• Title/Summary/Keyword: 전기 접촉 저항

Search Result 300, Processing Time 0.038 seconds

Influence of electrode geometry on electrical resistivity survey: Numerical study (전극의 기하학적 형상이 전기비저항 탐사에 미치는 영향: 수치 해석 연구)

  • Tae-Young Kim;Seung-Hun Lee;Hee-Hwan Ryu;Song-Hun Chong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.25 no.2
    • /
    • pp.101-120
    • /
    • 2023
  • Electrical resistivity survey have been widely conducted at diverse scales, from a few centimeters for laboratory tests to kilometers for field tests. It measures electrical resistance through relationship of electric potential difference and current between two electrodes penetrated on the surface of medium, and eventually quantifies electrical resistivity known as inherent properties of the medium. In field or full-scale test, it assumes the electrodes as equivalent half-sphere electrodes that have a same surface area with different electrodes for ease of calculation because the contact area between electrode and medium is small and sufficient distance between two electrodes. However, small-scale laboratory test is significantly affected by the electrode geometries (penetrated depth, height, radius of electrode and distance between electrodes), which change the equipotential surface and electric current flow. Indeed, the electrode geometries may eventually cause a difference of electrical resistivity value. This study reviews the theoretical electrical resistance derived with various electrode geometries (half-sphere, cylinder, cylindrical with half-spherical tip, cylindrical with conical tip) and verifies the developed numerical module by comparing results with the theoretical electrical resistance. The distributions of electrical resistance around electrodes and among electrodes are analyzed. In addition, it is discussed how the electrical characteristic of cylindrical electrode with conical tip widely used in field test has effect on the electric current flow.

Si-Wafer위에 증착된 ITO 박막의 발수특성

  • ;Baek, Cheol-Heum;Seo, Seong-Bo;Kim, Hwa-Min
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.293-293
    • /
    • 2013
  • 최근 디스플레이산업이 발달하면서 투명전도성 물질에 대한 산업의 요구도가 높아지고 있다. ITO투명전도성 박막은 낮은 비저항과 우수한 식각특성을 가지고 있어 평면표시소자, 광소자, 터치패널 그리고 가스 센서 등 다양한 분야에 응용되고 있으며 디스플레이 소자가 소형화 되어감에 따라 박막의 다기능화가 요구되고 있다. 본 실험에서는 전기적 특성과 친, 발수특성을 동시에 가지는 다기능성 ITO 박막을 연구하였다. RIE방식으로 식각을 통하여 Poly Si-wafer 표면에 미세구조를 만든 기판과 Slide Glass기판에 RF-magnetron sputtering 방법을 이용해 ITO박막을 증착하여 비교분석 하였다. ITO박막 증착시 $100{\sim}400^{\circ}C$ 열처리와 산소를 사용하지 않고 Ar 가스만을 사용하여 실험한 후 열처리온도에 따른 전기적 특성 및 접촉각에 대하여 조사하였다. 3 uL의 Di-water를 사용하여 접촉각을 측정한 결과 $400^{\circ}C$ 열처리가 된 Poly si-wafer 위에 증착된 ITO 박막에서 초-친수 특성을 나타냈으며, 그 위에 PTFE을 증착하였을 경우 12 uL의 Di-water를 사용하여 약 $150^{\circ}$ 이상의 초-발수 특성을 나타내었다. 전기적 특성은 $5.8{\times}10^{-4}$의 비 저항을 나타내었다. 이러한 전기적 특성과 친 발수 특성을 동시에 가지는 ITO 박막은 Anti-Fogging, self-Cleaning, Solar cell 및 디스플레이소자 등 다양한 산업에 이용 가능할 것으로 생각된다.

  • PDF

Effects of Soil Resistivity on the Grounding Characteristics (대지 저항률이 접지 특성에 미치는 영향)

  • Jung, Yeon-Ha;Jang, Tae-Jun;Kwak, Hee-Ro;Roh, Young-Su;Choi, Chung-Seog
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.5
    • /
    • pp.74-79
    • /
    • 2005
  • In this paper the earth structures of four cities are analysed on the basis of the measured soil resistivity and the characteristics of a grounding system is examined. As a result it is revealed that the soil resistivity has an effect on touch voltage and step voltage, which are directly related to safety, as well as ground resistance.

Evaluation Technology of Degradation of Metallic Alloy using Electrical Resistivity (전기비저항을 이용한 금속합금 열화도 평가기술)

  • Nahm, Seung-Hoon;Yu, Kwang-Min;Ryu, Jae-Cheon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.5
    • /
    • pp.532-541
    • /
    • 2001
  • Developments of nondestructive evaluation techniques for reduction of strength or toughness by aging of material have been carried out, and the method using electrical resistivity is one of them. In this study, to examine the application of electrical resistivity to the evaluation of degradation of metallic alloy, ten different non-magnetic materials were selected as test materials. Electrical resistivities measured by DC two-point probe method and those measured by non-contact type eddy current method were compared with each other. In addition, to examine the application possibility of four-point probe technology in field, the electrical resistivities for 1Cr-lMo-0.25V steel measured by DC two-point probe method and four-point probe method were compared with each other Differences between two measured values for the 1Cr-1Mo-0.25V steel were 0.6%. Therefore, the four-point probe method can be applied to the estimation of the degradation of metallic alloy. ect.

