• Title/Summary/Keyword: 정적 시험

Search Result 655, Processing Time 0.025 seconds

Static Conformance Test of MPEG-4 Visual Decoders Using Test Bitstreams (시험 비트열을 이용한 MPEG-4 텍스처 디코딩의 정적 Conformance Test)

  • Kim, U-Sik;Park, In-Su;Park, Su-Hyeon;Lee, Byeong-Uk;Park, Rae-Hong
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.38 no.1
    • /
    • pp.69-78
    • /
    • 2001
  • MPEG-4 visual conformance standard specifies methods to verify whether bitstreams and decoders meet the requirements at the specified profile and level. The test of decoders can be divided into two parts: the static test and the dynamic test. The static test can be performed by examining the decoder output with that of a reference decoder. This paper proposes design methods of test bitstreams for static test of texture decoding, and shows the test results.

  • PDF

Analytical Study on Software Static/Dynamic Verification Methods for Deriving Enhancement of the Software Reliability Test of Weapon System (무기체계 소프트웨어 신뢰성 시험 개선점 도출을 위한 소프트웨어 정적/동적 검증 분석 사례연구)

  • Park, Jihyun;Choi, Byoungju
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.8 no.7
    • /
    • pp.265-274
    • /
    • 2019
  • The reliability test performed when developing the weapon system software is classified into static test and dynamic test. In static test, checking the coding rules, vulnerabilities and source code metric are performed without executing the software. In dynamic test, its functions are verified by executing the actual software based on requirements and the code coverage is measured. The purpose of this static/dynamic test is to find out defects that exist in the software. However, there still exist defects that can't be detected only by the current reliability test on the weapon system software. In this paper, whether defects that may occur in the software can be detected by static test and dynamic test of the current reliability test on the weapon system is analyzed through experiments. As a result, we provide guidance on improving the reliability test of weapon system software, especially the dynamic test.

KC-100 Full-scale Static Test System (KC-100 전기체 정적 구조시험 장치)

  • Shim, Jae-Yeul;Lee, Sang-Geun;Ahn, Seok-Min
    • Aerospace Engineering and Technology
    • /
    • v.11 no.1
    • /
    • pp.7-18
    • /
    • 2012
  • Full-scale static test was introduced for the KC-100 aircraft which is domestic civil aircraft to be certified for the first time. Test requirement, test frame, and important test stystems such as loading system, counterbalance system, restraint system and jacking system are explained in detail. Especially, the way to satisfy compliance for the installation of test article and loading system is introduced by using check sheets for the installations. 15 Full-scale and 7 local test conditions were successfully completed and the test data was obtained.

An Efficient Software Reliability Testing Method for the Model based Embedded Software (모델 기반 내장형 소프트웨어의 효율적 신뢰성 시험 기법)

  • Park, Jang-Seong;Cho, Sung-Bong;Park, Hyun-Yong;Kim, Do-Wan;Kim, Seong-Gyun
    • Journal of the Korea Society for Simulation
    • /
    • v.27 no.1
    • /
    • pp.25-32
    • /
    • 2018
  • This paper presents an efficient software reliability testing method for the model based auto-generated code and reify a dynamic test procedure. The benefits of executing the model-based each static/dynamic reliability test before the code-based static/dynamic reliability test are described. Also, The correlations of code/model based reliability test are demonstrated by using model testing tool, Model Advisor and Verification and Validation, and the code testing tool, PolySpace and LDRA. The result of reliability test is indicated in this paper.

Static Behavior Analysis of Spillway Pier for Dam Safety Evaluation (댐 안전성 평가를 위한 여수로 피어부의 정적 거동 분석)

  • Jang, Bong-Seok;Lim, Jeong-Yeul;Lee, Myung-Kue;Lee, Hyung-Jun
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.1
    • /
    • pp.11-18
    • /
    • 2007
  • Seismic performance evaluation for dam safety evaluation has been continually conducted. However the behavior analysis for the spillway pier which is known as the weak point of dam is seldom reported. Therefore, this study performed the static loading tests for a prototype structures as elementary tests for the final seismic performance evaluation of dam safety. The prototype of pier structure has 1/20 scale and it adopts to strength model. And cracking loads and ultimate loads of real structures are calculated through numerical analysis using commercial FEM program (ABAQUS). The results of this study show some difference between the results of prototype tests and the results of numerical analysis. Also, the ultimate and cracking loads can be estimated through the prototype loading test and numerical analysis.

