• Title/Summary/Keyword: 적정조도

Search Result 562, Processing Time 0.027 seconds

Optimum Size Selection and Machinery Costs Analysis for Farm Machinery Systems - Programming for Personal Computer - (농기계(農機械) 투입모형(投入模型) 설정(設定) 및 기계이용(機械利用) 비용(費用) 분석연구(分析硏究) - PC용(用) 프로그램 개발(開發) -)

  • Lee, W.Y.;Kim, S.R.;Jung, D.H.;Chang, D.I.;Lee, D.H.;Kim, Y.H.
    • Journal of Biosystems Engineering
    • /
    • v.16 no.4
    • /
    • pp.384-398
    • /
    • 1991
  • A computer program was developed to select the optimum size of farm machine and analyze its operation costs according to various farming conditions. It was written in FORTRAN 77 and BASIC languages and can be run on any personal computer having Korean Standard Complete Type and Korean Language Code. The program was developed as a user-friendly type so that users can carry out easily the costs analysis for the whole farm work or respective operation in rice production, and for plowing, rotarying and pest controlling in upland. The program can analyze simultaneously three different machines in plowing & rotarying and two machines in transplanting, pest controlling and harvesting operations. The input data are the sizes of arable lands, possible working days and number of laborers during the opimum working period, and custom rates varying depending on regions and individual farming conditions. We can find out the results such as the selected optimum combination farm machines, the overs and shorts of working days relative to the planned working period, capacities of the machines, break-even points by custom rate, fixed costs for a month, and utilization costs in a hectare.

  • PDF

Treatment of Garbage Leachate with Two-phase Anaerobic Digestion Coupled with Ultra Filtration (막결합형 2상 혐기성 소화 공정을 이용한 음식물 탈리액 처리)

  • Lee, Eun-Young;Kim, Hyung-Kuk;Giang, Luu Thi Thuy;Bae, Jae-Ho;Bae, Young-Shin;Won, Jong-Choul;Lee, Jae-Hoon;Park, Seung-Kyun;Cho, Yong-Wan
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.11
    • /
    • pp.997-1006
    • /
    • 2009
  • Organic removal efficiency and methane production rate, a feasibility of power generation from biogas, and the optimum conditions for membrane operation were evaluated for the pilot scale (5 tons/day) two-phase anaerobic digestion coupled with ultra filtration (TPADUF) system fed with garbage leachate. The TPADUF system is consisted of a thermophilic acidogenic reactor, a mesophilic methanogenic reactor, and an UF membrane. When garbage leachate with 150 g/L of TCOD was fed to the TPADUF up to organic loading rate (OLR) of 11.1 g COD/L/d, the effluent TCOD was lower than 6 g/L and the average removal efficiencies of TCOD and SCOD were higher than 95%. The methane composition of the gas was 65%, and the methane yield was 39 $m^3/m^3$ garbage leachatefed, 260 $m^3$/tons $COD_{added}$, or 270 $m^3$/tons $COD_{removed}$, even there was some gas leak. The power production per consumed gas was 0.96 kWh/$m^3$ gas or 1.49 kWh/$m^3$ methane. This lower power production efficiency mainly due to the small capacity of gas engine (15 kW class). The membrane was operated at the average flux of 10 L/$m^2$/hr. When the flux decreased, washing with water and chemical (NaOCl) was conducted to restore the flux. In the TPADUF system, optimum pH could be maintained without alkali addition by recycling the membrane concentrate or mixed liquor of the methanogenic digester to the acidogenic reactor. Also, partial production of methane in the acidogenic reactor had a positive effect on lowering the OLR of the methanogenic reactor.

