• Title/Summary/Keyword: 전력공사

Search Result 995, Processing Time 0.023 seconds

A Security Nonce Generation Algorithm Scheme Research for Improving Data Reliability and Anomaly Pattern Detection of Smart City Platform Data Management (스마트시티 플랫폼 데이터 운영의 이상패턴 탐지 및 데이터 신뢰성 향상을 위한 보안 난수 생성 알고리즘 방안 연구)

  • Lee, Jaekwan;Shin, Jinho;Joo, Yongjae;Noh, Jaekoo;Kim, Jae Do;Kim, Yongjoon;Jung, Namjoon
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.4 no.2
    • /
    • pp.75-80
    • /
    • 2018
  • The smart city is developing an energy system efficiently through a common management of the city resource for the growth and a low carbon social. However, the smart city doesn't counter a verification effectively about a anomaly pattern detection when existing security technology (authentication, integrity, confidentiality) is used by fixed security key and key deodorization according to generated big data. This paper is proposed the "security nonce generation based on security nonce generation" for anomaly pattern detection of the adversary and a safety of the key is high through the key generation of the KDC (Key Distribution Center; KDC) for improvement. The proposed scheme distributes the generated security nonce and authentication keys to each facilities system by the KDC. This proposed scheme can be enhanced to the security by doing the external pattern detection and changed new security key through distributed security nonce with keys. Therefore, this paper can do improving the security and a responsibility of the smart city platform management data through the anomaly pattern detection and the safety of the keys.

Improvement of Information Systems with the Application of Intranet - a Case Study for an Electric Utility Company (인트라넷을 이용한 정보시스템의 개선 방향 - 전력회사의 사례를 중심으로)

  • Rieh Hae-Young
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.32 no.4
    • /
    • pp.227-248
    • /
    • 1998
  • Intranet is an internal information system which utilizes Intranet technology. Intranet is quickly adopted by many organizations worldwide. Electronic survey was conducted in Korea Electric Power Corporation where part of the information systems are offered by the Web-based systems. 842 questionnaires were analyzed to investigate the usage of the information systems and the Internet to access information. Some heavily-used and hard-to-access internal publications and outside publications were identified, and investigated whether they would be accessed via the information systems, the Internet, and the BBS. The study also Identified some problems associated with the information systems, md the users' preference of Web-based services was also examined. It was also examined whether the usage of the information systems, the Internet, and the BBS was different by some factors such as the kinds of work, the years at work, and the location of work. In conclusion, this study recommends that the Intranet should be established linking all the current systems of the company to provide wide variety of information the users want.

  • PDF

Analysis of Eddy Current and Hysteresis Loss Distribution from Fixing Structure of 154 kV Underground Transmission Cable (154 kV 지중송전선로의 고정용 금구류에서 발생하는 와전류 및 히스테리시스 손실 분포 해석)

  • Song, Hyeeun;Im, Sanghyeon;Kim, Kyoung Youn;Park, Gwansoo
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.4 no.1
    • /
    • pp.9-12
    • /
    • 2018
  • The use of underground transmission power lines is expanding for the beauty and convenience of the near city. However, there is a lack of research on the losses from underground transmission power lines, especially those that support three-phase cables operating 24 hours a day. Since the supporting the cable is made of a material having a conductivity and a magnetic permeability, an eddy current and a hysteresis loss are generated due to a magnetic field caused by a current flowing in the cable. Losses occurring in this case adversely affect the power energy transfer efficiency, so research on loss is necessary. Therefore, in this paper, we analyzed the eddy currents and hysteresis losses that occur in a supporting a cable through three - dimensional finite element analysis.