Experimental study on Static Behavior of H-beam prestressed with Multi-Stepwise TPSM (다단계 온도프리스트레싱 도입 강재보의 정적거동평가를 위한 실험적 연구)

  • An, Jin Hee;Jung, Chi Young;Kim, Jun Hwan;Kim, Sang Hyo
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.2
    • /
    • pp.247-258
    • /
    • 2008
  • In this study, static loading tests were performed on H-beam specimens to assess the static behavior of H-beam prestressed with multi-stepwise thermal prestressing method (TPSM). The amount of induced thermal prestress and connection type were differentiated among the 400-mm-high and 6,000-mm-long H-beam specimens to evaluate their effect on the behavior of the beams. From the experimental results, it between the H-beam and the cover-plate increased in yielding load by 13~18%, whereas stiffness increased by 27~34%. In case of specimens with both bolting and welding connection, yie lding load increased by 18~29% and stiffness increased by 43~51%. Multi-stepwise initial stress distribution was also observed from the prestressed specimens, verifying the effectiveness of the multi-stepwise TPSM. By application of the multi-stepwise TPSM, a significant increase in yielding load and stiffness can be achieved, hence increasing sectional and prestressing efficiencies.

Lateral Load Distribution Estimation of a PSC Girder Bridge from Dynamic Loading Test (동적재하시험을 통한 PSC 거더교의 횡분배 측정)

  • Kim, Sung-Wan;Cheung, Jin-Hwan;Kim, Seong-Do;Park, Jae-Bong;Lee, Myoung-Jin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.3
    • /
    • pp.60-68
    • /
    • 2017
  • Since the bridge is the main facility of the road that is the core of the civil infrastructure, the bridge is constructed to ensure stability and serviceability during the traffic use. In order to secure the safety of bridges, evaluating the integrity of bridges at present is an important task in the maintenance work of bridges. In general, to evaluate the load carrying capacity of bridges, it is possible to confirm the superimposed behavior and symmetric behavior of bridges by estimating the lateral load distribution factor of the bridges through vehicle loading tests. However, in order to measure the lateral load distribution factor of a commonly used bridge, a static loading test is performed. There is a difficulty in traffic control. Therefore, in this study, the static displacement component of the bridge measured in the dynamic loading test and the ambient vibration test was extracted by using empirical mode decomposition technique. The lateral load distribution was estimated using the extracted static displacement component and compared with the lateral load distribution factor measured in the static loading test.

Behavioral Characteristics of Precast Concrete Slab using Wheel Load Tester (윤하중 시험 차량을 활용한 프리캐스트 콘크리트 바닥판의 거동 특성)

  • Park, Seok-Soon;Kim, Nak-Seok
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.1
    • /
    • pp.29-34
    • /
    • 2010
  • The main objective of this research is to present the behaviors of precast concrete slab under moving wheel loads. The simulated moving wheel tester and precast concrete slab were designed for this research. In particular, a comparative analysis between the structural analysis and the moving wheel load test was evaluated in connection parts, deformation, bedding layer of concrete slab panels. In the comparisons of the test results from static and moving wheel loads, the maximum deformations were similar. It should be noted that the deformation of panel 2 from the static loading test was larger than that of other panels, while the deformations of panels 1 and 3 were more noticeable than that of panel 2.

Development of Full-Scale Static Test System for Aircraft Sensor Pod (항공용 센서 포드의 정적 구조시험장비 개발)

  • Jae Myung Cho;Hoon Hyuk Park;Won Woong Lee;Jong In Bae;Han Sol Lee;Eui Hwan Oh
    • Journal of Aerospace System Engineering
    • /
    • v.17 no.1
    • /
    • pp.97-105
    • /
    • 2023
  • For aviation sensor pod, structural integrity should be verified through static structural tests for flight loads induced in various maneuvering conditions of the aircraft. For this, it is necessary to develop a test system for full-scale static load test of sensor pod. Based on test requirements, this paper introduced a test system configuration of the static test and the development of test structure frame, restraints equipment, loading equipment, control, and measurement equipment. In addition, methods and procedures for verifying the developed test system were explained. In conclusion, the static load test and data acquisition were successfully performed. Reliability of the test equipment was also verified in the process.

Static Test of a Composite Wing with Damage Tolerance Design (손상 허용 설계를 적용한 복합재 날개의 정하중 시험)

  • Park, Min-Young
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.6
    • /
    • pp.471-478
    • /
    • 2018
  • Static tests of the composite wing structure were performed to verify damage tolerance design. Both 5 cases of DLLT and 3 cases of DULT were completed to meet requirements for static strength. After inducing BVID and open hole damages on the critical areas of the composite wing based on associated regulations, the DULT and fracture test were performed. In major wing parts, the measured strains and displacements agreed well with those of structural analysis. The initial structural fracture occurred at the area having minimum margin of safety as expected by analysis. As a result, it was confirmed that results from analytic model and strength evaluation were similar to behaviors of the composite wing structure.