Analysis and Improvement Measures on the Status of the Installation and Operation of Facilities for Recycling Food Waste into Compost (음식물쓰레기 퇴비화시설의 설치 및 운영 현황분석 및 개선방안)

  • Ryu, Ji-Young;Kong, Kyu-Sik;Shin, Dae-Yewn;Phae, Chae-Gun
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.12 no.3
    • /
    • pp.95-111
    • /
    • 2004
  • This research sought to determine the status of the installation and operation of composting facilities of domestic public resource-making facilities and come up with corresponding improvement measures. The composting facilities were the most extensively installed of related facilities with over a 0.5 ton treated volume per day. The monthly and yearly carry-in volume of food waste were found to stand at 1,101.7 tons per day and 930.9 tons per day, thus falling short of the average planned volume of 1,270.9 tons. Many composting facilities, which were installed in areas for which factory registration were not approved, did not get approvals. Composting facilities underwent operation stoppage mainly due to faulty fermentation and crushing equipment. Mainly metals contained in food waste caused faults to the crushing equipment, thus requiring a facility designing against faults and corrosion. The initial water content was found to stand at 50-60%, thus complying with the requirement. However, since the composting food waste had an appropriate mixture of sawdust, food waste, and returned compost, it should meet the initial conditions. For fermentation facilities, the duration time for fermentation was 15 days, and post-fermentation tanks required 21 days of duration time, thus establishing the minimum criteria. However, some facilities did not meet the requirements, taking more time in decomposition, thus suggesting a need to determine the duration time according to facilities. In composting food waste, microorganism-based thermal oxidizer-operated fermentation tanks should be used to ensure an economic operation. On the contrary, 14 out of 25 survey targets heated fermentation tanks in any form. These thermal facilities contain the growth of bacteria, lowering chemical reaction in composting; thus composting facilities should be basically designed to use microorganism-based thermal oxidizers in drying water. An average daily volume of food waste and supplementary materials that was injected in producing compost was 22.8 tons. This volume produced 7.3 tons of compost per day, decreasing 68%. Properties of produced compost were analyzed by its color, absence or presence of remaining decomposition heat, and smell, to assess the quality. As a result, the composting process was not properly installed nor operated in about 50% of composting facilities. Compost should be produced to be soil-friendly.

  • PDF

Calculating the Audit Fee Based on the Estimated Cost (예정원가계산에 의한 감사보수 산정)

  • Mun, Tae-Hyoung
    • Management & Information Systems Review
    • /
    • v.35 no.1
    • /
    • pp.189-206
    • /
    • 2016
  • It was required to attach the documents on the details of external audit including the number of the participants in external audit, audited parts and audit times under the Article 7-2 on the audit report to the accounting audit report from 2014 in accordance with the amendment to the Act on External Audit of Stock Companies. This study aim to calculate the audit fee based on the estimated cost of service calculation of the government contribution agencies by reflecting the implementation of the revised external audit. This study calculated the audit fee for the target company (a listed company assumed to have no internal control risks and relevant audit risks for unqualified opinion in the previous year, 100 billion won of total amount of asset, manufacturing company in the previous year and preliminary client request) by putting together four items of expenditure including employment costs, expenditure, general management expenses and profit in accordance with the calculation system of cost of service under the State Contract Act. Then, it used the data collected from the documents on the details of the revised external audit after requesting estimation on the target company with the estimated cost to Big-4 accounting firms to identify the participants and times of the accounting audit. The employment costs applied 150% of participation rate of the base price of employment costs for the academic research service cost in 2014, the expenditure used the average value of accounting firms of corporate business management analysis of the Bank of Korea (2013), the general management expenses applied 5% of the general management rate of service business under Article 7-1 of the Enforcement Rule of the Act on Contracts to which the State is a Party and the profit applied 10% of profit rate of service business under Article 7-2 of the Enforcement Rule of the Act on Contracts to which the State is a Party. Based on the calculation of the estimated costs by applying the above, the audit fee was estimated at 50,617,769won. Although the result is not the optimal audit fee, it may be used as a basic scale to compare the audit fees of companies without criteria. Also, such amendment to the Act on External Audit of Stock Companies may improve independence of auditors and transparency of the accounting system rather than previous announcing only the total audit times.

