• Title/Summary/Keyword: 전자 장비

Search Result 2,063, Processing Time 0.034 seconds

The Measurement Algorithm for Microphone's Frequency Character Response Using OATSP (OATSP를 이용한 마이크로폰의 주파수 특성 응답 측정 알고리즘)

  • Park, Byoung-Uk;Kim, Hack-Yoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.26 no.2
    • /
    • pp.61-68
    • /
    • 2007
  • The frequency response of a microphone, which indicates the frequency range that a microphone can output within the approved level, is one of the most significant standards used to measure the characteristics of a microphone. At present, conventional methods of measuring the frequency response are complicated and involve the use of expensive equipment. To complement the disadvantages, this paper suggests a new algorithm that can measure the frequency response of a microphone in a simple manner. The algorithm suggested in this paper generates the Optimized Aoshima's Time Stretched Pulse(OATSP) signal from a computer via a standard speaker and measures the impulse response of a microphone by convolution the inverse OATSP signal and the received by the microphone to be measured. Then, the frequency response of the microphone to be measured is calculated using the signals. The performance test for the algorithm suggested in the study was conducted through a comparative analysis of the frequency response data and the measures of frequency response of the microphone measured by the algorithm. It proved that the algorithm is suitable for measuring the frequency response of a microphone, and that despite a few errors they are all within the error tolerance.

Process Optimization for the Industrialization of Transparent Conducting Film (투명 전도막의 산업화를 위한 공정 최적화)

  • Nam, Hyeon-bin;Choi, Yo-seok;Kim, In-su;Kim, Gyung-jun;Park, Seong-su;Lee, Ja Hyun
    • Industry Promotion Research
    • /
    • v.9 no.1
    • /
    • pp.21-29
    • /
    • 2024
  • In the rapidly advancing information society, electronic devices, including smartphones and tablets, are increasingly digitized and equipped with high-performance features such as flexible displays. This study focused on optimizing the manufacturing process for Transparent Conductive Films (TCF) by using the cost-effective conductive polymer PEDOT and transparent substrate PET as alternatives to expensive materials in flexible display technology. The variables considered are production speed (m/min), coating maximum temperature (℃), and PEDOT supply speed (rpm), with surface resistivity (Ω/□) as the response parameter, using Response Surface Methodology (RSM). Optimization results indicate the ideal conditions for production: a speed of 22.16 m/min, coating temperature of 125.28℃, and PEDOT supply at 522.79 rpm. Statistical analysis validates the reliability of the results (F value: 18.37, P-value: < 0.0001, R2: 0.9430). Under optimal conditions, the predicted surface resistivity is 145.75 Ω/□, closely aligned with the experimental value of 142.97 Ω/□. Applying these findings to mass production processes is expected to enhance production yields and decrease defect rates compared to current practices. This research provides valuable insights for the advancement of flexible display manufacturing.

Review on Usefulness of EPID (Electronic Portal Imaging Device) (EPID (Electronic Portal Imaging Device)의 유용성에 관한 고찰)

