• Title/Summary/Keyword: 적절하중

Search Result 572, Processing Time 0.022 seconds

Design Methodology of Transverse Post-Tensioning for Prestressed Concrete Pavements (프리스트레스트 콘크리트 포장의 횡방향 긴장 설계방안)

  • Kim, Seong-Min;Yoon, Dong-Joo;Bae, Jong-Oh
    • International Journal of Highway Engineering
    • /
    • v.10 no.4
    • /
    • pp.269-279
    • /
    • 2008
  • This study was conducted to develop the design methodology of transverse post-tensioning for the prestressed concrete pavement (PSCP). The transverse stress distribution was analyzed when the transverse anchor spacing changed. The tensile stress distribution in the PSCP slab due to the environmental and vehicle loads was also investigated. The reasonable methods were discussed to determine the design loads including environmental and vehicle loads and the PSCP allowable tensile stress used for the basis of the selection of the stress application amount from the tensioning. The results of this study showed that as the transverse anchor spacing increased, the range of the stress loss became larger and the stress loss was significant near the shoulder. The design of the transverse post-tensioning can be performed by obtaining the stresses under the design loads and by considering the allowable tensile stress; however, the tensile stresses at different locations such as the shoulder, wheel pass, and slab interior should also be checked and kept below the allowable tensile stress.

  • PDF

An Efficient High-Frequency Vibration Analysis of Floors in Building Structures (고차의 진동하중을 받는 건축물 바닥판의 효율적인 진동해석)

  • Lee, Dong-Guen;Kim, Tae-Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.10 no.5 s.51
    • /
    • pp.35-48
    • /
    • 2006
  • The object of this study is to propose the efficient method for analyzing the building floors subjected to the loading with high frequency contents. For this purpose, the method for mesh division and the selection of master DOF for FE model of building floors with these loadings are studied. Also, it is verified that the availability of thin plate element that is used by structural engineers for the modelling of the building floor of which the span-thickness ratio is usually ten times and over. And the possibility and limit of the equivalent plate which is already studied by other researcher for the multi-layer plate are investigated. At last, proposed modelling method is examined by the example structure.

Photo Sensor Based Measurement and Noise Reduction of Dynamic Weights (광 센서에 기반한 동하중의 측정 및 잡음 감소)

  • Shin, Dae-Jung;Na, Seung-You;Kim, Jin-Young
    • The KIPS Transactions:PartC
    • /
    • v.12C no.4 s.100
    • /
    • pp.519-524
    • /
    • 2005
  • Due to various types of errors added to dynamic weight measurement data, proper methods to reduce measurement errors are required to produce reliable weights. It is very difficult to reduce the measurement error due to excessive oscillation of the system. To cope with parasitic types of errors in real systems, information provided by the photo sensors are utilized and combined in such a way to reduce the measurement errors of load cells. In addition to four channels of load cells from a model trailer, photo sensors are used to obtain the information to compensate the error induced from vertical movement of the vehicle due to the variation of ground level. A model trailer system is run to verify the effectiveness of the proposed method to reduce noise of dynamic weight measurements.

Stability Analysis of Existing Tunnel in Stratified Sedimentary Rocks Subjected to Bridge Pier Load (퇴적암 지역에서의 교각 기초 하중을 받는 기존터널의 안정성에 대한 해석적 고찰)

  • 김교원
    • The Journal of Engineering Geology
    • /
    • v.8 no.2
    • /
    • pp.153-161
    • /
    • 1998
  • An anisotropic characteristics of stratified sedimentary rocks should be considered in the design of tunnel. The second line of Taegu subway is under construction through the sedimentary rocks which is stratified by alternation of shale and sandstone, and Tongsoe over bridge road is planned to be constructed along the subway line. Thus the subway twin tunnels will be subjected by the bridge load of 76.2 MN per pier that will be placed in between the twin tunnels of the subway line. A numerical analysis is carried out for the stability of the twin tunnel, and the result shows that the maximum principal stress of surrounding ground is increased by 5∼6 MPa and the additional displacement of concrete lining is reached up to 8∼10mm due to the external bridge load. For the safety operation of the subway, reinforcement of the tunnel structure is highly recommended.

  • PDF

Development of damage assesment of concrete compression member subjected to impact load using Bayesian probabilistic method (Bayesian 통계방법을 이용한 충격하중을 받는 콘크리트 압축부재의 손상평가의 개발)

  • Kim, Seung-Pyo;Yi, Jong-Gil;Yi, Na-Hyun;Kim, Jang-Ho;Lee, Kang-Won
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.161-162
    • /
    • 2010
  • In this study, the impact load on concrete compression member was considered to assess the quantitative damage index. The case study was carried out using the LS-DYNA, on explicit finite element analysis program. The parameters for the case study were impact load angle, slenderness ratio, etc. Using the analysis results, the performance based design method for impact load was developed using Bayesian probabilistic method, which can be applied to reinforced concrete column design for impact loads.

