• Title/Summary/Keyword: 전원 관리 시스템

Search Result 275, Processing Time 0.033 seconds

The Key Management System using the Secret Sharing Scheme Applicable to Smart Card (스마트 카드에 적용 가능한 비밀분산법을 이용한 키 관리 시스템)

  • Son, Young-Seol;Lee, Dong-Hoon
    • The KIPS Transactions:PartC
    • /
    • v.11C no.5
    • /
    • pp.585-594
    • /
    • 2004
  • When several service providers want to work together with only one master key, they need to properly distribute the key to participants who come in for the co-work business and then securely manage the distributed keys. This paper describes the system that can efficiently and securely manage the master key on the basis of the secret sharing scheme that can reconstruct original secret information as the necessity of reconstructing original secret arises. The proposed system can distribute secret information to several groups and also redistribute the secret to subgroup in proportion to the participant's security level using smart card-based (t, t)-(k, n)-threshold secret scheme for securely keeping secret information and authentication of participant's identification.

High safety battery management system of DC power source for hybrid vessel (하이브리드 선박 직류전원용 고 안전 BMS)

  • Choi, Jung-Leyl;Lee, Sung-Geun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.7
    • /
    • pp.635-641
    • /
    • 2016
  • In order to drive a hybrid propulsion device which combines an engine and an electric propulsion unit, battery packs that contain dozens of unit cells consisting of a lithium-based battery are used to maintain the power source. Therefore, it is necessary to more strictly manage a number of battery cells at any given time. In order to manage battery cells, generally voltage, current, and temperature data under load condition are monitored from a personal computer. Other important elements required to analyze the condition of the battery are the internal resistances that are used to judge its state-of-health (SOH) and the open-circuit voltage (OCV) that is used to check the battery charging state. However, in principle, the internal resistances cannot be measured during operation because the parallel equivalent circuit is composed of internal loss resistances and capacitance. In most energy storage systems, battery management system (BMS) operations are carried out by using data such as voltage, current, and temperature. However, during operation, in the case of unexpected battery cell failure, the output voltage of the power supply can be changed and propulsion of the hybrid vehicle and vessel can be difficult. This paper covers the implementation of a high safety battery management system (HSBMS) that can estimate the OCV while the device is being driven. If a battery cell fails unexpectedly, a DC power supply with lithium iron phosphate can keep providing the load with a constant output voltage using the remainder of the batteries, and it is also possible to estimate the internal resistance.

Ringer's solution detector and transceiver design for efficient manage of patient (효율적인 환자관리를 위한 링거액 감지기 및 송수신기 설계)

  • Song, Je-Ho;Lee, In-Sang;Lee, You-Yub
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.9
    • /
    • pp.45-50
    • /
    • 2016
  • This paper reports a Ringer's solution detector and transceiver design for the efficient management of patients. The ringer's solution detection and transceiver consisted of the main control part, ringer's solution detection part, display and warning light part, wireless transceiver, and power supply part. The light receiving part of the ringer's solution detection part employed TSL260R-LF photodiode; light permeating part, Water-Clear type LED; and wireless transceiver part, the RF wireless data transceiver module, NR-FPCX. As a result of this Ringer's solution detector and transceiver design that can manage the patient efficiently, it was found that when the ringer's solution was detected by the double photodiode, the operating frequency was 11.95kHz; when it was not detected, the number was 9.6kHz. In the ringer's solution receiver, when the ringer's solution was detected, the number was 0. The corresponding unique RF code was displayed when not detected. The power used in the ringer's solution detection part was converted to the Sleep mode to operate under battery save mode. The ringer's solution transceiver can exchange wireless communication approximately within a 700m radius.

Valve monitoring system design and implementation using an infrared sensor and ZigBee (Zigbee와 적외선 센서를 활용한 밸브 개폐 모니터링 시스템 설계 및 구현)

  • Sim, Hyun;Oh, Jae-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.1
    • /
    • pp.73-80
    • /
    • 2015
  • The valve device is installed in hazardous areas, such as a chemical plant explosion has been sealed with fire protection device to prevent the risk of explosion. In this paper, due to the explosion-proof devices using external power the device can not be used in infrared sensors and Zigbee sensor valve device by measuring the open degree of valve opening and closing of the danger zone to check whether. Valve opening and closing operation log screen time, we propose a low-power operation monitoring system administrators to manage and control the plant. Develop power control relay board apply an improved algorithm to apply the asynchronous LPL power management. The plant monitoring system and explosion-proof valve opening and closing the valve system with the intelligent device designed and implemented and tested it.

Development of Integrated TCU for Multimedia Communication Devices Control (멀티미디어 통신기기 제어를 위한 통합 TCU 개발)

  • Lim, Yangmi;Kang, Namhi
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.3
    • /
    • pp.1-6
    • /
    • 2014
  • Companies almost don't use an integrated control system using expensive network system in multimedia like TV and DID, despite IP-Broadcasting and communication equipment have expanded rapidly. The proposed integrated TCU(terminal control unit) is a control device that supports TV power On/Off check and remote control, power control reservation function, TV channel change, a variety of interface supports of input/output AC power & Lan port, RS-232C and IR using existing IP network after there is installed the Wake-on -Lan in the set-top box. The TCU can control and monitor 24 hours unlike existing low-cost control system RF method. In existing control equipment markets without expandability and low price, the TCU development including 24 hours monitoring and automatic control functions is expected to secure a wide range of companies.