  • Lee, Choong Won;Park, Do Keun;Choi, A Hyun;Ahn, Jong Ho;Song, Ki Weon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.1
    • /
    • pp.57-67
    • /
    • 2013
  • Purpose: Replacing the film which used to be used for checking the set-up of the patient and dosimetry during radiation therapy, more and more EPID equipped devices are in use at present. Accordingly, this article tried to evaluated the accuracy of the position check-up and the usefulness of dosimetry during the use of an electronic portal imaging device. Materials and Methods: On 50 materials acquired with the search of Korea Society Radiotherapeutic Technology, The Korean Society for Radiation Oncology, and Pubmed using "EPID", "Portal dosimetry", "Portal image", "Dose verification", "Quality control", "Cine mode", "Quality - assurance", and "In vivo dosimetry" as indexes, the usefulness of EPID was analyzed by classifying them as history of EPID and dosimetry, set-up verification and characteristics of EPID. Results: EPID is developed from the first generation of Liquid-filled ionization chamber, through the second generation of Camera-based fluoroscopy, and to the third generation of Amorphous-silicon EPID imaging modes can be divided into EPID mode, Cine mode and Integrated mode. When evaluating absolute dose accuracy of films and EPID, it was found that EPID showed within 1% and EDR2 film showed within 3% errors. It was confirmed that EPID is better in error measurement accuracy than film. When gamma analyzing the dose distribution of the base exposure plane which was calculated from therapy planning system, and planes calculated by EDR2 film and EPID, both film and EPID showed less than 2% of pixels which exceeded 1 at gamma values (r%>1) with in the thresholds such as 3%/3 mm and 2%/2 mm respectively. For the time needed for full course QA in IMRT to compare loads, EDR2 film recorded approximately 110 minutes, and EPID recorded approximately 55 minutes. Conclusion: EPID could easily replace conventional complicated and troublesome film and ionization chamber which used to be used for dosimetry and set-up verification, and it was proved to be very efficient and accurate dosimetry device in quality assurance of IMRT (intensity modulated radiation therapy). As cine mode imaging using EPID allows locating tumors in real-time without additional dose in lung and liver which are mobile according to movements of diaphragm and in rectal cancer patients who have unstable position, it may help to implement the most optimal radiotherapy for patients.

  • PDF

Properties of Indium Tin Oxide Thin Films According to Oxygen Flow Rates by γ-FIB System (γ-FIB 시스템을 이용한 산소 유량 변화에 따른 산화인듐주석 박막의 특성 연구)

  • Kim, D.H.;Son, C.H.;Yun, M.S.;Lee, K.A.;Jo, T.H.;Seo, I.W.;Uhm, H.S.;Kim, I.T.;Choi, E.H.;Cho, G.S.;Kwon, G.C.
    • Journal of the Korean Vacuum Society
    • /
    • v.21 no.6
    • /
    • pp.333-341
    • /
    • 2012
  • Indium Tin Oxide (ITO) thin films were prepared by RF magnetron sputtering with different flow rates of $O_2$ gas from 0 to 12 sccm. Electrical and optical properties of these films were characterized and analyzed. ITO deposited on soda lime glass and RF power was 2 kW, frequency was 13.56 MHz, and working pressure was $1.0{\times}10^{-3}$ Torr, Ar gas was fixed at 1,000 sccm. The transmittance was measured at 300~1,100 nm ranges by using Photovoltaic analysis system. Electrical properties were measured by Hall measurement system. ITO thin films surface were measured by Scanning electron microscope. Atomic force microscope surface roughness scan for ITO thin films. ITO thin films secondary electron emission coefficient(${\gamma}$) was measured by ${\gamma}$-Focused ion beam. The resistivity is about $2.4{\times}10^{-4}{\Omega}{\cdot}cm$ and the weighted average transmittance is about 84.93% at 3 sccm oxygen flow rate. Also, we investigated Work-function of ITO thin films by using Auger neutralization mechanism according to secondary electron emission coefficient(${\gamma}$) values. We confirmed secondary electron emission peak at 3 sccm oxygen flow rate.

Analysis of the Range Verification of Proton using PET-CT (Off-line PET-CT를 이용한 양성자치료에서의 Range 검증)