  • PDF

The Heat Transfer Performance of a Heat Pipe for Medium-temperature Solar Thermal Storage System (중온 태양열 축열조용 히트파이프의 열이송 성능)

  • Park, Min Kyu;Lee, Jung Ryun;Boo, Joon Hong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.69-69
    • /
    • 2011
  • 태양열 발전 플랜트에 사용되는 중고온 범위의 축열조에 고체-액체간 상변화를 수행하는 용융염을 축열물질로 사용하면 액체상 또는 고체상만으로 된 열저장 매체에 비해 축열조의 규모를 축소함과 동시에 축열온도의 균일성 향상에 기여할 수 있다. 중온인 $250{\sim}400^{\circ}C$ 범위에서 이용 가능한 용융염으로는 질산칼륨($KNO_3$), 질산리튬($LiNO_3$)등이 있다. 그러나 이러한 용융염의 가장 큰 단점은 열전도율이 매우 낮다는 것이며, 이로 인해 요구되는 열전달률을 성취하기 위해서는 많은 열접촉면적이 필요하다는 것이다. 이러한 단점을 극복하는 방법을 도입하지 않고서는 축열시스템의 소규화를 성취하는데 큰 효과를 가져올 수 없다. 한편 열수송 성능이 탁월한 히트파이프를 사용하면 열원 및 열침과 축열물질 사이의 열전달 효율을 증가시켜 시스템의 성능 향상과 동시에 소규모화에 기여할 수 있다. 중온 범위 히트파이프의 작동유체로서 다우섬-A(Dowtherm-A)는 $150^{\circ}C$이상 $400^{\circ}C$까지의 범위에서 소수에 불과한 선택적 대안 중 하나이다. 따라서 본 연구에서는 용융염을 사용하는 중온 태양열축열조에 적용 가능한 다우섬-A 히트파이프의 성능을 파악하여 기술적 자료를 제시하고자 하였다. 열원으로는 고온 고압의 과열증기, 그리고 열침으로는 중온의 포화증기를 고려하였다. 용융염 축열조를 수직으로 관통하는 히트파이프는 하단부에서 열원 증기와 열교환 가능하며, 중앙부에서 축열물질과 열교환하고, 상단부에서는 중온 증기와 접촉할 수 있도록 배치하였다. 축열모드에서는 히트파이프의 하단부가 증발부로 작동하고, 중앙부가 응축부로 작동하여 용융염으로 열을 방출하면 용융염의 온도가 상승하고 용융점에 도달하면 액상으로의 상변화가 진행되면서 축열이 활성화된다. 축열모드에서 히트파이프의 상단부는 단열부로 작동한다. 방열과정에서는 히트파이프의 하단부가 단열된 상태이고, 중앙부는 용융염으로부터 열을 받아 증발부로 작동하며, 상단부는 중온 증기로 열을 방출하므로 응축부로 작동한다. 즉, 축열시스템의 작동모드에 따라 하나의 히트파이프에서 증발부, 응축부, 단열부의 위치가 변하게 된다. 특히, 히트파이프의 중앙 부분이 응축부에서 증발부로 전환될 때에도 작동이 보장되려면 내부 작동유체의 연속적인 재순환이 가능해야 하므로, 일반 히트파이프에서와는 달리 초기 작동액체의 충전량을 증발부 전체의 체적보다 더 많이 과충전해야 한다. 이러한 히트파이프의 성능 파악을 위한 실험에서 고려한 변수들은 열부하, 작동액체의 충전률, 작동온도 등이며, 열수송 성능의 지표로서는 유효열전도율과 열저항을 이용하였다. 중온범위에서 적정한 작동온도를 성취하기 위해 실험에서는 전압 조절기로 열부하를 조절하는 동시에 항온조로 응축부의 냉각수 입구 온도를 제어하였다. 하나의 히트파이프에 대해서 최대 1 kW까지의 열부하에서 냉각수 입구 온도를 $40^{\circ}C$에서 $80^{\circ}C$ 범위로 변화시키면 히트파이프 작동온도를 약 $250^{\circ}C$ 내외로 조절 가능하였다. 히트파이프 작동액체 충전률은 윅구조물의 공극 체적을 기준으로 372%에서 420%까지 변화 시켰다. 실험 결과를 토대로 열저항과 유효 열전도율을 각각 입력 열유속, 작동온도, 작동액체 충전률 등의 함수로 제시했다. 동일한 냉각수 온도에서는 충전률이 높을수록 히트파이프의 작동온도가 감소하였다. 열저항 값의 범위는 최소 $0.12^{\circ}C/W$에서 최대 $0.15^{\circ}C/W$까지로 나타났으며 유효 열전도율의 값은 최소 $7,703W/m{\cdot}K$에서 최대 $8,890W/m{\cdot}K$까지 변화했다. 최소 열저항은 충전률 420%인 경우에 나타났는데 이때의 작동온도는 약 $262^{\circ}C$이었다. 히트파이프의 작동한계로서 드라이아웃(dry-out)은 충전률 372%의 경우에 열부하 950 W에서 발생하였으나, 그 이상의 충전률에서는 열부하 1060 W까지 작동한계 발생이 관찰되지 않았다. 실험 결과 본 연구에서의 히트파이프는 중온 태양열 축열조에 적용되어 개당 약 1 kW의 열부하를 이송하면서 축열물질 및 축방열 대상 유동매체와 열교환을 하는데 사용하는데 충분할 것이라 판단된다.

