• Title/Summary/Keyword: 정수 수질

Search Result 270, Processing Time 0.029 seconds

Constructing the Operating Information System(OIS) and Improving the Water Quality by OIS in Water Treatment Plants (수도시설 운영정보화 시스템 구축 및 효율개선효과)

  • Oh, Jung-Woo;Song, Yoon-Seob;Kang, Geum-Bai;Yoo, Man-Sik
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.6
    • /
    • pp.699-705
    • /
    • 2007
  • In this study, the improvement of the operation condition and the water quality in water treatment plant by operating information system(OIS) was evaluated for Ansan water treatment plant. The average flow rate of raw water in the year 2005(after constructing the OIS) appeared 15.6 % lower than that in the year 2004(before constructing the OIS). The mean value(12.37 NTU) of raw water turbidity in the year 2005 remained constant, or nearly so with that(12.06 NTU) in the year 2004. The average dosing rates of coagulant appeared 12.06 mg/L in the year 2005 which was higher than 10.31 mg/L in the year 2004. Furthermore, the average turbidity concentration of fresh water in the year 2005 appcared slightly better than that in the year 2004. From $COD_{Mn}$ and BOD concentration of raw water, the water quality in the year 2005 were better than those in the year 2004. The average concentration of $KMnO_4$ in the year 2004 and the year 2005 was 2.95 mg/L and 1.25 mg/L, respectively, and the average concentration of THMs in the year 2004 and the year 2005 appeared 0.038 mg/L and 0.025 mg/L, respectively. Therefore, the fresh water quality in the year 2005 was better than that in the year 2004. In this study, it is considered that the operation of Ansan water treatment plant may be optimized by OIS, and thus the OIS may be very useful method to improve the water quality.

Water Quality Variation on the Unit Operation of Water Treatment Process When CCPP Index was Controlled for Internal Corrosion of Water Pipes (수도관 내부부식방지를 위한 CCPP 조절시 정수공정내에서의 수질변화)

  • Lee, Jae-In;Kim, Do-Hwan;Lee, Ji-Hyung;Kim, Dong-Youn;Hong, Soon-Heon;Shin, Pan-Sae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.4
    • /
    • pp.362-368
    • /
    • 2005
  • The pH, alkalinity and calcium hardness could be adjusted by $CO_2$, $Ca(OH)_2$, and $Na_2CO_3$ addition in the water treatment process for corrosion protection of the water pipes. This research was performed to investigate the effect on the variation of water quality on the unit process by addition $CO_2$, $Ca(OH)_2$, and $Na_2CO_3$ in water treatment process. Carbon dioxide and lime were added before the coagulation basin and soda ash was added after the BAC process. pH and aklainity were increased at coagulation basin then after the water qualities had sustained similiarly to BAC process. There was no effect on turbidity and DOC removal efficiency during experimental period by addition\ $CO_2$, $Ca(OH)_2$, and $Na_2CO_3$ solution was added into clear well, the last process for optimum control of CCPP and is used mainly to control pH and alkalinity. In this research, average pH, alkalinity, and calcium hardness in treated water were 8.39, 61.4 mg/L as $CaCO_3$, 59.4 mg/L as $CaCO_3$, respectively and CCPP of treated water was higher than 29.5 mg/L to BAC process water, so adjusted water was expected to prevent internal corrosion of water pipe.

Development of Web Based Water Pollution Accident Response Management System in Rivers (Web 기반 하천의 수질오염사고 대응예측시스템 개발)

  • Mun, Hyun-Saing;Kim, Joo-Young;Jang, Joo-Hyung;Ryu, In-Gu;Kim, Kyung-Hyun
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.48-48
    • /
    • 2011
  • 우리나라는 최근 4대강 살리기 사업의 보 건설로 인하여 하천의 수리특성이 크게 변화되고 있어 새로운 하천 환경변화가 충분히 반영된 수질오염사고 대응시스템의 구축이 필요하다. 국내 하천의 오염사고는 매년 50여건 발생하고 있으며, 2008년 김천 유화공장 화재로 인한 페놀유출사고는 이동시간의 예측오류로 취 정수장의 사전대응에 상당한 혼란이 발생되어 먹는 물 공급에 상당한 어려움이 발생되었다. 이러한 시점에서 본 연구에서는 하천의 유역환경변화를 반영하고 실시간으로 오염물질의 이동시간과 확산농도를 예측하기 위한 수질오염사고대응예측시스템을 개발하였다. 본 시스템은 평상시 4대강의 본류 및 주요 지방 1 2급 하천에 대해 수리모델을 매일 업데이트하고, 3차원 수리 수질모형인 EFDC의 독성모듈을 개선하여 예측모델로 사용하고 있으며, 최적방제방법을 선정하기 위해 상류 댐, 보, 농업용저수지 방류량 등을 분석할 수 있도록 구성되어 있다. 시스템의 예측결과는 방제기관, 취 정수장 등의 사전대응 능력을 높이는 데 기여할 것이다.

