• Title/Summary/Keyword: 전도성 콘크리트

Search Result 62, Processing Time 0.026 seconds

Improvement of Seawater Corrosion Resistance of Concrete Reinforcing Steel Using by Conductive Photocatalyst (전도성 광촉매를 이용한 콘크리트 철근의 염해 내구성 향상에 관한 연구)

  • Bae, Geun-Guk;Bae, Geun-Woo;Ahn, Yong-Sik
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.5 no.2
    • /
    • pp.152-159
    • /
    • 2017
  • In marine environment, the durability of concrete and reinforcing steel is known to be deteriorate by the permeation of chloride ion into concrete. In this study the conductive photocatalyst was used to improve the seawater corrosion resistance of the concrete and steel. Mortar and concrete samples were prepared by mixing with various amounts of conductive active carbon and photocatalytic powder($TiO_2$). The compressive strength of concrete was decreased with the increase of the amount of conductive carbon powders. The samples containing conductive carbon and photocatalytic powders showed the superior seawater corrosion resistance compared with the ordinary sample, which was verified by XRF analysis showing the concentration of chloride ion($Cl^-$) of mortars and concretes. The inhibitive effect of photocatalyst against chloride attack was discussed with the diffusion coefficient of chloride ion into mortar and concrete.

Self-Diagnosis Properties of Fracture in Reinforced Concrete Intermixed with Conductive Materials (전도성 재료 혼입 철근콘크리트 구조체의 파괴예측 자기진단 특성)

  • Park, Seok-Kyun;Cho, Sung-Dong
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.3
    • /
    • pp.369-374
    • /
    • 2008
  • Two types of conductive materials are selected and their applicable properties are investigated so as to give the capability of self-diagnosis of fracture in composite mortar, concrete and reinforced concrete. In this study, for giving selfdiagnosis capability, the powder of cokes and milled carbon fiber as conductive materials are selected and intermixed with mortar, concrete and reinforced concrete. After examining change in the value of electric resistance before and after the occurrence of cracks at each flexural load-stage in composite mortar, concrete or reinforced concrete, the relationships of each factors (electric resistance, crack and flexural load) are analyzed. As the results, it can be recognized that conductive materials with powder of cokes and milled carbon fiber can be applied for self-diagnosis of flexural fracture in composite mortar, concrete and reinforced concrete specimen.

Improvement of Nitrogen Oxide Removal of Concrete Sidewalk Block Using by Conductive Photocatalyst (전도성 광촉매를 이용한 콘크리트 블록의 대기중 질소산화물 저감에 관한 연구)

  • Geun-Guk Bae;In-Sook Cho;Yong-Sik Ahn
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.11 no.4
    • /
    • pp.493-500
    • /
    • 2023
  • The use of TiO2 photocatalyst in the production of concrete blocks for the purpose of nitrogen oxide reduction is an issue of controversy due to the conflicting evidence on its effectiveness. Efforts have been made to reduce the level of nitrogen oxides in the environment by using of titanium dioxide (TiO2). This study examined the effect of incorporating activated carbon into concrete blocks on the reduction of nitrogen oxides released into the atmosphere and the durability of the blocks. The efficiency of photocatalyst was enhanced through the addition of a surrounding conductive substance. The addition of activated carbon resulted in a significant increase in the electrical conductivity of photocatalytic blocks and improved durability. The cement mixture using 5 % TiO2 and 15 % activated carbon exhibited the optimal mixing ratio for the purpose of nitrogen oxide removal. The effect of the addition of conductive carbon to the photocatalytic blocks was discussed with the results of conductivity, flexural and comprssive strength and nitrogen oxide removal test. The relationship between the addition of conductive carbon to the photocatalytic blocks and its resulting effects have been studied by several tests, including conductivity, flexural and compressive strength, and nitrogen oxide removal.

