• Title/Summary/Keyword: 전단부 길이

Search Result 129, Processing Time 0.022 seconds

Nonlinear Finite Element Analysis for RC Shear Wall with an Opening Considering Rebar Development Length (철근 정착길이를 고려한 개구부가 있는 철근콘크리트 전단벽의 유한요소해석)

  • Choi, Yun-Bum;Lee, Seong-Cheol
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.29 no.6
    • /
    • pp.547-554
    • /
    • 2016
  • In this study, nonlinear finite element analysis based on the Modified Compression Field Theory has been conducted to evaluate shear strength of RC walls with opening. On the analysis, reinforcement ratio within development length of rebars nearby the opening was reduced in the model in order to investigate the effect of opening on shear strength of RC shear walls. The nonlinear finite element analysis has been verified through comparison with the test result in literature. Through the verification, it was investigated that the analysis considering the development length of rebars well reflected the effect of an opening on shear strength of RC shear walls while current design provisions did not reasonably consider one.

Experimental Study on Bond Behavior of 1/12.5 Scale Model of the Steel Tubular Joint Connection Subjected to Compressive Loads (압축하중을 받는 1/12.5 축소모형 강관 연결부의 부착전단 거동에 대한 실험적 연구)

  • Hongseob Oh
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.28 no.3
    • /
    • pp.19-26
    • /
    • 2024
  • In this study, the compressive behavior of a 1/12.5 scale model of a wind tower support structure connection was experimentally analyzed. A high-performance cementitious grout with a compressive strength of 140 MPa was used to fill the connection, and experiments were conducted with shear key spacing, the shape, and connection length as variables. When the number of shear keys in the connection is the same, the smaller the spacing of the shear keys than the length of the connection, the higher the shear strength, and for the same spacing and connection length, the higher the height of the shear keys, the higher the strength. In addition, it was found that the strength showed a linear behaviour until the connection slip reached 1.0 mm, and it reached the maximum strength at 7.0 mm connection slip showing a non-linear behaviour as the load increased. It was found that the failure mode changed from interfacial shear failure to grout failure as the strength increased according to the shape and spacing of the shear key, and brittle failure did not occur due to steel fibers.

Effect of size and slope angle of tooth-shaped asperity on shear fracturing characteristics (삼각형 돌출부의 크기 및 경사각이 전단파괴 형상 특성에 미치는 영향)

  • Kim, Won-Keun;Choi, Woo-Yong;Park, Jong-Deok;Lee, Seok-Won
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.15 no.4
    • /
    • pp.431-442
    • /
    • 2013
  • Most of previous studies have insufficiently investigated the shear behavior and fracturing characteristics, experimentally in respect to the change of size of tooth-shaped surface asperity such as length and slope angle in a broad range. This study investigates the influence of the length and slope angle of a tooth-shaped surface asperity on the fracturing characteristics and the interface shear strength by using direct shear test apparatus. A total of 36 interface direct shear tests were conducted by changing the three types of slope angle of surface asperity, four type of length, and three types of normal stress. The shape of fractured surface after the test was quantified by using a three-dimensional surface roughness measurement apparatus. Through the experimental test results, the characteristics of fractured shape of surface asperity according to the normal stress were investigated. In addition, fractured length and height were quantified at each slope angle of surface asperity under a certain normal stress condition.

Transfer Length of the Soil Nail Induced by the Shear Deformation (전단변형에 따른 쏘일네일의 전이길이)

  • You, Min Ku;Lee, Sang Duk
    • Journal of the Korean Geotechnical Society
    • /
    • v.34 no.6
    • /
    • pp.61-73
    • /
    • 2018
  • When the shear deformation occurs on the slope reinforced with soil nail, a passive earth pressure is induced on the ground around the soil nail and the increase of shear deformation causes the earth pressure variation of the ground and the deformation and member force change of the soil nail. In this study, the shear behavior of the soil nail was analyzed experimentally by inducing the shear deformation in the vertical direction of the soil nail using a large-scale direct shear test equipment and it was verified through numerical analysis. The shear test was performed on the bonded length (6D, 8D, 10D and 12D) of the soil nail separated from the shear surface. As a result, it was observed that the continuous increase of the shear deformation caused the damage of the grout and the effect according to the bonded length was analyzed. Through the model test and the numerical analysis, it was confirmed that the transfer length of the soil nail was 0.2~0.22m, which is larger than 0.1m suggested in the previous study, and the shear zone was in the range of 0.6m from the shear surface.

