• Title/Summary/Keyword: 정량적 초음파 측정

Search Result 109, Processing Time 0.026 seconds

Nondestructive Evaluation of Adhesive Bonding Quality by Measurements of Peak Amplitude of Simulated Stress Wave (모의 음향 방출 신호의 Peak Amplitude측정을 통한 복합 재료 접합부의 비파괴평가)

  • Son, Y.H.;Lee, J.O.;Lee, S.H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.15 no.2
    • /
    • pp.357-363
    • /
    • 1995
  • Disbond size of adhesively bonded single lap and double lap joints CFRP composite specimens has been evaluated using acousto-ultrasonic(AU) technique. Frequency spectra for all specimens were obtained by measuring peak amplitude of the stress wave propagated through the bond-lines. By analyzing these frequency spectra, peak amplitude was found to be proportional to fractional bonding area and to be maxima at the fundamental and the third order higher harmonic frequencies of specimen thickness mode. The disbond size can be evaluated quantitatively and this technique can be applied to real structures if the reference specimens are prepared in advancve.

  • PDF

Development of quantification software for assessing thyroid nodule in ultrasound images and its clinical application in benign nodules (갑상선 초음파 의료영상을 이용한 정량분석 소프트웨어 개발과 양성 결절 환자에서의 임상 적용)

  • Ryu, Young Jae;Hur, Young Hoe;Kwon, Seong Young;Chae, Il-Seok;Kim, Min Jung;Kim, Tae-Hoon
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2021.11a
    • /
    • pp.443-445
    • /
    • 2021
  • 갑상선 결절(thyroid nodule)은 검진 인구에서 빈번하게 진단되는 질환이지만 현재까지 진단방법은 경험적이며 정성적 판단에 의존하고 있는 실정이다. 본 연구는 갑상선 결절을 평가하기 위하여 시행한 초음파 의료영상을 이용하여 정량 분석할 수 있는 소프트웨어를 개발하였으며 갑상선 양성 결절환자에서의 임상활용 가능성을 평가하고자 한다. 임상 연구는 총 13명의 갑상선 양성 결절 환자를 대상으로 하였다. 환자별 갑상선 초음파영상을 이용하여 정상부위와 병변부위에서 정량 지표인 변동계수를 각각 측정하였다. 환자별 정상부위와 병변부위의 변동계수 차이는 대응표본 T 검정을 사용하여 비교하였으며 유의한 차이를 확인할 수 있었다. 본 연구를 통하여 개발한 정량분석 소프트웨어를 실제 갑상선 양성 결절 환자에서 갑상선 결절을 분석·평가하는데 활용할 수 있을 것으로 판단된다.

Establishment of Ultrasonic Measurement and Correlations of Direct-Indirect Method for Weathering Evaluation of Stone Cultural Heritage (석조문화재 풍화도 평가를 위한 초음파 측정의 설정과 직접-간접전달방법의 상관관계)

  • Lee, Chan-Hee;Jo, Young-Hoon;Chun, Yu-Gun
    • Journal of Conservation Science
    • /
    • v.25 no.3
    • /
    • pp.233-244
    • /
    • 2009
  • This study was focused on the transducer and suitable contact material for stone cultural heritage, and the correlation of direct-indirect method in rock types for scientific development and quantitative evaluation technique of the ultrasonic measurements. As a result, it was identified the transducer (UTREXTX(RX)54kHz) and contact material (rubber clay) of the type 3 were appropriate for the ultrasonic measurements of stone cultural heritage. The direct-indirect correction factors of type 3 were calculated 1.50 for granite, 1.38 for gabbro, 1.58 for quartz diorite, respectively. This result is the first study for improvement in reliability for the ultrasonic measurements, and it will contribute to establishment of the ultrasonic survey method for stone cultural heritage. Also, complementary studies considering the surface irregularity of rocks and various contact materials will carry out, and the database about correlation of direct-indirect in rock types will establish.