  • PDF

Studies on the chemical composition of citrus fruits in Korea(I) -The chemical composition of main varieties- (한국산(韓國産) 감귤류(柑橘類)의 화학성분(化學成分)에 관(關)한 연구(硏究)(I) -주요(主要) 감귤품종별(柑橘品種別) 화학성분함량(化學成分含量)에 관(關)하여-)

  • Yang, C.B.;Park, H.;Kim, Z.U.
    • Applied Biological Chemistry
    • /
    • v.8
    • /
    • pp.29-37
    • /
    • 1967
  • Citrus fruits of ten varieties grown in Chaeju island and a few other fruits for the comparison were analyzed to determined the contents of crude fat, crude fiber, total carbohydrates, macroelements and ash. Acids and sugars in fruit juices were also determined and the characteristic of neutralization of fruit juices were investigated. 1. The per cent of edible part of citrus fruits having the range of 48.5(Daingwoochi) to 72(Onju) were lower than that of other fruits. It was lower by about 8 per cent than that of the same variety produced in U.S.A. It was shown that the amount of rind per fruit might be increased in the citrus fruit grown in the low annual temperature. 2. The content of crude protein were around 1% and higher than other's. The contents of crude fat were below 0.1% in three varieties and over 0.1 in others. The contents of crude fiber were between 0.3 to 0.8% and the fruits with the high content of crude protein were inclined to have the high content of crude fiber and it was also shown that the low annual temperature was inclined to increase the amount of crude fiber per fruit. 3. The amount of total acid were from 19.5 m.e per 100 g of fresh fruit in Byongkyul to 44.2 m.e in Daingwoochi. The high percentage of titrable acid was over 90 in two sour varieties, Daingwoochi and Hakyul having pH below 3 and the high content of total acid. These two varieties were above 10 in the ratio of total acid in the edible part to the total acid in the rind(total acid in edible part/total acid in the rind). The content of combined acid was lower than that of titrable acid in the edible part and vice versa in the rind. 4. Navel was highest as 12.82% in the total sugar content and the lowest content was 4.9% of Hakyul. The contents of reducing sugar in the citrus fruits were about half of that in other fruits. The ratio of total sugar to titrable acid (sugar/acid: the grade of sweet taste) were lower than foreign products . 5. From the titration curves of fruit juices the characteristic of neutralization of juices could be grouped in three types, and other values, that is, pH, the content of total acid, the percentage of combined acid, the ratio of total acids in edible part and rind, the content of sugar, and the grade of sweet taste were also devided into the same three categories. 6. The contents of macroelements were different along to the each part of fruit. The content, in the seed were high and the ones in the rind were low. The contents of each element were in the order of $K_2O>N>P_2O_5{\gtrless}CaO{\gtrless}MgO$ in the edible part, $K_2O>N>CaO>P_2O_5{\gtrless}MgO$ in the rind, $N>K_2O>P_2O_5>CaO>MgO$ in the seed. The content of potassium was especially high in Marumeru and Hakyul and the content of calcium in citrus fruit was higher than others.

