• Title/Summary/Keyword: 접촉 이론

Search Result 328, Processing Time 0.168 seconds

A Study on the LCC Type High Frequency DC/DC Converter for Contactless Power Supply System (비접촉 전원장치에 적용한 LCC형 고주파 공진 DC/DC 컨버터에 관한 연구)

  • Kim, Dong-Hee;Hwang, Gye-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.6
    • /
    • pp.55-64
    • /
    • 2007
  • This paper represents characteristics and design example of series loaded LCC type high frequency resonant DC-DC converter with variable parallel capacitor in the secondary side of inductive power transformer. In this converter, ZVS(zero voltage switching) technique is applied to reduce turn-off switching losses, and the applied converter used the PFM switching pattern to control output voltage. The operating characteristics of the proposed converter is analyzed using nomalized parameter such as switching frequency and load factor with varing the secondary parallel resonant capacitor. The results of analysis show the operating characteristics and design method of the proposed converter using characteristic values. And the proposed converter can be applied for the contactless power supply with linear transfer system such as dean room facilities of semiconductor and Flat Panel Display.

Analysis of the Axisymmetric Hydro-Mechanical Deep Drawing Process by Using the Finite Element Method (유한 요소법을 이용한 축대칭 하이드로 미케니칼 디프 드로잉 공정의 해석)

  • 양동열;김한경;이항수;김경웅
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.5
    • /
    • pp.873-882
    • /
    • 1992
  • The study is concerned with the rigid-plastic element analysis for axisymmetric hydromechanical deep drawing in which the fluid flow influences the metal deformation. Due to the fluid pressure acting on the sheet material hydromechanical deep drawing is distinguished from the conventional deep drawing processes. In considering the pressure effect, the governing equation for fluid pressure is solved and the result is reflected on the global stiffness matrix. The solution procedure consists of two stages ; i.e., initial bulging of the sheet surface before the initiation of steady fluid flow in the flange and fluid-lubricated stage. The problem is decoupled between fluid analysis and analysis of solid deformation by deformation by iterative feedback of mutual computed results. The corresponding experiments are carried out for axisymmetric hydro-mechanical deep drawing of annealled aluminium sheet as well as for deep drawing. It has been shown from the experiments that the limit drawing ratio for hydro-mechanical deep drawing is improved as compared with deep drawing. The computed results are in good agreement with the experiment for variation of punch head and chamber pressure with respect to the punch travel and for distribution of thicknees strain. It is thus shown that the present method of analysis can be effectively applied to the analysis of axisymmetric hydro-mechanical deep drawing processes.

Study on the Rolling Noise Model Using an Analysis of Wheel and Rail Vibration Characteristics (철도 차륜 및 레일 진동 특성 해석을 통한 전동 소음 모델 연구)

  • Jang, Seungho;Ryue, Jungsoo
    • Journal of the Korean Society for Railway
    • /
    • v.16 no.3
    • /
    • pp.175-182
    • /
    • 2013
  • Rolling noise is an important source of noise from railways; it is caused by wheel and rail vibrations induced by acoustic roughness at the wheel/rail contact. To reduce rolling noise, it is necessary to have a reliable prediction model that can be used to investigate the effects of various parameters related to the rolling noise. This paper deals with modeling rolling noise from wheel and rail vibrations. In this study, the track is modeled as a discretely supported beam by regarding concrete slab tracks, and the wheel vibration is simulated by using the finite element method. The vertical and lateral wheel/rail contact forces are modeled using the linearized Hertzian contact theory, and then the vibration responses of the wheel and rail are calculated to predict the radiated noise. To validate the proposed model, a field measurement was carried out for a test vehicle. It was found that the predicted result agrees well with the measured one, showing similar behavior in the frequency range between 200 and 4000 Hz where the rolling noise is prominent.

Thermal Performance and Impact Resistance Evaluations of Composite Insulation Mat Reinforced Polyurethane Foam (복합 단열 매트 보강 폴리우레탄 폼의 열적 성능 및 내충격성 평가)

  • Hwang, Byeong-Kwan;Bae, Jin-Ho;Lee, Jae-Myung
    • Composites Research
    • /
    • v.32 no.5
    • /
    • pp.290-295
    • /
    • 2019
  • In the present study, composite insulation mat was reinforced over polyurethane foam (PUF) to improve the thermal performance and impact resistance of the PUF applied to the liquefied natural gas carrier insulation system. The composite insulation mat used Kevlar, aerogel, and cryogel composite mat that can be applied in a cryogenic environment. The thermal conductivity was measured at $20^{\circ}C$ to investigate the thermal performance, and the drop impact test was carried out under impact energy of 30 J at $20^{\circ}C$, $-163^{\circ}C$ to investigate the impact resistance. The measured thermal performance was compared with neat PUF through effective thermal conductivity theoretical value. The shock resistance was evaluated of contact force, contact time, and absorb energy. In experimental results, cryogel composite mat was the best performance in terms of thermal performance, and aerogel composite mat was the best performance in terms of impact resistance.

