• 제목/요약/키워드: 저층부

Search Result 219, Processing Time 0.031 seconds

Productivity Analysis of Reinforced Concrete Works and Tower Crane Working Ratio for High-rise Apartment Buildings (초고층 공동주택 RC 공사의 생산성 및 타워크레인 가동율 분석)

  • Kwon, Jihun;Huh, Youngki
    • Korean Journal of Construction Engineering and Management
    • /
    • v.22 no.1
    • /
    • pp.55-62
    • /
    • 2021
  • The productivity of rebar-work and form-work was analyzed with data collected from an actual high-rise construction project, and the actual utilization rates of three tower cranes were also investigated. It was found that the average productivity of the form-work increased from 12.00~8.71(㎡/man·day) in the underground and above-ground/lower-floor to 11.94~20.73(㎡/man·day) in the standard floor. Comparing the productivity of core area to outer, the former was found to be about 11% higher. Moreover, the rebar-work productivity of the outer area(1.12 ton/man·day) was approximately 9.6% higher than that of the core area for the standard floor. The average utilization rates of three TC were surveyed to be about 63.49%, and it was revealed that rainy weather(6.1%), strong winds(6.1%), holidays(17.8%), TC lifting work(5.8%), and other failures and repairs(0.07%) were the causes of non-operation. These research results are expected to be beneficial data in planning and managing the process of high-rise RC construction works in the future.

A Study on Simplified Model of Double Angle Connections Subjected to Axial Loads (축방향 인장력을 받는 더블 앵글 접합부의 단순모형에 관한 연구)

  • Hong, Kap-Pyo;Yang, Jae-Guen;Lee, Soo-Kueon;Song, Byung-Ju
    • Journal of Korean Society of Steel Construction
    • /
    • v.12 no.1 s.44
    • /
    • pp.75-82
    • /
    • 2000
  • Recently, many studies on connections in steel structures have been performed. In practice, designers assume that the connection is a rigid- or pinned-one, however, actually the connection behaves as partially restrained one, neither fully restrained nor unrestrained. This paper concentrates on the behavior of double angle connections in the field of semi-rigid connections. The behavior of double angle connection. induced by abrupt axial tension load or by collapsed brace in medium or low rise building, is analyzed by 3D nonlinear finite element method using ABAQUS(ver 5.8). From the analytic results. a simplified model of double angle and a rotational stiffness at the corner of the angle are derived, which are fundamentally used for understanding the behavior of the double angle connection.

  • PDF

Characteristics of Cold Water Appeared in the Southwestern East Sea (동해 남서부해역에 출현하는 냉수 특성)

  • Lee, Moon-Ock;Otake, Shinya;Kim, JongKyu
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.26 no.3
    • /
    • pp.455-473
    • /
    • 2014
  • 하계 동해의 남서부해역에 냉수가 왜 그리고 어떠한 해양환경하에 출현하는가를 밝히기 위하여 현장조사, 위성자료의 분석 및 수치실험을 실시하였다. 이 해역에서 냉수는 비정상년의 경우는 정상년에 비해 보다 더 연안 가까이에서 출현하였고, 수온도 낮았다. 이것은 냉수가 비정상년에는 정상년에 비해 크게 발달하여 연안역으로 확장함을 의미하였다. 흐름장의 계산결과는 지형류적인 관점에서 수온의 관측결과를 잘 재현하였다. 한편, 정상년의 경우는, 북한한류(NKCW)가 쓰시마난류(TC)와 균형을 유지하면서 동해의 북서쪽에 머물고 있었다. 이에 반해, 비정상년의 경우는, 북한한류가 점차 남쪽으로 남하하여 동해 서부역의 대부분이 북한한류의 세력하에 놓였다. 그래서, 하계 동해 서부 연안역에서의 냉수 출현은 남쪽으로의 북한한류의 확장에 의한 부산물인 것으로 판단되었다. 울산 연안역에 대한 유동계산결과는 하계 남풍이 불 경우, 표층과 저층 사이에 흐름의 역전현상이 나타났다. 따라서, 하계 동해의 남서부 연안역, 특히 수심의 변화가 급한 방어진 부근에서 냉수의 용승이 일어날 수 있음을 시사하였다.

