• Title/Summary/Keyword: 정류기 기술

Search Result 95, Processing Time 0.025 seconds

The Power Converter Circuit Characteristics for 3 kW Wireless Power Transmission (3 kW 무선 전력전송을 위한 전력 변환기 회로 특성)

  • Hwang, Lark-Hoon;Na, Seung-kwon;Kim, Jin Sun;Kang, Jin-hee
    • Journal of Advanced Navigation Technology
    • /
    • v.24 no.6
    • /
    • pp.566-572
    • /
    • 2020
  • In a wireless power transmitter, the characteristics and effects of wireless power transmission between two induction coils are investigated, and a power converter circuit and a battery charger/discharger circuit using wireless power transmission technology are proposed. The advantage of wireless power transmitters and wireless chargers is that, instead of the existing plug-in-mounted wired charger (OBC; on-board charger), the user can wirelessly charge the battery without connecting the power source when charging power to the battery. There is. In addition, the advantage of wireless charging can bring about an energy efficiency improvement effect by using the secondary side rectifier circuit and the receiving coil, but the large-capacity long-distance wireless charging method has a limitation on the transmission distance, so many studies are currently being conducted. The purpose of the study is to study the transmitter circuit and receiver circuit of a wireless power transmission device using a primary coil, a secondary coil, and a half bridge series resonance converter, which can transmit power of a non-contact type power transmitter. As a result, a new topology was applied to improve the power transmission distance of the wireless charging system, and through an experiment according to each distance, the maximum efficiency (95.8%) was confirmed at an output of 3 kW at an 8 cm transmission distance.

Current Unbalance Improved Half-bridge LLC Resonant Converter using the Two Transformers (두 개의 변압기를 이용한 전류불균형 개선 하프브리지 LLC 공진형 컨버터)

  • Yoo, Doo-Hee;Jeong, Gang-Youl
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.2
    • /
    • pp.497-507
    • /
    • 2010
  • This paper presents current unbalance improved half-bridge LLC resonant converter using the two transformers with different leakage inductances. The proposed converter resonates with the leakage inductance and magnetizing inductance of the transformer and the resonant capacitance. The converter operates in a wide load range and satisfies the zero voltage switching even under the light load. The series-parallel connected two transformers act as the transformers or the resonant inductances according to the operational modes, and the separate output filter inductance in the transformer secondary is not needed using the leakage inductance. The current unbalance of the secondary diode rectifier is improved using the different leakage inductances of the two transformers and the asymmetrical pulse-width modulation (PWM). In this paper, the operational principle of the converter is explained by the modes, and the design example for the prototype is also shown. To validate the performance of the converter, the prototype is implemented as the designed circuit parameters and the good performance of the proposed converter is shown through the experimental results

Development of an Electronic Ballast for 70W Ceramic Discharge Metal Halide Lamps with Step Down Converter (강압형 컨버터를 이용한 70W CDM 램프용 전자식 안정 기의 개발)

  • 김일권;길경석;김진모
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.6 no.7
    • /
    • pp.1055-1061
    • /
    • 2002
  • This paper deals with a design and fabrication of an electronic ballast for 70[W] ceramic discharge metal halide lamps. The proposed ballast is composed of a rectifier, an active power factor correction circuit (PFC), a half-bridge inverter, a LC resonant circuit and a microprocessor. The developed ballast also includes a specially designed time circuit which provides reignition signal of lamps. Running frequency of the ballast is .jet at 40[kHz] to avoid acoustic-resonance and flickering. From the experimental results, input power factor and efficiency of the ballast are estimated 99.8[%] and 93.1[%], respectively.

Development of an Electronic Ballast for 70W Ceramic Discharge Metal Halide Lamps with Step Down Converter (강압형 컨버터를 이용한 70W CDM 램프용 전자식 안정기의 개발)

  • 김일권;길경석;김진모
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.11a
    • /
    • pp.435-439
    • /
    • 2002
  • This paper describes a design and fabrication of an electronic ballast for 70[W] ceramic discharge metal halide lamps. The proposed ballast is composed of a rectifier, an active power factor correction circuit (PFC), a half-bridge inverter, a LC resonant circuit and a microprocessor. The developed ballast also includes a specially designed time circuit which provides reignition of lamps. Running frequency of the ballast is set at 40[kHz] to avoid acoustic-resonance and flickering. From the experimental results, input power factor and efficiency of the ballast are estimated 99.8[%] and 93.1[%)] respectively.

  • PDF

Electric Fan Heater Design for Eco-Energy Saving (친환경 에너지 절감형 전기온풍기 기구설계)

  • Sul, Yong-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.4
    • /
    • pp.474-479
    • /
    • 2016
  • As the Eco-energy is recently required, electrical energy is fast increased. Several induction heating methods are attractive for Eco-energy and energy saving. In this paper, electrical fan heater was designed and developed with new concept for energy saving by electromagnetic induction heating. Proposed system was composed of three module, blast part, induction heating part and power transformation part. Induction heating method was adapted for heating and the resonant inverter was used for increasing of the power transformation efficiency. Full-bridge resonant inverter was adopted to resonant inverter. This system was composed of induction heating part made with metal(SUS 40 series), and power transformation part made with rectifier module, filter module and resonant inverter. From these results, the proposed new electric heater could be saved the energy from faster increasing the temperature compared to commercial gas and other electric heater. This electrical fan heater is possible to be used in field of home, commercial and agricultural area for eco-energy saving heater.

