• Title/Summary/Keyword: 적산기준

Search Result 92, Processing Time 0.023 seconds

Relationship between Glutamine Synthetase Activity and Nitrogen Content and Grain Yield in Wheat (밀의 Glutamine Synthetase 활성도와 질소함량 및 수량과의 관계)

  • 손상목;체맥 에버하르트
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.36 no.6
    • /
    • pp.545-553
    • /
    • 1991
  • To find out the basic data for the possibility of agricultural utilization for GSA (Glutamine Synthetase Activity), the effect of nitrogen on the GSA in wheat leaf discs, the variation of GSA after light treatment and the comparative activity of GS during preservation were studied. The result of this study suggested that GSA could play an important and direct regulatory role in the nitrogen assimilation by wheat. During the growth stage of wheat its integral activity was found to closely match the organic nitrogen content. GS may therefore be the rate limiting enzyme in inorganic N assimilation. Moreover, integral GSA was closely correlated with grain yield and grain nitrogen. GSA could be suitable to utilize as a parameter for super type selection and an indicator for optimum nitrogen fertilization. Throughout the experiment, the contents of NO; were increased by N fertilization so that the NO; content was not attributable to change in the level of GSA. At investigation during dark-light transition of culture, no change in the level of GSA was observed until after 8-14 hours in the light treatment. And the level of GSA in wheat leaf discs during preservation at refrigerated storage $(-20^{\circ}C)$ was stable until 12 weeks, when its leaf discs were sampled with liquid nitrogen.

  • PDF

Development and Application of Modified SWMM to Simulate Permeable Pavement and Infiltration Trench (투수성 포장과 침투 트렌치를 고려한 수정 SWMM의 개발 및 적용)

  • Lee, Jung-Min;Lee, Sang-Ho;Park, Jae-Hyeon;Lee, Kil-Seong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.326-330
    • /
    • 2007
  • 도시화 면적이 증가하면 불투수 면적이 증가하고 그에 따라 도시 하천의 평상시 유출이 감소한다. 도시유역의 평상시 수량을 회복시키는 방법으로는 침투 증진시설(투수성 포장, 침투 트렌치, 침투 측구 등)의 설치, 하수의 고도처리 후 방류 저수지에 의한 유황 개선, 지하철 용출수 활용 등이 있다. 우리나라의 경우에 일부 도시하천의 수량 감소가 심각한 상황에 이르고 있으며 이를 해결하고자 하는 노력이 최근에 나타나고 있다. 수량을 회복하려면 유량 평가를 위한 현장조사, 수량회복 계획, 재원의 반영, 수량회복 시설의 설치 및 관리의 순서로 단계별 사업이 수행되어야 한다. 계획 단계의 과업에서 필요한 사항은 여러 가지 수량 회복 방법의 영향을 정량 평가하는 것이다. 이에 핵심이 되는 것은 수량 회복 요소를 포함하거나 추가한 수문순환 평가 도구이다. 침투시설 중 투수성 포장과 침투 트렌치를 모의하도록 기존의 SWMM 모형을 수정하였다. 그 과정에서 증발량 처리와 지하수 출력기능에 대한 오류도 수정되었다. 수정 개발된 SWMM을 침투시설 모형실험 결과와 비교하여 수정된 프로그램의 적합성을 검증하였다. 투수성 포장과 침투 트렌치를 고려하여 수정된 프로그램을 안양천의 지류인 학의천 유역에 적용하여 침투시설의 효과를 분석하였다. 만일 학의천 불투수 면적의 10%를 투수성 포장으로 교체하면 하류 비산교 지점의 저수량$(Q_{275})$이 3 %, 갈수량$(Q_{355})$이 17 % 증가하는 것으로 분석되었다. 침투 트렌치의 경우 학의천 소유역 별로 100m 트렌치를 $5{\sim}10$개 시공할 경우 저수량은 약 1 %, 갈수량은 약9 %가 증가하였다. 수정 개발된 SWMM을 사용하면 침투 트렌치와 투수성 포장 이 도시 유역의 건기 수량회복에 미치는 영향을 분석할 수 있다.해 경보발령 이전에 한계수위를 넘어서는 경우(case_3)로서 분석되었다. 이러한 실패한 경보발령의 경우에 대한 원인분석 결과, 기존의 모형화를 통해 고려되지 못하였던 해안도시 홍수의 특성 중 총강우량에 대한 고려, 선행강우 여부 및 강우 지속시간, 지속시간 내 강우집중도 그리고 선정지점 내 조위의 영향과 유역내 합류식 하수관거 시스템의 영향 등 자연유역과는 다른 다소 복잡한 요소를 고려한 해안도시홍수 경보발령 기준에 대한 개선이 필요함을 확인할 수 있었다.이 좋다고 고찰된다. 6. 우리 나라의 현행 수도작기로 본 기온 및 일조조건은 수도의 분얼전기에 대해서는 호조건하에 놓여 있으나, 분얼후기인 7월 중ㆍ하순 경의 일조부족과 고온다습조건은 병해, 특히 도열병의 유발원인이 되고 있다. 7. 우리 나라의 현행수도작기로 본 전국각지의 수도의 출수기는 모두 일조시간이 적은 부적당한 시기에 처해 있다. 8. 출수후 40일간의 평균기온에 의한 적산온도 88$0^{\circ}C$의 출현기일은 수원에서 8월 23일이었고, 년간편차를 고려한 안전출수기일은 8월 19일로서 적산온도면에서는 관행 출수기일은 약간 늦다고 보았다. 9. 등열기의 평균기온에 의한 적산온도는 현행 수도작기로서는 최종한계시기에 놓여 있으며, 평균기온의 년간편차와 우리 나라의 최저기온이 낮은 점을 고려할 때, 현행출수기는 다소 늦은 것으로 보았다. 10. 생육단계별의 수도체내의 질소함량은 영양생장기의 질소함량이 과다하였으며, 출수 이후에 영양조락을 여하히 방지하느냐가 문제된다고 보았다. 11. 수리불안전답 및 천수답이 차지하는 전답면적의 비율은 차차 감소되고 있는데, 이와 전체 10a당 수량의 증가율과의 상관계수를 산출하였는데, 수리불안전답과의 상관계수 (4)는 +0.525였으며, 천수답과는 r=+0.832, 그리고 수리불안전답과 천수답을 합계한 것과의

