• Title/Summary/Keyword: 전단설계

검색결과 1,493건 처리시간 0.02초

Shear Strength Model for FRP Shear-Reinforced Concrete Beams (FRP 전단 보강 콘크리트 보의 전단강도 모델)

  • Choi, Kyoung-Kyu;Kang, Su-Min;Shim, Woo-Chang
    • Journal of the Korea Concrete Institute
    • /
    • 제23권2호
    • /
    • pp.185-193
    • /
    • 2011
  • In the present study, a unified shear design method was developed to evaluate the shear strength of concrete beams with and without FRP shear reinforcement. The contributions of FRP and concrete on shear strength were defined separately. By comparing the current design method calculated results with the existing test results, it was found that Triantafillou model shows a reliable prediction of FRP effective strain and FRP shear strength contributions. The concrete shear strength contribution was defined by the strain-based shear strength model developed in the previous study. The shear strength of concrete compression zone was evaluated based on the material failure criteria of the concrete subjected to the compressive normal and shear stresses. The proposed strength model was verified by comparing its prediction results to prior test results. The comparisons showed that the proposed method accurately predicts the strengths of the test specimens for both FRP shear reinforced and unreinforced concrete beams.

Shear Resistance of BESTOBEAM Shear Connector According to the Length (BESTOBEAM 전단연결재의 길이에 따른 전단 내력 평가)

  • Ahn, Hyung Joon;Jung, In Yong;Kim, Young Ju;Hwang, Jae Sun
    • Journal of Korean Society of Steel Construction
    • /
    • 제27권5호
    • /
    • pp.483-491
    • /
    • 2015
  • Shear resistance of BESTOBEAM, which has angle as shear connector and was developed with purpose of easy construction, was tested. With the test results shear resistance design equation was proposed. Unlike angle connector of Eurocode 4, BESTO BEMA shear connector behaves like fixed-end beam. Therefor longer span of the shear connector the lower shear resistance it has. As a result, shear resistance of BESTOBEAM shear connector according to its length tends to decrease as its length gets longer. The authors proposed design equation of angle shear connector sased on the test results. The results from the test and the proposed equation match within 10% error range. Therefore the proposed equation can be used for designing shear connector of BESTOBEAM.

Design of Shear connection in Full-Depth Precast Concrete Deck Bridge (프리캐스트 콘크리트 바닥판 교량의 전단연결부 설계)

  • Chang, Sung Pil;Shim, Chang Su;Kim, Jong Hee;Kim, Young Jin
    • Journal of Korean Society of Steel Construction
    • /
    • 제10권4호통권37호
    • /
    • pp.759-767
    • /
    • 1998
  • Full-depth precast concrete deck bridge has shear pockets for shear connectors that give composite action with steel girder. Strength and shear stiffness of shear connection that is needed to design shear connectors in case that shear pockets are filled with nonshrink mortar are investigated. In case that simple span full-depth precast concrete deck bridge is designed by allowable stress design, distribution of shear connector is suggested and details of precast panel that is placed on the support are proposed. Appropriate distribution of shear connectors in strength design and fatigue design is investigated through parameter analyses using partial interaction theory. The effects of nonshrink mortar strength is studied using the results of experiments and analyses and adequate strength is proposed.

  • PDF

Combined Design Method for Shear and Torsional Moment (전단과 비틀림모멘트 설계의 조합)

  • Min, Chang-Shik
    • Journal of the Korea Concrete Institute
    • /
    • 제23권1호
    • /
    • pp.57-65
    • /
    • 2011
  • Both shear and torsional moments apply shear stresses on cross-section of a member, which need to be considered in the design. But in the current Korean Building Code, the design equations for shear and torsional moments are expressed in terms of the sectional strength with different units, causing figures to be drawn separately in two axes. If the design equations are expressed in terms of stresses, then the stresses of shear and torsional moments can be added, allowing figures to be drawn in one axis for easy recognition of the design procedure and the final design results. Moreover, the current code's design equations for shear and torsional moments are considered separately with the intention of summing the area of stirrups with respect to unit length for shear moment ($A_{\upsilon}/s$) and torsional moment ($2A_t/s$). Since the size or type of vertical stirrups are predetermined in the design process, the design equations are expressed in terms of the spacing of stirrups rather than the $A_{\upsilon}/s$ and $2A_t/s$ terms, clarifying various design steps and a design process.

Ultimate Shear Strength of Tapered Steel Plate Girders (높이가 변하는 플레이트거더의 극한전단강도)

  • Lee, Doo Sung;Park, Chan Sik;Lee, Sung Chul
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • 제26권2A호
    • /
    • pp.391-399
    • /
    • 2006
  • Plate girders with variable depths have been often used at piers considering not only the economy but also an aesthetic aspect. Tapered plate girders exhibit more complicated behaviors than prismatic girders especially under shear. However, a comprehensive design method for the determination of the shear strength has yet to be developed mainly due to lack of study. In this study, investigated is the buckling and ultimate behaviors of tapered plate girders subjected to shear through finite element analyses. From the analysis results, a simple design formula is suggested for the evaluation of the shear strength of tapered plate girders.

