• Title/Summary/Keyword: 전자파 생체 영향

Search Result 34, Processing Time 0.027 seconds

A Study on the Reflection of Rabbit Nervous Tissue After Electromagnetic Irradiation and the Effect of Nimodipine Injection (전자파에 노출된 토끼의 뇌신경조직의 반응과 Nimodipine 투여효과에 관한 연구)

  • 이근호;김영태
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.1
    • /
    • pp.81-90
    • /
    • 1998
  • Electromagnetic waves may induce various effects on nervous tissues either by thermal or non-thermal mechanisms. This paper intoduces a method to evalute the non-thermal effect to central nervous system by measuring the EEGs of the rabbits treated by nimodipine before exposed to weak microwave field. 20 rabbits were divided into 2 groups and their EEGs were measured after their head section were exposed to 2,450 MHz microwave with the power density of 10 dBm and 20 dBm respectively for 10 minutes and compared with those of the 3rd group of 10 rabbits which were not exposed. The 4th group of 10 rabbits were intravenously given with nimodipine before exposed to 20 dBm field to determine whether this drug would reverse the EEGs changes induced by weak microwave irradiation. As field poser exceeded 20 dBm although no significant physiological changes were observed, total induced EEGs power was remarkably decreased suggesting the presence of CNS activation. Using Fourier analysis on the EEGs signal it was found that remarkable decrease in delta band and increase in the alpha and beta bands in a significant manner(P<0.05) compared to control group. The changes were, however, not reversed by nimodipine-treatment. The effects may be pure thermal in nature because no significant change has been observed in nimodipine treated rabbits.

  • PDF

A Study on Application of FIR to the Braun tube and Lnfluence of Braun tube of FIR-radiation Type to a Living Organism(I) (원적외선의 브라운관에의 응용과 생체에 미치는 영향에 대한 연구(I))

  • 김헌수;박종환
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.9 no.1
    • /
    • pp.30-36
    • /
    • 1995
  • Until now, simple shielding is the only way to prevent harmful electromagnetic: wave from TV and monitor. In this study, we adopted special ceramics to Braun tube for radiating FIR ray. In experiment on living organisms, there was some differences between general and ceramics treated Braun tube. The chrysanthemunm the drosophila and the tadpole which were in front of ceramics treated Braun tube showed longer living activity than those in front of general tube. As a result, it is proved that the ceramics treated Braun tube offers good effects to living organisms.

  • PDF

Design of a Magnetic Field Source for In Vivo Experiments at Extremely Low Frequency (생체 실험용 극저주파 자기장 발생 장치의 설계)

  • 김정호;김윤명
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.8
    • /
    • pp.871-877
    • /
    • 2003
  • In this paper, the design parameters for the magnetic field source at extremely low frequency are proposed. This facility can be used fur in vivo experiments with small animals to investigate biological response to the driving magnetic fields. In case that the exposed animals are motionless, the animals may be affected by the directivity of driving field. To avoid this effect, a 2-axis ELF magnetic field driving apparatus was designed. The optimum location and number of turns of each coil were obtained by numerical analysis. Applying these data to the MATLAB code(for computation), the magnetic field distribution was obtained. The calculation result fur a well-designed facility showed that the space in which the amplitude of the magnetic field lies within the 95 % of the magnetic field distribution was more than 60 % of each axis length.

Electromagnetic Interactions between a Cellular Phone and the Human Body and Synthesis of a Bone-Equivalent Material (휴대폰 전자파와 인체의 상호 영향 및 뼈 유사 물질 합성 연구)

  • 윤용섭;김인광;전중창;박위상
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.2
    • /
    • pp.277-290
    • /
    • 1999
  • A simulation using the finite-difference time-domain method to analyze the electromagnetic interactions between a cellular phone and the human body was conducted, and a synthesis of a bone-equivalent material to make a human head phantom was performed. A test model of the cellular phone was fabricated to measure its reflection coefficient and radiation pattern in the free space. Various effects of the human body on the characteristics of the phone, such as input impedance, reflection coefficient, radiation pattern, and radiation efficiency are analyzed as the distance between the head and the phone antenna varies. When the phone was operated close to the head, the resonant frequency of the antenna decreased by up to 12%. With the output power of 0.6W, as long as the distance was larger than 30mm, the 1-g averaged peak SAR was below the ANSI/IEEE safety guideline, 1.6 W/kg. To synthesize the bone-equivalent material, an epoxy with hardener and a graphite powder were used as basis ingredients, and a small amount of a conducting epoxy was added to control the conductivity of the material. A material having a relative permittivity of 18.04 and a conductivity of 0.347, which are close to those of the bone at 850 MHz, was synthesized.

  • PDF

Implementation of Wavelet Transform for a Real time Monitoring ECG Telemetry System (웨이브렛 변환을 이용한 실시간 모니터링 ECG 텔레미트리 시스템 구현)

  • 박차훈;서희돈
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.3 no.1
    • /
    • pp.27-32
    • /
    • 2002
  • In this study, we fabricated the advanced telemetry system that transmitting media use radio frequency(RF) for the middle range measurement of the physiological signals and receiving media use optical for electromagnetic interference problem. The telemetry system within a size of 65$\times$125$\times$45mm consists of three parts: RF transmitter, optical receiver and physiological signal processing CMOS one chip. Advantages of proposed telemetry system is wireless middle range(50m) FM transmission, reduce electromagnetic interference to a minimum which enables a comfortable bed-side telemetry system. The monitoring system was designed in the structure of dual-processor for the real time processing. The use of the one channel in our study made it possible the real time wavelet transformation of electrocardiogram data of 360Hz, 16 bits for every 1.42 seconds.

