• Title/Summary/Keyword: 전력 부가 효율

Search Result 827, Processing Time 0.028 seconds

Performance Analysis of Beamforming Satellite System Applying Circular Array Antenna (원형 형상 배열 안테나를 적용한 위성 빔형성 시스템 성능 분석)

  • Kim, Tae-Yun;Hwang, Suk-Seung
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.5
    • /
    • pp.845-852
    • /
    • 2019
  • The main goal of Signal Intelligence (SIGNT) based on a satellite is to collect valid and accurate data without the topographical constraints, but, due to the characteristics of the satellite communication, the collected signals are greatly vulnerable to the influence of interference and jamming signals because their power are very low. Therefore, the high performance techniques of estimating the angle of arrivals (AOAs) of the collected signals and suppressing interference signals are required for collecting various signals on the ground employing the satellite. In addition, the high quality of the transmission beam-forming technique is required for accurately transmitting the collected information to a ground control center. In this paper, we present a beam-forming satellite system based on a circular array antenna, considering the above techniques, and evaluate and analysis the performance of the presented beam-forming system through the computer simulation. The circular array antenna structure is expected to effectively employ for the SIGINT system based on a satellite, because it is suitable to be installed in the satellite.

Dynamic Behavior of Buried Pipelines Constructed by Domestic and USA Specifications (국내 및 미국 시방서에 따라 시공된 지중매설관의 동적거동)

  • Jeon, Sang-Soo;Kim, Jae-Min
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.11 no.1
    • /
    • pp.59-66
    • /
    • 2011
  • Lifeline Damages induced by earthquake loading brings not only a structure damage but the communication problems by the interruption of various energy utilities such as electric power, gas, and water resources. Earthquake loss estimation systems in USA and Japan, called as HAZUS (Hazard in US) and HERAS (Hazards Estimation and Restoration Aid System), respectively, have been established for the purpose of efficient responding to the earthquake hazard. Sufficient damage records are required to establish these systems. However, there are insufficient data set of damage records obtained from previous earthquakes in Korea. In this study, according to the construction specifications of the pipelines in both Korea and USA, the behavior of both ductile and brittle pipelines embedded in dense sand overlying various soils, such as clay, sand, and gravel were examined with respect to the pipeline characteristics under various earthquake loadings. The applicability of pipeline damage prediction used in HAZUS program to Korea has been investigated.

Design of XOR Gate Based on QCA Universal Gate Using Rotated Cell (회전된 셀을 이용한 QCA 유니버셜 게이트 기반의 XOR 게이트 설계)

  • Lee, Jin-Seong;Jeon, Jun-Cheol
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.7 no.3
    • /
    • pp.301-310
    • /
    • 2017
  • Quantum-dot cellular automata(QCA) is an alternative technology for implementing various computation, high performance, and low power consumption digital circuits at nano scale. In this paper, we propose a new universal gate in QCA. By using the universal gate, we propose a novel XOR gate which is reduced time/hardware complexity. The universal gate can be used to construct all other basic logic gates. Meanwhile, the proposed universal gate is designed by basic cells and a rotated cell. The rotated cell of the proposed universal gate is located at the central of 3-input majority gate structure. In this paper, we propose an XOR gate using three universal gates, although more than five 3-input majority gates are used to design an XOR gate using the 3-input majority gate. The proposed XOR gate is superior to the conventional XOR gate in terms of the total area and the consumed clock because the number of gates are reduced.

Development of radar rainfall estimation technique considering the elevation effect for hydropower dam operation (발전용 댐 운영을 위한 고도영향을 고려한 레이더 정량적 강우 추정 기술 개발)

  • Yoon, Seong Sim;Shin, Hongjoon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.69-69
    • /
    • 2020
  • 수자원 확보 및 홍수 대응을 위해서는 정확한 강우정보를 바탕으로 한 효율적인 댐 운영이 필요하다. 그러나 댐이 위치한 지역은 산지지역으로 강우관측소 밀도의 지역적인 편차로 인해 지상 관측 강우자료 활용 시 강우 정보의 정확도 확보에 한계가 있다. 또한, 강우의 시·공간적 변동성 심화로 기존의 강우계만으로는 정확한 강우량 추정이 어려워 이를 홍수기 댐 운영의 기초정보로 활용 시 합리적 댐 운영에 한계가 있다. 댐 운영 시 강우 관측정보는 댐 유입량 산정을 위한 강우-유출해석 모형의 입력 자료로 활용되기 때문에 강우량 자료의 정확도 확보가 무엇보다 중요하나, 현재 댐 운영에 필요한 강우 관측정보로는 지상우량계 자료가 주로 활용되고 있어 이를 보완하고자 일반적으로 강우의 공간분포를 관측할 수 있는 고해상도 레이더 강우 정보가 활용되고 있다. 본 연구에서는 전력생산(발전) 및 용수공급, 홍수조절 기능을 고려하여 운영되고 있는 한국수력원자력(주)의 수력발전용댐(팔당, 의암, 춘천, 화천, 청평, 도암, 괴산, 섬진강, 보성강댐)에 활용할 수 있도록 환경부 합성레이더 자료를 바탕으로 레이더 강우정보를 산출하고, 레이더 강우의 정확도 향상을 위해 고도영향을 고려한 레이더 강우 보정기술을 개발하고자 한다. 적용한 기법은 강우장의 공간적 구조는 레이더 자료로 획득하고, 강우량은 강우계 관측정보를 합성하는 조건부합성기법을 기본으로 하며, 고도 영향을 고려할 수 있도록 강우분포장 생성 시 주변수를 강우로, 이차변수를 고도로 정의한 표준화된 정규공동크리깅을 활용한 기법이다. 본 연구를 통해 산출된 레이더 강우를 댐 유입 측면에서 기존의 보정기법과 비교하여 정확도를 검토하고, 댐 운영에 활용할 수 있도록 유역평균강우량 정보를 산출하고자 한다.