  • PDF

A Study on the Improvement of Cost Calculation Model of Recycling Treatment Facility for Estimation of Construction Waste Disposal Fee (건설폐기물 처리대가 산정을 위한 중간처리시설의 비용산정 모델 개선에 관한 연구)

  • Chang-Hak, Kim;Jun-Yeong, Lee;Hyo-Jin, Kim
    • Land and Housing Review
    • /
    • v.14 no.1
    • /
    • pp.135-144
    • /
    • 2023
  • LH Corporation uses the construction waste disposal fee standard, of which the model was developed a long time ago. Therefore, this model is problematic because it needs to reflect waste treatment facilities' technological development and environmental conditions. In this study, the estimated manpower and costs required for the process operation of waste treatment facilities were analyzed, followed by the proposed estimation criteria. This improved standard model can be used as a cost calculation standard for the recycling and treatment of construction waste in public institutions. The study also suggests that an increase in waste treatment costs is needed.

A Simple Method Using a Topography Correction Coefficient for Estimating Daily Distribution of Solar Irradiance in Complex Terrain (지형보정계수를 이용한 복잡지형의 일 적산일사량 분포 추정)

  • Yun, Jin-I.
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.11 no.1
    • /
    • pp.13-18
    • /
    • 2009
  • Accurate solar radiation data are critical to evaluate major physiological responses of plants. For most upland crops and orchard plants growing in complex terrain, however, it is not easy for farmers or agronomists to access solar irradiance data. Here we suggest a simple method using a sun-slope geometry based topographical coefficient to estimate daily solar irradiance on any sloping surfaces from global solar radiation measured at a nearby weather station. An hourly solar irradiance ratio ($W_i$) between sloping and horizontal surface is defined as multiplication of the relative solar intensity($k_i$) and the slope irradiance ratio($r_i$) at an hourly interval. The $k_i$ is the ratio of hourly solar radiation to the 24 hour cumulative radiation on a horizontal surface under clear sky conditions. The $r_i$ is the ratio of clear sky radiation on a given slope to that on a horizontal reference. Daily coefficient for slope correction is simply the sum of $W_i$ on each date. We calculated daily solar irradiance at 8 side slope locations circumventing a cone-shaped parasitic volcano(c.a., 570m diameter for the bottom circle and 90m bottom-to-top height) by multiplying these coefficients to the global solar radiation measured horizontally. Comparison with the measured slope irradiance from April 2007 to March 2008 resulted in the root mean square error(RMSE) of $1.61MJ\;m^{-2}$ for the whole period but the RMSE for April to October(i.e., major cropping season in Korea) was much lower and satisfied the 5% error tolerance for radiation measurement. The RMSE was smallest in October regardless of slope aspect, and the aspect dependent variation of RMSE was greatest in November. Annual variation in RMSE was greatest on north and south facing slopes, followed by southwest, southeast, and northwest slopes in decreasing order. Once the coefficients are prepared, global solar radiation data from nearby stations can be easily converted to the solar irradiance map at landscape scales with the operational reliability in cropping season.