  • Jang, Joon Young;Hong, Gun Chul;Park, Sey Joon;Park, Yong Chul;Choi, Byung Ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.101-108
    • /
    • 2017
  • Purpose: The proton used in proton therapy has a characteristic of giving a small dose to the normal tissue in front of the tumor site while forming a Bragg peak at the cancer tissue site and giving up the maximum dose and disappearing immediately. It is very important to verify the proton arrival position. In this study, we used the off-line PET CT method to measure the distribution of positron emitted from nucleons such as 11C (half-life = 20 min), 150 (half-life = 2 min) and 13N The range and distal falloff point of the proton were verified by measurement. Materials and Methods: In the IEC 2001 Body Phantom, 37 mm, 28 mm, and 22 mm spheres were inserted. The phantom was filled with water to obtain a CT image for each sphere size. To verify the proton range and distal falloff points, As a treatment planning system, SOBP were set at 46 mm on 37 mm sphere, 37 mm on 28 mm, and 33 mm on 22 mm sphere for each sphere size. The proton was scanned in the same center with a single beam of Gantry 0 degree by the scanning method. The phantom was scanned using PET-CT equipment. In the PET-CT image acquisition method, 50 images were acquired per minute, four ROIs including the spheres in the phantom were set, and 10 images were reconstructed. The activity profile according to the depth was compared to the dose profile according to the sphere size established in the treatment plan Results: The PET-CT activity profile decreased rapidly at the distal falloff position in the 37 mm, 28 mm, and 22 mm spheres as well as the dose profile. However, in the SOBP section, which is a range for evaluating the range, the results in the proximal part of the activity profile are different from those of the dose profile, and the distal falloff position is compared with the proton therapy plan and PET-CT As a result, the maximum difference of 1.4 mm at the 50 % point of the Max dose, 1.1 mm at the 45 % point at the 28 mm sphere, and the difference at the 22 mm sphere at the maximum point of 1.2 mm were all less than 1.5 mm in the 37 mm sphere. Conclusion: To maximize the advantages of proton therapy, it is very important to verify the range of the proton beam. In this study, the proton range was confirmed by the SOBP and the distal falloff position of the proton beam using PET-CT. As a result, the difference of the distally falloff position between the activity distribution measured by PET-CT and the proton therapy plan was 1.4 mm, respectively. This may be used as a reference for the dose margin applied in the proton therapy plan.

  • PDF

Clinical Application of 11C-Acetate Positron Emission Tomography-Computed Tomography (PET-CT) in Patients of Urinary System Cancer (비뇨기암 환자에서 11C-Acetate 양전자 방출 컴퓨터 단층 검사 (PET-CT)의 임상 적용)

  • Nam-Koong, Hyuk;Ham, Joon chul;Kim, Sang kyoo;Choi, Yong hoon;Lim, Han sang;Kim, Jae sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.9-13
    • /
    • 2016
  • Purpose PET-CT examinations using $^{18}F-FDG$ to treat urinary system cancer are limited in terms of anatomical structure and excretion route of $^{18}F-FDG$. But one of the ongoing examinations utilizing $^{11}C-Acetate$ can compensate for such defects. We would like to introduce a clinical application of $^{11}C-Acetate$ PET-CT in urinary cancer patients. Materials and Methods We conducted a clinical survey of 22 patients diagnosed with urinary cancer at our hospital, 10 prostate cancer patients, 10 renal cell carcinoma patients, and 2 bladder cancer patients. All patients were performed $^{18}F-FDG$ PET-CT examinations, $^{11}C-Acetate$ examinations were performed after two weeks on average. The equipment used to D-710 PET-CT in GE Company and we performed PET-CT procedures 15 minutes after injecting $^{11}C-Acetate$, and a medical doctor from the department of nuclear medicine appraised and compared images between $^{18}F-FDG$ and $^{11}C-Acetate$. Results According to our survey, prostate cancer patients generally had lower uptake of $^{18}F-FDG$ than other cancer patients did. In 2 out of 10 prostate cancer patients, metastasized cancer showed greater uptake in $^{11}C-Acetate$ than $^{18}F-FDG$. In renal cell carcinoma cases, 8 out of 10 patients displayed evidently greater uptake in $^{11}C-Acetate$ than $^{18}F-FDG$. We excluded bladder cancer cases in this study because uptake of $^{18}F-FDG$ in the bladder was too hot, the number of patients was insufficient, and the cases did not meet criteria such as the use of diuretics. Conclusion It is too premature to draw solid conclusions from the survey, since it involved only a small number of participants. However, there are a number of studies conducted abroad that prove the effectiveness of the $^{11}C-Acetate$ PET-CT examinations in treating urinary system cancer, and this study is still ongoing at our hospital. If the tests were to be conducted on a larger number of participants, this study could lead to numerous other potential research topics, such as the correlation between Prostatic specific antigen (PSA) values and $^{11}C-Acetate$ PET-CT, Gleason sum values from biopsy before surgery, Specificity, sensitivity, positive predictive value (PPV), negative predictive value (NPV) between $^{18}F-FDG$ PET-CT examinations and $^{11}C-Acetate$ PET-CT examinations in other urinary system cancers.

