• 제목/요약/키워드: 전류센서

Search Result 984, Processing Time 0.03 seconds

Analog Front-End IC for Automotive Battery Sensor (차량 배터리 센서용 Analog Front-End IC 설계)

  • Yeo, Jae-Jin;Jeong, Bong-Yong;Roh, Jeong-Jin
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.48 no.10
    • /
    • pp.6-14
    • /
    • 2011
  • This paper presents the design of the battery sensor IC for instrumentation of current, voltage using delta-sigma ADC. The proposed circuit consists of programmable gain instrumentation amplifier (PGIA) and second-order discrete-time delta-sigma modulator with 1-bit quantization were fabricated by a 0.25 ${\mu}m$ CMOS technology. Design circuit show that the modulator achieves 82 dB signal-to-noise ratio (SNR) over a 2 kHz signal bandwidth with an oversampling ratio (OSR) of 256 and differential nonlinearity (DNL) of ${\pm}$ 0.3 LSB, integral nonlinearity (INL) of ${\pm}$ 0.5 LSB. Power consumption is 4.5 mW.

Design of a DC-DC Step-Down Converter for LED Backlight of Mobile Devices (휴대기기용 LED 백라이트를 위한 감압형 DC-DC 변환기 설계)

  • Son, Hyun-Sik;Lee, Min-Ji;Park, Won-Kyoung;Song, Han-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.3
    • /
    • pp.1700-1706
    • /
    • 2014
  • In this paper, a step down converter for LED backlight of mobile application has been proposed. The converter which is operated with 4 MHz high switching frequency is capable of reducing mounting area of passive devices consists of a power stage and a control block. Circuit elements of the power stage are inductor, output capacitor, MOS transistors and feedback resistors. The control block consists of pulse width modulator, error amplifier and oscillator etc. Proposed step down converter has been designed and verified using a $0.35{\mu}m$ 1-poly 4-metal BCD process technology. Simulation results show that the output voltage is 1.8 V in 3.7 V input voltage, output current 100 mA which is larger than 25 ~ 50 mA in conventional 500 KHz driven converter when the duty ratio is 0.4.

Investigation of Factors Influencing Methanol Crossover in Direct Methanol Fuel Cell (직접메탄올연료전지에서 메탄올 크로스오버에 미치는 인자 연구)

  • Hyun, Min-Soo;Kim, Sang-Kyung;Lim, Seong-Yop;Lee, Byung-Rock;Peck, Dong-Hyun;Jung, Doo-Hwan
    • Journal of the Korean Electrochemical Society
    • /
    • v.11 no.1
    • /
    • pp.6-10
    • /
    • 2008
  • The amount of methanol crossover was measured with changing the operating condition by using a liquid methanol concentration sensor. Appropriate operating condition was discussed in terms of methanol crossover. Mechanism of methanol crossover was classified into three items which are diffusion, convection and electro-osmosis. Contribution of each mechanism to methanol crossover and the effect of operating condition were analyzed with varying methanol concentration, pressure difference between anode and cathode, current, temperature, and stoichiometry of anode fuel. Among the three mechanisms diffusion affected mostly and electro-osmosis effect was observed only under high methanol concentration.

Current Characteristics of a Flow Injection Type Enzyme-Sensor as the Variables of a Buffer Velocity, an Enzyme-Substrate Reaction and an Electrode for the Control of a Fermentation Process (완충용액유속, 효소.기질 반응 및 전극봉 요인에 따른 발효공정 제어용 흐름주입식 효소센서의 전류값 특성)

  • Song, Dae-Bin;Jung, Hyo-Seok;Kim, Sung-Tae
    • Journal of Biosystems Engineering
    • /
    • v.32 no.6
    • /
    • pp.455-461
    • /
    • 2007
  • The electric current of a flow injection type enzyme-sensor was measured to confirm the stable operating conditions of the sensor. The current of the sensor was decreased as the buffer solution velocity increased. Under the limitation of the cycle time to be below 10 minutes, the effective ranges of the buffer solution velocity were suggested $0.10{\sim}0.26$, $0.12{\sim}0.24$, $0.1{\sim}0.25$ and $0.05{\sim}0.10\;cm/s$ of 1.0, 1.4, 2.4 and 3.4 mm of the electrode diameters, respectively. As the reaction time of the enzyme and the substrate was increased, the current was decreased because of the dilution between the sample and buffer solution. Therefore, it could be recommended that the reaction time was able to be selected as shortly as possible in consideration of the total cycle time. As the result of the experiments using a different volume ratio of the enzyme to substrate, it was concluded that the substrate had to be mixed with the same amount of the enzyme. The current have increased remarkably in proportion to the electrode diameter under 0.1 cm/s of the buffer solution velocity but there was no difference over 0.1 cm/s of the buffer solution velocity. The cross type arrangement of the electrode was highly suggested for application and machining of the sensor.