Study on Optimum Water Supply by Solar Radiation in Cut Rose(Rosa hybrida cv Cardinal) (일사비례제어에 의한 절화장미(Rosa hybrida cv Cardinal)의 급액량 구명)

  • Na, Taek-Sang;Kim, Jeung-Gun;Choi, Kyong-Ju;Gi, Gwang-Yeon;Yoo, Yong-Kweon
    • Journal of Bio-Environment Control
    • /
    • v.17 no.3
    • /
    • pp.215-220
    • /
    • 2008
  • This study was carried out to find optimum accumulative solar radiation in 'Carnidal' of Perlite Media. The pH was stable from 6.0 to 6.7 during cultivation. Electric conductivity by drainage was higher water than by supply water and electric conductivity was increased at later. Inorganic compound, such as phosphoric, kalium and magnesium were accumulated in crossed system. Especially, kalium and magnesium were highly accumulated. When solar radiation high, consumption of the amount of nutrient solution were increased. Sap flew was $273g{\cdot}hr^{-1}$ per hour from 10 : 30 to 11 : 00 AM. However there was no relation-ship between solar radiation and the mount of sap flew. When amount of solar radiation was $250W{\cdot}hr^{-1}$, cut rose 'Cardinal' nutrient consumption was 212.8 mL at nutrient supply of 50 mL. The yield of cut rose 'Cardinal' was 154.6 ea/10a in perlite media. In the cut rose 'Cardinal', nutrient solution was 50 mL as supplied at solar radiation of $200W{\cdot}hr^{-1}$ and nutrient solution was 30mL as supplied at solar radiation of $250W{\cdot}hr^{-1}$ at low solar radiation in perlite.

The Fact-finding and Analysis of the Environmental Management Cost in Construction Projects (건설공사의 환경관리비용 계상 및 운용 실태 분석)

  • Choi, Min-Soo;Kang, Woon-San
    • Korean Journal of Construction Engineering and Management
    • /
    • v.6 no.5 s.27
    • /
    • pp.186-192
    • /
    • 2005
  • The purpose of this study is to find the reality of environmental management cost in construction projects and to suggest some policies in order that owners appropriate the environmental management cost reasonably in the construction budget for reducing the environmental pollution at job sites. We surveyed the actual state of appropriating and expending the environmental management cost over 122 construction sites. According to the results of the survey, while the appropriated rate of the environmental management cost was 0.59% of the total construction cost. the expended rate reached at 0.94%. When examining the antipollution facilities which were operated in job sites, the investment for equipment against air-pollution such as tire washer, dust-proof device was relatively higher than other antipollution equipment. As the method appropriating the environmental management cost, we concluded that a quantity-per-unit costing method is more reasonable than appropriating at a fixed rate of total construction cost considering that there is little correlation between total construction cost and the environmental management cost. To do so, antipollution facilities that must be examined at a design or estimation stage of a construction project should be prescribed by the law. Moreover, referenced cost data for the quantity-per-unit costing should be prepared and officially published.

Water Pollution in Some Agricultural Areas along Nakdong River (낙동강 수계 주요 농업지대 소유역의 수질 오염)

  • Chung, Jong-Bae;Kim, Bok-Jin;Kim, Jeong-Kook
    • Korean Journal of Environmental Agriculture
    • /
    • v.16 no.2
    • /
    • pp.187-192
    • /
    • 1997
  • We carried out a survey on tributary streams in some agricultural areas along Nakdong River to evaluate the effects of agricultural practices on pollution of stream water and groundwater. General properties, nutrient materials and heavy metals in water samples were measured. General physicochemical properties of tributary stream waters were at levels favorable for agricultural water. Heavy metals, except Zn, were mostly not detected. Total-N contents were much higher than the criteria of agricultural water, and nitrate-N accounts for more than a half of total-N. Phosphorus contents were higher than the lower level of P for algae growth and the contents were high especially in summer. In ground waters which are used for irrigation, P were mostly at same levels as those in streams, and nitrate contents were higher than 10mg/L in some samples. In these results only those N and P contents in stream and ground waters higher than pollution criteria are problematic and they are traceable to agricultural nonpoint sources-fertilizers, livestock farms and sewage. Further researches are needed to evaluate contributions of each nonpoint source on stream water pollutions.