Measurement of Flow Discharges in the Small-sized Rivers using the Wireless Image Acquisition System (무선영상취득시스템에 의한 홍수시 소하천의 유량 측정)

  • Yu, Kwonkyu;Lee, Nam-joo;Kang, Taeuk
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.62-62
    • /
    • 2018
  • 무선영상취득시스템(WIA 시스템, Wireless Image Acquisition System)은 라즈베리 파이에 전용 카메라와 WiFi 모듈을 장착하여, 하천의 영상을 실시간으로 촬영하여 무선으로 서버로 전송하는 시스템이다. 이 시스템이 갖는 가장 큰 이점은 시스템을 구성하는 비용이 매우 저렴하다는 점이다. 라즈베리 본체와 카메라 모듈, WiFi 모듈 모두 매우 저렴하고, 또 사용하는 전력이 작아서 상용 전원이 아닌 태양광 발전이나 배터리 등을 이용할 수 있다. 따라서 비용과 장소에 구애받지 않고 손쉽게 어디든지 설치하여 하천의 상시 감시나 계측에 활용할 수 있다. 또한, 상용 전원을 이용하지 않아도 되기 때문에, 산간벽지나 오지 등의 소하천 관리에도 적합하다. 본 연구에서는 이 WIA 시스템을 경상남도 김해시의 대청천에 적용하여 홍수 시 하천의 수표면을 촬영하고, 촬영된 동영상을 분석하여 수위와 유속을 동시에 계측하여 유량을 산정하였다. 라즈베리 파이에 $640{\times}480$ 화소의 카메라를 장착하여 10분 간격으로 10초간의 동영상을 촬영하고, 이를 WiFi 모듈을 이용하여 무선으로 서버로 전송한다. 전송된 동영상을 분석하기 전에 설치 지점의 3차원 좌표 변환 자료와 횡단면 좌표를 입력하여 대상 지점의 측정 매개변수를 설정한다. 즉, 이들 자료에서 영상 내의 표정점과 측정선을 설정해 둔다. 그 다음, 전송된 동영상을 시공간 영상으로 만들어 수위를 분석한다. 비슷한 방법으로 동영상에서 유속을 분석하고, 분석된 수위와 유속, 그리고 미리 설정된 횡단면 좌표를 이용하여 유량을 산정해 낸다. 설치된 WIA 시스템을 실제로 운용하여, 2017년 9월 11일의 06:10~19:00의 호우 사상 전체를 분석하였다. 10분 간격으로 촬영된 10초간 동영상 중에서 적절한 분석이 가능한 영상 77개에서 수위와 유속을 분석한 결과, 최대 수위는 0.746 m(간이수위표 기준), 최대 유속은 0.962 m/s, 최대 유량은 $12.977m^3/s$에 이르렀다. 지점 특성상 다른 유속계를 이용한 검증은 사실상 불가능하였다. 또, 하폭이 넓어서 일출 전과 일몰 후의 촬영 자료는 분석이 어려운 점이 있다. 이러한 기술적 문제들을 보완하면, WIA 시스템을 이용한 소하천의 수위와 유속 측정 시스템은 경제성이고 효율이 높은 관측시스템으로 유망할 것으로 기대된다.

  • PDF

Improving of the performance with Wireless Water Level Control by using the Full-Duplex Communication Module (양방향 통신을 이용한 무선수위제어기의 성능개선)

  • Yang, Si-Chang;Moon, Chae-Joo;Chang, Young-Hak;Chung, Hae-Duck;Kim, Eui-Sun
    • Proceedings of the KIEE Conference
    • /
    • 2004.10a
    • /
    • pp.157-159
    • /
    • 2004
  • 기존의 수위 제어기는 단 방향 무선 통신을 이용함으로써 오류가 발생한 정보의 수신 시에 정정 능력이 없었다. 그리고 대부분의 관정이 산간 오지에 설치됨으로써 태양전지와 보조 배터리를 전원으로 사용하기 때문에 소모 전력의 절감이 큰 과제였다 또한 송신기와 수신기의 채널 변경 시에는 전문가의 도움을 받아야만 가능하였다. 본 연구에서는 수위 제어기에 마이크로 컨트롤러를 채용하고 양방향 통신 방식을 이용함으로써 잘못 수신된 정보를 정정할 수 있도록 하고, 전력 소모가 많은 송신기의 전원을 관리하며, 일반 사용자도 DIP 스위치를 이용하여 채널을 변경할 수 있는 수위제어 시스템을 구현하고자 하였다.