  • PDF

Characteristic of an insect-mimicking flapping device actuated by a piezoceramic actuator (압축하중을 받는 압전 작동기로 구동하는 곤충모방 날갯짓 기구의 특성)

  • Park, Hoon-Cheol;Quoc, Viet Nguyen;Byun, Do-Young;Goo, Nam-Seo;Yoon, Kwang-Joon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.36 no.11
    • /
    • pp.1063-1071
    • /
    • 2008
  • A piezoceramic unimoph actuator can produce a relatively larger actuation force and actuation displacement when a proper compressive load is applied during operation, because the compressive stress causes material nonlinear behavior in the piezoceramic layer and triggers mechanical buckling. In this paper, we examined effects of the actuator under compression on the flapping angle and aerodynamic force generation capability. Effects of wing shape and passive wing rotation angle on the aerodynamic force production were also investigated. The average vertical force acquired by a 2D CFD simulation for an artificial wing showed a good agreement with the measured one by the experiment.

Finite Element Analysis to Predict Design Loads of Circular Foundation (원형기초의 설계하중 예측을 위한 유안요소해석)

  • 김성득;김미룡
    • Geotechnical Engineering
    • /
    • v.5 no.1
    • /
    • pp.19-26
    • /
    • 1989
  • In this study, the finite element method for nonlinear problems is developed theroretically to see the design loads of foundation, when the circular plate resting on elasto-viscoplastic soil medium is loaded axisymmetrically. The paper shows that the plastic zone of soil medium is displayed at the near the edge of plate at the first place; when the plastic zone of soil medium is linked around central axis, the external load is termed by allowable load or design load, and then the contact pressure changes abruptly, in this case it is approved to be the risk of shear failure. The results of numerical analysis using the Mohr-Coulomb yield criterion, and experimental analysis for a appropriate safety factor are approximative, but numerical results are smaller than the value based on Terzaghi's theory.

  • PDF

Analysis of Laterally Loaded Piles Using Soil Resistance of Wedge Failure Mode (Wedge Failure Mode 형태의 반력을 이용한 수평재하 말뚝의 거동 분석)

  • Kim, Young-Ho;Jeong, Sang-Seom
    • Journal of the Korean Geotechnical Society
    • /
    • v.25 no.6
    • /
    • pp.59-72
    • /
    • 2009
  • The load distribution and deflection of offshore piles are investigated by lateral load-transfer curve method (p-y curve). Special attention is given to the soil-pile interaction and soil resistance of 3D wedge failure mode. A framework for determining a hyperbolic p-y curve is proposed based on theoretical analysis and experimental load test results. The methods for determining appropriate material parameters needed for constructing the proposed p-y curves are presented in this paper. Through comparisons with field case studies, it was found that the proposed method in the present study estimates reasonably the load transfer behavior of pile, and thus, the computed pile responses, such as bending moment and lateral displacement, agree well with the actual measured responses.

Load-Settlement Behavior of Rock-socketed Drilled Shafts by Bi-directional Pile Load Test (양방향 말뚝선단재하시험에 의한 암반근입 현장타설말뚝의 하중-침하거동 분석)

  • Seol, Hoon-Il;Jeong, Sang-Seom;Han, Keun-Taek;Kim, Jae-Young
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.11
    • /
    • pp.61-70
    • /
    • 2008
  • Load settlement behaviors and load transfer characteristics of rock-socketed pile subjected bi-directional load at pile tip were investigated using bi-directional pile load tests (BD PLT) performed on ten large-diameter drilled shafts at four sites. Based on test results, additional pile-toe displacement ($w_{bs}$) by coupled soil resistance was analyzed, and thus equivalent top loaded load-settlement curve of pile subjected bi-directional load was proposed by taking into account the coupled soil resistance. Through comparisons with field case studies, it is found that for test piles there exists effect of coupled soil resistance, which is represented by wbs, and thus an equivalent curve obtained by existing uncoupled methods can overestimate bearing capacity of piles by BD PLT. On the other hand, the analysis by the proposed method with soil coupling effect has a considerably larger settlement when compared with the results by uncoupled load transfer method and estimates reasonable load-settlement behaviors of test piles. In case of pile socketed in high strength rocks, however, effects of coupled soil resistance can be neglected.

Structural Static Test of Pylon for External Attachment Separation Load (외부장착물 분리하중에 대한 파일런 구조 정적시험)

  • Kim, Hyun-gi;Kim, Sungchan;Hong, Seung-ho;Choi, Hyun-kyung;Cho, Sang-hwan;Park, Hyung-bae
    • Journal of Aerospace System Engineering
    • /
    • v.16 no.1
    • /
    • pp.104-109
    • /
    • 2022
  • The bomb rack unit (BRU) installed inside the pylon serves to fix external attachments such as external fuel tank or external weapon, and also serves to separate external attachments in case of emergency. In particular, the load generated when the external attachment is separated from the BRU is called the punching load. In this study, we present the results of a structural static test performed to verify the structural integrity of the pylon under the BRU punching condition acting on it. In the structural static test report, we present the implementation method for the separation load of the external attachment and the test profile for the BRU punching load condition, and compared the error between the load input signal and the feed-back signal to determine the appropriateness of load control in each test. Furthermore, we compared the strain results obtained in the numerical analysis and structural test at the main positions of the specimen. As a result, it was shown that the load of the actuators were properly controlled within the allowable error range in each test, and the numerical analysis effectively predicted the test result. Finally, through structural static tests conducted by design limit load and design ultimate load, we verified that the aircraft pylon dealt with in this study has sufficient structural strength for external attachment separation condition.