• Title/Summary/Keyword: 점검사각지대

Search Result 24, Processing Time 0.025 seconds

The necessity of Introducing the In-service Test based on Analysis of Performance Test Result of Pressure Safety Valve (안전밸브 성능점검 자료 분석을 통한 운전 중 점검방법 도입의 필요성 고찰)

  • Jang, Yu Ri;Kim, Jeong Hwan;Kim, Seong Hee;Kwak, Young Hwan
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.6
    • /
    • pp.15-22
    • /
    • 2017
  • The pressure safety valve is very important device for securing the safety in the facilities which is operated by high pressure gases. The performance test should be periodically inspected by relate law because the failure of pressure safety valves might be main causes of serious accidents in the industrial fields. Shop test is mainly use for inspecting the performance test of pressure safety valves but the test method is not to be a solution for securing the safety. So, the development of alternative method is required. In this paper, there is a limit to securing the safety if the performance test is with just shop test. The limitation is checked from analysis result based on performance test results of pressure safety valves. The necessity for introducing the in-service test is reviewed to surmount the limitation. As a result, in-service test method should be developed and introduced to improve the inspection efficiency and economical loss. Also, it can be reduce the risk level.

Analysis of Appropriateness for Maintenance of Aged Small Bridges based on Condition and Load Carrying Capacity Evaluation (상태평가와 내하성능평가를 통한 소규모 노후교량의 유지관리 적정성 분석)

  • Lee, Huseok;Roh, Hwasung;Sun, Jong-Wan;Park, Kyung-Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.2
    • /
    • pp.59-66
    • /
    • 2019
  • Small bridges carry out only general inspections based on visual inspection. The Bridges with more than 30 years of public use need to be decided on whether or not they will be reconstruction according to aging. However, there are some situations that need to be determined only by appearance condition, which is insufficient in terms of safety maintenance. In this paper, the condition evaluation and the load carrying capacity evaluation were carried out for aged small bridges. A comparison of the evaluation results was conducted to examine the appropriateness of the maintenance related to the decision making of the reconstruction. As a result of reviewing, two of the bridges showed that there are no abnormality in the safety of the state evaluation, but the load capacity were insufficient. Thus evaluation the safety and performing the reconstruction decision of aged small bridges by visual inspection alone with may cause problems. Therefore, it is necessary to carry out additional research on the ambient measurement and load carrying capacity evaluation for the maintenance of the bridges, and to supplement it through application of the bridge management system.

The Implementation of Emergency Light Monitoring System by Intelligent Cluster Surveillance Network (지능형 클러스터 감시망 비상등관리시스템 개발)

  • Choi, Jae-Myeong;Kang, Heau-Jo
    • Journal of Advanced Navigation Technology
    • /
    • v.15 no.5
    • /
    • pp.906-912
    • /
    • 2011
  • In this paper, we structured the intelligent cluster surveillance network which can be managed scattered-the emergency light without communication line. Will not be interfered in location of emergency light and not to be will be able to establish the system. And the surveillance network there is by a destroyer and the communication relay system is born breakdown but the dead zone without condition of emergency light implemented the emergency light management system where the monitoring and management are possible. And we implemented the emergency light surveillance equipment and the emergency light monitoring system. Some experiments were conducted to verify so as to proposed system, and the system processes such as the surveillance network, the status information measurement and initialization were well performed.

The Proposed of Emergency Light Monitoring System by Self-Organization Radio Communication based on USN (USN기반 자율무선통신방식 비상등관리시스템 제안)

  • Choi, Jae-Myeong;Kang, Heau-Jo;Lee, Sang-Heon
    • Journal of Advanced Navigation Technology
    • /
    • v.13 no.2
    • /
    • pp.252-256
    • /
    • 2009
  • In this paper, the emergency light where is being scattered always inspection and will be able to manage from the management center. Is not interfered in data neck of a bottle actual condition and the data communication will be possible and the cluster monitor network will grow and uses establishes the emergency light monitoring system. Will not be interfered in location of emergency light and not to be will be able to establish the system. And the monitoring network there is by a destroyer and the communication relay system is born breakdown but the dead zone without condition of emergency light proposes the emergency light management system where the monitoring and management are possible.

