• Title/Summary/Keyword: 저선량

Search Result 487, Processing Time 0.024 seconds

Measuring Absorbed Dose from Medical X-ray Equipment Using Optically Stimulated Luminescence Dots (광자극선량계의 저에너지 엑스선 특성비교)

  • Jung, Sook Jin;Jin, Gye Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.79-83
    • /
    • 2018
  • In this paper, we measured and analyzed the dose correction factor, absorbed dose linearity, peak voltage X-ray response, angular dependence. Exposure dose correction factor, absorbed dose linearity, and peak voltage linearity using the medical X-ray generator were all in accordance with IEC-62387-1 (2007). The reference to the dosimetry direction at 0, 30, and 60 degrees relative to baseline radiation exposure was -29% (${\pm}30^{\circ}$) and + 67% (${\pm}60^{\circ}$). The values measured at $30^{\circ}$ were -8% lower than the standard and -18% lower than the standard at $60^{\circ}$. Therefore, the effect of direction should be corrected when using OSL dot dosimeter.

Mutation Frequency of Tradescantia (BNL Clone 4430) Stamen Hairs Exposed to Low Dose of Gamma Ray in the KAERI ${\gamma}$-Field (저선량율의 감마선 조사에 의한 자주 달개비의 체세포 돌연변이 출현에 관한 연구)

  • Shin Han Kwon;Young Il Lee;Kyu Hoi Chung;Jeung Haing Oh
    • Nuclear Engineering and Technology
    • /
    • v.13 no.3
    • /
    • pp.161-167
    • /
    • 1981
  • For determination of mutation frequency induced by chronic irradiation of low dose gamma rays, Tradescarrfia clone 4430 was exposed to Co-60 ${\gamma}$ rays with different exposure rates from 3.6mR/day to 182R/day in or out of the Gamma Field at Kumkok Experiment Farm of KAERI. Somatic mutations based on pink mutant events of the stamen hair cells were clearly observed by the treatment. The pink mutant events were increased proportionally with increasing exposure rates of gamma ray except for relatively high dose rates of 105 R/day and 182 R/day, indicating saturation effect of mutation. The somatic pink mutations could be fairly detectable even in the low dose rate of 3.6mR/day. Therefore, this stamen hair system of Tradescantia clone 4430 seemed to be an reasonable test system for detecting mutability of low level irradiation. These results imply that artificial mutation induction in the fruit and ornamental trees could be expected in the ${\gamma}$-field.

  • PDF

Usefulness assessment of the Volumetric Modulated Arc Therapy technique for reducing low-dose areas during radiotherapy for patients with multiple metastatic cancers (다발성 전이암 환자의 방사선치료 시 저선량 영역 감소를 위한 용적조절 회전 방사선치료(Volumetric Modulated Arc Therapy) 기법의 유용성 평가)

  • Yun-won Choi;Dong-min Jeong;Se-young Kim;Ryeong-hwang Park;I-ji Kim;Yong-wan Cho;Yongjae Kwon;Byeol-nim Park;Gyeong-min Yoo;Ho-kyung Moon;Dong-jae Jang;Jae-young Lee;Dayoung Lim;Sang-gyu Lee;Jong-geol Baek
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.35
    • /
    • pp.23-31
    • /
    • 2023
  • Purpose: The purpose of this study is to evaluate the usefulness of Non-Treat Functionality Volumetric Modulated Arc Therapy(NTF-VMAT) and Treat Functionality VMAT(TF-VMAT) treatment plans in reducing the low-dose area during radiation therapy for patients with multiple metastatic cancers. Materials and Methods: The study was conducted on an Arccheck phantom, treatment planning target locations were set in pairs at intervals of 2 cm, 4 cm, and 6 cm on the X, Y, and Z axes. Based on these location settings, the volume of the low-dose area in NTF-VMAT and TF-VMAT was measured and compared. Results: The results of the study showed that, within a prescription dose range of 10% ~ 70%, the difference in low-dose area volumes across each axis was as follows: On the X-axis, there was a maximum difference of -47.6% and a minimum difference of -2.2%. On the Y-axis, there was a maximum difference of -17.5% and a minimum difference of -7.3%. The Z-axis showed a maximum difference of -39.7%, with the smallest difference being -6.8%. Conclusion: In radiation therapy for patients with multiple metastatic cancers, the TF-VMAT treatment plan was able to reduce the low-dose area by 10-40% compared to NTF-VMAT. This suggests that utilizing Treat Functionality, which includes the Island block technique, improves dose distribution and minimizes side effects, making it beneficial for the treatment of patients with multiple metastatic cancers.