Development and Strength Evaluation of Beam-to-Column Connection Details in Weak Axis of H-shape Column (H형강 기둥의 약축에 대한 기둥-보 접합상세 개발 및 내력평가)

  • Kim, Sang Seup;Lee, Do Hyung;Ham, Jeong Tae;Kim, Kyu Suk
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.1 s.68
    • /
    • pp.169-180
    • /
    • 2004
  • One of the most influential elements is the moment resisting beam-to-column connection vis-a-vis the behavior and cost of multistory steel building frames. Majority of these connections are column flange connections attached to beam frames. This is called strong-axis connection. Another type of moment resisting connection commonly found in building frames is the web axis connection. In this type of connection, the beams are attached to the plane of the column web perpendicularly. It is called the weak-axis beam. and it tends to bend the column at its weak axis. In this study, some of the fundamental behaviors of beam-to-column connections were examined by changing the connection details as weil as comparing them with previous connection details. This study sought to develop the details in the beam-to-column connection in the weak axis for middle- and low-rise steel construction systems.

ENVIRONMENT IN THE OYSTER FARM AREA -Superficial Mud Characteristics Near Chungmu- (굴 양식장의 환경에 관한 연구 충무부근 양식장의 저질에 관하여)

  • CHO Chang Hwan;KIM Yong Sool
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.11 no.4
    • /
    • pp.243-247
    • /
    • 1978
  • COD and sulphide contents in the superficial mud in three oyster farms, one near Gajo-do in Chinhae Bay, the second near Eup-do in Koseong Bay and the third near Eogu in Keoje Bay, around the Chungmu area have been monthly determined for seven months from May through November in 1978. Bottom water was also checked for chlorophyll-a, dissolved oxygen, COD and sulphide. In general, large amounts of COD and sulphide in the superficial mud were found in the summer season, COD was 38.1 mg/g dry mud in the farm near Gajo-do, 32.3 mg/g near Eup-do and 25.1 mg/g in Eogu farm and sulphide was 0.313 mg/g dry mud, 0.517 mg/g and 0.132 mg/g respectively. COD and sulphide contents in the farms near Gajo-do and Eup-do were a little over the upper level of the eutrophic range, that is, 30 mg/g dry mud in COD and 0.3 mg/g dry mud in sulphide. It shows that the above two oyster farms were already eutrophicated. However, among three oyster farms no clear difference in bottom water was found.

  • PDF

Light Pollution of Outdoor Lighting in Coastal Area - Focused on Busan City - (해안가 야간경관조명의 빛공해 평가 - 부산시를 중심으로 -)

  • Kong, Hyo-Joo;Kim, Jeong-Tai
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.6
    • /
    • pp.18-26
    • /
    • 2010
  • Outdoor lighting has become a necessary essential part of society for safety and comfortable space. However, inappropriate outdoor lighting leads to energy waste and poor landscape. Outdoor lighting is a very important social element, which enables us to conduct various activities at night in a safe, efficient and comfort way. River Thames in UK, Venice in Italy and Sydney in Australia is a good example of the coastal area. This paper aims to evaluate the light pollution of outdoor lighting in coastal area in Busan city. The Radiant Imaging ProMetric-1400 was used to measure the luminance of Gwangalli Beach, Marine City and Haeundae Beach. Compare to the CIE recommendation level the luminance of the all outdoor lighting were about 2~20 times higher. Outdoor lighting of the building facade luminance level and color should be particularly limited.

Water Quality in Commercial Channel Catfish Ponds and Its Receiving Water Bodies (차넬메기 양어장의 수질과 주변 자연 하천수와의 관계)

