• Title/Summary/Keyword: 전기설비

Search Result 9,128, Processing Time 0.03 seconds

Case Study of Establishing and Operating Maker Space in A Developing Country - Focusing on iTEC Tech-shop in Tanzania - (개발도상국 메이커 스페이스 구축 및 운영 사례 - 탄자니아 iTEC 테크샵을 중심으로 -)

  • Im, Hyuck-Soon;Jung, Woo-Kyun;Ngajilo, Tunu Y.;Meena, Okuli;Lee, Ahnna;Ahn, Sung-Hoon;Rhee, Hyop-Seung
    • Journal of Appropriate Technology
    • /
    • v.6 no.2
    • /
    • pp.126-135
    • /
    • 2020
  • Recently, with the development of the 4th Industrial Revolution era and the popularization of technologies the maker movement is spreading worldwide in various ways for education, entrepreneurship, and solving social problems. This paper introduces a case of establishing and operating a maker space in Tanzania, East Africa, one of the developing countries. iTEC Tech-shop was established in the first half of 2018 at the Nelson Mandela African Institution of Science and Technology (NM-AIST) in Arusha, Tanzania by Innovative Technology and Energy Center (iTEC), and has been operating for nearly two years. With the allocation of empty warehouse space from NM-AIST, physical facilities were established through the purchase and installation of equipment and hand tools. Based on the advice from Idea Factory of Seoul National University and Fab-Lab Seoul, iTEC Tech-shop operational system were established. Through a total of 7 technical workshops, iTEC Tech-shop provided training courses for about 180 local personnel. In addition, the smart Techshop test-bed project was promoted in order to improve the operation level along with securing sustainability of the Techshop. The case of the iTEC Tech-shop could be a useful case for institutions or organizations promoting the maker movement to developing countries.

Regional Analysis of Load Loss in Power Distribution Lines Based on Smartgrid Big Data (스마트그리드 빅데이터 기반 지역별 배전선로 부하손실 분석)

  • Jae-Hun, Cho;Hae-Sung, Lee;Han-Min, Lim;Byung-Sung, Lee;Chae-Joo, Moon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.6
    • /
    • pp.1013-1024
    • /
    • 2022
  • In addition to the assessment measure of electric quality levels, load loss are also a factor in hindering the financial profits of electrical sales companies. Therefore, accurate analysis of load losses generated from distributed power networks is very important. The accurate calculation of load losses in the distribution line has been carried out for a long time in many research institutes as well as power utilities around the world. But it is increasingly difficult to calculate the exact amount of loss due to the increase in the congestion of distribution power network due to the linkage of distributed energy resources(DER). In this paper, we develop smart grid big data infrastructure in order to accurately analyze the load loss of the distribution power network due to the connection of DERs. Through the preprocess of data selected from the smart grid big data, we develop a load loss analysis model that eliminated 'veracity' which is one of the characteristics of smart grid big data. Our analysis results can be used for facility investment plans or network operation plans to maintain stable supply reliability and power quality.

Development of Multi-Reservoir System Operation Rule Curves for Hydropower Maximization in the Nam Ngum River Basin of Lao PDR (라오스 남능강 유역 다중 저수지 시스템의 최적 수력발전 운영규정 곡선 개발)

  • Lee, Hyun-Jae;Jang, Woong-Chul;Lee, Il-Ju;Lee, Jin-Hee
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.6
    • /
    • pp.803-814
    • /
    • 2022
  • The Lao government is continuously developing hydro-power dams in addition to the existing eight power plants in the Nam Ngum River basin and is expanding the power capacity of the existing power plants to meet the expected increase in electricity demand. Accordingly, the Lao government has requested an update on the existing reservoir operating rule curve in order to run the power plants efficiently. To this end, this study reviewed the current independent operating system as well as the joint operating system in order to maximize the annual power generation produced by a power plant by using CSUDP, general-purpose dynamic programming (DP) software. The appropriate operating regulation curve forms (URC/LRC, MRC) were extracted from the DP results, and the annual power generations were simulated by inputting them as the basic operating data of the reservoir operation set of the HEC-ResSim program. By synthesizing the amount of the annual power generation simulated, the existing operation regulation curve, the operational performance, and the opinion of the field operator, the optimal reservoir operation regulation curves that maximize the annual power generation of the target power plant were developed. Results revealed that a system operating in conjunction with the reservoir produces about 2.5 % more power generation than an independent reservoir due to the synergistic effect of the connection.