  • PDF

Contact Diagnosis between Pipeline and Steel casing (매설배관과 압입관의 접촉 부위 진단)

  • 박경완;이선엽;전경수
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 1999.05a
    • /
    • pp.38-38
    • /
    • 1999
  • 매설배관은 도로 혹은 철길올 횡단하는 경우와 같이 굴착에 의한 시공이 불가능한 경우에 압업관을 사용하여 시공하며 이러한 압업관은 배관이 토양의 하중으로부터 안 전하게 유지되도록 하는 기능도 한다. 압엽관은 배관과 접촉이 되지 않도록 절연체 를 배관과의 사이에 삽업올 하도록 규정되어 있는데 여러 가지 이유로 배관과 접촉이 되기도 한디 배관과 압업관이 전기적으로 접촉되면 배관을 방식하기 위한 방식전류 를 압입관에 빼앗기게 되고 압업관 내부의 배관은 비방식 상태에 놓이게 되어 부석이 일어날 가능성이 높다. 본 연구는 실제 매설배관 현장에서 배관과 압입관의 접촉여부 에 대하여 조사한 방법 및 결과에 대한 것이다. 본 연구에서는 압업관의 접촉여부를 확인하기 위하여 다음과 같은 방법을 사용하 였다. 첫째. 배관과 압입관의 방식선위를 단순하게 측정하는 것이다. 배관과 압업관 의 전위가 같은가 다른가를 측정하는 방법이다. 둘째, 배관의 방식전류를 on, off하면서 배관과 압입판의 전위거동을 살펴보는 것이다. 셋째, 배관과 압업관을 언위적으로 접촉시켜 흐르는 전류량을 확인함으로써 접촉여부를 확인할 수 있었다. 넷째 배관을 따라 흐르는 방삭전류량을 측정하였다. 이상과 같은 방법을 사용하여 배판과 접촉된 압압관을 확인할 수 있었다. 접촉된 압입관에서 접촉지점을 확인하기 위하여 배관과 압입관 사이에 전류를 인가하고 압입 관의 양단의 배판 사이의 전위 변화를 측정하여 그 전위변화값과 인가한 전류값을 통 하여 계산된 저항올 배관의 길이로 환산하여 대략적인 접촉지점을 확인할 수 있었다.

  • PDF

Interfacial Control of Multi-functional CNT and ITO/PET Nanocomposites having Self-Sensing and Transparency (자체-감지능 및 광투과도를 지닌 CNT 및 ITO/PET 다기능성 나노복합소재의 계면 조절 연구)

  • Wang, Zuo-Jia;Kwon, Dong-Jun;Gu, Ga-Young;Park, Joung-Man
    • Composites Research
    • /
    • v.24 no.1
    • /
    • pp.45-50
    • /
    • 2011
  • Transparent and conductive carbon nanotube on polyethylene terephthalate (PET) were prepared by dip-coating method for self-sensing multi-functional nanocomposites. The changes in the electrical and optical properties of CNT coating mainly depended on the number of dip-coating, concentration of CNT solution. Consequently, the surface resistance and transmittance of CNT coating were sensitively controlled by the processing parameters. Surface resistance of CNT coating was measured using four-point method, and surface resistance of coated CNT could be better calculated by using the dual configuration method. Optical transmittance of PET film with CNT coating was evaluated using UV spectrum. Surface properties of coated CNT investigated by wettability test via static and dynamic contact angle measurement were consistent with each other. As dip-coating number increased, surface resistance of coated CNT decreased seriously, whereas the transmittance exhibited little lower due to the thicker CNT networks layer. Interfacial microfailure properties were investigated for CNT and indium tin oxide (ITO) coatings on PET substrates by electrical resistance measurement under cyclic loading fatigue test. CNT with high aspect ratio exhibited no change in surface resistance up to 2000 cyclic loading, whereas ITO with brittle nature showed a linear increase of surface resistance up to 1000 cyclic loading and then exhibited the level-off due to reduced electrical contact points based on occurrence of many micro-cracks.

