in this study.

On Quasi-Static Crushing of a Stiffened Square Tube (보강된 정사각형 단면 강관의 정적 압괴거동에 관한 연구)

  • Paik, Jeom Kee;Chung, Jang Young;Chun, Min Sung
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.33 no.1
    • /
    • pp.109-123
    • /
    • 1996
  • A series of quasi-static crushing tests were carried out on thin-walled square tube specimens with axial and/or circumferential stiffeners including unstiffened specimens. The effective crushing length and mean crushing strength of the test specimens were investigated. Using the equivalent plate thickness approach, a simplified analytical model for predicting the mean crushing strength of stiffened square tubes has been developed.

  • PDF