• Title/Summary/Keyword: 접촉 센서

Search Result 574, Processing Time 0.038 seconds

Development of Hybrid Temperature Measurement System (복합형 체온계 개발)

  • Han, Young-Hwan;Park, Seung-Hwan
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2010.07a
    • /
    • pp.195-197
    • /
    • 2010
  • 체온은 가장 기본적인 진단 정보로써 여러 가지 생리 변화를 반영하는 지표이므로 거의 모든 질환에 대해 반드시 측정하도록 되어있다. 그러므로 체온을 정확하고 빠르게 측정하는 것은 매우 중요하다. 본 논문은 복합형 체온측정 시스템의 개발에 목적이 있다. 즉, 하나의 복합 시스템으로 고막과 이마에서의 체온을 측정하려고 한다. 개발 결과, 이 시스템은 IR 센서를 사용한 비접촉식 방식이며 빠른 응답시간과 $0.2^{\circ}C$의 정밀도를 가지고 있다. 또한 체온 측정을 위한 주변온도 보상을 고려하여 온도 측정의 정확도를 높였다.

  • PDF

Detecting Characteristics of Catalytic Combustible Gas Sensor (접촉연소식 가스 센서의 검지특성)

  • 박찬원;원창섭;유영한;안형근;한득영
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.10
    • /
    • pp.865-870
    • /
    • 2000
  • In this paper, catalytic combustible gas sensor was fabricated and tested under flammable gases such as CH$_4$and $C_4$H$_{10}$by using Pt coil as a heater and/or temperature sensing element. Fine $Al_2$O$_3$powder was used for a bead and Pt, Pd noble metal powder for a catalyst. Resistance variation of Pt wire was traced by the changes of the gas concentrations in a chamber. Output voltage was then monitored to obtain the gas concentration from the resistance variation. In this experiment, MgO was used to protect cracks in the based and TiO$_2$to increase the sensitivity of the sensors. Water glass was also added to enhance the selectivity to the combustible gases.s.

  • PDF

DGPS Application Technique Suitable for Bridge Movement Monitoring (교량거동 모니터링에 적합한 DGPS 응용기술 개발)

  • Choi, Byoung-Gil;Kim, Sung-Soo
    • Proceedings of the Korean Association of Geographic Inforamtion Studies Conference
    • /
    • 2008.06a
    • /
    • pp.411-413
    • /
    • 2008
  • 본 연구의 목적은 DGPS 기법을 이용하여 장대교량의 거동을 모니터링하는 기술을 개발하는데 있다. GPS 센서를 이용한 교량거동 모니터링 기술은 다수의 GPS 센서를 시설물 외부에 설치하여 전체적인 거동상태를 모니터링 함으로써 순간적인 세부변위는 물론 장기간의 관측을 통한 기초침하, 크리프 릴렉세이션 등의 거동까지 실시간으로 모니터링 할 수 있는 기술이다. 본 연구의 최종 성과물은 안전관리 대상 주요 시설물의 거동을 비접촉 방식으로 감시하고 그 결과를 그래픽으로 화면을 통하여 사용자에게 제공함으로써 사용자의 직관적인 이해도를 높일 수 있을 것으로 기대되며, 장대교량, 터널, 댐, 건물 등 대형시설물의 거동을 효과적으로 감시하고 그 결과를 전송할 수 있어 광범위하게 사용이 될 수 있을 것으로 판단된다.

  • PDF

A Study of the Non-Contact Bill Counter using Optical Fiber Sensor (광섬유 센서를 이용한 지폐 계수 장치에 관한 연구)

  • Kang, Dae-Hwa;Shin, Woo-Cheol;Song, Doo-Sang;Jang, Tak-Soon;Hong, June-Hee
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.16 no.6
    • /
    • pp.231-236
    • /
    • 2007
  • In this paper, we studied the possibility of non-contact bill counting method using optical fiber sensor instead of traditionally used friction counting method. To implement non-contact counting, we designed and made optical fiber sensor and related parts. optical fiber sensor is made of optical fiber of 1mm diameter, photo diode and laser diode. Based on the conclusion which derived from preliminary experiment, instrument part is designed to make unevenness on the surface of bill paper and to stay parallel with optical fiber section. By analyzing the signal of optical sensor, we made counting program. Experimental instrument is composed of sensor part, instrument part, signal handling part. We checked the possibility of non-contact counting method after implementing experiment by using optical fiber sensor and instrument part.

Fabrication method of PDMS microlensesusing water-based molding method (표면개질에 의한 물방울 접촉각 변화를 이용하여 제작된 PDMS 마이크로 렌즈)

  • Kim, Hong-Ki;Yun, Kwang-Seok
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.5
    • /
    • pp.375-379
    • /
    • 2008
  • This paper reports a new fabrication method of polydimethylsiloxane (PDMS) microlenses with various curvatures by using a water-based mold. The hydrophobic surface of Polypropylene (PP) substrate was modified by corona discharge using tesla coil to have hydrophilic surface. Then hydrophilic surface of PP substrate takes hydrophobic recovery to have various contact angles from less than $25^{\circ}$ to about $84^{\circ}$. By using the water droplets with various contact angles as replica molds for PDMS process, we could obtain PDMS microlenses with various curvatures.