  • PDF

Comparison of Shear Wave Elastography and Pathologic Results Using BI - RADS Category for Breast Mass (유방종괴에 대한 BI-RADS범주를 이용한 횡탄성 초음파와 병리결과 비교분석)

  • An, Hyun;Im, In-Chul
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.2
    • /
    • pp.217-223
    • /
    • 2018
  • This study to search the diagnostic performance of shear wave elastography(SWE) in breast mass and to compare the biopsy result and stiffness obtained from shear wave elastography. Diagnostic breast ultrasonography and SWE were targeted for 157 patients who had breast ultrasonography was diagnosed mass from June 2017 to September 2017. Pathology results of 157 patients showed a benign 92 patients(Age, $44.54{\pm}11.84$) and a malignancy 65 patients(Age, $51.55{\pm}10.54$). Final evaluation, biopsy result, and quantitative SWE result were obtained and compared with each other according to Breast Imaging Reporting and Data System(BI-RADS) of diagnostic breast ultrasonography. Quantitative SWE value and pathologic result showed the highest diagnostic specificity of 83.70% in Emean and sensitivity of 89.23% in Emin. Quantitative SWE result and biopsy result is statistically significant.(p=0.000). The optimal cut-off value for malignant lesions was 66.3 kPa and 63.7 kPa, respectively, for the sensitivity, specificity, high maximum mean elasticity value(Emax) and mean elasticity value(Emean) and this showed the highest diagnostic area under the ROC curve(Az) value compared to other SWE measurement(p=0.000). The addition of SWE to conventional US in breast mass make a increase diagnostic specificity and reduce unnecessary biopsy. Therefore, it is expected that it will be helpful to analyze the breast mass using the above analysis and apparatus.

Positional Uncertainty Reduction of Overlapped Ultrasonic Sensor Ring for Efficient Mobile Robot Obstacle Detection (효율적인 이동로봇의 장애물 탐지를 위한 중첩 초음파 센서 링의 위치 불확실성 감소)

  • Kim, Sung-Bok;Lee, Sang-Hyup
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.10 no.3
    • /
    • pp.198-206
    • /
    • 2009
  • This paper presents the reduction of the positional uncertainty of an ultrasonic sensor ring with overlapped beam pattern for the efficient obstacle detection of a mobile robot. Basically, it is assumed that a relatively small number of inexpensive low directivity ultrasonic sensors are installed at regular spacings along the side of a circular mobile robot with their beams overlapped. First, for both single and double obstacles, we show that the positional uncertainty inherent to an ultrasonic sensor can be reduced using the overlapped beam pattern, and also quantify the relative improvement in positional uncertainty. Second, given measured distance data from one or two ultrasonic sensors, we devise the geometric method to determine the position of an obstacle with respect to the center of a mobile robot. Third, we examine and compare existing ultrasonic sensor models, including Gaussian distribution, parabolic distribution, uniform distribution, and impulse, and then build the sensor model of overlapped ultrasonic sensors, adequate for obstacle detection in terms of positional uncertainty and computational requirement. Finally, through experiments using our prototype ultrasonic sensor ring, the validity of overlapped beam pattern for reduced positional uncertainty and efficient obstacle detection is demonstrated.

  • PDF

Determination of Phase Velocity Dispersion Curve and Group Velocity of lamb Waves Using Backward Radiation (후방복사를 이용한 램파의 위상속도 분산과 군속도의 측정)

  • 송성진;권성덕;정용무;김영환
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.1
    • /
    • pp.61-68
    • /
    • 2003
  • The guided wave has been widely employed to characterize thin plates and layered media. The dispersion curves of phase and group velocities are essential for the quantitative application of guided waves. In the present work, a fully automated system for the measurement of backward radiation of LLW has been developed. The specimen moves in two dimensional plane as well as in angular rotation. The signals of backward radiation of LLW were measured from an elastic plate in which specific modes of Lamb wave were strongly generated. Phase velocity of the corresponding modes was determined from the incident angle. The generated Lamb waves propagated forward and backward with the leakage of energy into water. Backward radiated LLW was detected by the same transducer and its frequency components were analyzed to extract the related information to the dispersion curves. The dispersion curves of phase velocity were measured by varying the incident angle. Moving the specimen in the linear direction of LLW propagation, group velocity was determined by measuring the transit time shift in the ultrasonic waveform.

The Comparative Study on Bone Mineral Density Accessed by Quantitative Computed Tomography and Quantitative Ultrasound (정량적 전산화단층촬영법(QCT)과 정량적 초음파법(QUS)에 의한 골밀도측정 비교)

  • Kim, Gi-Bum;Ahn, Sung-Min;Lee, Gui-Won;Kim, Sung-Chul
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.8
    • /
    • pp.198-203
    • /
    • 2011
  • The BMD difference depending on QCT and QUS, whose usages are recently being increased for the test of BMD, was accessed for 106 subjects of a general health examination who were aged between 24~69 year-old and results were derived as follows. The measured value of BMD by QCT and QUS showed significant correlation in general (p>0.05). In terms of the difference generated between the measurement methods depending on sexes, the female subjects showed significantly low T-score in the test made through QUS (p<0.05). Depending on ages, there was T-score difference among the subjects aged more than 40 year-old within significant range (p<0.05). When it came to the effect depending on heights and on weights, no group showed significant difference and in a group with less than 22.9 of BMI value, the T-score was measured significantly low when testing it through QCT while other groups were not affected by any testing methods. Likewise, it may require a different measurement method when it comes to the measurement of bone mineral density depending on sex, age, height, and BMI among patients. Thus, it suggests obtaining accurate data by conducting various testing methods in case of a special occasion.

