• Title/Summary/Keyword: 접합 보강재

Search Result 98, Processing Time 0.019 seconds

Evaluating Seismic Performance of Steel Welded Moment Connections Fabricated with SN Steel (SN 강재가 사용된 강구조 용접모멘트접합부의 내진성능 평가)

  • Oh, Sang-Hoon;Choi, Young-Jae;Yoon, Sung-Kee;Lee, Dong-Gue
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.3
    • /
    • pp.271-280
    • /
    • 2010
  • This study was programmed to fabricate a beam-to-column connection that is limited to a steel-welded moment connection with full-scale members, using SN steel. A cyclic seismic test was conducted of the nine specimens that were fabricated by choosing the test variable for the weld access hole geometry, connection design method, and RBS. From the test results, failure modes, the moment-drift behavior, and the strain distribution were provided. From the specimen material properties, the beam's nominal plastic flexural capacity and classified qualified connection as a special moment flame were calculated. By analyzing the skeleton part and the baushinger part, a range of strength-raising effects, and deformation ratios were provided, with which the seismic performance of the specimens were evaluated. The test results showed that the specimens eliminated their weld access holes that demonstrated higher seismic performance than the specimens' existing weld access holes, and that the WUF-W connection that was reinforced by the supplemental fillet weld around the shear tap that was fastened by five bolts demonstrated superior seismic performance.

Structural Behavior Evaluation of NRC Beam-Column Connections (NRC 보-기둥 접합부의 구조적 거동 평가)

  • Jeon, Ji-Hwan;Lee, Sang-Yun;Kim, Seung-Hun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.1
    • /
    • pp.73-80
    • /
    • 2022
  • In this study, details of NRC beam-column connections were developed in which beam and columns pre-assembled in factories using steel angles were bolted on site. The developed joint details are NRC-J type and NRC-JD type. NRC-J type is a method of tensile joining with TS bolts to the side and lower surfaces of the side plate of the NRC column and the end plate of the NRC beam. NRC-JD type has a rigid joint with high-strength bolts between the NRC beam and the side of the NRC column for shear, and with lap splices of reinforcing bar penetrating the joint and the beam main reinforcement for bending. For the seismic performance evaluation of the joint, three specimens were tested: an NRC-J specimen and NRC-JD specimen with NRC beam-column joint details, and an RC-J specimen with RC beam-column joint detail. As a result of the repeated lateral load test, the final failure mode of all specimens was the bending fracture of the beam at the beam-column interface. Compared to the RC-J specimen, the maximum strength of the specimen by the positive force was 10.1% and 29.6% higher in the NRC-J specimen and the NRC-JD specimen, respectively. Both NRC joint details were evaluated to secure ductility of 0.03 rad or more, the minimum total inter-story displacement angle required for the composite intermediate moment frame according to the KDS standard (KDS 41 31 00). At the slope by relative storey displacemet of 5.7%, the NRC-J specimen and the NRC-JD specimen had about 34.8% and 61.1% greater cumulative energy dissipation capacity than the RC specimen. The experimental strength of the NRC beam-column connection was evaluated to be 30% to 53% greater than the theoretical strength according to the KDS standard formula, and the standard formula evaluated the joint performance as a safety side.

Tensile Behavior of CFT Column-to-H beam Connections with External T-shaped Stiffeners (T-스티프너 보강 콘크리트충전 각형강관 기둥-H형강 보 접합부의 인장거동)

  • Kang, Chang Hoon;Shin, Kyung Jae;Oh, Young Suk;Moon, Tae Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.1
    • /
    • pp.121-130
    • /
    • 2002
  • This paper presents the tensile behavior of a Concrete-Filled Square Steel Tubular (CFT) column to H-beam welded connections. These connections were externally reinforced with T-shaped stiffeners at the junction of CFT column and beam. The tensile loading tests of eighteen tee-joint connections and finite element analysis using ANSYS were carried out. The main parameters of tests are as follows: 1) the thickness of Square Steel Tubular Column : 6 mm, 9 mm, 2) the strength ratios of tensile strength of horizontal stiffeners to tensile strength of beam flange : 70 %, 100 %, 150 %, 3) the strength ratios of shear strength of vertical stiffeners to tensile strength of beam flange : 80 %, 115 %, 160 %. The results of the tests demonstrate that overall behavior and failure modes of all the specimens are governed mainly by the horizontal stiffeners rather than the vertical stiffeners, and the vertical stiffener played only a role in transferring load introduced from beam to column.