  • PDF

Design of Isolation-Type Matching Network for Underwater Acoustic Piezoelectric Transducer Using Chebyshev Filter Function (체비셰프 필터함수를 이용한 수중 음향 압전 트랜스듀서의 절연형 정합회로 설계)

  • Lee, Jeong-Min;Lee, Byung-Hwa;Baek, Kwang-Ryul
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.6
    • /
    • pp.491-498
    • /
    • 2009
  • This paper presents the design method of an impedance matching network using an isolation transformer and the Chebyshev filter function for the high efficiency and the flat power driving of an underwater acoustic piezoelectric transducer. The proposed impedance matching network is designed for minimizing the reactance component of transducer and having the flat power response in the wide frequency range. We design a low pass filter with ladder-type circuit using the Chebyshev function as standard prototype filter function. In addition, we design the impedance matching network which is suitable for the equivalent circuit of transducer and the turn ratio of transformer through the bandpass frequency transformation. The proposed method is applied to the simulated dummy load of the tonpilz-type transducer operating in the middle frequency range. The simulation results are compared with the measured characteristics and the validity of the proposed method is verified.

Delay time Analysis of Asynchronous RIT Mode MAC in Wi-SUN (Wi-SUN에서 비동기 RIT모드 MAC의 지연시간 분석)

  • Dongwon Kim;Mi-Hee Yoon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.24 no.2
    • /
    • pp.65-70
    • /
    • 2024
  • In recent years, research on smart factory wireless mobile communication technology that wirelessly remotely controls utilities is being actively conducted. The Wi-SUN (Wireless Smart Utility Network) Alliance proposed a Wi-SUN protocol structure suitable for building a platform such as a smart factory as a new wireless communication standardization standard based on EEE802.15.4g/e. It analyzes the performance of the IEEE802.15.4e Receiver Initiated Transmission(RIT) Mode Media Access Control (MAC) in terms of throughput and latency, and looks at considerations for efficient operation. RIT mode shows that as the check interval becomes longer, delay time and throughput decrease. It was shown that as the traffic load increases, if the RIT check interval is shortened, the delay time can be shortened and throughput can be increased. RIT mode has the advantage of low power consumption and has neutral characteristics between IEEE802.15.4 and CSL mode in terms of delay time and throughput.

Economic Welfare Study on Seasonal and Time Period Electricity Pricing (계시별 전력가격에 대한 경제적 후생 연구)

  • Yoo, Young-Hoon;Kim, SungSoo
    • Environmental and Resource Economics Review
    • /
    • v.14 no.2
    • /
    • pp.519-547
    • /
    • 2005
  • The aim of this study is to analysis how economic welfare lost happens within the present korea seasonal and time period electricity pricing system and find out reasonable electricity price system acceptable during the transitional period of korea electricity industry restructuring To analyze economic welfare lost in the electricity industry, in advance seasonal and time periodic 9 demand curves(summer, spring &fall, winter/peak-load time, middle-load time, low-load time) and one market supply curve are made and then using these demand and supply curve, seasonal and time periodic market equilibrium prices is calculated. Finally, comparing these market equilibrium prices with present regulated classified seasonal and time periodic prices, the whole economic welfare lost in the electricity industry is calculated. The result of this study shows that in 2002, the total economic welfare lost in electricity industry is 137,770 million Won and under present price system, the worst welfare lost is happening seasonally in spring & fall, time periodically in the middle-load time. Specifically analyzing the characteristics of welfare lost, especially on the industry customers and service customers which are applied in seasonal and time periodic pricing, for the industry customers, the welfare lost calculated in this class occupies 51% of the total welfare lost in the whole electricity industry and the worst welfare lost is happening seasonally in spring & fall, time periodically in the middle-load time. For service customers, the welfare lost calculated in this class occupies 13% of the total welfare lost in the whole electricity industry and the worst welfare lost is happening seasonally in summer, time periodically in the peak time Finally, this study was made based on the year of 2002 and KEPCO has practiced two times of rate change until now. The result of rate change was positively analyzed in the direction of economic welfare improvement(welfare improvement achieved by 16.3% compared to 2002 result).