Transactive Memory System of a Virtual Team : Theoretical Exploration and Empirical Examination (가상 팀의 교류활성기억 시스템과 팀 성과의 관계 : 가상 팀 속성을 선행요인으로)

  • Shin, Kyung-Shik;Suh, A-Young
    • The Journal of Society for e-Business Studies
    • /
    • v.15 no.2
    • /
    • pp.137-166
    • /
    • 2010
  • A virtual team is defined a group of people that use electronic communications for some or all of their interactions with other team members. Because team members of a virtual team are physically and temporally distributed, a team's transactive memory system(TMS) is considered to be crucial for the team's effectiveness and performance. TMS refers to a set of individual memory systems which integrate knowledge possessed by particular members through a shared awareness of who knows what. This paper seeks to understand (1) how a virtual team's TMS influences team performance, and (2) what factors contribute to developing the team's TMS. Given these purposes, through the extensive literature review, we first identified components and antecedents to develop a theoretical model that predicts a virtual team's performance. Using the survey data gathered from 172 virtual teams, this study found that expertise location, coordination, and cognition-based trust which were proposed as three components of TMS positively influenced a virtual team's performance. Furthermore, this study uncovered that perceived media richness, network tie strength, and shared norms significantly influenced the components of TMS, while geographical dispersion did not exert any significant influence on TMS.

The Effect of Human Brand Characteristics of Customer Service Employees on Brand Attitude (서비스 접점직원의 휴먼브랜드적 특성이 브랜드 태도에 미치는 영향)

  • Park, So-Young;Kim, Yong-Ho
    • Management & Information Systems Review
    • /
    • v.36 no.4
    • /
    • pp.187-209
    • /
    • 2017
  • Service industry performance and competitive advantage depend on the attitudes and behavior of customer service employees who produce and deliver services through contact with customers. Most studies on customer service employees so far have concentrated on kindness, attitudes, or benefits. This study focuses on the increasing importance of customer service employees and intends to study them from the viewpoint of human brands that recognize customer service employees as a brand. In addition to the role of the employee at the service contact point, the customer participation behavior affects the interaction process with the customer service employee. Ultimately, customers could no longer be excluded from control to improve service quality. This study based on theory that the human brand characteristics of the customer service employees lead the customer's participation, which has a positive effect on the relationship with the service brand and the service brand attitude surveyed and analyzed customers who use service brand. This study is summarized as follows. First, the relationship between the service brand and the customer is examined. Second, this study also expands prior studies by examining the human brand characteristics of customer service employees and customers' willingness to participate in providing information on the impact of the consumer-brand relationship. The results of the study indicate that among the customer service employees' human brand characteristics reliability, familiarity, and empathy were found to affect the relationship between customers, the service brand, and the attitude toward the service brand the most. This study provides important implications for theoretical and practical strategies by examining the qualities and characteristics of customer service employees, which are the most important agents of marketing.

  • PDF

Theoretical and experimental studies on influence of electrode variations in electrical resistivity survey for tunnel ahead prediction (터널 굴착면 전방조사를 위한 전기비저항 탐사에서 전극의 변화가 미치는 영향에 대한 이론 및 실험연구)

  • Hong, Chang-Ho;Chong, Song-Hun;Hong, Eun-Soo;Cho, Gye-Chun;Kwon, Tae-Hyuk
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.2
    • /
    • pp.267-278
    • /
    • 2019
  • Variety of tunnel ahead prediction methods have been performed for safe tunnel construction during tunnel excavation. Pole-pole array among the electrical resistivity survey, which is one of the tunnel ahead prediction method, has been utilized to predict water-bearing sediments or weak zone located within 5 times of tunnel diameter. One of the most important processes is the estimation of virgin ground resistivity and it can be obtained from the following process: 1) calculation of contact area between the electrodes and the medium, and 2) assumption of the electrodes as equivalent spherical electrodes which have a same surface area with the electrodes. This assumption is valid in a small contact area and sufficient distance between the electrodes. Since the measured resistance, in general, varies with the electrode size, shape, and distance between the electrodes, it is necessary to evaluate the influence of these factors. In this study, theoretical equations were derived and experimental tests were conducted considering the electrode size, shape, and distance of cylindrical electrodes which is the most commonly utilized electrode shape. Through this theoretical and experimental study, it is known that one should be careful to use the assumption of the equivalent half-spherical electrode with large ratio between the penetrated depth and radius of the cylindrical electrode, as the error may get larger.