Initial Stiffness of Beam Column Joints of PCS Structural Systems (PCS 구조 시스템 접합부의 초기 강성에 대한 연구)

  • Park, Soon-Kyu;Kim, Moo-Kyung
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.3
    • /
    • pp.271-282
    • /
    • 2008
  • Specific joint devices composed of end-plates and through bolts are under development to assemble steel beams to PC columns efficiently by dry construction method for the PCS structural system, of which major structural components are precast concrete columns and steel beams. Seismic performance of the joint devices had been evaluated by experimental tests in the previous studies and it was showed that all the performance requirements regarding to strength deterioration, stiffness degradation and energy dissipation capacity were satisfied to the criteria of ACI requirements, but the initial stiffness was not. In order to find out possible causes of the insufficient rigidity of the joint devices and provide the proper measures to improve the performance of the joint accordingly, numerical analyses were carried out by using ABAQUS. Parameters, such as thickness of neoprene pad, conditions of surface between PC column and end-plate, magnitude of pretension forces of through bolts, stiffness of end-plate were taken into consideration. As the result, it was found that the rigidity of the PCS system was negatively affected by the magnitude of initial gaps between PC columns and end-plates, and insufficient stiffness of neoprene fillers and end plates. In order to improve the initial stiffness performance of the joints, measures such as increase of the magnitude of pretension forces on through bolts and increase of the stiffness of end-plate by reducing the bolt pitch and providing adequate stiffeners are recommended.

A Study on the Stiffness of CBA(Corner Block with Anchor Bolt) Joint in Knockdown Type Table Furniture (조립식(組立式) 탁자(卓子)의 CBA접합부(接合部) 강성(剛性)에 관(關)한 연구(硏究))

  • Chung, Woo-Yang;Lee, Phil-Woo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.17 no.2
    • /
    • pp.34-64
    • /
    • 1989
  • Corner block with anchor bolt(CBA) joint method used in knock-down type table furniture manufacturing can reduce the packing and transporting cost. Unfortunately. it also has the disastrous defect to be loosend and unstable during the service life mainly due to fatigue and creep(repeated and prolonged loading). So 22 joint groups constructed were tested to evaluate the effect of some design factors related to the size of side rail(apron). block attachment to side rail. and the number of anchor bolt as well as the effect of the type of corner block(mitered type vs. rectangular type) Usable strength from the stiffness coefficients of each joint group were analysed with SPSS /PC+ and described as the criteria of CBA joint construction. The conclusions were as follows: The height of side rail(50, 75 and 100 mm) and the addition of polyvinyl acetate(PVAc) emulsion in the corner block attactment to side rail had the effect on raising the usable strength of CBA joint with remarkable high significance. And the effect of 2 - anchor bolts was also superior to that of 1 - bolt significantly. However. the thickness of side rail(22 mm vs. 25 mm) had no effect on the strengthening the table joint rigidity. Mitered type corner block joint appeared to he recommendable for CBA jointed table construction rather than the rectangular type one regardless of the method of block attachment to side rail. The best result identified from Duncan's multiple comparison was in the construction with 25 mm thick and 100 mm height of side rail fastened using 2 - anchor bolts in mitered type corner block. But it would be reasonable to use 22 mm thick & 75 mm high side rail and mitered corner block with PVAc emulsion & 2 bolts considering the productivity and production cost down in the MDF furniture manufacturing industries.

  • PDF

Restoration of the Chimi Excavated from the Busosan Temple Site in Buyeo and Study of Its Production Techniques (부여 부소산사지 출토 치미의 재 복원을 통한 제작기법)

  • Hwang, Hyunsung;Na, Ahyoung
    • Conservation Science in Museum
    • /
    • v.27
    • /
    • pp.1-22
    • /
    • 2022
  • A chimi(a roof ridge decoration) excavated from the Busosan Temple Site in Buyeo was restored in 1978 at the Buyeo Museum. The gypsum restoration material had deteriorated over time and part of it was seriously damaged and unable to bear the weight of the chimi. The chimi features traces of emergency treatment revealing that the inside of the body and some portions of the tail were reinforced several times using epoxy resin. A condition survey performed in preparation for its transfer for an exhibition found the lower body and wings of the chimi to be highly vulnerable and it was determined that the chimi needed further restoration. The dismantling of the chimi for restoration revealed several elements that provide clues to the production techniques applied by its makers, so they were subjected to inspection. This study explores the production techniques used in the chimi from the Busosan Temple Site that were revealed during the process of dismantling it for restoration. The chimi was inspected using 3D scanning and its rigid vertical shape was restored to a natural form based on the production techniques identified during the dismantling process. The existing restoration material was replaced to improve durability. 3D printed elements were produced based on 3D modelling and were joined to the original chimi to correct its shape and fill in the missing parts, restoring the chimi to its original appearance.