  • PDF

Development of Remote Supervision System for Guam Lamps by Way of Leakage Current(Igr) Detection Method (보안등 전거설비의 Igr 누설전류 검출 및 원격감시장치 개발)

  • Choi, Myeong-Il;Kim, Young-Seok;Kim, Chong-Min;Bang, Sun-Bae
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.6
    • /
    • pp.75-80
    • /
    • 2010
  • The present study presented the implementation of a remote control/supervision system for guard lamps used in public illumination with little endeavor by far for safe management, which makes possible to supervise the state and to control the functions remotely including electric safety elements. Especially, the developed system adopts the measurement algorithm for detecting resistive leakage current(Igr) flowing based on the phase difference checkable for sensing at a monitor, being allowable for monitoring at MMI and transmitter for data transmittance. To verify reliability about the algorithm to accurately detect Igr leakage current, the laboratory-based functional test was performed.

A Study on the Improvement of Emergency Safety System as Social Protection System - Focusing on Alone Elderly and Severely Person with Disabilities - (사회적 보호체계로서의 응급안전시스템에 대한 개선방안 연구 -독거노인·중증장애인을 중심으로-)

  • Heo, Soo Kyung;Lim, Soo Jeong;Jeong, Jong Hwa
    • 재활복지
    • /
    • v.20 no.4
    • /
    • pp.31-54
    • /
    • 2016
  • The purpose of this study is to explore the improvement method of the emergency safety system as a social protection scheme for the elderly living alone with severe disabilities. The study was conducted by randomly choosing three regions in the metropolitan area (Jongno-gu, Seoul), the small-medium city (Yongin-si, Gyeonggi-do) and the rural area (Geochang-gun, Gyeongsangnam-do) among 17 cities and counties nationwide. The study method is based on the interview form of the structured questionnaires with city officials, county officials, and center operators. According to the results of the interview analysis, it was recognized that there was a need for an emergency safety system for the elderly living alone with severe disabilities. In spite of this necessity, there were problems about publicity for the discovery of victims of the blind spot in welfare, about inconvenience due to frequent malfunctions of the emergency equipment, about insufficient awareness of the security of the emergency officials and about supply and demand of manpower for 24-hour monitoring service. In order to improve the effective operation of the emergency safety system, it was the most urgent issue to formulate the legislation for responding to the crisis management of the vulnerable. A suggestion of this study is to build a safety system in which one-stop service is provided for the realization of compact welfare through the establishment of a MOU for linkage with community organizations, the full inspection of emergency equipment to solve safety equipment malfunction problems and the manpower supplement for 24-hour monitoring.

A Study on Damage factor Analysis of Slope Anchor based on 3D Numerical Model Combining UAS Image and Terrestrial LiDAR (UAS 영상 및 지상 LiDAR 조합한 3D 수치모형 기반 비탈면 앵커의 손상인자 분석에 관한 연구)

  • Lee, Chul-Hee;Lee, Jong-Hyun;Kim, Dal-Joo;Kang, Joon-Oh;Kwon, Young-Hun
    • Journal of the Korean Geotechnical Society
    • /
    • v.38 no.7
    • /
    • pp.5-24
    • /
    • 2022
  • The current performance evaluation of slope anchors qualitatively determines the physical bonding between the anchor head and ground as well as cracks or breakage of the anchor head. However, such performance evaluation does not measure these primary factors quantitatively. Therefore, the time-dependent management of the anchors is almost impossible. This study is an evaluation of the 3D numerical model by SfM which combines UAS images with terrestrial LiDAR to collect numerical data on the damage factors. It also utilizes the data for the quantitative maintenance of the anchor system once it is installed on slopes. The UAS 3D model, which often shows relatively low precision in the z-coordinate for vertical objects such as slopes, is combined with terrestrial LiDAR scan data to improve the accuracy of the z-coordinate measurement. After validating the system, a field test is conducted with ten anchors installed on a slope with arbitrarily damaged heads. The damages (such as cracks, breakages, and rotational displacements) are detected and numerically evaluated through the orthogonal projection of the measurement system. The results show that the introduced system at the resolution of 8K can detect cracks less than 0.3 mm in any aperture with an error range of 0.05 mm. Also, the system can successfully detect the volume of the damaged part, showing that the maximum damage area of the anchor head was within 3% of the original design guideline. Originally, the ground adhesion to the anchor head, where the z-coordinate is highly relevant, was almost impossible to measure with the UAS 3D numerical model alone because of its blind spots. However, by applying the combined system, elevation differences between the anchor bottom and the irregular ground surface was identified so that the average value at 20 various locations was calculated for the ground adhesion. Additionally, rotation angle and displacement of the anchor head less than 1" were detected. From the observations, the validity of the 3D numerical model can obtain quantitative data on anchor damage. Such data collection can potentially create a database that could be used as a fundamental resource for quantitative anchor damage evaluation in the future.