  • PDF

A Study on the Lighting Environment Standard for Museum Exhibition Halls, with a Focus on Color Temperature (박물관 전시 공간 조명 환경 기준 연구(I) - 색온도를 중심으로)

  • Lee, Sungeun;Roh, Hyunsook
    • Conservation Science in Museum
    • /
    • v.18
    • /
    • pp.65-76
    • /
    • 2017
  • Following advances in technology and with the growing need for renewable energy, fluorescent and halogen lamps are being replaced by LED lighting in museum systems. This paper researched the setting of standards for the diverse lighting systems in addition to the LED lighting that are expected to be introduced in museums in the future. Contrary to previous belief, LEDs were shown to only barely emit in the ultraviolet region, but the visible rays were confirmed to produce discoloration depending on illuminance-hours. When the color change by LED lamps at the color temperature of 2800K, or warm white, was compared with 5500K, or white, the emission spectrum analysis confirmed that the blue spike increased at a higher color temperature and caused more discoloration. This suggests that in addition to illumination, color temperature should be considered by including the emission spectrum when museums set lighting environment standards.

Analysis of the Outdoor Design Conditions for Greenhouse Heating and Cooling Systems in Korea (온실의 냉난방시스템 설계용 외부기상조건 분석)

  • Nam, Sang-Woon;Shin, Hyun-Ho
    • Journal of Bio-Environment Control
    • /
    • v.25 no.4
    • /
    • pp.308-319
    • /
    • 2016
  • In order to set the outdoor weather conditions to be applied to the design standard of the greenhouse heating and cooling system, outdoor air temperature and heating degree-hour for heating design, dry bulb temperature, wet bulb temperature and solar irradiance for cooling design were analyzed and presented. For every region in Korea, we used thirty years from 1981 to 2010 hourly weather data for analysis, which is the current standard of climatological normal provided by KMA. Since the use of standard weather data is limited, design weather conditions were obtained using the entire weather data for 30 years, and the average value of the entire data period was presented as a design standard. The design weather data with exceedance probability of 1, 2.5, and 5% were analyzed by the TAC method, and we presented the distribution map with exceedance probability of 1% for heating and 2.5% for cooling which are recommended by design standards. The changes of maximum heating load, seasonal heating load and maximum cooling load were examined by regions, exceedance probabilities, and setpoint temperatures. The proposed outdoor design conditions can be used not only directly for the greenhouse heating and cooling design, but also for the reinforcement of heating and cooling facilities and the establishment of energy saving measures. Recently, due to the climate change, sweltering heat in summer and abnormal temperature in winter are occurring frequently, so we need to analyze weather data periodically and revise the design standard at least every 10 years cycle.

Evaluation of Pheromone Lure of Grapholita molesta (Lpidoptera: Torticidae) and Forecasting Its Phenological Events in Suwon (복숭아순나방 성페로몬 미끼 평가 및 수원지역에서 주요 발생시기 예찰)

  • Kim Dong Soon;Boo Kyung Saeng;Jeon Heung Yong
    • Korean journal of applied entomology
    • /
    • v.43 no.4 s.137
    • /
    • pp.281-289
    • /
    • 2004
  • The sex pheromone blend (28-12AC : E8-12AC : Z8-12OH = 95 : 5 : 1) of oriental fruit moth, Grapholita molesta (Busck), was evaluated with reference to its male attractivity at different dosage and lure longevity of 1.0 mg in a field condition. Also, degree-days (DD) were calculated up to major phenological events of G. molesta using seasonal adult flights monitored by pheromone traps and egg population densities in early season in Suwon peach orchards. In the range of 0.1-4.0 mg dosage examined, G. molesta males caught in pheromone trap decreased with increasing total pheromone doses. The highest number of G. molesta males were attracted in traps baited with 0.1 mg-lure, and there were no significantly differences among 0.5 to 4.0 mg-lure. In longevity test with a 1.0 mg-lure, there was no difference in mean numbers of G. molesta males caught between traps with fresh-baited lures every 20d and field-lasted lures up to ${\approx}50d$ after trap installation, but thereafter more G. molesta males were attracted in the field-lasted lures than in the fresh-baited lures. Accumulated degree-days (DD) from January 1 to the first adult emergence (biofix) were 39DD at a lower threshold temperature $8.1^{\circ}C$. Degree-days from the biofix up to the 1st adult peak through 4th peak were 98DD, 620DD, 1233DD, and 1916DD, respectively. Required degree-days from the 1st adult peak to the 1st egg peak were 130DD, while the 2nd egg peak timing was simultaneous with the 2nd adult peak. Further, management strategies of G. molesta were discussed in peach orchards.