Structural Performance of Hybrid Coupled Shear Wall System Considering Connection Details (접합부 상세에 따른 복합 병렬 전단벽 시스템의 구조 성능)

  • Park, Wan Shin;Yun, Hyun Do;Kim, Sun Woong;Jang, Young Il
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.3
    • /
    • pp.128-137
    • /
    • 2012
  • In high multistory buildings, hybrid coupled shear walls can provide an efficient structural system to resist horizontal force due to wind and seismic loads. Hybrid coupled shear walls are usually built over the whole height of the building and are laid out either as a series of walls coupled by steel beams with openings to accommodate doors, elevator walls, windows and corridors. In this paper, the behavior characteristics of hybrid coupled shear wall system considering connection details is examined through results of an experimental research program where 5 two-thirds scale specimens were tested under cyclic loading. Such connections details are typically employed in hybrid coupling wall system consisting of steel coupling beams and reinforced concrete shear wall. The test variables of this study are embedment length of steel coupling beam and wall thickness of concrete shear wall. The results and discussion presented in this paper provide fundamental data for seismic behavior of hybrid coupled shear wall systems.

Strength Prediction Model of Interior Flat-Plate Column Connections according to Design Parameters (설계변수에 따른 플랫플레이트-기둥 접합부의 강도산정모형)

  • Lee, Do-Bum;Park, Hong-Gun;Lee, Li-Hyung
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.3 s.93
    • /
    • pp.405-414
    • /
    • 2006
  • In the present study, a numerical analysis was performed for interior connections of continuous flat plate to analyze the effect of design parameters such as column section shape, gravity load and slab span on the behavioral characteristics of the connections. For the purpose, a computer program for nonlinear FE analysis was developed, and the validity was verified. Through the parametric study, the variations of shear stress distribution around the connection were investigated. According to the result of numerical analysis, as the length of the cross section of column in the direction of lateral load increases and gravity load increases, the effective area and the maximum shear strength providing the torsional resistance decrease considerably. And as the slab span loaded with relatively large gravity load increases, the negative moment around the connection increases and therefore the strength of connection against unbalanced moment decreases. By considering the effect of design parameters on the strength of the connections, the effective shear strength to calculate the torsional moment capacity of connection was proposed and the effectiveness of the proposed shear strength was verified.

An Experimental Research on the Shear Friction Behavior of Beam-Column Joints of Partial Precast Concrete Structures (부분PC 보-기둥 접합부의 전단 마찰 거동에 관한 실험 연구)

  • Kim, Sang-Yeon
    • Land and Housing Review
    • /
    • v.5 no.2
    • /
    • pp.91-97
    • /
    • 2014
  • An experimental program was initiated to investigate the structural capacity of PC (Precast Concrete) beam-column joints used for the underground parking structure. Static testing of 4 typical PC beam-column joints specimens was conducted. Specimens were designed to span a range of parameters typically encountered for such members, based on findings from the survey of existing PC joint details used in the construction fields in Korea. The specimens were four by their joint types and testing parameters. The specific structural behavior germane to each specimen, and general observations on overall member behavior as a function of the considered parameters, are reported. From the results of tests on four PC joints specimens, the beam-column joints of PC structure used for the underground parking building was found to have similar structural capacities when comparing to the cast-in-place concrete system.