  • PDF

Settling Characteristics of Natural Loess Particles in Seawater (해수 중에서 자연상태 황토입자의 침강특성)

  • KIM Sung-Jae
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.32 no.6
    • /
    • pp.706-712
    • /
    • 1999
  • PSD (particle size distribution) for 2,000 mg/$\ell$ natural loess in seawater showed normal distribution cure at 0 minute settling time, accompanying with very large particle distribution range with its mean particle diameter of 31.6 $\mu$m and coencient of variance of $72.6\%$, With elapsed time it showed that the PSD was rapidly changed from normal distribution cure to abnormal distribution curve, steepened the right-hand side of it and its coefficient of variance was getting increased because of rapid settling of large size particles, Cumulative weight distribution showed that 2,000 mg/$\ell$ natural loess in seawater was almost $100\%$ constituted of particles bigger than 20 $\mu$m in diameter. Ratio of $V_s/(D_{bm})^{1/2}$ for loess particles in seawater was increased with increase of particle size in geometrical progression. Almost all loess particles in seawater had Stokes settling velocity not less than 2,255 times of Brownian diffusion coefficient, There was almost to EDL (about 0.4 nm) around natural loess particles in seawater, Thus, there was always LVDW attractive force between loess particles approaching each other in seawater, and almost no EDL repulsive force. Loess particles were not always in the condition of easy floe formation. Concentration of natural loess in seawater increasing from 400 mg/$\ell$ to 10,000 mg/$\ell$, characteristics of the settling was changed from Type I settling (discrete settling) to Type II settling (flocculation settling). PVD (particle volume distribution) showed that natural loess particles in seawater were largely constituted of two types of particles, such as rapidly settling particles and suspended and dispersed particles for a long time. Amount of the latter was much less than that of the former.

  • PDF

Performance Estimation of Large-scale High-sensitive Compton Camera for Pyroprocessing Facility Monitoring (파이로 공정 모니터링용 대면적 고효율 콤프턴 카메라 성능 예측)

  • Kim, Young-Su;Park, Jin Hyung;Cho, Hwa Youn;Kim, Jae Hyeon;Kwon, Heungrok;Seo, Hee;Park, Se-Hwan;Kim, Chan Hyeong
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.1
    • /
    • pp.1-9
    • /
    • 2015
  • Compton cameras overcome several limitations of conventional mechanical collimation based gamma imaging devices, such as pin-hole imaging devices, due to its electronic collimation based on coincidence logic. Especially large-scale Compton camera has wide field of view and high imaging sensitivity. Those merits suggest that a large-scale Compton camera might be applicable to monitoring nuclear materials in large facilities without necessity of portability. To that end, our research group have made an effort to design a large-scale Compton camera for safeguard application. Energy resolution or position resolution of large-area detectors vary with configuration style of the detectors. Those performances directly affect the image quality of the large-scale Compton camera. In the present study, a series of Geant4 Monte Carlo simulations were performed in order to examine the effect of those detector parameters. Performance of the designed large-scale Compton camera was also estimated for various monitoring condition with realistic modeling. The conclusion of the present study indicates that the energy resolution of the component detector is the limiting factor of imaging resolution rather than the position resolution. Also, the designed large-scale Compton camera provides the 16.3 cm image resolution in full width at half maximum (angular resolution: $9.26^{\circ}$) for the depleted uranium source considered in this study located at the 1 m from the system when the component detectors have 10% energy resolution and 7 mm position resolution.

