• Title/Summary/Keyword: 전자파영향

Search Result 827, Processing Time 0.027 seconds

Analysis of Human Exposure to Wideband Pulse EMF Dependent on the Dispersion Algorithm (분산 알고리즘에 따른 광대역 펄스 전자파 노출에 대한 인체 노출량 해석)

  • Ka Won-Suk;Kim Tae-Hong;Kim Jeong-Ran;Pack Jeong-Ki
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.7 s.110
    • /
    • pp.684-693
    • /
    • 2006
  • In this paper, the SA (Specific Absorption) distribution in a human head, exposed to wideband pulse EMF, has been analyzed by taking into account the dispersion characteristics of biological tissues. The dispersive properties of biological tissues are characterized by the 4th Cole-Cole model. Currently, there is no dispersive FDTD algorithm to implement the 4th Cole-Cole model accurately. Thus, in this paper the FDTD methods with the dispersive algorithm for the 1st-order Cole-Cole model and the 3rd-order Debye model were used for SA analysis. The validity of each model has been investigated first, and then the effects of dispersion on SA distribution have been studied.

Effects of Cacti on the Protection against Low Frequency Electromagnetic Waves Radiated from Computer Monitor (컴퓨터 모니터 발생 전자파 차단에 미치는 선인장의 효과 유무)

  • Son, Ki-Cheol;Ryu, Myung-Hwa;Park, Woong-kyu
    • Horticultural Science & Technology
    • /
    • v.17 no.6
    • /
    • pp.773-776
    • /
    • 1999
  • Effects of cacti and a few indoor plants on the protection of the harmful electromagnetic waves (ELF: extremely low frequency and VLF: very low frequency bands) radiated from the monitor of computer were investigated in indoor condition. The front screen of monitor evoked the highest amounts of electromagnetic waves as compared to other positions. Therefore, plants and other objects were placed on the front or side of monitor in order to measure electromagnetic waves. It was shown that all plants including cacti did not have any effect on the reduction of magnetic waves in both ELF and VLF, regardless of species and varieties, sizes, and dispositions. In the case of electric waves, however, there was a little reduction by cacti, depending upon several treatments mentioned before, but the measured values did not reach below values ruled by TCO (Tjatemannens Central Organization, Swedish Confederation of Professional Employees; electric field: 10 V/m and 1 V/m in ELF and VLF, respectively).

  • PDF

The Statistical Technique for Dosimetric Meta-Analysis at in-vivo and in-vitro Papers about Bioeffects of RF Electromagnetic Field (RF 전자기장 생체 영향 연구 문헌에서 노출량 메타분석을 위한 통계적 기법)

  • Choi, Sung-Ho;Kim, Nam
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.12
    • /
    • pp.1311-1320
    • /
    • 2003
  • This paper proposed the estimating method of electromagnetic dosimetric reliability at in-vivo and in-vitro experiments. For more accurate consequences of these researches, we have tried to find out any correlations among output power, power density and specific absorption rate(SAR) with the results of in-vivo, in-vitro tests and SAR reports of cellular phone and PDA. In the case of in-vivo tests, the power density has close statistical correlations with SAR value and in the event of in-vitro tests, the output power has considerable statistical correlations with SAR containing duty factor. We analysed the coefficient of determination to estimate the dosimeoic uncertainty. If we use this method before evaluating techniques of measurement and analysis at both in-vivo and in-vitro experiments, we will conduct more accurate reliability test.