Automobile Serving Robot for Untact System (비대면 시스템 구현을 위한 자율주행 서빙 로봇)

  • Hong, Jeoun-Hun;Song, Chang-Ui;Kim, Dae-Gwan;Lee, Geun-Ho
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2020.11a
    • /
    • pp.945-948
    • /
    • 2020
  • 최근 코로나 사태로 인하여 한국에서는 사람 간에 거리를 두는 사회적 거리 두기와 생활 속 거리두기를 시행하고 있다. 또 식당에서의 지출 중 가장 큰 비율을 차지하고 있다. 인건비를 절감하기 위해 본 연구는 2D Lidar 센서를 사용하여 식당에서의 사람과의 접촉이 가장 큰 서빙의 역할을 로봇이 직접 하는 것을 목표로 하였다. Lidar 센서를 이용해서 SLAM을 구현하였고 안드로이드 앱을 사용하여 주문 결제를, Four Bar Linkage를 사용하여 음식 전달 부분을 구현하였다.

Analysis of Occlusal Contacts Using Add-picture Method (Add-picture 방법을 이용한 교합접촉점 분석)

  • Park, Ko-Woon;Cho, Lee-Ra;Kim, Dae-Gon;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.1
    • /
    • pp.45-58
    • /
    • 2013
  • The purpose of this study was to analyze the area of occlusal contact points using visual method. One subject was selected who had Angle Class I, normal dentition, without dental caries, periodontal disease and temporomandibular disorders. Forty times PVS impressions were taken and 10 pairs casts were fabricated using dental super hard stone. After mounting the casts with customized loading apparatus, 78.9kg/f force was loaded as a maximum biting force. In T-Scan method, occlusal contact points measurement was repeated twice. Then, using Photoshop program (Adobe photoshop CS3, Adobe. San Jose, USA), the pixels which indicated occlusal contact points by color was recognized, and the distribution of recognized pixels were calculated to area. In Add picture method, polyether bite material applied to the occlusal surface of the casts. Then, the image of the translucent areas was recorded and classified $0{\sim}10{\mu}m$, $0{\sim}30{\mu}m$, $0{\sim}60{\mu}m$ area by the amount of transmitted light. To acquire occlusal surface, the numbers of pixels from the photograph of the contact area indicated cast converted to $mm^2$. The mean occlusal contact area by two methods was statistically analyzed (paired t-test). Part of the red and pink area in T-Scan image were almost equivalent to the $0{\sim}10{\mu}m$, $0{\sim}30{\mu}m$, $0{\sim}60{\mu}m$ area in Add picture image. The distribution of occlusal contact points were similar, but the average area of occlusal contact points was wider in T-scan image (P<.05). Pink and red area in T-scan image was wider than $0{\sim}10{\mu}m$, $0{\sim}30{\mu}m$ area in Add picture image (P<.05), but similar to $0{\sim}60{\mu}m$area in Add picture image (P>.05). Occlusal contact points in T-scan image did not indicate real occlusal contact points. Occlusal contact areas in T-scan method were enlarged results comparing with those in Add picture method.

Development of Sensor System for Indoor Location-Based Service Implementation (실내 위치기반 서비스 구현을 위한 센서 시스템 개발)

  • Cha, Joo-Heon;Lee, Kyung-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.11
    • /
    • pp.1433-1439
    • /
    • 2012
  • This paper introduces a sensor system based on indoor locations in order to implement the Building Energy Management System. This system consists of a thermopile sensor and an ultrasonic sensor. The sensor module is rotated by $360^{\circ}$ and yawed up-and-down by two electric motors. Therefore, it can simultaneously detect the number and location of the inhabitants in the room. It uses wireless technology to communicate with the building manager or the smart-home server, and it can save electric energy by controlling the lighting system or heating/air conditioning equipment automatically. We also demonstrate the usefulness of the proposed system by applying it to a real environment.

Inductive Micro Thin Film Sensor for Metallic Surface Crack Detection (금속 표면결함 검출용 자기유도 마이크로 박막 센서)

  • Kim, Ki-Hyeon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.5
    • /
    • pp.395-400
    • /
    • 2008
  • Alternating magnetic field was used for detection of surface flaws on nonmagnetic and magnetic metallic specimens. The nondestructive sensor probe was composed of the planar coil with inductive magnetic thin film yoke as a sensing component and a single straight typed exciting coil. The planar inductive coil sensor with magnetic yoke was fabricated by sputtering, electroplating, dry etching and photolithography process. The alternative currents with the range of 0.1A to 1.0A (0.7 MHz to 1.8 MHz) were applied to the exciting coil. The specimens were prepared with the slit shaped artificial surface flaws (minimum depth and width; 0.5 mm) on metallic plate (Al; nonmagnetic metal and FeC; magnetic metal). The detected signal for the positions and shapes of surface flaws on specimens were obtained with high sensitivity and high signal to ratio. The measured output signals by the non-contacted scanning on surface of FeC specimen with micron-sized crack were converted to the images of the flaws. And these results were compared with the optical images, respectively.

Pedestrian Walking Velocity Estimation based on Wearable Inertial Sensors and Lower-limb Kinematics (착용형 관성센서 및 인체 하지부 기구학 기반의 보행자 속도추정에 관한 연구)

  • Kim, Myeong Kyu;Kim, Jong Kyeong;Lee, Donghun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.9
    • /
    • pp.799-807
    • /
    • 2017
  • In this paper, a new method is proposed for estimating pedestrians' walking velocity based on lower-limb kinematics and wearable inertial measurement unit (IMU) sensors. While the soles and ground are not in contact during the walking cycle, the walking velocity can be estimated by integrating the acceleration output of the inertial sensor mounted on the pelvis. To minimize the effects of acceleration measurement errors caused by the tilt of the pelvis while walking, the estimated walking velocity based on lower-limb kinematics is imposed as the initial value in the acceleration signal integration process of the pelvis inertial sensor. In the experiment involving outdoor walking for six minutes, sensor drift due to error accumulation was not observed, and the RMS error in the walking velocity estimation was less than 0.08 m/s.