Internal Flow and Evaporation Characteristic inside a Water Droplet on a Vertical Vibrating Hydrophobic Surface (수직 진동하는 소수성 표면 위 액적의 내부유동 및 증발특성 연구)

  • Kim, Hun;Lim, Hee-Chang
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.7
    • /
    • pp.579-589
    • /
    • 2015
  • This study aims to understand the internal flow and the evaporation characteristics of a deionized water droplet subjected to vertical forced vibrations. To predict and evaluate its resonance frequency, the theories of Lamb, Strani, and Sabetta have been applied. To visualize the precise mode, shape, and internal flow inside a droplet, the experiment utilizes a combination of a high-speed camera, macro lens, and continuous laser. As a result, a water droplet on a hydrophobic surface has its typical shape at each mode, and complicated vortices are observed inside the droplet. In particular, large symmetrical flow streams are generated along the vertical axis at each mode, with a large circulating movement from the bottom to the top and then to the triple contact line along the droplet surface. In addition, a bifurcation-shaped flow pattern is formed at modes 2 and 4, whereas a large ellipsoid-shape flow pattern forms at modes 6 and 8. Mode 4 has the fastest internal flow speed and evaporation rate, followed by modes 8 then 6, with 2 having the slowest of these properties. Each mode has the fastest evaporation rate amongst its neighboring frequencies. Finally, the droplet evaporation under vertical vibration would lead to more rapid evaporation, particularly for mode 4.

A Study on Low Power Energy Transfer Circuits of the Non Contact Method by means of Solar Generation (태양광 발전에 의한 비접촉 방식 저 전력 에너지 전송회로에 관한 연구)

  • Hwang, Lark-Hoon;Na, Seung-Kwon;Kim, Jong-Rae;Choi, Gi-Ho;Kim, Jin-Seon
    • Journal of Advanced Navigation Technology
    • /
    • v.18 no.1
    • /
    • pp.35-43
    • /
    • 2014
  • In this paper, it is about to non-contact wireless power transmission according to various conditions of self induction principle between the two planar coils at a transmission unit and a receiving unit based on the theory of wireless power transmission. The experiments are occurred in order to power transfer of noncontact method from designed wireless circuits in the primely coil and secondary coil, and the applying to Half Bridge Resonant converter transmission unit and receiving unit. and that were able to prepared circumstance to calculate of the output voltage and power source. The main power of the inductive coupling the resonant converter at the transmission unit is converted electrical energy using the solar cell module and artificial light source (halogen lamp) as a replace light and received 24 V power supply from solar power was used a input power source for the wireless power transmission device. Experimental results, to received of power is used to illuminate the lighting and to charge the battery in receiving circuit.And the wireless power transmission efficiency measured at the output side of the transmission unit is obtained about 70% to 89% compared to input power of receiving unit.In addition, efficiency were tested through ID verification method and comparing the phase difference between the voltage when foreign substances interfere with wireless power transmission.

Changes in External Radiation Dose Rate for PET-CT Test Patients (PET-CT 검사 환자의 외부 방사선량률 변화)

  • Kim, Su-Jin;Han, Eun-Ok
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.2
    • /
    • pp.103-107
    • /
    • 2012
  • This paper analyzes changes in the external radiation dose rate of PET-CT test patients as a part of providing basic materials for reduction of radiation exposure to PET-CT test patients. In theory the measurement of external radiation dose rate of PET-CT test patients shows that the further the distance from the patient injected with radioactive pharmaceutical and a longer time elapsement from the injection leads to a smaller amount of radiation. Particularly, the amount of radiation marked the highest in the chest was at 4.17 minutes immediately after the intravenous injection and in the head after 77.47 minutes after urination in advance to the PET-CT test. As in the generalized information, it is desired to keep distance between the patient and caretakers or professionals to reduce the amount of radiation exposure from PET-CT test patients and to resume contact the patient after the time when the radiation has reduced. If contact is unavoidable, it is desired to keep at least 200cm from the patient. In addition, the amount of radiation reached the highest in the chest at first and then in the head from 77 minutes after injection. Accordingly, it would be helpful in achieving the optimization if contact is made based on the patient's physical characteristics. This study is significant as it measures changes in radiation the dose rate by; distance from the PET-CT test patient, time elapsed, and specific parts of body. Further studies based on the findings in this paper are required to analyze changes in radiation dose rate in accordance with individual characteristics unique to PET-CT patients and to utilize the results to reduce the amount of radiation patient, caretakers and professions are exposed.