Case Study on Revising Curriculum of a Industrial High School through Analysis of Manufacturing Workforce demand focused on Chungnam Province in Korea (지역 기반 산업의 인력 수요 분석을 통한 공업 계열 특성화 고등학교의 교육과정 개편 사례 연구)

  • Yi, Sangbong;Choi, Jiyeon
    • 대한공업교육학회지
    • /
    • v.38 no.1
    • /
    • pp.221-238
    • /
    • 2013
  • The purpose of this study was to revise and reorganize the direction of the department of ${\bigcirc}{\bigcirc}$Industrial High School though analysis of manufacturing status and workforce demand in Chungnam province focused on the Geumsan Area. In the study, ${\bigcirc}{\bigcirc}$Industrial High School of the status and actual conditions were identified through interview, literature review and data analysis. Surveys of the school teachers, parents and students was conducted in order to investigate the awareness of renaming and reorganization of school departments, curriculum revision of the school. Statistical data was collected and analyzed in order to figure out manufacturing industry and its workforce demand of Chungnam Province in Korea. Findings of the study were as follows: Small and medium enterprises of manufacturing industry have been developed a lot in Geumsan Area in Chungnam province. Four major industries including (1) automobile parts, (2) electronic and information equipment, (3) Cutting edge culture, and (4) Agricultural-livestock and bio are intensively fostered as regional strategic industries in the Chungnam province. The manufacturing industry has a 33.6-percent, and then service-mining and manufacturing industry has a 80.0-percent of total number of employee in Geumsan Area. It is expected that industrial workforce demand of Geumsan Area come out of manufacturing and service-mining industrial sector. The following is recommended for the school curriculum revision: (1) focussing on mechanical control for the revision of computer applying mechanical department, (2) focussing on automation electric equipment for the revision of electric control department, (3) focussing on food process control for revising of bio-food industrial department. It's helpful to make a progress of the school that establish identification of industrial specialized high school as an institution of vocational education at the secondary level through supplying qualified workforce to Manufacturing industry in Chungnam Province.

A Study on pluralistic Reformation for Education of Telecommunication -for Establishment of Individual System for Comm. Education- (통신교육의 계열화와 계층화 -고유한 교역의 형성을 위하여-)

  • 조정현
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.3 no.1
    • /
    • pp.28-30
    • /
    • 1978
  • Communication actions as a social band or Human community stick (fast) to human being ceaselessly w without stopping everywhere. All of comm. actions can be kept up and developed by the education of its own. Comm. actions have to include a character of social process, and so for it the social science should t to be some essential part of it. Therefore, Comm. education have to be schemed for achieving with a point of view of synthetical s science including technical and social factor. However, recentry Comm. education be suffered to lose of itowns essential attribute and individual i independence becausing to reduce social weight recklessly in their education It is a prindiple that Comm. science is an integrate science being composed of human, social and t technical subdepartments and so comm. education have to obey for Comm. constuctional theory, i international and social claim. Originally in Korea a educational idea and genealogy forming by the comm. scientific theory has I inherited on orthodoxy. But in 1961, communication college that is only the orthodox model of Comm. education, was f forced to close by some reckless policy and then the national administration for the Comm. education h have been weakened, and so recently it’s education became to degenerate as out of genealogy or n nonsystem alike some scattering Family. On the other side, today comm. science make to it’s modern scientific factor and to keep its l integrate level, therefore, all of educational provisions and administration for the telecomm. should t to be supplement to be fit for their plural chatacters. Comm. education have to occupy an individual educational system through the comm. theory, and t then it can be coexisted with neighbour scientific field equally and can include, connect coordinate o or effect its inference in each subfactor organically. Finally, educational system for telecommunication should to be requested as preeedence that i independent field including pluralism must be formed and sufficient autonomy be guarenteed, and s so Comm. education must be to restored its orthodox genealogy and be recovered individual system a and seIfrestraint field, and then it can be accomplished its own duty for nation and society.