  • PDF

The analysis of RF dosimetric uncertainties by using statistical method at in-vivo and in-vitro experiments (RF 전자기장 생체 영향 실험에서 통계적 방법을 통한 전자기장 노출 불확실성 분석)

  • Choi, Sung-Ho;Kim, Nam
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2003.11a
    • /
    • pp.74-78
    • /
    • 2003
  • This paper shows the dosimetric uncertainties of electromagnetic field at in-vivo and in-vitro experiments. For more accurate consequences of these researches, we have tried to find out any correlations among output power, power density and specific absorption rate(SAR) with the results of in-vivo, in-vitro tests and SAR reports of cellular phone and PDA. In the case of in-vivo tests, the power density has close statistical correlations with SAR value and in the event of in-vitro tests, the output power has considerable statistical correlations with SAR containing duty factor. On the other hand, we found that both power density and output power don't have any close correlations with SAR. And, we obtained fitted regression form among frequency, power density and SAR containing duty factor through multiple linear regression analysis.

  • PDF

Technical Trends of In Vitro Exposure System (전자파 세포노출장치 기술 동향)

  • Lee, Y.S.;Jeon, S.B.;Choi, H.D.
    • Electronics and Telecommunications Trends
    • /
    • v.37 no.3
    • /
    • pp.33-40
    • /
    • 2022
  • Communication technologies are evolving to meet the ever-increasing demand for fast transmission speeds and large capacity. However, the introduction of new mobile networks, such as 5G, should be accompanied by changes in corresponding frequency and modulation techniques to enable the commercialization of its services. Hence, investigating the human health effects of electromagnetic exposures used in these new communication systems is crucial. Since in vitro electromagnetic experiments can provide essential information on important mechanisms of exposure effects, this article presents in vitro exposure systems necessary for reliable experiments. Moreover, the fundamental requirements for system implementation and the features of various systems are discussed.

Input Power Determination of TEM Cell Due to SAR for Mobile Phone Wave Blood Exposure (휴대폰 전자파의 혈액 조사를 위한 SAR별 TEM 셀의 입력 전력 산출)

  • Youn Ji-Hun;Son Tae-Ho
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.8 s.99
    • /
    • pp.810-814
    • /
    • 2005
  • Input power for TEM cell apparatus due to SAR(Specific Absorption Rate) for culture blood cell is determined by the transmission and reflection measurement of blood into the TEM cell. Blood cell with skin cell are reference culture cells for the study of EM wave effect. Exposure RF power from exposure apparatus to culture cell should not only exact for SAR value, but also should be based on the theoretical theory. In this paper, insertion loss of 50 g blood was measured to know exposure power per gram for culture blood cell, and input power of TEM cell due to SAR 0.8, 1.6, 3, 4 mW/g using the measured data are delivered. This study is for applying to EM wave exposure apparatus to culture cell.

Temperature Measurement for the Human Head under Local Exposure of Electromagnetic Wave with 800MHz (800MHz대의 전자파에 노출된 두부의 온도 측정)

  • Park, Ju-Tae
    • Journal of the Korean Institute of Telematics and Electronics T
    • /
    • v.36T no.2
    • /
    • pp.70-76
    • /
    • 1999
  • With the recent increase in the use among young children of portable telephone public concern regarding potential health hazards due to a hot spot appearing inside the infant head, has been growing. Since the biological hazards due to RF exposure are caused mainly by a temperature-rise in tissue, the effect of localized SAR for portable telephones should also be related to the temperature-rise in the human head. In this paper, it was measured that in the actual use of portable telephone the temperature of the local tissue in the human-head change. As a result, it should be noted that the mean temperature of human-body and localized tissue is rising from beginning call. However the temperature variation of localized tissue is recovered rapidly as normal temperature, although the mean temperature of human-body rising continuously at ending call of portable telephone.

  • PDF

The Statistical Technique for Dosimetric Meta-Analysis at in-vivo and in-vitro Papers about Bioeffects of RF Electromagnetic Field (RF 전자기장 생체 영향 연구 문헌에서 노출량 메타분석을 위한 통계적 기법)

  • Choi, Sung-Ho;Kim, Nam
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.12
    • /
    • pp.1311-1320
    • /
    • 2003
  • This paper proposed the estimating method of electromagnetic dosimetric reliability at in-vivo and in-vitro experiments. For more accurate consequences of these researches, we have tried to find out any correlations among output power, power density and specific absorption rate(SAR) with the results of in-vivo, in-vitro tests and SAR reports of cellular phone and PDA. In the case of in-vivo tests, the power density has close statistical correlations with SAR value and in the event of in-vitro tests, the output power has considerable statistical correlations with SAR containing duty factor. We analysed the coefficient of determination to estimate the dosimeoic uncertainty. If we use this method before evaluating techniques of measurement and analysis at both in-vivo and in-vitro experiments, we will conduct more accurate reliability test.