  • PDF

Quality Characteristics of Low-Dose Electron Beam Irradiated-Imported Navel Orange during Storage at Room Temperature (20℃) (저선량 전자선 조사 수입 오렌지의 상온저장 중 품질 특성)

  • Cho, Yun-Jeong;Kim, Kyung-Hee;Yook, Hong-Sun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.44 no.3
    • /
    • pp.455-463
    • /
    • 2015
  • This study investigated the effects of low-dose electron beam irradiation treatment on the physicochemical and sensorial properties of imported navel oranges during storage at $20^{\circ}C$ for 12 days. The samples were irradiated at doses of 0.2, 0.4, 0.6, 0.8, and 1.0 kGy, after which changes in color value, hardness, Brix/acid ratio, total sugar contents, reducing sugar contents, vitamin C contents, and sensory evaluation were investigated. There were no significant differences between non-irradiated and irradiated samples in terms of color value, Brix/acid ratio, total sugar contents, total reducing sugar contents, and vitamin C contents. Hardness of irradiated samples significantly decreased in the early storage period in an irradiation dose-independent manner, and the difference between non-irradiated and irradiated samples decreased again at the end of storage. For the sensory evaluation, there was no significant difference between non-irradiated and irradiated samples up to 0.6 kGy, and all sensory item scores decreased at the end of the storage period regardless of irradiation. These results suggest that electron beam irradiation below 0.6 kGy does not affect physicochemical and sensory properties during storage at $20^{\circ}C$. Thus, electron beam irradiation up to 0.6 kGy applied to imported navel oranges is the optimum dose for minimizing quality changes and disinfestation treatment.

Analysis of Chromosomal Aberration Induced by Low Dose of Radiation (저선량방사선에 의한 염색체이상 빈도)

  • Yi, Chun-Ja;Ha, Sung-Whan
    • Radiation Oncology Journal
    • /
    • v.11 no.2
    • /
    • pp.233-240
    • /
    • 1993
  • Chromosomal aberration analysis, as a basis for biological radiation dosimetry, was performed for radiation dose ranges below 150 cGy. The yield, ratio of lymphocytes with dicentric and/or ring chromosomes, was 0, 0, 0.4, 0.5, 0.6, 0.8, 1.8, 5.5, 8.0, and $18.5\%$ for 0,5, 10, 15, 20, 25, 50, 75, 100 and 150 cGy, respectively. The Qdr, ratio of dicentric and ring chromosomes in total lymphocytes, was 0, 0, 0.004, 0.005, 0.006, 0.009, 0.018, 0.055, 0.084 and 0.207, respectively. The Qdr, ratio of dicentric and ring chromosomes in lymphocytes with aberration, was 1.0 for the radiation doses up to 75 cGy and 1.05 and 1.11 for 100 and 150 cGy, respectively. From the results, it seems possible to estimate radiation dose from Ydr when the exposure is 25 cGy or more. All the 5 radiation workers studied, with exposure much less than 1 mSv per month, had chromosomal aberrations. And acentric fragment pairs, in addition to dicentric and ring chromosomes, showed good dose response relationship and so may be useful for biological dosimetry for low dose radiation.

  • PDF

Comparison of CT Image Performance with or without Tin Filter based on Blind Image Quality Evaluation Method (블라인드 품질 평가 방법을 사용한 주석필터 사용 유무에 따른 CT 영상 특성 비교)

  • Shim, Jina;Lee, Youngjin
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.3
    • /
    • pp.301-306
    • /
    • 2021
  • The use of tin filters as a way to reduce the medical radiation in computed tomography (CT). However, due to the changed X-ray spectrum with the use of tin filters, disease diagnosis could be affected because it appears as images of different impressions from previous images. Therefore, this study evaluates the changes in images when using tin filter and high pitch in chest low-dose CT. In this study, images were acquired in groups of three for comparison. Group 1 did not apply to tin filter, and used the existing pitch 0.8. Group 2 used a tin filter, pitch 0.8, Group 3 used a tin filter, and pitch 2.5. To compare the image quality, the natural image quality evaluator (NIQE) and the blind/referenceless image quality evaluator (BRISQUE) were used among the blind quality evaluation factors depended on a no-reference basis. As a result, the NIQE values were low in the order of Group 1, Group 3, and Group 2. BRISQUE values were low in the order of Group 3, Group 2 and Group 1. This study confirms the superiority of images of tin filter and high pitch techniques in chest low-dose CT, which is considered to be a fundamental study for acquiring accurate images of patients with difficult breathing control.