A Study on Effective Fire Countermeasures for Facilities for the Elderly and Children (노유자시설의 효율적인 화재 대응방안에 관한 연구)

  • Hwang, Euy-Hong;Choi, Han-Bit;Choi, Doon-Mook
    • Fire Science and Engineering
    • /
    • v.34 no.4
    • /
    • pp.107-114
    • /
    • 2020
  • With the development of the national industry, the importance of the elderly and children such as the elderly, disabled, and children is recognized. Similarly, the number of facilities for the elderly and children is increasing. Fires at facilities for the elderly and children cause heavy casualties. In response to these events, it is essential to activate fire alarms promptly and accurately and to secure evacuation routes. In this study, the laws and statistics related to facilities for elderly and children were reviewed, and problems with legal terms-such as elderly, children, others, unwanted alarm of fire alarm systems, blind spots of fire compartment standards, securing evacuation routes, and absence of standards for life safety rescue organizations-were identified. As an improvement measure, the legal definitions of similar terms-such as elderly, children, unwanted alarm checklist, and establishment of standards for fire prevention compartment-and introduction of other terms-evacuation elevators, the establishment of standards for life-safety rescue organizations, and provision of flame retardation objects for evacuees-were proposed.

A Validation of Effectiveness for Intrusion Detection Events Using TF-IDF (TF-IDF를 이용한 침입탐지이벤트 유효성 검증 기법)

  • Kim, Hyoseok;Kim, Yong-Min
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.28 no.6
    • /
    • pp.1489-1497
    • /
    • 2018
  • Web application services have diversified. At the same time, research on intrusion detection is continuing due to the surge of cyber threats. Also, As a single-defense system evolves into multi-level security, we are responding to specific intrusions by correlating security events that have become vast. However, it is difficult to check the OS, service, web application type and version of the target system in real time, and intrusion detection events occurring in network-based security devices can not confirm vulnerability of the target system and success of the attack A blind spot can occur for threats that are not analyzed for problems and associativity. In this paper, we propose the validation of effectiveness for intrusion detection events using TF-IDF. The proposed scheme extracts the response traffics by mapping the response of the target system corresponding to the attack. Then, Response traffics are divided into lines and weights each line with an TF-IDF weight. we checked the valid intrusion detection events by sequentially examining the lines with high weights.

The Proposition of Domestic Sprinklers Installation Standard and the Fire Services Act (국내 스프링클러 설치기준과 소방관련 법에 관한 고찰)

  • Kim, Yong-Moon;Lee, Young-Jai
    • Journal of Korean Society of Disaster and Security
    • /
    • v.7 no.2
    • /
    • pp.17-24
    • /
    • 2014
  • Recently, many accidents occur frequently because sprinklers aren't installed or don't work right when there are outbreak of fire in houses and aggregate buildings. Therefore, they can result in damage for humans and loss of property. Sprinklers are the most appropriate which can extinguish buildings' fire in the initial stages. Through lack of legal system, in domestic cases, sprinklers cannot operate their inherent performance. Domestic standard simply classifies installation objects according to types of business and forms of buildings, also divides into uses and floors of buildings. Especially it only regulates that sprinklers must be installed every floors in particular fire buildings that have more than eleven floors. While it doesn't need to install sprinklers below ten floors, so we are threatened the safety. In this study, we derived causes and implications by analyzing concepts of sprinklers facilities, installation standards in domestic and foreign legal system, and recent cases that expanded damages in fire accidents because of weak point of installation and control standards. In domestic cases, as a result, government has to provide an institutional strategy and law that regulate duty to install sprinklers to all aggregate buildings regardless of floors in terms of new buildings. Also, if someone who has existing buildings wanted to install them, government would guarantee subsidy to encourage installation. In addition, government supervises fire-fighting activities when there are fire by compensating standards about regular inspection by a qualified technician, operation and maintenance of sprinklers as well as reinforcement of administrative criteria.