• Title/Summary/Keyword: 전원제어장치

Search Result 600, Processing Time 0.031 seconds

The research of Automatic Classification of Products Using Smart Plug by Artificial Intelligence Technique (인공지능 기법으로 스마트 플러그를 이용한 제품 자동분류에 관한 연구)

  • Son, Chang-Woo;Lee, Sang-Bae
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.6
    • /
    • pp.842-848
    • /
    • 2018
  • The Smart plug is a device that connects between the outlet and the product at home, and it is an IoT type device that can drive energy saving and transmit information to the outside by power on / off control function and power measurement function. In this case, a smart plug that incorporates deep learning of intelligence technology that allows people to learn how to think about a computer, automatically classifies a product as it operates, and automatically tests the operating status of the washing machine by using input AC current pattern. Through this study, even if the product does not function as IoT, it can classify product type and operation state by smart plug connection alone, so we can draw a new paradigm of life pattern and energy saving in one family.

Dynamic Performance of HVDC according to Excitation System Characteristics of Synchronous Compensator in a Weak AC System (약한 계통에서 동기조상기의 여자 시스템에 따른 HVDC 시스템의 과도 성능 분석)

  • 김찬기
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.4
    • /
    • pp.318-326
    • /
    • 2000
  • This paper analyses with the dynamic performance of HVDC System connected to a weak AC system for varying exciter characteristics of synchronous machines connected at the converter bus. Conventionally capacitors are used to supply reactive power requirement at a strong converter bus. However the installation and synchronous machine is essential in a isolated weak network to re-start after a shutdown of HVDC and to increase strength. The dynamic performance of a synchronous machine depends on the characteristics depends on its exciter characteristics. In this paper, several excites types are used to investigate their effect on the dynamic performance of the HVDC system and modifications to standard exciter topogical are suggested to mitigate observed problems.

  • PDF

접착 테이프형 액체 누설 감지 박막 센서

  • Han, Guk-Hui;Kim, Yun-Jung;Jeong, Jong-Yun;Lee, Min-Gyeong;Gang, Han-Rim;Kim, Jung-Gil;Lee, Won-Yeong;Yu, Hong-Geun;Jo, Gwang-Seop
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.355-355
    • /
    • 2012
  • 액체 누설을 감지하는 센서를 개발하였다. 이 센서는 경보 장치를 포함하며 접착 테이프형태의 박막 센서이다. 센서는 총 4개의 층으로 구성되어 있다. 각 층의 명칭은 접착제층, 베이스 필름층, 기판 필름층, 보호 필름층이다. 감지선의 사용량을 최소화하여 기판 필름층 위에는 총 4개의 선이 있다. 전도선 3개와 저항선 1개이다. 4개의 선들은 기판 필름층에 전도성 은나노 잉크를 그라비어인쇄기를 이용하여 센싱 회로를 인쇄하였으며 이 기술의 이 센서의 가장 큰 특징이다. 누수 발생 시에 저항선과 전도선에 액체가 접촉되어 회로 상에 교차하는 내부저항의 전압 변화를 모니터링하여 누수를 감지하는 방식의 센서이다. 감지선에 전원을 양방향으로 번갈아 인가함으로써 수분의 저항 값 증가 및 양극화를 방지하였다. 그로 인해 기존의 센서에 비해 좀 더 안정적이고 정확한 감지를 할 수 있다. 설치 후 센서가 마모되거나 손상될 시 간단하게 재설치 할 수 있다는 장점도 있다. 액체 누설 후에도 별도의 건조시간이 필요하지 않다. 표면에 남아있는 액체를 제거하여 즉시 재사용하는 것이 가능하다. 액체누설 감지 시스템은 액체누설 감지 필름 센서를 포함하며, 표시부와 경고음 발생부 등 전체를 제어한다. 표시부의 누설 위치 표시 단위는 미터(m)이며 최소 0.1 m 단위까지 표시한다. 이 액체누설 감지 시스템을 이용하여 누설 위치 감지 실험 및 액체별 누설 위치 감지 실험을 진행하였다.