A Study on the Asymmetric Forging Process Using Building Block Method (빌딩블럭 방법을 이용한 비대칭 단조 공정에 관한 연구)

  • J.H.Lee
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.21 no.2
    • /
    • pp.117-125
    • /
    • 1997
  • 상계요소 해석(UBET) 프로그램은 비대칭 단조공정에서의 다이 충만과정과 단조 하중등을 예측하기 위하여 개발되었다. 보다 용이하게 단조 공정을 해석하기 위하여 비대칭 형상의 단조공정을 평면변형부(길이 부분)과 축대칭변형부(라운딩 부분)으로 나누었다. 평면변형부와 축대칭 변형부의 경계는 전단에너지를 고려하여 결합하는 빌딩 블록 방법(building block method)을 이용하였다. 그리고 본 연구의 비대칭 형상을 단조하는데 최적의 초기시편 형상으로 아령형의 시편(dumbbell-typed billet)을 제시하였다. 또한 실험은 상온에서 플라스티신을 사용하여 수행되었고 수치해석 결과와 실험결과는 비교적 잘 일치하였다.상계요소 해석(UBET) 프로그램은 비대칭 단조공정에서의 다이 충만과정과 단조 하중등을 예측하기 위하여 개발되었다. 보다 용이하게 단조 공정을 해석하기 위하여 비대칭 형상의 단조공정을 평면변형부(길이 부분)과 축대칭변형부(라운딩 부분)으로 나누었다. 평면변형부와 축대칭 변형부의 경계는 전단에너지를 고려하여 결합하는 빌딩 블록 방법(building block method)을 이용하였다. 그리고 본 연구의 비대칭 형상을 단조하는데 최적의 초기시편 형상으로 아령형의 시편(dumbbell-typed billet)을 제시하였다. 또한 실험은 상온에서 플라스티신을 사용하여 수행되었고 수치해석 결과와 실험결과는 비교적 잘 일치하였다.

  • PDF

Identification of shear layer at river confluence using (RGB) aerial imagery (RGB 항공 영상을 이용한 하천 합류부 전단층 추출법)

  • Noh, Hyoseob;Park, Yong Sung
    • Journal of Korea Water Resources Association
    • /
    • v.54 no.8
    • /
    • pp.553-566
    • /
    • 2021
  • River confluence is often characterized by shear layer and the associated strong mixing. In natural rivers, the main channel and its tributary can be separated by the shear layer using contrasting colors. The shear layer can be easily observed using aerial images from satellite or unmanned aerial vehicles. This study proposes a low-cost identification method extracting geographic features of the shear layer using RGB aerial image. The method consists of three stages. At first, in order to identify the shear layer, it performs image segmentation using a Gaussian mixture model and extracts the water bodies of the main channel and tributary. Next, the self-organizing map simplifies the flow line of the water bodies into the 1-dimensional curve grid. After that, the curvilinear coordinate transformation is performed using the water body pixels and the curve grid. As a result, the shear layer identification method was successfully applied to the confluence between Nakdong River and Nam River to extract geometric shear layer features (confluence angle, upstream- and downstream- channel widths, shear layer length, maximum shear layer thickness).

A Case of Human Thelaziasis in Korea (인체 동양안충 감염 1례)

  • 류재숙;임경일
    • Parasites, Hosts and Diseases
    • /
    • v.25 no.1
    • /
    • pp.83-84
    • /
    • 1987
  • 1983년 10월에 15세된 여자가 내원 수일 전부터 오른쪽 눈의 이물감과 소양증을 주소로 내원하였다. 며칠전 환자 자신이 오른쪽 눈에서 충체를 꺼냈으며, 내원하여 2마리를 적출하였다. 두 마리는 모두 자충이었으며 각각 길이 13.4mm, 폭 0.36mm와 길이 8.3mm, 폭 0.39mm였으며 구강의 길이는 각각 0.24mm, 0.31mm이었다. 표피의 가로주름이 식도부위에서는 1mm당 281개, 중앙부위는 172개, 후단부는 162개이었으며 충체 전단부터 질 입구까지의 길이는 0.44mm이었다. 이상의 소견으로 두마리 충체를 Thelazia callipaeda로 동정하였다. 이 동양안충 감염에는 한국에서 15번째이다.

  • PDF