  • PDF

Determination of the Optimum Sampling Area for the Benthic Community Study of the Songdo Tidal Flat and Youngil Bay Subtidal Sediment (송도 갯벌과 영일만 조하대 저서동물의 군집조사를 위한 적정 채집면적의 결정)

  • Koh, Chul-Hwan;Kang, Seong-Gil;Lee, Chang-Bok
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.4 no.1
    • /
    • pp.63-70
    • /
    • 1999
  • The optimum sampling area which can be applied to the benthic community study is estimated from large survey data in the Songdo tidal flat and subtidal zone of Youngil Bay, Korea. A total of 250 samples by 0.02 $m^2$ box corer for the benthic fauna in Songdo tidal flat and 50 samples by 0.1 $m^2$ van Veen grab in Youngil Bay were taken from the total sampling area of 5 $m^2$. It was assumed that the sampling area could contain sufficient information on sediment fauna, if cumulative number of species, ecological indices, and similarity index by cluster analysis reflect the similarity level of 75% to those found at total sampling area (5 $m^2$). A total of 56 and 60 species occurred from Songdo tidal flat and Youngil Bay, respectively. The cumulative curve of the species number ($N_{sp}$) as a function of the sampling area (A in $m^2$ ) was fitted as $N_{sp}=37.379A^{0.257}$ ($r^2=0.99$) for intertidal fauna and $N_{sp}=40.895A^{0.257}$ ($r^2=0.98$) for subtidal fauna. Based on these curves and 75% of similarity to the total sampling area (5 $m^2$), the optimum sampling area was proposed as 1.6 $m^2$ for the intertidal and 1.5 $m^2$ for the subtidal fauna. Ecological indices (species diversity, richness, evenness and dominance indices) were again calculated on the basis of species composition in differently simulated sample sizes. Changes in ecological indices with these sample sizes indicated that samplings could be done by collecting fauna from < 0.5 $m^2$-1.5 $m^2$ on the Songdo tidal flat and from < 0.5 $m^2$-1.2 $m^2$ in Youngil Bay. Changes in similarity level of all units of each simulated sample size showed that sampling area of 0.3 $m^2$ (Songdo tidal flat) and 0.6 $m^2$ (Youngil Bay) should be taken to obtain a similarity level of 75%. In conclusion, sampling area which was determined by cumulative number of species, ecological indices and similarity index by cluster analysis could be determined as 1.5 $m^2$ (0.02 $m^2$ box corer, n=75) for Songdo tidal flat and 1.2 $m^2$ (0.1 $m^2$ van Veen grab, n=12) for Youngil Bay. If these sampling areas could be covered in the field survey, population densities of seven dominant species comprising 68% of the total faunal abundance occurring on Songdo tidal flat and six species comprising 90% in Youngil Bay can be estimated at the precision level of P=0.2.