Electromagnetic Interactions between a Cellular Phone and the Human Body and Synthesis of a Bone-Equivalent Material (휴대폰 전자파와 인체의 상호 영향 및 뼈 유사 물질 합성 연구)

  • 윤용섭;김인광;전중창;박위상
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.2
    • /
    • pp.277-290
    • /
    • 1999
  • A simulation using the finite-difference time-domain method to analyze the electromagnetic interactions between a cellular phone and the human body was conducted, and a synthesis of a bone-equivalent material to make a human head phantom was performed. A test model of the cellular phone was fabricated to measure its reflection coefficient and radiation pattern in the free space. Various effects of the human body on the characteristics of the phone, such as input impedance, reflection coefficient, radiation pattern, and radiation efficiency are analyzed as the distance between the head and the phone antenna varies. When the phone was operated close to the head, the resonant frequency of the antenna decreased by up to 12%. With the output power of 0.6W, as long as the distance was larger than 30mm, the 1-g averaged peak SAR was below the ANSI/IEEE safety guideline, 1.6 W/kg. To synthesize the bone-equivalent material, an epoxy with hardener and a graphite powder were used as basis ingredients, and a small amount of a conducting epoxy was added to control the conductivity of the material. A material having a relative permittivity of 18.04 and a conductivity of 0.347, which are close to those of the bone at 850 MHz, was synthesized.

  • PDF

A Study on the Effects of Various Portable Wireless Communication Equipments on the Medical Equipments (각종 휴대용 무선 통신기기가 의료기기에 미치는 영향에 관한 연구)

  • 배한길;김종헌
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.3
    • /
    • pp.392-400
    • /
    • 1999
  • In this paper, the electromagnetic immunity of electronic medical equipments was tested by employing a standard test method for medical equipments. In addition, the electromagnetic interference to the medical equipments caused by four different types of mobile phones such as portable transceiver, analog, digital, and PCS cellular phones, have been studied. In this study, 16 medical equipments of 11 different types were investigated. There are a patient monitor, an infusion pump, a neonatal incubator and so on. In the case of the EMS test, the interferences were detected for seven medical equipments of four different types(53.3%) such as the patient monitor. For the two portable transceivers, 12 medical equipments of eight different models (75%) were affected. All medical equipments were satisfied with electromagnetic immunity by analog, digital and PCS cellular phones. The experiment results show that the malfunction of the electronic medical equipments is dependent on the frequency range and the electric field strength of the mobile phones.

  • PDF

Measurement of Electromagnetic Wave for the Selection of Certification Test Space at GSM Band (GSM 대역용 휴대전화 인증 시험 공간 확보를 위한 전파 환경 측정)

  • Park, Chul-Keun;Min, Kyeong-Sik
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.9
    • /
    • pp.1030-1038
    • /
    • 2007
  • This paper presents the measurement results of strength of electromagnetic wave for GSM-900/GSM-1800 band which is used in Europe. The Giryong village and Sosan field are selected as candidate regions according to the measurement results in Gijang-gun, Busan. The vertical polarizations is about 12 dBm higher than horizontal polarization at two candidate places, and it is measured 25 dBm lower than urban. The maximum value of measured strength of vertical polarizations in the cellular/GSM-900 bands are -65 dBm at Giryong village and -69 dBm at Sosan field, respectively. The maximum value of measured results of PCS/GSM-1800 bands are -90.5 dBm at Giryong village and -85 dBm at Sosan field, respectively, We confirm that the receiving strength of electromagnetic wave are very weak below -65 dBm at two candidate places and the signals of GSM frequency bands not affect to conversional system, then it is considered as a suitable place for GSM mobile field test.

Broadband Double-Cone Antennas for Measuring Partial Discharge (부분방전 측정용 이중 원추형 광대역 안테나)

  • Jang, Seung-Hoon;Choi, Beom-jin;Lim, Dong-Young;Kim, Ki-Chai
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.12
    • /
    • pp.1050-1057
    • /
    • 2015
  • This paper presents the characteristics of broadband double-cone antennas. The antenna is used to measure electromagnetic fields(2~5 GHz) radiated from a primary or a secondary electrode of a pole-transformer when partial discharge occurs inside the pole-transformer. The theoretical analysis is conducted using commercial software based on a finite difference time domain(FDTD) method. The parameters are a radius, and a height of the broadband double-cone antennas, and the number of posts on a ground plane. This paper examines influences of structural parameters of the broadband double-cone antennas on return loss. The results show that a condition for an optimum structure of broadband double-cone antennas exists. It also shows that the broadband double-cone antennas have radiation patterns similar to those of a dipole antenna. Therefore the broadband double-cone antennas are appropriate for the measurement of radiated electromagnetic fields from the pole-transformer. To verify the theoretical analysis, computed results are compared to experimental results.