New Power MOSFET Employing Segmented Trench Body Contact for improving the Avalanche Energy (항복 에너지 향상을 위해 분절된 트렌치 바디 접촉 구조를 이용한 새로운 전력 MOSFET)

  • Kim, Young-Shil;Choi, Young-Hwan;Lim, Ji-Young;Cho, Kyu-Heon;Han, Min-Koo
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1205-1206
    • /
    • 2008
  • 본 실험에서는 CMOS 공정에서 사용하는 실리콘 트렌치 공정을 이용하여 분절된 트렌치 바디 접촉구조를 형성, 60 V급 전력 MOSFET 소자를 제작하였으며, 결과 소자의 면적을 증가시키지 않고도 제어되지 않은 유도성 스위칭 (UIS) 상황에서 낮은 전도 손실과 높은 항복 에너지 ($E_{AS}$)를 구현하였다. 분절된 트렌치 접촉구조는 소자의 사태 파괴시 n+ 소스 아래의 정공전류를 억제한다. 이는 트렌치 밑 부분에서부터 이온화 충돌이 일어나기 때문이며, 이는 기생 NPN 바이폴라 트랜지스터의 활성화를 억제하여 항복 에너지를 증가시킨다. 기존 소자의 항복 전압은 69.4 V이고 제안된 소자의 항복 전압은 60.4 V로 13% 감소하였지만, 항복 에너지의 경우, 기존소자가 1.84 mJ인데 반하여 제안된 소자는 4.5 mJ로 144 % 증가하였다. 트렌치의 분절 구조는 n+ 소스의 접촉영역을 증가시켜 온 저항을 감소시키며 트렌치 바디 접촉구조와 활성영역의 균일성을 증가시킨다.

  • PDF

A study for test method of wire connectors (전선 연결단자의 시험방법 고찰)

  • Park, Jeong-Seok;Han, Gyu-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2003.10b
    • /
    • pp.54-56
    • /
    • 2003
  • 전기제품에 전선을 연결하는 수단으로써 단말장치를 사용한다. 단말장치는 작업자가 전선을 제품에 편리하게 연결시키도록 하는 전선결합수단이다 전기제품을 장시간 사용하다보면 외부환경 및 제품의 내구성의 변화로 인해 각종 사고가 발생한다. 그 중에 전선이 제품에 제대로 연결되어야만 제품의 성능이 발휘될 것이고 전선연결부위가 제품 성능에 영향을 주어서는 안된다. 제품에 전선의 결합강도, 전선의 접촉저항에 따른 온도 영향등을 규격에서는 이러한 영향 요소들을 평가/측정하기 위한 시험이 제시되어 있다.

  • PDF

Capacitively-coupled Resistivity Method - Applicability and Limitation (비접지식 전기비저항 탐사 - 적용성과 한계)

  • Lee Seong Kon;Cho Seong-Jun;Song Yoonho;Chung Seung-Hwan
    • Geophysics and Geophysical Exploration
    • /
    • v.5 no.1
    • /
    • pp.23-32
    • /
    • 2002
  • Capacitively-coupled resistivity (CCR) system is known to be very useful where galvanic contact to earth is impossible, such as the area covered with thick ice, snow, concrete or asphalt. This system injects current non-galvanically, i.e., capacitively to earth through line antenna and measures potential difference in a same manner. We derived geometric factor for two types of antenna configuration and presented the method of processing and converting the data obtained with CCR system suitable to conventional resistivity inversion analysis. The CCR system, however, has limitations on use at conductive area or electrically noisy area since it is very difficult to inject sufficient current to earth with this system as with conventional resistivity system. This causes low SM ratio when acquiring data with CCR system and great care must be taken in acquiring data with this system. Additionally the uniform contact between line antennas and earth is also crucial factor to obtain good S/N ratio data. The CCR method, however, enables one to perform continuous profiling over a survey line by dragging entire system and thus will be useful in rapid investigation of conductivity distribution in shallow subsurface.

Evaluation of Fiber Arrangement Condition of CF/PP Composites Using Electrical Resistance Measurement and Wettability (전기저항 평가법 및 접촉각을 이용한 CF/PP 복합재료 사출성형품 섬유 배열성 평가)

  • Kwon, Dong-Jun;Shin, Pyeong-Su;Kim, Jong-Hyun;Park, Joung-Man
    • Journal of Adhesion and Interface
    • /
    • v.17 no.1
    • /
    • pp.15-20
    • /
    • 2016
  • Fiber arrangement was important for fiber reinforced thermoplastic composites using injection fabrication. In this work, fiber arrangement in CF/PP was investigated to use electrical resistance (ER) method during injection times. There were 3 types of injection products of CF/PP with different ER change ratio by fiber arrangement. High ER change ratio case of injection CF/PP products had better increased tensile strength. This reason was due to the fiber arrangement of CF/PP by injection. Fractured surface and contact angle of CF/PP products were used to evaluate for injection product quality. Uniform fiber arrangement of CF/PP by injection type exhibited the uniform heat condition of melted CF/PP. Steady thermal transfer effect occurred from melted CF/PP to steel injection mold. Steady thermal transfer effect of CF/PP was transmitted to high ER change ratio of mold. Ultimately, good condition CF/PP product by injection molding method could be predicted by using ER method.