An Empirical Study on Classification, Business Type, Organizational Culture on Performance of Korean IT SMEs·Venture (중소·벤처기업의 업종, 영업형태, 조직문화가 기업성과에 미치는 영향에 관한 연구: 삼원분산분석(3-way ANOVA)을 중심으로)

  • Roh, Doo-Hwan;Hwang, Kyung-Ho
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.14 no.2
    • /
    • pp.221-233
    • /
    • 2019
  • In Korea, small and medium sized domestic enterprises(SMEs) play an pivotal role in the national economy, accounting for 99.9% of all enterprises, 87.9% of total employment, and 48.3% of production. and SMEs was driving a real force of the development of national economy in many respects such as innovation, job creation, industrial diversity, balanced regional development. Despite their crucial role in the national development, most of SMEs suffer from a lack of R&D capabilities and equipments as well as funding capacity. Public R&D institutes can provide SMEs with valuable supplementary technological knowledge and help them build technological capacity. so, In order to effectively support SMEs, government and public R&D institutes must be a priority to know about the factors influencing the performance related to technology transfer and technological collaborations. In particular, SMEs are not only taking up a large portion of the national economy, but also their influence in politics and economy so strong that raising the competitiveness of small and medium-sized companies is a national policy goal that must be achieved in order to achieve sustained economic growth. For this reason, it is necessary to look specifically at the relationship between concepts such as the environment, strategy, and organizational culture surrounding the enterprise to enhance the competitiveness of SMEs. The paper analyzes 665 companies to find out which organizational culture affects their performance by classification and type of business of SMEs. This study demonstrated that when SMEs seek consistency in their external environment, strategies, and organizational structure to maintain their continued competitiveness. According to three-way analysis of variance (3-way ANOVA) indicates that classification of industries in SMEs has statistically significant main effects, but the type of business and organizational culture do not have significant effects. However, the company's organizational performance (operating profit) of SMES were found to differ significantly in comparison between groups according to classification standards of industries, and therefore adopted some parts. In addition, an analysis of the effect of interaction between the three independent variables of small and medium-sized enterprises has shown that there are statistically significant interaction effects among classification, types of business, and organizational cultures. The results shows that there is an organizational culture suitable for each industry classification and type of business of an entity, and is expected to be used as a basis for establishing promotion policies related to the incubation and commerciality of small and medium-sized venture companies in the future.

A Comparative Study of Production of [68Ga]PSMA-11 with or without Cassette Type Modules (비 카세트 방식과 카세트 방식을 이용한 [68Ga]PSMA-11의 자동 합성 방법 비교)

  • Hyun-Sik, Park;Byeong-Min, Jo;Hyun-Ho, An;Hong-Jin, Lee;Jin-Hyeong, Lee;Gyeong-Jae, Lee;Byung-Chul, Lee;Won-Woo, Lee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.26 no.2
    • /
    • pp.15-19
    • /
    • 2022
  • Purpose [68Ga]PSMA-11 is needed the high reproducibility, excellent radiochemical yield and purity. In term of radiation safety, the radiation exposure of operator for its production also should be considered. In this work, we performed a comparative study for the fully automated synthesis of [68Ga]PSMA-11 between non-cassette type and cassette type. Materials and Methods Two different type of modules (TRACERlab FX N pro for non-cassette type and BIKBox for cassette type) were used for the automated production of [68Ga]PSMA-11. According to the previously identified elution profile, Only 2.5 ml with high radioactivity was used for the reaction. After adjusting the pH of the reaction solution with HEPES buffer solution, the precursor was added and reacted with at 95 ℃ for 15 minutes. The reaction mixture was separated and purified using a C18 light cartridge. The product was eluted with 50% EtOH/saline solution and diluted with saline. It was completed by sterilizing filter. In the non-cassette type, the aforementioned process must be prepared directly. However, in the cassette method, synthesis was possible simply by installing a kit that was already completed. Results Both total [68Ga]PSMA-11 production time were 25±3(non-cassette type) and 23±3 minutes(cassette type). The radiochemical yield of the non-cassette type(65.5±5.7%) was higher than that of the cassette type(61.6±4.8%) after sterilization filter. The non-cassette type took about 120 minutes of preparation time before synthesis due to washing of synthesizer and reagent preparation. However, since the cassette type does not require washing and reagent preparation, it took about 20 minutes to prepare before synthesis. Both type of synthesizer had a radiochemical high purity(>99%). Conclusion The non-cassette type production of [68Ga]PSMA-11 showed higher radiochemical yield and lower cost than the cassette type. However, The cassette type has an advantage in terms of preparation time, convenience, and equipment maintenance.