Spin Testing for the Endurance Verification of Gas Turbine Blades (고속회전시험기를 활용한 가스터빈 동익의 내구성 시험)

  • Lee, Dooyoung;Kim, Doosoo;Son, Taeha;Goo, Jaeryang
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.4 no.1
    • /
    • pp.19-24
    • /
    • 2018
  • The long-term research and development for the production of domestic blades has been consistently performed. As the direct and indirect results of its nationwide technologies in precision casting have been improved as well as maintenance costs for turbine machinery has been reduced. Whereas, there are still not a few concerns about the reliability of newly manufactured blades in spite of the quality certificate in metallurgical and mechanical properties. A spin tester is a machine that gives centrifugal loading to a rotating part, and its practical application is the overspeed test that is usually used to check the quality of products. A new spin rig has been constructed in KEPCO Research Institute for the purpose of evaluating the reliability of blades. In this paper, the test methodology for low cycle fatigue damage mechanism as well as the overspeed test for newly developed blades is described, and their reliability is evaluated too.

The Effects of Sand Compaction by Watering through Field Compaction Test and Numerical Analysis (현장 및 수치해석을 통한 모래 물다짐지반의 다짐효과 연구)

  • Chun, Byungsik;Jang, Younsoo;Kim, Kwanggyu;Park, Dukhyum;Sung, Hwadon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.8 no.6
    • /
    • pp.13-19
    • /
    • 2007
  • This study examines a cause for damage of synthetic resins straight pipe occurred after pipe construction of underground electric power duct pipelines of ${\bigcirc}$ section work, ${\bigcirc}$ line, ${\bigcirc}{\bigcirc}$ city railroad. For this, we analyzed a parameter used for plan and structural analysis through a literature review. And the site condition was analyzed in detail, and test construction of the pipe line that simulated the site pipe line and test on compaction by watering were performed. In addition, an examination on subsurface settlement influence of foundation ground through a structural safety and a numerical analysis of power transmission pipe line was performed. As a result of the performance, relative density gained by compaction by watering was more than average and relative degree of compaction according to technical specification standard showed the result of about 90% in the case of good compaction by watering.

  • PDF

A New Replacement Method of Distribution Transformers without Outage using the Phase Converter (위상변환장치를 이용한 새로운 배전변압기 무정전 교체방법)

  • Shin, Dong-Yeol;Kim, Suk-Cheol;Yoon, Gi-Gab;Cha, Han-Ju
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.10
    • /
    • pp.166-175
    • /
    • 2007
  • Nowadays, the power quality issue becomes very important in the electric distribution system. Especially, when a distribution transformer is replaced, the customers who are supplied electricity from the transformer feel inconvenience due to electric outage. Therefore, an advanced method for the distribution transformer replacement without outage is strongly required. The conventional method is the primary-secondary high voltage bypass method according to the transformer utilization factor and the field condition. But it is inconvenient and has some problems such as breakdown and security troubles of the workers according to the unauthorized and temporary work. Therefore, the new scheme for the replacement with uninterruptable power supply is demanded. This paper proposes the new replacement method using the phase converter. The proposed method can reduces the process of replacement work and also ensures worker's safety. Therefore, the method is reasonable in comparison with the conventional method. The proposed method is able to contribute the national economy growth and elevate the convenience of national life by uninterruptable power supply.

Increasing Hosting Capacity of Distribution Feeders by Analysis of Generation and Consumption (배전선로 부하량 및 발전량 분석을 통한 신재생 접속허용용량 기준 상향에 대한 연구)

  • Kim, Seong-Man
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.5 no.4
    • /
    • pp.295-309
    • /
    • 2019
  • This paper demonstrates that the verification and analysis of the increase of hosting capacity of distributed energy resources in distribution system for the high penetration of distributed energy resources. In the case of generally designed distribution feeders in South Korea, it can host up to 10 MVA of distributed energy resources and the over voltage due to reverse power flow is prohibited beyond the range by the law of electric utility. However, it should take into consideration that there are some factors of extra hosting capacity such as generation characteristics of distributed energy resources and minimum loads that always exist to distribution system. For these reason, we choose a specific distribution system hosted 10 MVA of distributed energy resources monitored by distribution system operator and verify the impact of increasing hosting capacity such as power flow and voltage profile of distribution system. By the result, we could find that it is possible to increase the hosting capacity and define the factors to expand the hosting capacity of distributed energy resources in distribution system.