Conservation Treatment of the Rickshaw in the Daegu Modern History Museum Collection (대구근대역사관 소장 인력거 보존처리)

  • Seo Yeonju;Lee Uicheon;Park Junghae;Lee Yeongju;Kim Soochul
    • Conservation Science in Museum
    • /
    • v.29
    • /
    • pp.33-46
    • /
    • 2023
  • Modern and contemporary cultural assets are defined as a collective term for tangible historical and cultural assets produced in the modern and contemporary period (around the opening of Joseon to the present) in Korea. Among them, rickshaws have been used as a major means of transportation for about 40 years since the opening of the ports in Joseon. The repair process for rickshaws divides the rickshaw into three parts, namely the body, the cover, and the wheels, applying a plaster treatment process by referring to the outcomes of the condition assessment and material analysis for the metal, wood, fiber, and paint used. Overall, the repair process is carried out through dry/wet cleaning, joining, stabilization, reinforcement of damaged parts, and other restoration treatments, which reveal metal decorations and patterns on the scaffolding (flowers, arabesque patterns, etc.) that were previously not observable with the naked eye, while also adding to the stability of the artifact. In addition, props were produced to ensure the artifact's safe exhibition.

Scientific Conservation Treatment of the Celadon Jar with the Inscription of 'the Fourth Sunhwa Year'(National Treasure No.326) (국보 제326호 청자 '순화4년'명 항아리의 과학적 보존처리)

  • Lee, Sun Myung;Kwon, Oh Young;Park, Jongseo;Han, Woo Rim
    • Journal of Conservation Science
    • /
    • v.35 no.5
    • /
    • pp.453-469
    • /
    • 2019
  • The celadon jar with inscription of 'the Fourth Sunhwa Year' is an important chronology that shows the conditions of production of the early celadon due to the inscription on the bottom including its purpose, application, and the producer. This celadon jar has been restored several times in the past. However, concerns over the structural stability, such as the separation and level differences in the joined cracks, have risen because of the aging of the repair materials, which were subjected to various environmental changes over a long time. By examining the conditions of preservation, the major damage was identified as the '入' shaped crack on the front, the 'V' shaped restored part and the crack on its left side, and the 'J' shaped crack on the back side. In the past, the cracks were found to be joined using a refined lacquer containing camphor, drying oil, rosin, etc. mixed with soil powder. The joint line was repainted with the refined lacquer and covered with gold powder. The missing parts were restored with gypsum and colored with acrylic color. After that, the repair materials were aged and emergency treatment was performed at the National Museum of Korea in 1981. At that time, Cemedine C or Cemedine C mixed with microballoons was used for reinforcing the cracks. Conservation treatment focused on removing the past repair materials and reinforcing the physically fragile parts by joining and restoring them based on the examination of the preservation condition. in addition, the area around the restored part was colored for future exhibition.

A Study on Method for The Reduction of Decreasing Strength of Concrete When Welding the Connection Part of Composite Structure Consist of Steel and Concrete (강과 콘크리트의 합성 부재 용접시 콘크리트 강도 저감 방지 기법 연구)

  • Won, Deok-Hee;Han, Taek-Hee;Lee, Dong-Jun;Kang, Young-Jong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.4 s.56
    • /
    • pp.116-125
    • /
    • 2009
  • Recently, modular system are popular in construction fields, and they are increasing their marcket share. To compare modular units, bolting and welding are most popular methods. However, the temperature around a welded part might be over than 1,300$^{\circ}C and the composite member might be exposed tp the direct welding heat about 20,000$^{\circ}C. This high welding heat makes decrease of the concrete strength. If the concrete strength seriously decreases, it can affect the behavior and safty of a structure. On this study, To prevent of concrete strength decreases by welding heat, we suggested method of to insert between steel and concrete.

An Experimental Study on the Seismic Performance of Reinforced Concrete Exterior Beam-Column Joint with Steel Fiber Volume Fractions (강섬유 혼입률에 따른 철근콘크리트 외부 보-기둥 접합부의 내진성능에 대한 실험적 연구)

  • Lee, Jang-Jae;Bae, Baek-Il;Choi, Chang-Sik
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.4
    • /
    • pp.15-23
    • /
    • 2018
  • The purpose of this study is to evaluate the anchorage capacity of longitudinal bars for reinforced concrete exterior beam - column joints with steel fiber volume fractions. For this purpose, the steel fiber volume fraction was set to 0, 1, 2%, and the performance was compared with that of each other specimens. According to the test results, the maximum strength of EX-HK-NJR-0 decreased by 13% compared with the control specimen and EX-HK-NJR-1 decreased by 3% compared to the control specimen. However, when 2% of steel fiber was mixed, the maximum strength increased about 56% compared to the control specimen. The energy dissipation capacity of EX-HK-NJR-0 (when no transverse steel bars are placed) decreased by 61% compared to the control specimen. In addition, the energy dissipation capacity of the specimens with a steel fiber content of 1% decreased by 5% and 2% increased by 94% compared to control specimen. EX-HK-NJR-1,2 and the control specimen EX-HK-JR-0 experienced yielding of the reinforcing bars at the column interface before maximum strength development. However, when the EX-HK-NJR-0, the reinforcing bars at the column interface experienced yielding after maximum strength development. Therefore, reinforcement of steel fiber is considered to reduce the required development length for yielding of steel bars.