  • PDF

A Study on Reactor Capacitance Estimation Algorithm and 5kW Plasma Power Supply Design for Linear Output Control of Wide Range (넓은 범위의 선형 출력 제어를 위한 5kW 플라즈마 전원장치 설계 및 반응기 커패시턴스 추정 알고리즘의 관한 연구)

  • Noh, Hyun-Kyu;Lee, Jun-Young;Kim, Min-Jea
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.6
    • /
    • pp.514-524
    • /
    • 2016
  • This work suggests a study on 5 kW plasma power supply design and reactor capacitance estimation algorithm for a wide range of linear output control to operate a plasma reactor. The suggested study is designed to use a two-stage circuit and control the full-bridge circuit of the two-stage circuit using the buck converter output voltage of the single-stage circuit. The switching frequency of the full-bridge circuit is designed to operate through high-frequency switching and obtain maximum output using LC parallel resonance. Soft switching technique(ZVS) is used to reduce the loss caused by high-frequency switching, and duty control of the buck converter is applied to control a wide range of linear output. The internal capacitance of the reactor cannot easily be extracted, and thus, the reactor cannot be operated in an optimized resonant state. To address this issue, this work designs the internal capacitance of the reactor such that estimations can be performed with the developed reactor capacitance estimation algorithm applied to the internal capacitance of the reactor. A 5 kW plasma power supply is designed for a wide range of linear output control, and the validity of the study on the reactor capacitance estimation algorithm is verified.

Doors open and close during regenerative energy harvester developed (자동문 개폐 시 회생에너지 하베스트 개발)

  • Park, Won-hyeon;Kim, Min;Jeong, Jae-hoon;Lee, Dong-heon;Byun, Gi-sik;Kim, Gwan-hyung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.257-258
    • /
    • 2015
  • Korean power consumption of the electrical supply problems due to excess demand is repeated every year, the interest in energy increasing social and personal cost has been subject to the number of ways to reduce this cost increases. Automatic doors and automatic door installation market is increasing every year and frequently, when used in general commercial and communal porch consumption based on average 300 times a day power is 70[W] degree is a monthly average usage is about 50.4[KW]. The level can not ignore the power consumption due to switching frequency is large. In this paper, by converting the energy to be discarded in the automatic doors to the inverter and the regenerative energy and to develop control systems for power regeneration to reduce the power consumption by utilizing automatic contact auxiliary power.

  • PDF

Self Oscillation DC/DC Converter with High Voltage Step Up Ratio (고전압 변환비의 자려 발진 DC/DC Converter)

  • Jung, Yong-Joon;Han, Sang-Kyoo;Hong, Sung-Soo;Roh, Chung-Wook
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.3
    • /
    • pp.220-227
    • /
    • 2009
  • A self oscillation DC/DC converter which has a very desirable characteristics of the high input-output voltage conversion ratio for high voltage DC power supply applications is proposed in this paper. The proposed converter is composed of one power switch, one inductor, several capacitors and diodes. Compared with conventional high-voltage DC/DC converters, it performs the high- voltage power conversion using the inductor instead of the bulky step-up transformer. Therefore, it can reduce the size of magnetic device and save the cost. Moreover, since it needs no control IC by using self oscillation circuit and has lower voltage stress on output diodes, it features a lower cost, simpler structure and more improved performance. Finally, a comparative analysis and experimental results are presented to show the validity of the proposed converter.

Output characteristics of ac excited $CO_2$ laser as a adjusting a phase angle and frequency (위상각와 주파수 제어에 따른 상용주파 AC 여기 방식의 펄스형 $CO_2$ 레이저 전원장치 개발에 관한 연구)