  • PDF

Status of Health and Safety Management in Occupational Hygiene Laboratories in Korea

  • Yang, Hyukseung;Choi, Jaewook;Yoon, Seokjoon;FARR, Terry
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.17 no.1
    • /
    • pp.53-62
    • /
    • 2007
  • 목적: 1990년대 초반부터 시작된 우리나라의 산업 보건에 대한 사회적 관심의 증대와 시장의 요구에 따라 산업위생기관의 양적인 팽창이 이루어지긴 하였으나 실험실 관련 안전보건규정이 미비한 상태에서 추진되어 산업위생 실험실에서 다양한 유해 위험성 인자를 취급함에도 불구하고 사용되는 량이 소규모로 인해 안전보건과 관련된 사항은 대부분 간과하고 있으며, 산업위생 실험실의 안전보건관리 실태는 선진외국에 비해 상당히 낙후되어 있는 실정이다. 따라서 본 연구는 우리나라 산업위생 실험실과 관련한 안전보건관리 실태를 평가함으로써 향후 실험실의 안전보건관리 수준을 향상 시키는데 효과적인 자료로 활용하는데 기여하고자 한다. 방법: 산업위생실험실의 안전보건 실태를 파악하기 위해 설문조사를 수행하였으며, 설문은 실험실의 전반적인 안전보건, 화학물질 저장 및 용기, 가연성 및 인화성 화학물질, 가스 실린더, 의사전달, 응급처치 및 비상사태 장비, 정리정돈, 소방안전, 전기안전, 개인보호구, 흄후드 및 환기, 및 이황화탄소 취급 사례로서 12개 영역으로 구성되었다. 연구대상은 2001년 한국산업안전공단 정도관리프로그램에 참여한 기관으로서 총 대상은 119개 기관이었다. 연구기간은 2002년 7월 01일부터 8월 30일까지 약 60일 이었다. 설문은 반송봉투에 넣어 설문완성 후 연구자에게 보낼 수 있도록 배려하였으며, 1차 설문을 보낸 후 2주 후에 설문 참여를 독려하기 위해 엽서를 발송하였고, 다시 2주 후에 각 산업위생기관에 개별 전화 연락을 취하였다. 그 결과 63% (75개 기관)의 완성된 설문을 얻을 수 있었다. 설문의 총 조사항목은 79문항으로 구성되어 있으며, 산업위생실험실의 안전보건 수준을 정량적으로 평가하기 위해 안전보건 매뉴얼, 교육훈련프로그램 및 한국산업안전공단 실험실 지침서를 보유한 기관과 그렇지 않은 기관간의 차이는 선별된 67문항에 대해 각 문항에 합당하거나 적절할 경우 1점을 부여하는 방식으로 점수화하였다. 이들의 관련성을 파악하기 위하여 Microsoft-Excel 2000 프로그램을 이용하여 two-tailed t-test 분석을 실시하였다. 결과 1. 산업위생실험실 운영과 관련한 67개 항목(항목별로 각 1점 부여)에 대한 안전보건 성과지수화 (100점으로 점수 환산) 결과 안전보건 매뉴얼을 보유한 기관은 $42.98{\pm}13.36$(p<0.001)점, 교육훈련프로그램을 보유한 기관은 $50.75{\pm}14.12$(p<0.01)점, 한국산업안전공단 실험실 지침서를 보유한 기관은 $43.58{\pm}11.92$(p<0.01)점으로 그렇지 않은 기관에 비해 통계적으로 유의하게 높은 점수분포를 보였다. 2. 화학물질 보관 캐비닛이 있는 기관 중 64.8%의 기관은 화학물질을 알파벳 순으로, 27.8%는 분류 기준에 따라, 그리고 7.4%는 무작위로 보관하고 있었다. 3. 단지 8.0% (6개)의 기관만이 실험실내에 눈세정 분수(2 개), 샤워기(3개) 및 눈세정물병(3개, 2개 중복 응답 기관)과 같은 응급처치 장치 및 물품을 갖추고 있었다. 4. 89.0%의 기관이 흄후드내에 화학물질을 보관하고 있었다. 5. 물질안전보건자료, 흄후드 기록지, 비상사태 절차서 및 한국산업안전공단 실험실 지침서와 같은 문서관리는 부적절하게 관리 및 기록되고 있었다. 6. 대부분의 산업위생 실험실은 응급처치 장비, 화학물질 또는 가스용기 보관실과 같은 실험실 안전설비가 부족할 뿐만 아니라 정리정돈, 화학물질 저장 캐비닛, 안전보호구 및 흄후드와 같은 관리가 미비하였다. 결론: 이상의 결과에 근거하여 기관장은 실험실의 안전보건관리를 위하여 문서관리체계를 제공하고, 모든 실험실 종사자가 적절한 개인보호구를 착용할 수 있도록 하며, 비상 장비를 설치하고, 실험실과 관련한 적절한 규정을 제정하며, 교육훈련 프로그램을 제공하여야 한다. 또한 실험실 종사자는 실험 중 적절한 개인보호구의 착용하고, 비상장비 이용에 대한 교육훈련에 참여하며, 적절한 실험실 운영관리에 대한 책임감을 가져야 한다. 위의 권고사항 이행을 위해서 KOSHA는 KQCP 프로그램에 실험실 안전보건관리 항목을 삽입하여 주기적인 평가를 수행할 필요가 있다. 우리나라 실험실의 특성을 고려할 때 본 연구결과는 일반 실험실에도 적용될 수 있을 것으로 생각된다.