An Example of Internal Wave Detection in North Coastal Waters of Cheju Island Using a SAR Image (SAR를 이용한 제주도 북부해역에서의 내부파 관측예)

  • Kim, Tae-Rim;Won, Joong-Sun
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.4 no.1
    • /
    • pp.18-24
    • /
    • 1999
  • The satellite image acquired by RADARSAT SAR on August 15, 1996 reveals internal waves in north coastal waters of Cheju Island. It is indicated from the image data, the tidal elevation data, and the bottom topography data, the internal waves seem to be generated by interaction between shallow bottom and tidal currents travelling in the stratified water in the summer time during the tidal changeovers from ebb to flood. The internal waves generated in such condition show patterns of trains of solitons. Probable amplitude of observed solitons is calculated using estimation of the soliton wave length from SAR image data and K-dV equation. Detection of the internal waves is very significant not only to military strategist for underwater maneuvers such as operation of submarines, but also to physical and biological oceanographers. Temporal and spatial variation of the internal waves are needed to be measured by simultaneous in-situ field study together with SAR to examine the nature of these internal waves.

  • PDF

Crystal Growth Sensor Development of II-VI Compound Semiconductor : CdS (II-VI족 화합물 반도체의 결정성장 및 센서 개발에 관한 연구)

  • D.I. Yang;Y.J. Shin;S.Y. Lim;Y.D. Choi
    • Journal of the Korean Vacuum Society
    • /
    • v.1 no.1
    • /
    • pp.126-133
    • /
    • 1992
  • This study deals with the crystal growth and the optical characteristics of CdS thin films activatedby silver. CdS:Ag thin films were deposited by using an electron beam evaporation(EBE) technique in vacuumof 1.5X 10-'torr, voltage of 4 kV, current of 2.5 mA and substrate temperature of 250$^{\circ}$C CdS:Ag photoconductivefilms prepared by EBE method show high photoconductivity after annealing at about 550"c for 0.5 h in air andAr gas.The grain size of CdS:Ag thin films annealed in Ar atmosphere (1 atm) was grown over 1 ym and the thicknessof the films is 4-5 pm. The analysis of X-ray diffraction patterns shows that the crystal structures are hexagonal.The diffraction line by (00.2) plane can only be observed, indicating that c-axis of hexagonal grows preferentiallyperpendicular to the substrate. The profiles of photoluminescence spectra of CdS:Ag films show Gaussian typecurves at room temperature, the maximum peak spectral sensitivity of CdS:Ag is located at the wavelength of520 nm.We annealed CdS:Ag thin films in air and Ar vapor in order to make the CdS photoconductors having theintensive photocurrent, the broad distribution of the photocurrent spectrum and the large value of the ratioof the photocurrent (pc) to the dark current(dc). We found that CdS:Ag thin films annealed in air atmospherewas the best one.air atmosphere was the best one.

  • PDF

Determination of brightener concentrations in Watt-type Ni Electroplating bath using dilution titration-cyclic voltammetry stripping (DT-CVS) (희석 적정-순환전류전압법을 이용한 와트욕 내부 광택제 농도 모니터링)

  • Choe, Seung-Hoe;Gwon, Yeong-Hwan;Lee, Ju-Yeol;Kim, Man;Park, Yeong-Bae;Lee, Gyu-Hwan
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.30-30
    • /
    • 2018
  • 스마트 도금공장을 구축하기 위해서는 도금액 내부의 화학 물질 농도 변화를 측정할 수 있는 화학 센서 기술이 필수적으로 요구된다. 와트욕은 대표적인 고속 니켈 도금액 중 하나로 기본적으로 황산니켈, 염화니켈, 보릭산의 염과 함께 케리어(type-1 광택제), 광택제(type 2-광택제), 응력 제어제 등의 유기 첨가제로 구성되어 있다. 이러한 유기 첨가제는 전차된 니켈층의 두께 균일도, 조도, 미세 구조, 내부 응력 등 다양한 특성을 제어하며, 정밀한 농도 관리가 필수적으로 요구되나, 분석 기술의 부재로 인하여 지금까지도 대부분의 액관리는 할셀법이나 작업자의 경험에 의존하고 있다. Cyclic voltammetry stripping(CVS) 방법은 전기화학 분석 과정에서 나타나는 첨가제의 가속, 감속 특성 등과 여기에 수반되는 stripping peak의 변화를 이용하여 개별 첨가제의 농도를 측정하는 방법이며, 지금까지 인쇄회로기판의 비아필 공정, 전해 동박 제조, 반도체 배선 등 구리도금 산업 전반에 걸쳐 첨가제 관리에 효과적으로 적용되고 있다. 그러나 수소 발생으로 인한 stripping 효율 문제로 인하여 니켈, 주석, 아연 등 표준 환원 전위가 높은 금속 도금액 내부 첨가제 농도 측정은 아직 어려운 상황이다. 본 연구에서는 이 문제를 극복하기 위해 염소를 과량 첨가한 구리 도금액을 CVS 분석의 base 용액으로 이용하여 니켈 도금액 내부 여러 광택제 (polyetylene glycol(PEG) 계열, thiourea 계열, 2-butyne-1,4-diol 등) 농도를 측정하는 법을 제시하였다. 제시된 방법은 CVS 분석 과정에서 구리-염소 사이의 상호 작용으로 인해 생성되는 3가지 stripping peak의 상대적인 크기 변화가 첨가제 농도에 따라 영향을 받는다는 사실에 기반하였다. 본 연구에서는 여기에 관한 원인에 대해 고찰하였으며, 제시된 방법을 통해 광택제 계열 첨가제 농도 측정을 선택적으로 할 수 있다는 것을 증명하였다.

