Analysis of unequal electric field by metal particle in GiS (GIS 내부의 도체이물질에 의한 불평등 전계 해석)

  • Park, Kyoung-Su;Kim, Jin;Lee, Hee-Bock;Ko, Young-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2000.11c
    • /
    • pp.531-533
    • /
    • 2000
  • In compared with air insulated switchgear, GIS has a high efficiency and confidence So the transformer substation can be reduced the size to 1/10. Insulation method using $SF_6$ gas has a very excellent insulation characteristics for high pressure equipment but has a characteristics that insulation heredity is changed for internal unequal electric field. So analysis of electromagnetic field in GIS is very important basic data for structure design and trouble diagnosis process. In compared with established method, SNM in this paper observes variation of the electromagnetic field with real time and get result very similar to measurement. In order to know the variation of electromagnetic field distribution for transient response for time and position, variations are observed when the spacer is bonded and metal particles are moving fast.

  • PDF

The Effect of Non-180$^{\circ}$Domain on the Piezoelectric and Dielectric Properties of the PSN-PZT Ceramics under Alternating Strong Electric Field (교류강전계가 PSN-PZT 압전체의 압전 및 유전 특성에 미치는 non-180$^{\circ}$분역 효과)

  • 윤만순;채홍인
    • Journal of the Korean Ceramic Society
    • /
    • v.37 no.9
    • /
    • pp.871-878
    • /
    • 2000
  • 본 연구는 3mol% Pb(Sb$_{1}$2/Nb$_{1}$2/)O$_3$가 첨가된 상경계 영역의 Pb(Zr,Ti)O$_3$(PSN-PZT) 세라믹스에 대하여 RT66A와 광섬유센서를 이용하여, 교류강전계 하에서 압전 및 유전특성을 조사하였다. PSN-PZT 세라믹스의 압전 및 유전 특성에 미치는 non-180$^{\circ}$분역 재배열의 영향을 평가하기 위하여 RT66A와 MTI-2000 Fotonic$^{TM}$ sensor를 이용하여 인가전계와 주파수의 함수로 전계유기변위를 측정하였다. 그 결과, 교류강전계 하에서 전계유기변위는 강전계, 저주파수에서 큰 이력현상을 나타내고, 전계유기변위로부터 결정된 유효압전상수는 주파수가 감소할수록 증가하는 거동을 나타내고 있으며, 이러한 거동은 non-180$^{\circ}$분역 재배열의 영향으로 해석되었다.

  • PDF

A Study on 3 Dimensional Electric Field Analysis of the Finite Transmission Line (유한장 선로의 3차원 전계 해석에 관한 연구)

  • Lee, Byeong-Yoon;Myung, Sung-Ho;Min, Suk-Won;Kim, Eung-Sik;Park, Jong-Keun
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1565-1567
    • /
    • 1994
  • This paper describes a methodology for the three dimensional electric field calculation around parallel and orthogonal transmission lines. A nonuniform modeling method of finite line using linear line charges is proposed through the error analysis, Several examples of three dimensional electric field calculation are carried out by this method.

  • PDF

Finite Element Software Package for Analysis of Electric Field Distribution in Human Body (유한요소법에 의한 인체내 전계분포 해석 용 소프트웨어의 개발)

  • Woo, Eung-Je
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1993 no.05
    • /
    • pp.66-69
    • /
    • 1993
  • We have developed a software package for the analysis of electric field distribution in human body. It includes the graphical finite element mesh generator, linear system of equations solver using sparse matrix and vector technique, and post-processor for the display of the results. This software package can be used in various research areas of biomedical engineering where we inject current or apply voltage to human body. The software package was developed on Macintosh II computer and the size of the model is only limited by the main memory.

  • PDF

Comb Bandwidth generating in Frequency-shifted Feedback Laser (주파수 이동 되먹임 레이저에서 발생하는 Comb의 대역폭)

  • 지명훈;황대석;김규식;이영우
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.11a
    • /
    • pp.535-538
    • /
    • 2002
  • We simulated Frequency-shifted feedback laser using AOM inside the cavity. We analyze instantaneous oscillation frequency at peak spectral intensity and Comb bandwidth of output spectrum from Wigner-Ville distribution of intracavity electric field. The Comb bandwidth is defined as the product of the saturation-broadened bandwidth and the total resonant modes contributing to FSF operation.