A Study on the Application of Bushings Fire Prevent Structure to Prevent Fire Spread of Transformer (변압기의 화재확산 방지를 위한 부싱 방화구조체 적용에 관한 연구)

  • Kim, Do-Hyun;Cho, Nam-Wook;Yoon, Choung-Ho;Park, Pil-Yong;Park, Keun-Sung
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.53-62
    • /
    • 2017
  • Electric power which is the energy source of economy and industries requires long distance transportation due to regional difference between its production and consumption, and it is supplied through the multi-loop transmission and distribution system. Prior to its actual use, electric power flows through several transformations by voltage transformers in substations depending on the characteristics of each usage, and a transformer has the structure consisting of the main body, winding wire, insulating oil and bushings. A transformer fire that breaks out in substations entails the primary damage that interrupts the power supply to houses and commercial facilities and causes various safety accidents as well as the secondary economic losses. It is considered that causes of such fire include the leak of insulating oil resulting from the destruction of bottom part of bushings, and the chain reaction of fire due to insulating oil that reaches its ignition point within 1 second. The smoke detector and automatic fire extinguishing system are established in order to minimize fire damage, but a difficulty in securing golden time for extinguishing fire due to delay in the operation of detector and release of gas from the extinguishing system has become a problem. Accordingly, this study was carried out according to needs of active mechanism to prevent the spread of fire and block the leak of insulating oil, in accordance with the importance of securing golden time in extinguishing a fire in its early stage. A bushings fireproof structure was developed by applying the high temperature shape retention materials, which are expanded by flame, and mechanical flame cutoff devices. The bushings fireproof structure was installed on the transformer model produced by applying the actual standards of bushings and flange, and the full scale fire test was carried out. It was confirmed that the bushings fireproof structure operated at accurate position and height within 3 seconds from the flame initiation. It is considered that it could block the spread of flame effectively in the event of actual transformer fire.

Characteristics of Flue Gas Using Direct Combustion of VOC and Ammonia (휘발성 유기 화합물 및 암모니아 직접 연소를 통한 배기가스 특성)

  • Kim, JongSu;Choi, SeukCheun;Jeong, SooHwa;Mock, ChinSung;Kim, DooBoem
    • Clean Technology
    • /
    • v.28 no.2
    • /
    • pp.131-137
    • /
    • 2022
  • The semiconductor process currently emits various by-products and unused gases. Emissions containing pollutants are generally classified into categories such as organic, acid, alkali, thermal, and cabinet exhaust. They are discharged after treatment in an atmospheric prevention facility suitable for each exhaust type. The main components of organic exhaust are volatile organic compounds (VOC), which is a generic term for oxygen-containing hydrocarbons, sulfur-containing hydrocarbons, and volatile hydrocarbons, while the main components of alkali exhaust include ammonia and tetramethylammonium hydroxide. The purpose of this study was to determine the combustion characteristics and analyze the NOX reduction rate by maintaining a direct combustion and temperature to process organic and alkaline exhaust gases simultaneously. Acetone, isopropyl alcohol (IPA), and propylene glycol methyl ether acetate (PGMEA) were used as VOCs and ammonia was used as an alkali exhaust material. Independent and VOC-ammonia mixture combustion tests were conducted for each material. The combustion tests for the VOCs confirmed that complete combustion occurred at an equivalence ratio of 1.4. In the ammonia combustion test, the NOX concentration decreased at a lower equivalence ratio. In the co-combustion of VOC and ammonia, NO was dominant in the NOX emission while NO2 was detected at approximately 10 ppm. Overall, the concentration of nitrogen oxide decreased due to the activation of the oxidation reaction as the reaction temperature increased. On the other hand, the concentration of carbon dioxide increased. Flameless combustion with an electric heat source achieved successful combustion of VOC and ammonia. This technology is expected to have advantages in cost and compactness compared to existing organic and alkaline treatment systems applied separately.