An Evaluation Method for Short-Term Ratings of Double-Circuit Overhead Transmission Lines (2회선 가공송전선의 단시간정격에 관한 평가방법)

  • Kim, Sung-Duck;Sohn, Hong-Kwan;Jang, Tae-In
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.7
    • /
    • pp.20-28
    • /
    • 2007
  • This paper describes an analytical method to determine the short-term ratings to reliably operate the overhead transmission lines with double-circuit lines when faulting one circuit of the two. As linearizing the thermal equilibrium equation that represents the temperature characteristic of conductors, we show that the linear equation can be easily represented the over-current and it's temperature property during overloading the one line. Generally, it is well hewn that the short-term line ratings should be determined by considering both conductor life and dip. However, most power companies have their own different guides for the short-term ratings. Using the suggested method in this paper, it can be re-accessed the short-term ratings given in Kepco's overhead transmission lines constructed during the past three different periods. As a result, it is verified that the short-term ratings could be increased mil efficiently. Furthermore, it would be directly applied the given method to determine the short-term dynamic line ratings when occurring faults in one of the double-circuit lines, without doing my other actions for the current lines.

An Analysis on Electric Power Policy through ACMS Model : Focused on the Power Generation Subsidiary Company of the Korea Electric Power Corporation (ACMS 모형을 적용한 전력정책의 변동 분석 : 한국전력공사의 발전자회사를 중심으로)

  • Ji, Byoung-Seog;Kang, Seung-Jin
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.65 no.1
    • /
    • pp.31-40
    • /
    • 2016
  • The purpose of this study is to dimensionally examine the factors of policy changes by applying the ACMS model to KEPCO's structural reorganization privatization policies and study its implications. As a result of the analysis, among the external variables that affect as a financial source or restriction to advocates, all areas except for the difference in opinion of the people as well as policy decision and effects of other subordinate systems were shown to be in an advantageous condition acting as a financial source to advocates of structural reorganization privatization. On the other hand, advocates affected by the external variables share a certain belief system in which the advocates of privatization share the justification of profitability while the advocates of collectivization share the justification of publicness. In these flows, the announcement of the privatization plan of public enterprises of the committee of planning and budgeting acts as a matter of contact which opens the windows for policy changes, and this window goes through ignition, explosion, and fixation which causes fierce interactions among advocates of both sides. Eventually, in accordance with the contents of excluding electricity(KEPCO) from the list for privatization the window for policy changes has closed and things have changed to a transitional KEPCO privatization policy. Based on this, the first implication is that non-official participants such as the people, social organizations, labor unions, etc. influence policy changes more than they did before. Secondly, in the process of policy changes, there is an order of boundary even in the fierce interactions between each advocate. Thirdly, specific variables can play various roles in complex policy phenomenon. Fourthly, a logical analysis using the ACMS model is possible in Korea as well. Fifthly, as a result of analyzing the change process of the KEPCO structural reorganization privatization policy through the ACMS model, not all matched with the main research results implied by the ACMS model.

Efficiency and Durability of Semi-Transparent Perovskite Solar Cells for BIPV (BIPV에 활용 가능한 반투명 페로브스카이트 태양전지의 효율 및 내구성에 관한 연구)

  • Kim, Su-kyung;Kim, Do-hyung;Soh, Joon-young;Choi, Dong-hyeok;Lee, You-sun;Kwak, Min-jun
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.2
    • /
    • pp.157-161
    • /
    • 2020
  • Regarding greenhouse gas reduction, BIPV (Building Integrated Photovoltaics) is an important technology that can generate its own power in urban buildings based on clean energy resources. In particular, the perovskite material is attracting attention as a BIPV solar cell because it can have various colors and transparency. However, it is not easy to increase both transparency and efficiency factors because solar cell transparency and efficiency are inversely related to each other. Therefore, in this paper, we propose a semi-transparent perovskite solar cell structure that can improve both transparency and efficiency, and evaluate the stability according to international standard.