  • Chung, Hyun-Ju;Kim, Do-Wan;Lee, Dong-Hoon;Kim, Joong-Mann;Kim, Mee-Je;Cho, Jung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2098-2100
    • /
    • 2000
  • We propose pulsed $CO_2$ laser below 30W by the AC(60Hz) switching control of leakage transformer primary which has some advantage of cost and size compared to a typical pulsed power supply. Pulse repetition rate is adjusted from 5Hz to 60Hz to control laser output. In this laser, a low voltage open loop control for high voltage discharge circuit is employed to avoid the HV sampling or switching and high voltage leakage transformer is used to convert rectified low voltage pulse to high voltage one. A ZCS(Zero Cross Switch) circuit and a PIC one-chip microprocessor are used to control gate signal of SCR precisely. The pulse repetition rate is limited by 60Hz due to the frequency of AC line and a high leakage inductance. The maximum laser output was obtained about 23W at pulse repetition rate of 60Hz, total gas mixture of $CO_{2}/N_{2}$/He = 1/9/15, SCR gate trigger angle 90$^{\circ}$, and total pressure of 18Torr.

  • PDF

Development of Multi-Link Mobile Robot for Rough Road Driving (험로 주행을 위한 다중모듈 로봇의 설계)

  • Paek, Ryu-Gwang;Han, Kyong-Ho;Shin, In-Chul
    • Journal of IKEEE
    • /
    • v.14 no.2
    • /
    • pp.58-63
    • /
    • 2010
  • In this paper, design and implementation of multi-modular robots of similar structure to the arthropods for rock path driving. Each module corresponds to an arthropod joint, which has an independent power supply and control equipment including drive and short-range Zigbee wireless communication that were implemented. On various directions and paths each module has the same driving direction and each module is controlled to operate or not by wireless communication. Depending on path condition, each module calculate the speed and torque and depending on the slope of a rough path, the number of active modules can be changed for the efficient driving on a variety of roads conditions. Experimental driving through rough road model, variable multi-module robot is implemented.

A Study on Evaluation of Power Management IC (전원모듈 PMIC 특성평가에 관한 연구)

  • Lho, Young Hwan
    • Journal of IKEEE
    • /
    • v.20 no.3
    • /
    • pp.260-264
    • /
    • 2016
  • The MAX77846, which is compatible with MAX77826, is a sub-power management IC (PMIC) for the latest Wearable Watch and 3G/4G smart phones. The MAX77846 contains N-MOSFET (N channel Metal-Oxide Semiconductor Field-Effect Transistor), a high-efficiency regulator, and comparator, etc to power up peripherals. The MAX77846 also provides power on/off control logic for complete flexibility and an $I^2C$ (Inter Integrated Circuit) serial interface to program individual regulator output voltages. In this paper, the simplified power macro-model based on MAX77846 is designed to verify the performance of the battery voltage in terms of current and time, and simulated by using of the LTspice. In addition, it is verified how much time can the charged battery capacity for Samsung Galaxy Gear 2 be used to operate a specified function after measuring the currents flowing to carry out the main functions in real time, which will be applicable to design parameters for the advanced power module

Development of an Portable Urine Glucose Monitoring System (휴대용 뇨당 측정 시스템의 개발)

  • 박호동;이경중;윤형로
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.5
    • /
    • pp.397-403
    • /
    • 2002
  • Urine glucose monitoring system is a self-monitoring system that display the glucose level by non-invasive measurement method. In this paper, We developed a noninvasive urine glucose monitoring system that improved defects of urine glucose measurement with a colorimeter method and invasive blood glucose measurement method. This system consist of bio-chemical sensor for urine glucose measurements, signal detecting part, digital and signal analysis part, display part and power supplying part. The developed bio-chemical sensor for the measurement of urine glucose has good reproducibility, convenience of handing and can be mass-produced with cheap price. To evaluate the performance of the developed system, We performed the evaluation of confidence about the detection of glucose level by a comparison between a standard instrument in measuring glucose level and the developed system using standard glucose solutions mixed with urine. Standard error was 2.85282 from the evaluation of confidence based on regression analysis. Also, In analysis of S.D(standard deviation) and C.V(coefficient of validation) that are important parameters to evaluate system using bio-chemical sensor, S.D was 10% which falls under clinically valid value, 15%, and C.V was under 5%. Consequently from the above results, compared to blood glucose measurement, the system performance is satisfactory.