  • PDF

Microbiological Water Quality of Water Purifiers at Elementary Schools in Gunsan Area (군산지역 초등학교 정수기 물의 미생물학적 수질)

  • Seo, Lan-Ju;Park, Suhk-Hwan;Lee, Geon-Hyoung
    • Korean Journal of Microbiology
    • /
    • v.45 no.1
    • /
    • pp.74-81
    • /
    • 2009
  • In this research, we investigated the actual conditions of water purification systems at ten elementary schools located in Gunsan, Korea from July to December, 2007. The results were as follows; The population densities of heterotrophic bacteria in water purifiers ranged from 0 to $1.2{\pm}0.2{\times}10^4$ CFU/ml and those of tap water were in the range from 0 to $1.9{\pm}0.3{\times}10^4$ CFU/ml during investigation periods. Ninety percentage of purified water samples in July and September, 87.2% in October and November, and 93.7% in December turned out not to be suitable for drinking. The seasonal variation of the population densities of heterotrophic bacteria from purified waters was not notable. The total coliform, Salmonella and Shigella were not detected in purified water and tap water during investigation periods. Forty-five species of bacteria were isolated from water purifiers. The identified bacterial genera were Sphingomonas, Methylobacterium, Caulobacter, Novosphingobium, Bosea, Brevundimonas, Aminobacter, Ralstonia, Mitsuaria, Variovorax, Acidovorax, Massilia, Pseudomonas, Acinetobacter, Aeromonas, Bacillus, Staphylococcus, Brevibacillus, Microbacterium, Lapillicoccus, Micrococcus, Arthrobacter, Janibacter, Flavobacterium, Chryseobacterium, and Hymenobacter: Among the isolates, opportunistic pathogens such as Pseudomonas fluorescens, Staphylococcus epidermidis, Flavobacterium johnsoniae, and Acinetobacter johnsonii were also found.

Treated Water Quality Characteristic of Small Scale Water Works in West Gyeong-Nam (서부경남지역 소규모 급수시설의 정수 수질특성 조사에 관한 연구)

  • Park, Hyungeoun;Kim, Kyungmi
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.7
    • /
    • pp.454-458
    • /
    • 2012
  • The Characteristics of small scale water works at west Gyeong-nam was analyzed by investigationg the 6,569 cases which were carried out from Jan. 2005 to Dec. 2010. The result of the research about treated water quality the highest mean concentration of fluorine was 0.19 mg/L at Hamyang the highest mean concentration of Nitrite nitrogen was 3.7 mg/L at Namhae each the highest mean concentration of Hardness, Total solids, Sulfate was 177 mg/L, 271 mg/L, 80 mg/L at Uiryeong. In the case of waterworks originated from valleys, the total bacterial count and turbidity were higher than ones originated from groundwater. On the other hand, nitrate nitrogen, total solids, hardness, sulfate, fluorine and iron were detected more than ones originated from valleys.

Evaluation of Membrane Module on the Basis of the Domestic Water Quality (국내 먹는 물 수질에 따른 막모듈의 적합성 검토)

  • 권영남;최중구;김종호;탁태문
    • Membrane Journal
    • /
    • v.8 no.4
    • /
    • pp.220-227
    • /
    • 1998
  • Recent data from Environmental department show that some out of 2,000 places surveyed are contaminated by nitrate, ammonia, fluoride, chloride and so forth in excess of the environmental standard-including purification plants, water taps, small water supply systems. In this study, some items which exceed drinking water standard were chosen and their concentrations were made varying from around standard level to around detected maximum concentration. After they permeated through the membrane module sold in the domestic market and made for household water-purifier, the most suitable membranes were selected according to individual water quality of various regions. In addition, the bacterial growth after storage for various days and under various temperatures was examined for the purpose of the effect of the time and temperature on bacterial growth.

  • PDF