  • PDF

A Study on Energy Harvesting-based Low-Power IoT Sensor Node for Harbor Structures Maintenance (항만 구조물 유지관리를 위한 자가발전기반 저전력 IoT 센서 노드에 관한 연구)

  • 박철;김영석;이승현
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2022.10a
    • /
    • pp.427-428
    • /
    • 2022
  • 최근 대규모 항만 건설 및 기존 부두 리모델링과 같은 해안 공간 구조물 확충사업이 활발하게 진행되고 있으며 항만 구조물 거동 장기계측을 위한 센서에 대한 관심도 높아지고 있다. 기존의 항만에 적용한 전기식 센서들은 수개월 정도 단기간의 구조물 거동 측정은 가능하지만 수년 이상의 장기계측 시 염수분에 의한 부식 및 내구성에 취약하기 때문에 원활한 측정에 한계점이 있고 센서 설치를 위한 항만 외곽지역 구조물과 육상전원공급설비 배전반 사이의 거리로 인하여 긴 연장의 횡단로 가설전선 보호대 등을 설치해야 하는 어려움이 있다. 따라서, 본 연구에서는 항만 구조물 거동 장기계측을 위해 기존 전기식 센서들의 부식문제점을 파악하여 해수용 4종 센서 IoT 모듈 패키징을 설계하고 외부 전원공급 방해 영향을 최소화한 태양광 발전을 적용한 항만 구조물 거동 계측 시스템을 제안하였다.

  • PDF

A Power Supply Module with Load Sharing and Redundancy (부하분담 및 리던던시 기능을 갖는 모듈전원 개발)

  • Heo, Min-Ho;Lee, Tae-Won;Lee, Se-Ho;Park, Sung-Jun
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.304-305
    • /
    • 2011
  • 정보화 사회로 진입함에 따라 전자화 된 정보의 저장 및 관리는 매우 중요한 사안으로 부각되고 있으며 모든 통신기기 및 전산시스템은 365일 가동이 보장되어야 하므로 여러 대의 전원을 병렬 운전하여 신뢰성을 높이고 용량을 증대시키는 방안이 연구되고 있다. 특히, 신뢰성이 요구되는 분야에서는 리던던시(Redundancy) 개념이 중요하게 되어 병렬 운전의 도입이 확산 되고 있다. 현재 새로운 전력 구조는 절연된 컨버터의 평균 전력량을 다운시켜 다수의 전력변환기를 병렬운전 시키는 방향으로 변하고 있으며, 이는 전력변환기의 신뢰성을 증가시키고 예비기기에 대한 부담을 감소시키는 큰 장점을 갖고 있다. 최근에는 이더넷 라이터를 이용하여 부하분담(Load Sharing) 및 핫스왑(Hot-swap)기능을 DC/DC 컨버터에 내장하고 있는 추세이다. 본 연구에서는 7[kW]급 지능형 DC 모듈전원 제어기술 개발에 초점을 두고 최적의 부하분담을 갖는 고성능 전류 제어 알고리즘을 소개하고자 한다.

  • PDF

Distributed Load Flow Algorithm for Power Distribution System under Strategic Business Unit (독립사업부제를 대비한 분산형 배전용 조류계산 알고리즘)

  • Kim, D.H.;Norbekov, Nodir;Lee, H.C.;Yoon, Y.T.;Lee, S.S.;Lee, S.K.
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.33-35
    • /
    • 2006
  • 배전 독립사업부제 도입 및 분산전원의 출현으로 배전계통은 계획 및 운영에 있어서도 변화가 일어 날 것이다. 예로, 기존의 방사상 구조의 배전 계통은 분산 전원의 출현으로 부분적인 그물망 구조로 변형될 수 있으며, 사업 구역이나 사업 지역으로 나누어진 배전계통에서는 서로 다른 관리 체제 하에서 운영이 필요하기 때문에 각 배전회사간의 정보 공유 문제가 발생할 수도 있다. 이러한 문제를 해결하기 위해 분화된 배전 계통의 특성을 고려하여 송전계통과 같이 전체 시스템에 대해 조류 계산하지 않고 배전 계통을 몇 개의 영역으로 나누고 다른 영역과의 경계 정보만을 이용하여 자신의 영역에 대한 조류 계산을 수행하는 알고리즘을 제안하였다. 이런 특성을 최대한 반영한 각 영역의 조류 계산은 분산 전원의 투입으로 인한 양방향 조류가 발생하게 되므로 그물망 구조로 된 구역과 기존의 방사상 구조로 된 영역으로 구분할 수 있다. 본 논문에서는 구역 특성에 맞고 배전 계통에 적용 가능한 알고리즘으로 먼저 분리 구역별 조류 계산을 수행한 후 그 다음 경계치 교환으로 배전 계통 전체의 조류 계산을 수행하는 알고리즘을 제안한다. 즉 방사상 구조 영역에서는 back/forward sweep 방법으로 수행하고 그물망 구조 영역에서는 Full Newton-Raphson 방법으로 구분하여 영역의 특성에 맞게 수행하였다.

  • PDF