Display-Pixel-Based Focusing Method for Ultrasound Imaging (의료 초음파 영상을 위한 화소단위 집속기법)

  • 황재섭;송태경
    • Journal of Biomedical Engineering Research
    • /
    • v.21 no.4
    • /
    • pp.419-431
    • /
    • 2000
  • In this paper, a new beamforming technique is proposed, which can completely eliminate all the artifacts caused by digital scan converter. In the proposed method, named display-pixel-based focusing(DPBF) by the authors, ultrasound waves are focused directly at the display pixels instead of sampling points on the polar coordinate. Consequently. the DPBF system does not require the digital scan converter. To verify the proposed method, we modified a commercial scanner and performed experiments with a 3.5 MHz convex array and a 7.5 MHz linear array. We also defined and measured ICRA/B(Image Coarseness Ratio) to compare the image quality quantitatively. The experimental results with in vivo and in vitro data show that the proposed method improves the ICRA/B considerably, resulting in much smoother and finer images.

  • PDF

Evaluation of Image Quality using ATS-539 Phantom and SNR in the Ultrasonographic Equipment (ATS-539 다목적 팬텀과 SNR을 이용한 초음파 영상평가)

  • Kim, Min-Ju;Lee, Jin-Soo;Ko, Seong-Jin;Kang, Se-Sik;Kim, Jung-Hoon;Kim, Dong-Hyun;Kim, Changsoo
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.8
    • /
    • pp.284-291
    • /
    • 2013
  • The importance of ultrasound examination in the field of medical imaging has been emphasized and the interest in sonographic image evaluation is growing. However image evaluations by the non-standardized criteria and methods, so establishment of legal provisions and objective evaluation criteria are needed. In this study, we used SNR to find out more quantitative way and supplement the limitations of the existing phantom image evaluation. The results of acquired 8 images using ATS-539 multipurpose phantom were compared in SNR of sensitivity and gray-scale dynamic range. In the result of the experiment, excellent equipment of existing phantom images are G1, S1 and G2 in regular sequence. In SNR of sensitivity, G1, S1 and G2 and in SNR of gray-scale dynamic range, S1 G1 and G2 in order. In the conclusion, all the experiment results did not show big difference and regular pattern neither. Therefore, the new evaluation measures should be used with the existing phantom image evaluation method for more objective and quantitative evaluation of the ultrasound imaging device.

Multi-layered Gap Measurement on In-Vessel Cerium Retention Using Ultrasonic Wave Reflective Pattern Analysis and Frequency Diversity Signal Processing (초음파 반사 패턴과 주파수 대역 분할 신호처리를 이용한 다층구조인 노내 간극 측정)

  • Koo, Kil-Mo;Sim, Cheul-Mu;Kim, Jong-Hwan;Kim, Sang-Baik;Kim, Hee-Dong;Park, Chi-Seung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.4
    • /
    • pp.314-321
    • /
    • 2000
  • A gap between a $Al_2O_3/Fe$ thermite and lower head vessel is formed in the lower-plenum arrested vessel attack(LAVA) experiment which is the 1st phase study of simulation of naturally arrested vessel attack in vessel(SONATA-IV). The gap measurement using a conventional ultrasonic method would be lack of a reliability due to the structure complexity and the metallurgical grain size change of the lower head HAZ occurred by a thermite $Al_2O_3/Fe$ melt or a $Al_2O_3$ melt at $2300^{\circ}C$. The grain echoes having false signals and lower S/N ratio signals are detected due to a multiple scattering, a mode conversion and an attenuation of a ultrasonic resulted from at the interface of increased grain size zone. In this test, the signals pattern was classified to understand the behavior of the ultrasonic in a multi-layer specimen of solid-liquid-solid of assuming that the thermite and the lower head vessel is immersed. The polarity threshold algorithm of frequency diversity gives us the enhancement about 6dB of the ratio S/N.

  • PDF