  • PDF

Analysis of Electric Field Distribution of High Voltage Polymeric Bushing with Structure (초고압 폴리머 부싱의 구조에 따른 전계분포 해석)

  • Cho, Han-Goo;Yoo, Dae-Hoon;Kang, Hyung-Kyung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.489-490
    • /
    • 2008
  • This paper describes the analysis of electric field distribution of high voltage polymeric bushing with structure. The high voltage bushing consists of FRP tube and housing made of LSR. The field control can be achieved by means of the design of such internal field shaper and top corona ring as grading electrodes. In accordance, the optimized design uses both internal and external elements for electric stress grading at critical parts of the bushing. Maxwell 2D simulator based on the boundary element method was also introduced in order to verify the reliability of the polymeric bushing.

  • PDF

Simulation of Electric Potential and Electric Field for Wire-Plate Type Plasma Reactor Manufacture (선 대 평판형 플라즈마 반응기 제작을 위한 전위 및 전계 해석)

  • Lee, Dong-Hoon
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.52 no.4
    • /
    • pp.167-171
    • /
    • 2003
  • Due to advancement of industrialization, the flue gas from the combustion of industrial factories and various means of transportation have polluted air. Therefore, it is necessary to develop new techniques of air purification. In order to produce a more effective reactor, simulation were conducted using the Flux-II D program. The condition of the simulation were as follows: The height of the plate electrode was 0 mm or 2 mm higher than that of the wire electrode. The distance between the electrodes was 12 mm, and the diameter of the wire electrode was 0.5 mm or 1.0 mm. The results of the electric potential and electric field simulations show that pollutants will be more effectively removed due to the dielectric strength between wire electrode and plate electrode which was strong, and wire electrodes which were concentrated in a high electric field.

Analysis on Current Density Induced Inside Body of Hot-Line Worker for 765kV Double Circuit Transmission Line (765 kV 2회선 송전선 활선 작업자 인체내부 유도전류 밀도 해석)

  • Song, Ki-Hyun;Min, Suk-Won
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.5
    • /
    • pp.231-238
    • /
    • 2006
  • This paper analysed the induced current density inside human body of hot-line worker for 765kV double circuit transmission line according to locations of human body. Human model was composed of several organs and other parts, whose shapes were expressed by spheroids or cylinders. Organs such as the brain, heart, lungs, liver and intestines were taken into account. Applying the 3 dimensional boundary element method, we calculated induced current density in case a worker was located inside and outside a lowest phase of 765 kV transmission line in which a 60% current of maximum load flowed. As results of study, we found a maximum induced current density in all organs was less than $10mA/m^2$ when a wonder was outside. As one in brain and heart was higher than $10mA/m^2$ when a worker was inside, we propose a method for lowering current density.

A Study of Optimum Electromagnetic Field Analysis and Application of the Electret Sensor Using Computer Simulation (컴퓨터 시뮬레이션에 의한 일렉트렛트 센서의 최적 전계 해석과 응용)

  • 정동회;김상걸;김성렬;김용주;김영천;이준웅
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.435-438
    • /
    • 1998
  • In this paper, Electret is formed to range voltage -5[kV] to -8[kV] by corona charging in PTFE film and sensor is manufactured by method of moments in sensing infra sonic. Charges of charged film are calculated also TSC measurement and induced potential of sensing electrode according to the charges is become aware of computer simulation. Electret Infra Sonic Transducer, which is designed and manufactured according to the potential and electric field simulation in using method of moments, is proved as it is effectively. Because sensitivity that measured under 10[Hz] is that average value of sensitivity rising rate is 6.34 [dB/oct] as average value is $\pm$1 [dB/oct] range -5[kV] to -8[kV] in corona charging film. As a result, it is believed that characteristic of acquired transducer can be application of medical treatment, industry, and animal life researches and the study of noise elimination, what's more, is required.

  • PDF

Analysis on the Current distribution and its Rodiating Electric Field of the arbitrary linear Antenna (임의의 선형 안테나의 전류분포와 그 복사전계해석)

  • 주창복
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.5 no.1
    • /
    • pp.76-82
    • /
    • 1980
  • In this paper, an arbitrary Iinear antenna is divided into many small sections and numeral analysis by moment method is carried out. So, the equation which is closed to the actual current distribution and solved easily compared with the induced-emf method or retarded potencial method is derived. The current distribution and radiating pattern of the three element Yagi antenna which applied the result is well in accord with the theoritical values.

  • PDF