New VFT Grid-Connection System Including Reactive Power Compensation (무효전력 보상을 포함하는 새로운 회전형 변압기 계통 연계 시스템)

  • Oh, Jeong-Sik;Park, Tae-Sik;Kim, Sung-Hwan;Kwak, No-Hong;Park, Jang-Hyun
    • Journal of IKEEE
    • /
    • v.23 no.1
    • /
    • pp.143-150
    • /
    • 2019
  • The back-to-back HVDC asynchronous grid interconnect technology has problems of high harmonic generation, high cost, and low scalability. To solve this problem, research on asynchronous grid interconnect technology using VFT is actively being conducted. However, the reactive power due to the inductance component of the VFT is generated, and the problem of additional installation of the reactive power compensating facility is inevitably generated. Therefore, in this paper, we aim to solve the reactive power compensation problem of existing VFT by designing rectifier AC-DC converter, which is an essential element of the asynchronous grid connection system using VFT, to compensate reactive power as well as active power supply. The performance was verified through simulation.

A Study of LCD Panel Cleaning Effect of Plasma Generation Power Source (플라즈마 발생용 전원장치의 LCD 패널 세정효과에 관한 연구)

  • Kim, Gyu-Sik
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.45 no.5
    • /
    • pp.44-51
    • /
    • 2008
  • UV lamp systems have been used for cleaning of display panels of TFT LCD or Plasma Display Panel (PDP). However, the needs for high efficient cleaning and low cost made high voltage plasma cleaning techniques to be developed and to be improved. Dielectric-Barrier Discharges (DBDs), also referred to as barrier discharges or silent discharges have been exclusively related to ozone generation for a long time. In this paper, a 6kW high voltage plasma power supply system was developed for LCD cleaning. The 3-phase input voltage is rectified and then inverter system is used to make a high frequency pulse train, which is rectified after passing through a high-power transformer. Finally, hi-directional high voltage pulse switching circuits are used to generate the high voltage plasma. Some experimental results showed the usefulness of atmospheric plasma for LCD panel cleaning.

The Design of Auxiliary Power Supplies for 30kW, 95GHz Gyrotron (30kW, 95 GHz 자이로트론 구동을 위한 보조 전원장치 설계)

  • Seo, Jung-Ho;Jang, Sung-Roc;Ahn, Suk-Ho;Kim, Jong-Soo;Ryoo, Hong-Je
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.347-348
    • /
    • 2015
  • 본 논문은 30kW, 95GHz 자이로트론 구동을 위한 $25kV_{max}$, $10mA_{max}$ 출력 사양의 Body Power Supply (BPS)와 $10V_{max}$, $10A_{max}$ 사양을 가지며 50kV 절연이 요구되는 Heater Power Supply (HPS)의 설계에 관하여 기술한다. 자이로트론 구동 효율 향상에 필요한 BPS는 높은 승압비 달성 및 절연에 대한 신뢰성 확보를 위해 8개의 분리된 코어를 사용하여 변압기를 구성하고, 각 코어간의 보상권선을 이용하는 방식을 제안하여 직렬로 구성된 8개의 고전압 정류부 간의 전압 불균형 문제를 해결 한다. HPS는 50kV 전위가 인가되는 코일 가열을 위해 사용되는 전원으로 내부 고주파 변압기를 이용하여 효율적인 절연 설계를 구현한다. 30kW, 95GHz 자이로트론 구동 시스템의 신뢰성 확보와 전원장치의 높은 전력밀도 달성을 위해 두 전원장치는 공진형 컨버터 토폴로지를 기반으로 설계하고, 시뮬레이션 및 실험을 통해 개발된 전원의 우수성을 검증한다.

  • PDF

Development of a Low frequency Operating Electronic Ballast for Fish Attracting Lamps (저주파 구동형 집어등용 전자식 안정기 개발)

  • Kil Gyung-suk;Kim Il-kwon;Song Jae-yong;Han Ju-seop;Shin Gwang-chul
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.5
    • /
    • pp.1052-1058
    • /
    • 2005
  • This paper dealt with the design and fabrication of a low frequency electronic ballast for ruh attracting lamps. The proposed electronic ballast was composed of a full-wave rectifier, a step don converter operated as a constant power controled current source, an inverter operated by 130 Hz square wave, and an ignition circuit. An acoustic resonance phenomenon of discharge lamps could be eliminated by application of 130 Hz square wave. Also, a circuit of high voltage pulse generation for lamp ignition was added to the ballast. From the experimental results, voltage and current of the lamp operated by the electronic ballast were estimated 132.5 V and 7.6 A, respectively. and the power consumption was about 1,000 W. The weight of the ballast, which is one of important advantages, was reduced to one-fifth of conventional magnetic ballasts.

Development of Risk Based Inspection (RBI) Procedures for Optimized Preventive Maintenance (PM) Planning of Energy Plants (에너지플랜트의 최적 예방점검을 위한 위험도기반 설비 관리(RBI) 절차 개발)

  • Choi, Jeong-Woo;Yoon, Kee-Bong
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.1
    • /
    • pp.74-80
    • /
    • 2011
  • Recently, needs for extending remaining life and integrity of the aged energy plants are increased since the most domestic plants have been operated over 10 years. This need makes RAM (reliability, availability and maintainability) of the plant become more significant. RBI (risk based inspection) is main technology to increase RAM in energy plants. So far RBI has been developed mainly in the field of process plants (chemical/refinery), underground buried pipelines or nuclear power plants. However, the existing RBI procedure is limited mainly to process plants, it need to be extended to the other energy plants such as fossil power plants. In this study, a general RBI procedure for optimized PM (preventive maintenance) is proposed for various energy plants.