Crack Monitoring of RC beam using Surface Conductive Crack Detection Patterns based on Parallel Resistance Network (병렬저항회로에 기반한 표면 전도성 균열감지패턴을 사용한 콘크리트 휨 부재의 균열 감지 )

  • Kyung-Joon Shin;Do-Keun Lee;Jae-Heon Hong;Dong-Chan Shin;Jong-Hyun Chae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.5
    • /
    • pp.67-74
    • /
    • 2023
  • A large number of concrete structures are built and used around the world. To ensure their safe and continuous use, these structures require constant inspection and maintenance. While man-powered inspection and maintenance techniques are efficient, they can only provide intermittent status checks at the time of on-site inspection. Therefore, there is a growing need for a system that can continuously monitor the condition of the structure. A study was conducted to detect cracks and damage by installing a conductive coating on the surface of a concrete structure. A parallel resistance pattern that can monitor the occurrence and progression of cracks was developed by reflecting the structural characteristics of concrete structure. An empirical study was conducted to veryfy the application of the proposed method. The crack detection pattern was installed on the reinforced concrete beams, and the crack monitoring method was verified through applying a load on the beams.

Evaluation of the Exothermic Properties and Reproducibility of Concrete Containing Electro-conductive Materials (전기전도성 재료를 혼입한 콘크리트의 발열특성 및 재현성 평가)

  • Song, Dong-Geun;Cho, Hyeong-Kyu;Lee, Han-Seung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.1
    • /
    • pp.25-34
    • /
    • 2016
  • From 1990's, a study on the development of exothermic concrete, a concrete which electro-conductive material is mixed, has been proceeded. However, due to the difficulty of exothermic reproducibility of concrete specimen, the study has been unable to continuously carried out. Accordingly, this study was focused on developing an exothermic concrete for the purpose of snow-melting material. Cement paste and mortar specimens mixed with graphite, conductive metal powder and chemical admixture were made. The evaluation of exothermic performance and reproducibility was conducted under $-2^{\circ}C$ of low temperature. In addition, micro-chemical analysis was carried out to investigate a cause of exothermic reproducibility. As a test result, the specimen mixed with graphite and superplasticizer with air entrained showed the best exothermic performance and reproducibility. Through micro-chemical analysis, it is judged that polymer or methacrylic acid (MAA), the contents inside the superplasticizer with air entrained, gave exothermic reproducibility by generating the electrochemical reaction with graphite.

Structural Analysis of the Pre-weakening of a Cylindrical Concrete Silo for the Application of Overturning Explosive Demolition Method (원통형 콘크리트 사일로의 발파해체 전도공법 적용을 위한 사전취약화 구조해석)

  • Choi, Hoon;Kim, Hyo-Jin;Park, Hoon;Yoon, Soon-Jong
    • Explosives and Blasting
    • /
    • v.27 no.2
    • /
    • pp.12-18
    • /
    • 2009
  • Recently, several cases of destruction of old cylindrical silos by explosive demolition method have been reported. This study deals with the subject concerning the pre-weakening of a cylindrical concrete silo for the application of overturning explosive demolition method. In the past, the pre-weakening operation of structure in explosive demolition has been done by use of some empirical methods. These empirical approaches, however, have possibilities of unexpected accidents. In order to provide a guideline for the pre-weakening of cylindrical silos and similar structures, this paper shows the result of a case study, in which the instability of a silo due to pre-weakening is investigated by a numerical structural analysis before actually conducting pre-weakening and demolition operations.

Literature Review on Material Development and Performance Evaluation Method for EMP Shielding Concrete (EMP 차폐 콘크리트 개발 및 성능평가 방법에 관한 문헌 연구)

  • Lee, Woong-Jong;Lee, Hwan;Kim, Young-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.12
    • /
    • pp.67-76
    • /
    • 2020
  • The purpose of this study was to derive the directionality of technology development of high-power electromagnetic pulse (EMP) shielding concrete and standardization of a shielding performance evaluation method. Because the EMP shielding mechanism of concrete has not been identified clearly, and the verification method for EMP shielding performance has not been standardized, it is difficult to compare the research results between researchers. The development direction of EMP shielding concrete was derived from a consideration of the electromagnetic wave loss mechanism of metal. The standardization direction for verifying the EMP shielding performance of concrete was derived from a consideration of the electrical properties of concrete and the shielding performance evaluation methods of previous studies. As a result, the development of electrically conductive concrete is required, and test methods classified by the electromagnetic wave loss mechanism should be applied. For quality verification, the development of EMP shielding concrete will be feasible and its performance can be evaluated if a test method referencing the generalized shielding evaluation method (MIL-STD, etc.) is applied.