  • SEOK Kyu-jin;BOYD C. E.
    • Journal of Aquaculture
    • /
    • v.6 no.3
    • /
    • pp.187-197
    • /
    • 1993
  • Studies related to water quality in catfish ponds were conducted on commercial catfish production ponds and compared with its receiving streams' water quality in central and west-central Alabama. The ponds were stocked with 10,000 fish/ha. The ponds were aerated nightly (0000-0600 hrs). Fish were fed to satiation at about the same time, six-days a week. In order to assess the pollutional strength of effluents from commercial channel catfish ponds, water samples were collected during each calender season from fall 1990 through summer 1991, and selected water quality variables were monitored. Mean values for water temperature, dissolved oxygen concentration, pH, settleable solids, total suspended soilds, volatile solids, total phosphorus, soluble reactive phosphate, biochemical oxygen demand, total ammonia nitrogen, nitrite, nitrate, and total Kjeldahl nitrogen were basically the same (P> 0.05) between samples taken from the surface and near the bottom. Concentrations of most water quality variables of catfish ponds were higher than those of receiving streams, and especially it had much higher average concentrations of nitrogen and phosphorus than streams.

  • PDF

Evaluation of Axial Strains of Reinforced Concrete Columns (철근콘크리트 기둥의 축방향 변형률 평가)

  • Lee, Jung-Yoon;Kim, Min-Ok;Kim, Hyung-Beom
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.1
    • /
    • pp.19-28
    • /
    • 2013
  • The longitudinal axial strain in the plastic hinge region of reinforced concrete (RC) columns influences on the structural behavior of RC structures subjected to reversed cyclic loading. This strain decreases the effective compressive strength of concrete and increases the lateral displacements between stories by causing the elongation of member length. This paper investigated the effects of the axial force on the elongation of a RC member by using a sectional analysis of RC members. The analytical and experimental results indicated that the axial force decreased the axial strain in the plastic hinge region of RC columns. In this study, a model was proposed to predict the axial strain of RC columns. The proposed model considering the effects of axial force ratio consisted of three path types ; Path 1-loading region, Path 2-unloading region, and Path 3-reversing cyclic loading region. The axal strains predicted by the proposed model were compared with the test results of RC columns with various axial force ratios, and agreed reasonably with the observed longitudinal strains.

Seismic Response of a High-Rise RC Bearing-Wall Structure with Irregularities of Weak Story and Torsion at Bottom Stories (저층부에 약층과 비틀림 비정형성을 가진 고층 비정형 RC벽식 구조물의 지진응답)

  • 이한선;고동우
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.6
    • /
    • pp.81-91
    • /
    • 2003
  • Recently, many high-rise reinforced concrete(RC) bearing-wall structures of multiple uses have been constructed, which have the irregularities of weak(or soft) story and torsion at the lower stories simultaneously. The study stated herein was performed to investigate seismic performance of such a high-rise RC structure through a series of shaking table tests of a 1: 12 model. Based on the observations of the test results, the conclusions are drawn as follows: 1) Accidental torsion due to the uncertainty on the properties of structure can be reasonably predicted by using the dynamic analysis than by using lateral force procedure. 2) The mode coupled by translation and torsion induced the overturning moments not only in the direction of excitations but also in the perpendicular direction: The axial forces in columns due to this transverse overturning moment cannot be adequately predicted using the existing mode analysis technique, and 3) the hysteretic curve and the strength diagram between base shear and torque(BST) clearly reveal the predominant mode of vibrations and the failure mode.

Influence of Stack Effect in High-Rise Buildings on Wind Effect in Jeju (Comparative Analysis of Seoul and Jeju) (제주지역 고층건축물에서의 바람의 영향이 굴뚝효과에 미치는 영향 분석 (서울과 제주지역간의 비교 분석))

  • Lim, Chae-Hyun
    • Fire Science and Engineering
    • /
    • v.29 no.6
    • /
    • pp.6-12
    • /
    • 2015
  • This study used CONTAM modeling to analyzed analyze the stack effect in high-rise buildings for the terrain and weather conditions of Seoul and Jeju. The differential pressure caused by the stack effect is a function of the indoor and outdoor temperature difference and the height of the vertical shaft. Jeju is considered more stable than Seoul, because it is warmer than Seoul in winter. The differential pressure in Jeju is about 60% that of Seoul in for the same height of buildings in winter. However, Jeju is an island and the neutral plane is raised by over 56% by strong winds, although there is less differential pressure caused by the stack effect in Jeju than in Seoul. Due to the raised neutral plane, the region and magnitude of negative pressure in the lower part is larger in Jeju than in Seoul.