Evaluation of Shear Design Provisions for Reinforced Concrete Beams and Prestressed Concrete Beams (철근콘크리트 보와 프리스트레스트 콘크리트 보의 전단설계기준에 대한 고찰)

  • Kim Kang-Su;Kim Sang-Sik
    • Journal of the Korea Concrete Institute
    • /
    • 제17권5호
    • /
    • pp.717-726
    • /
    • 2005
  • Shear test data have been extracted from previous experimental research and compiled into a database that may be the largest ever made. In this paper, the shear database (SDB) was used for evaluating shear design provisions for both reinforced concrete (RC) beams and prestressd concrete (PSC) beams. A discussion on the use of the results of this evaluation related to calibration and strength reduction factor for the shear design provisions was also provided. It was observed that the shear design provisions did not provide good predictions for RC members and gave very poor predictions especially for RC members without shear reinforcement. On the other hand, the limit on shear strength contributed by transverse reinforcement was observed to be lower than necessary. The shear design provisions gave very unconservative results for the large RC members (d>700mm) without shear reinforcement having light amount of longitudinal reinforcement $(\rho_w<1.0\%)$. However, for PSC members the shear design provisions gave a good estimation of ultimate shear strength with a reasonable margin of safety. Despite of a large difference of accuracy in prediction of shear strength for RC members and PSC members, the shear design provisions used a same shear strength reduction factor for these members. As a result, the shear design provisions did not provide a uniform factor of safety against shear failure for different types of members.

Evaluation of Design Method and Shear Transfer Capacity on the Horizontal Interface of PC Composite Beams (PC 합성보의 수평접합면 전단력 전달성능 평가 및 설계법 분석)

  • Moon, Jeong-Ho;Oh, Young-Hun
    • Journal of the Korea Concrete Institute
    • /
    • 제25권1호
    • /
    • pp.81-90
    • /
    • 2013
  • The purpose of this study is to evaluate the horizontal shear strength on the interface between PC and cast-in-place concrete for PC composite beams. Six specimens were tested to examine the structural performance of the horizontal interface with different surface condition and stirrup detailing. Except for SF-291B specimen failed in flexural compression, strengths and deformation capacities of five specimens were determined by horizontal shear failure. Horizontal shear strengths by composite horizontal shear or shear friction in current codes could be used to predict the horizontal shear capacity of the interface for specimens. Also detailing for stirrup by PCI design provision could be used to accomplish the composite action in the interface.

Comparisons of Numerical Analyses considering the Effects of Shear Strength Degradation For Nonseismic Designed RC Frame (비내진 설계된 RC 골조에 대한 전단강도 감소 효과를 고려한 수치해석의 비교)

  • Lee, Young-Wook
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • 제10권1호
    • /
    • pp.1-8
    • /
    • 2006
  • Nonseismic designed RC frame have a possibility of shear failure because of deficiencies of reinforcing details. To model the shear failure in numerical analysis, shear strength degradation models which Include Moehle's and ATC 40 are compared and applied to push-over analysis. For numerical analysis, three storied building frame is selected and designed according to Korean Concrete Design Code(2003). As results, It is shown that Moehle's shear strength degradation model estimates the shear strength lower than NZSEE model and has less variation than ATC 40 model and all the shear strengths of models are greater than the nominal shear strength of ACI 318. Also, from the numerical analysis, it is pointed out that there may be great difference in lateral drift capacity if a different shear strength model is used. And the capacity can be severely underestimated if the restraining model of plastic rotation of ATC 40 is used, compared to the use of shear spring model for shear degradation.

Design of Lead-Shear Damper for Stay Cables (사장교 케이블 진동감소용 납-전단 댐퍼의 설계)

  • 안상섭
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • 제5권1호
    • /
    • pp.31-36
    • /
    • 2001
  • 본 논문에서는 지점근처에 납-전단 댐퍼(LSD)가 설치된 케이블의 동적 거동에 대해 다루었다. 이러한 동적 거동에 대한 파악은 케이블의 진동 감소 목적으로 댐퍼를 설계하는 경우 중요한 절차중 하나이다. 납-전단 댐퍼와 같은 이력형 댐퍼의 실제 이력곡선에 기초하여 본 연구에서는 납-전단 댐퍼의 이력곡선을 완전 탄소성으로 가정하였다. 납-전단 댐퍼의 역학적 모델은 등가 켈빈 모델을 사용하였으며 케이블의 새그 효과를 고려하였다. 납- 전단 댐퍼의 용량이라고 할 수 있는 항복력을 설계변수로 선택하고 케이블에 최적의 감쇠효과를 부여하는 동적학적 관계에 대해 연구하였다. 또한 댐퍼가 케이블에 설치되는 지점과 케이블의 장력에 대한 댐퍼의 감쇠효과에 대해서도 연구하였다. 매개변수 해석결과 케이블의 기하학적 형상 및 댐퍼의 설치조건에 따라 납-전단 댐퍼가 케이블에 부가하는 감쇠의 크기가 변함을 알 수 있었으며, 이때 최대의 감쇠성능을 발휘하는 최적 항복력이 존재하는 것을 알았다.

  • PDF

Investigation of Shear Design Expressions of Large-Diameter Concrete-Filled Steel Tubes(CFT) (대구경 콘크리트 충전형 합성기둥의 전단 설계식 분석)

  • Jung, Eun Bi;Yeom, Hee Jin;Yoo, Jung Han
    • Journal of Korean Society of Steel Construction
    • /
    • 제27권4호
    • /
    • pp.399-410
    • /
    • 2015
  • Concrete filled steel tube(CFT) has outstanding deformation capacity and strength in comparison with reinforced concrete or steel tube. CFT drilled shaft, which is developed large shear force due to seismic load and soil liquefaction, is designed as large diameter. However, shear design equations of the current standards do not consider bond stress of CFT and it results in extremely conservative design. Currently, previous studies for improving shear equations scarcely exist and are impossible applied to large CFT drilled shafts since these studies focus on only small scale experimental research. In this study, eventually to propose improving shear equation of large diameter CFT, it is preliminary research to compare and investigate the previous studies and current standards.