  • PDF

Preliminary System Design of STEP Cube Lab. for Verification of Fundamental Space Technology (우주기반기술 검증용 극초소형 위성 STEP Cube Lab.의 시스템 개념설계)

  • Kwon, Sung-Cheol;Jung, Hyun-Mo;Ha, Heon-Woo;Han, Sung-Hyun;Lee, Myung-Jae;Jeon, Su-Hyeon;Park, Tae-Young;Kang, Su-Jin;Chae, Bong-Gun;Jang, Su-Eun;Oh, Hyun-Ung;Han, Sang-Hyuk;Choi, Gi-Hyuk
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.5
    • /
    • pp.430-436
    • /
    • 2014
  • The mission objective of STEP Cube Lab. (Cube Laboratory for Space Technology Experimental Project) classified as a pico-class satellite is to verify the technical effectiveness of payloads such as variable emittance radiator, SMA washer, oscillating heat pipe and MEMS based solid propellant thruster researched at domestic universities. In addition, the MEMS concentrating photovoltaic power system and the non-explosive holding and separation mechanism with the advantages of high constraint force and low shock level will be developed as the primary payloads for on-orbit verification. In this study, the feasibility of the mission actualization has been confirmed by the preliminary system design.

Performance Evaluation and Characteristic Study of the Single Anaerobic Digestion from Piggery Slurry (돈분 슬러리를 이용한 단상 혐기소화공정의 특성연구 및 성능평가)

  • Park, Woo-Kyun;Jun, Hang-Bae;Park, Noh-Back;Kwon, Soon-Ik;Shin, Joung-Du;Hong, Seung-Gil
    • Korean Journal of Environmental Agriculture
    • /
    • v.30 no.1
    • /
    • pp.31-36
    • /
    • 2011
  • BACKGROUND: Disposal of slurry animal manure produced by an anaerobic slurry-type barn method is not easy since the animal slurry contain high moisture content which makes solid-liquid separation a difficult process. However, recently, the interest about anaerobic digestion process as an environment-friendly waste disposal method has gained a wide interest because it can treat highly organic matter contained by the piggery slurry, decrease the odor after treatment, and enable the effective recovery of the methane gas which is a valuable energy resource. The objectives of this study were to identify the solubilization characteristics and to improve the anaerobic digestion efficiency of piggery slurry through full-scale anaerobic digestion experiments. METHODS AND RESULTS: In a full-scale continuous anaerobic digestion operation, the adaptability of single anaerobic digestion and its digestion efficiency were also evaluated in the farm field. The actual pH range and alkalinity concentration of piggery slurry used during the operation were comparatively higher than the concentrations of pH and alkalinity in the digestion tank which were stable at 7.5~8.0, 4,008 mg/L (as$CaCO_3$), respectively. The removal efficiency of organic matter (TCOD) by anaerobic digestion was 75~90% and methane gas production amount was at 0.33 L/L/day, a little higher than that of ordinary animal manure. CONCLUSION(s): Our findings showed higher recovery of highly purified methane and greater efficiency of anaerobic tank digestion since its methane gas content was at 65~70%.

A study on the estimation of river water intake using the operating time of the pumping station (양수장의 가동시간을 이용한 하천수 취수량 산정방안 연구)

  • Baek, Jongseok;Kim, Chiyoung;Cha, Jun-Ho;Song, Jaehyun
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.2
    • /
    • pp.89-96
    • /
    • 2020
  • Water management agencies under the Ministry of Environment produce and accumulate qualified basic data for major rivers. However, the integrated management of the river water has been weak since the artificial water circulation process, such as the intaking and drainage of agricultural water, has not been examined in the basin, which includes many agricultural land. In this study, a study was conducted on how the power usage method (operating time method) based on the running time can be applied and improved among indirect flow rate measurement methods used to investigate flow rates collected by the riverside for agricultural water purposes, and thus the resultant data of high reliability can be obtained at low cost. The operation time method is suitable for small-scale water pumping stations where it is difficult to secure real-time power supply data. The reliability of the data was verified through the correlation analysis with the actual flow rate, and it was found that the flow rate calculated by the operation time method reflecting the level of the stream to which the inlet of the pumping station is connected can be reasonably matched with the actual flow rate. In addition, it was confirmed that the investment cost at the time of initial installation of the facility was highly efficient by generating qualified flow data at low cost through comparison with direct flow rate measurement methods. If flow data is secured by applying the operation time method to large and small water farms located along the riverside, it is expected that more quantitative and integrated stream water management will be possible.