  • PDF

High-Rate Phosphorous Removal by PAC (Poly Aluminum Chloride) Coagulation of A2O Effluent (생물공정 처리수의 PAC (Poly Aluminum Chloride) 응집에 의한 고효율 인 제거 특성)

  • Hwang, Eung-Ju;Cheon, Hyo-Chang
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.8
    • /
    • pp.673-678
    • /
    • 2009
  • High-rate phosphorous removal by PAC (poly aluminum chloride) coagulation of A2O effluent was investigate to meet the stringent requirement of wastewater discharge from municipal wastewater treatment plant. A series of jar tests were conducted to find optimum coagulation condition and to enhance removal efficiency. The optimum volumetric concentration of PAC was 30 ppm (2.81mol Al/mol P by mol ratio). Only 17.2% of soluble P was removed for 30 minutes' settling without PAC addition, while this increased to 30.3% by dosing 10ppm PAC. It even increased conspicuously from 49.3% to 88.4% by increasing PAC dose from 20 ppm to 30 ppm. 92.4% of total P was removed by 30 ppm PAC, and the effluent concentration (0.3 mg/L) was acceptable for discharge. The optimum value of coagulation time, settling time, and pH were 4minutes, 20 minutes, and 7.0, respectively. It was not necessary to control pH of raw sample whose pH was 7.0. Soluble P removal was remarkably enhanced at pH 7.0. This implied that sweep floc formation by $Al(OH)_3$ was the main mechanism of coagulation for soluble P removal. Influent and effluent of secondary clarifier were tested for coagulation, and the effluent was better for high-rate P removal. It resulted in 0.18 mg/L of P and 95.4% of P removal by coagulation. It was favorable to recycle the treated water to coagulation tank and the optimum recycle ratio was 0.3.

Legal Research about the Public Offering of Director Compensation (이사보수의 공개에 관한 법적 연구)

  • Kwon, Sang-Ro
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.10
    • /
    • pp.169-177
    • /
    • 2012
  • Due to the influences of global financial crisis, countries are putting their efforts on the enhancement of appropriateness and transparency of director compensation. In several countries including Germany, the United States, the United Kingdom, France, and Italy, listed companies and financial institutions in certain levels make public announcement for compensations of individual directors, not the averages. Recently, even Asian countries including China, Hong Kong, and Singapore are introducing individual director compensation public announcement policies. On the other hand, in cases of companies, which must submit annual reports, under current Korean capital market laws and enforcement ordinances, they are obligated to mention 'total wage paid to all executives in that business year' on the annual report, but does not have to mention individual wages of each executive. About this, at the 17th national assembly, revised bill for the Securities and Exchange Act for companies to mention wages of each executive. The financial world is opposing to open individual director compensation to the public as they concern about the shrinking of outstanding human resources recruitment, breach of corporate confidence, privacy invasion, deterioration of labor-management relations, and downfall of the executive's management will as director compensation will be standardized downward; however, if public opening of individual director compensation is forced, domestic companies will prepare more objective and rational standards when they calculate director compensations, and moreover, it will prevent arbitrary intervention of dominant shareholders. Therefore, to clearly and efficiently control director compensation, we need regulations for obligating public opening of individual director compensation.

Quality Characteristics of Sikhye made with Berries (베리류로 제조한 식혜의 품질 특성에 관한 연구)

  • Yang, Ji-won;Jung, Sung Keun;Song, Kyung-Mo;Kim, Young Ho;Lee, Nam Hyouck;Hong, Sang Pil;Lee, Kyung Hee;Kim, Young-Eon
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.25 no.6
    • /
    • pp.1007-1017
    • /
    • 2015
  • This study compared the physicochemical characteristics, proximate composition, taste compound, and antioxidant properties of Sikhye prepared with berries. Proximate composition and color were significantly different depending on the type of berry, whereas crude fat content and pH were not. The highest brix degree was $18.92^{\circ}Bx$ in strawberry Sikhye. Total free sugar, glucose, and fructose contents were highest in blueberry Sikhye. Titratable acidity, total acidity, and organic acid contents were highest in raspberry Sikhye. Analysis of relative antioxidative properties indicated that bokbunja Sikhye had the highest total polyphenol, flavonoid, and anthocyanin contents, highest DPPH radical scavenging ability, and highest reducing power and ferric reducing abilities in plasma. Principal component analysis suggests that bokbunja Sikhye has strong antioxidant and sweetness properties.