  • PDF

Demagnetization to Induce Vertical Magnetization in a Military Vessel (함정에 수직자화를 부여하기 위한 탈자)

  • Kim, Young-Hak
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.1109-1112
    • /
    • 2015
  • A milatary ship without degaussing coil has a vertical magnetization to compensate magnetization induced by the vertical magnetic field component of earth magnetic field during demagnetization process. Flash D is very useful to acquire vertical magnetization. However this is hard to predict vertical magnetization. This experiment was investicated on another method, which used the only vertical bias magentic field. The specimens were prepared by thin Zn coated steel sheet with a thickness of 0.15mm. The shapes of 3 specimes was rectangular, triangular and circular cylinders. These shapes were corresponded to the shapes of bow, mid and stern of a vessel. Through FEM analysis, the difference of magnetic signatures for these specimens was recognized and the residual magnetization curve was measured. magnetic field was generated by a solenoid coil and magnetic signature was measured by a magnetic field sensor. A linearity between a vertical bias magnetic field and a vertical manetzation existed and the vertical magnetization of a miltary vessel was predicted by the linearity.

  • PDF

Sensitivity and Rejection Capability of Thermal Asperity Induced by Sub-Micron Contamination Particles (미세 입자에 의한 thermal asperity의 민감도 해석 및 감소 방안)

  • 좌성훈
    • Journal of the Korean Magnetics Society
    • /
    • v.10 no.6
    • /
    • pp.310-317
    • /
    • 2000
  • With use of (G)MR head, thermal asperity (TA) has been a big concern in drive industry. In this study, we investigated several factors of heads and disks which affects the TA sensitivity of the drive. TA experiments were conducted by introducing the particles on the drives using a particle injection chamber. It was found that the slider ABS shape can help to reduce TA or contamination in the head/media interface. However, TA sensitivity of the drive mainly depend on the intrinsic property of (G)MR sensor. GMR head is much less sensitive to TA compared with MR head. However, in case that the same bias current was applied for both of MR and GMR head, TA sensitivity of GMR head became almost identical to that of MR head. Therefore it was found that the bias current is a dominant factor in determining TA sensitivity of the head. TA sensitivity of different types of disks was also studied. The scratch resistance of the carbon overcoat layer is the one of the main factors which influence TA rejection capability of the disks.

  • PDF

A study on the development of constant temperature hot wire type air flow meter for automobiles (자동차용 정온도 열선식 공기유량계의 개발에 관한 연구)

  • 조성권;유정열;고상근;김동성
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.12
    • /
    • pp.2407-2414
    • /
    • 1992
  • Constant temperature hot wire air flow meter for automobiles requires temperature compensation system because hot wire output signal is sensitive to ambient temperature variations as well as fluid velocity. The objectives of the present study are to design an air flow meter circuit which is capable of compensating the hot wire output signal for ambient temperature variations and to investigate the mechanism of such temperature compensation. This circuit is composed of platinum hot wire, platinum resistor, two variable resistors, a constant resistor and a DC-amplifier. In particular, by simply replacing a constant resistor in one of the bridge arms of the conventional circuit with platinum resistor and a variable resistor for the purpose of temperature compensation, the deviation of output signal with respect to ambient temperature variations between 27deg. C 70deg. C could be reduced to less than 2.5% for mass flow rate and to less than 5% for velocity respectively. The mechanism of temperature compensation against ambient temperature variations was explained by means of measuring the heat transfer coefficient with hot wire temperature variations and analyzing and analyzing conventional empirical equations qualitatively.