Electromagnetic Interference Shielding Effectiveness and Mechanical Properties of MWCNT-reinforced Polypropylene Nanocomposites (다중벽 탄소나노튜브강화 폴리프로필렌 나노복합재료의 전자파 차폐효과 및 기계적 특성)

  • Yim, Yoon-Ji;Seo, Min-Kang;Kim, Hak-Yong;Park, Soo-Jin
    • Polymer(Korea)
    • /
    • v.36 no.4
    • /
    • pp.494-499
    • /
    • 2012
  • In this work, the effect of multi-walled carbon nanotube (MWCNT) on electromagnetic interference shielding effectiveness (EMI SE) and mechanical properties of MWCNT-reinforced polypropylene (PP) nanocomposites were investigated with varying MWCNT content from 1 to 10 wt%. Electric resistance was tested using a 4-point-probe electric resistivity tester. The EMI SE of the nanocomposites was evaluated by means of the reflection and adsorption methods. The mechanical properties of the nanocomposites were studied through the critical stress intensity factor ($K_{IC}$) measurement. The morphologies were observed by scanning electron microscopy (SEM). From the results, it was found that the EMI SE was enhanced with increasing MWCNT content, which played a key factor to determine the EMI SE. The $K_{IC}$ value was increased with increasing MWCNT content, whereas the value decreased above 5 wt% MWCNT content. This was probably considered that the MWCNT entangled with each other in PP due to an excess of MWCNT.

Analysis of Current Density Distribution and In Vitro Exposur System fot ELF Exposed Cell Experiments (ELF 전자파 피폭 세포실험을 위한 배양기의 전류밀도 분포 해석 및 In Vitro 노출장치 설계)

  • 김대근;정재승;안재목
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.1
    • /
    • pp.84-91
    • /
    • 2001
  • In in vitro cell experiments for the biological assessment of electromagnetic (EM) field, exposure system (ES) must be analyzed in terms of current density (J) and induced electric field intensity (E). Although in uniform B field, E and J in the sample medium are not distributed uniformly because of conductivity in sample dish. Thus, the precise estimation for E and J induced by uniform ELF within sample media is very important keys for successful in in vitro experiments. In this paper, we designed in vitro ELF ES with electromagnetic analysis using MATLAB simulator. Then we calculated from the measured B field to verify induced E & J distribution for random locations of cells within media in two cases of samples existence or not. ES with B field ranging from 0 to 20G consists of Helmholz coil and current generator based on the microprocessor. Also, we developed ELFES for each B field generation as uniform and non-uniform modes.

  • PDF

Analysis of E-polarized Plane Wave Scattering by a Tapered Resistive Strip Grating in a Grounded Double Dielectric Layer (접지된 2중 유전체 사이의 저항 띠 격자 구조에 의한 E-분극 전자파 산란 해석)

  • Tchoi, Young-Sun;Yang, Seung-In
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.6 s.121
    • /
    • pp.656-663
    • /
    • 2007
  • In this paper, when a E-polarized plane wave is incident on the grating consisting of tapered resistive strips, electromagnetic scattering is analyzed using the method of moments(MoM). The induced current density of each resistive strip in a grounded double dielectric layer is expected to blow up at both edges. To satisfy this, the induced surface current density is expanded in a series of Chebyshev polynomials of the second kind. The scattered electromagnetic fields are expanded in a series of Floquet mode functions. The boundary conditions are applied to obtain the unknown current coefficients. According to the variation of the involving parameters such as strip width and spacing and angle of the incident field, numerical simulations are performed by applying the Fourier-Galerkin moment method. The numerical results of the normalized reflected power for resistive strips case for several resistivities are obtained.