Influence of the Low Dose ${\gamma}$-ray Radiation on the Old Seed Germination and Growth of Chinese Cabbage (묵은 배추종자의 발아와 생육에 미치는 저선량 ${\gamma}$선 효과)

  • 김재성;이영근;백명화;이영복;박영선
    • Korean Journal of Environmental Biology
    • /
    • v.17 no.1
    • /
    • pp.11-15
    • /
    • 1999
  • To investigate the stimulating effects of the low- dose radiation, the seeds of chinese cabbages (Brassica campestris L. cv. Hanyoreum and cv. Tropic emperor) were irradiated at the dose of 0.5 Gy~20 Gy with the ${\gamma}$-ray radition. In case of ‘Hanyoreum’cultivar, there were no significant promoting effects on the germination rate except the 0.5 Gy irradiated group. The increase in seedling height and fresh weight in 8 Gy and 12 Gy irradiated groups was 20% and 40%, respectively, which suggested the stimulating effect of the low-dose radiation on the early growth. In case of‘Tropic emperor’cultivar, the germination rate of 1 Gy irradiated group increased approximately 10% and the seedling height and fresh weight of 1 Gy and 12 Gy irradiated group in the greenhouse 20% on the average, and plant height and fresh weight of 0.5 Gy and 4 Gy irradiated group in the field increased 10% and 20% on the average, respectively.

  • PDF

Feasibility of Pediatric Low-Dose Facial CT Reconstructed with Filtered Back Projection Using Adequate Kernels (필터보정역투영과 적절한 커널을 이용한 소아 저선량 안면 컴퓨터단층촬영의 시행 가능성)

  • Hye Ji;Sun Kyoung You;Jeong Eun Lee;So Mi Lee;Hyun-Hae Cho;Joon Young Ohm
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.3
    • /
    • pp.669-679
    • /
    • 2022
  • Purpose To evaluate the feasibility of pediatric low-dose facial CT reconstructed with filtered back projection (FBP) using adequate kernels. Materials and Methods We retrospectively reviewed the clinical and imaging data of children aged < 10 years who underwent facial CT at our emergency department. The patients were divided into two groups: low-dose CT (LDCT; Group A, n = 73) with a fixed 80-kVp tube potential and automatic tube current modulation (ATCM) and standard-dose CT (SDCT; Group B, n = 40) with a fixed 120-kVp tube potential and ATCM. All images were reconstructed with FBP using bone and soft tissue kernels in Group A and only bone kernel in Group B. The groups were compared in terms of image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). Two radiologists subjectively scored the overall image quality of bony and soft tissue structures. The CT dose index volume and dose-length product were recorded. Results Image noise was higher in Group A than in Group B in bone kernel images (p < 0.001). Group A using a soft tissue kernel showed the highest SNR and CNR for all soft tissue structures (all p < 0.001). In the qualitative analysis of bony structures, Group A scores were found to be similar to or higher than Group B scores on comparing bone kernel images. In the qualitative analysis of soft tissue structures, there was no significant difference between Group A using a soft tissue kernel and Group B using a bone kernel with a soft tissue window setting (p > 0.05). Group A showed a 76.9% reduction in radiation dose compared to Group B (3.2 ± 0.2 mGy vs. 13.9 ± 1.5 mGy; p < 0.001). Conclusion The addition of a soft tissue kernel image to conventional CT reconstructed with FBP enables the use of pediatric low-dose facial CT protocol while maintaining image quality.

Selective Beam Shielding Method of Gamma-Knife Unit Using Various Plugging Patterns (다양한 Plugging 형태를 이용한 감마나이프의 선택적 빔 차폐 방법)

  • Jang Geon Ho;Lim Young Jin;Shin Dong Oh;Choi Doo Ho;Hong Seong Eon;Leem Won
    • Radiation Oncology Journal
    • /
    • v.11 no.2
    • /
    • pp.439-448
    • /
    • 1993
  • The B-type gamma knife unit was installed at Kyung-Hee University Hospital in March 1992. The selective beam plugging method can be used to reduce the low percentage isodose profiles of normal sensitive organ and to modify the isodose curves of treatment volume for better shaping of the target volume. For representing the changes of the low percentage isodose profiles, the variations of dose distribution for several cases were discussed in this paper. The film dosimetry was peformed for the evaluation of calculated isodose profiles predicted by KULA dose planning system. The results were verified by RFA-3 automatic densitometry. The clinical application of selective beam shielding method was peformed in 17 patients in 100 patients who have undergone gamma knife radiosurgery for a year. The calculated and the measured isodose profiles for the high percentage regions were well consistent with each other. When the target of pituitary tumor is macro-size, the selective beam shielding method is the most applicable method. When the target size, however, is small, the correct selection of the proper helmet size is very important. All patients were exposed almost about 3~12 Gy for brain stem, and 3~11.2 Gy for optic apparatus. It is recommended that the same or other plugging patterns with multiple isocenters should be used for protection of the radiosensitive normal structures with precise treatment of CNS lesions.

  • PDF