• Title/Summary/Keyword: 저교정

Search Result 223, Processing Time 0.026 seconds

Comparison between Accommodative Response Change on the Full Vision Correction and Low Vision Correction (완전교정과 저교정 상태에서 조절반응 변화량의 비교)

  • Bae, Sung-Hyun;Kwak, Ho-Weon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.1
    • /
    • pp.75-81
    • /
    • 2012
  • Purpose: The study tried to figure out accommodative changes by measuring accommodative response, appearing on the full vision correction and low vision correction, with both eyes open-view auto-refractometer (Nvision-K5001, Shin-nippon, Japan). Methods: It carried out objective and subjective refractions, targeting 79 college students (58 males and 21 females) aged between 20 and 30($21.14{\pm}2.00$), by measuring accommodative changes with fixation distance at 1.0 m for eyesight of 1.0 after full version correction. The distances of 5.0 m, 1.0 m, 0.50 m, 0.33 m and 0.25 m for eyesight of 0.8, 0.7 and 0.6 after low vision correction arbitrarily added plus lens were applied. Results: the shorter measure fixation distances were, the greater changes accommodative response showed a tendency in the state of both full vision correction and low vision correction(0.7). The state of full vision correction showed a greater change of accommodative response than that of low vision correction(0.7). Both right and left eyes showed low accommodative responses in the state of low vision correction(0.7) than that of full vision correction. As a result of analyzing accommodative response at an eyesight of 0.8, 0.7, and 0.6 after low vision correction, the poorer eyesight was the lower accommodative response. Conclusions: Low vision correction from a near distance is expected to avoid unnecessary accommodative response, make eyes relaxed and prevent accommodative function disorder.

평행평판형이온함을 이용한 전자선 흡수선량결정에 대한 연구

  • Ra, Jeong-Eun;Seo, Tae-Seok;Sin, Dong-O
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.149-152
    • /
    • 2004
  • 물 흡수선량 표준에 토대를 두고 있는 프로토콜에서는 저에너지 전자선의 경우 평행평판형이온함의 사용과 기준 선질 $^{60}$CO 감마선의 물 흡수선량 교정정수를 받은 원통형이온함을 사용하여 고에너지 전자선에서 평행평판형이온함을 교차교정하도록 권고하고 있다. 따라서 본 연구에서는 국제원자력기구의 프로토콜(IAEA TRS-398)에서 권고하고 있는 절차에 따라 저에너지 전자선에 대한 원통형이온함의 선질보정정수를 계산하고, 원통형이온함과 평행평판형이온함의 교정방법에 따른 흡수선량을 상호 비교하였다. 그 결과 전자선에너지 10 MeV 이상에서는 두 이온함간의 선량이 잘 일치하였으나 전자선에너지 6, 9 MeV에서 최대 3.3%까지 선량 차이를 보여 저에너지 전자선에서는 반드시 평형판판형이온함의 사용하여 선량측정 할 것을 권고한다. 교정방법 차이에 의한 평행평판형이온함의 선량은 서로 잘 일치하는 것으로 나타나 표준기관에서 직접 교정받은 $^{60}$Co 감마선의 물 흡수선량교정정수를 사용하여 전자선 물 흡수선량을 결정해도 큰 영향은 없을 듯하다. 또한 평행평판형이온함을 교차 교정하기 위한 전자선 에너지에 따른 흡수선량을 상호 비교한 결과 20MeV이외 12, 16 MeV의 전자선 에너지에서도 잘 일치하여 교차교정을 위한 전자선의 기준 선질에 대한 연구가 더 진행되어야 한다고 사료된다.

  • PDF

Comparison on Accommodative Response Changes in the Normal Group and Convergence Insufficiency (정상군과 폭주부족군에서 조절반응 변화량의 비교)

  • Kwak, Ho-Weon;Lee, Se-Hee;Kwak, Hyung-Bin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.1
    • /
    • pp.79-85
    • /
    • 2014
  • Purpose: This study investigated accommodative changes by measuring accommodative response, appearing on the normal and convergence insufficiency Group, by using both eyes open-view auto-refractometer (Nvision-K5001, shin-nippon, Japan). Methods: It carried out objective and subjective refractions, targeting 74 college students (54 males and 20 females) aged between 19 and 29 ($21.59{\pm}2.53$), spherical equivalent OD $-2.28{\pm}2.03$ D, OS $-2.18{\pm}2.01$ D, by measuring accommodative responses at full correction and under correction with plus lens +0.25, +0.50, +0.75 arbitrarily added. Results: In the group of normal and convergence insufficiency, the shorter fixation distances were, the greater accommodative lags showed. The group of convergence insufficiency showed the lesser changes of accommodative response than those of normal. But we found that the convergence insufficiency group had a little larger accommodative amplitude in the total fixation distances. The full correction of convergence insufficiency group and the under correction (+0.50 D) of normal were alike in the accommodative responses. We have also investigated that the correlation between accommodative responses and fixation distances was decreased steeply at the excessive low vision correction. Conclusions: Under correction (+0.50 D) in a near distance is expected to avoid unnecessary accommodative responses, make eyes relaxed and comfortable.

A Study on the Relationship between the Disc of Least Confusion and Corrected Vision of Astigmatism (난시안의 최소착락원과 교정시력과의 관계 연구)

  • Kim, Jung-Hee;Kim, In-Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.2
    • /
    • pp.51-57
    • /
    • 2008
  • Purpose: This study has been conducted to know how the size and position of the circle of least confusion has an influence on the vision for minimization of asthenopia when astigmatism is corrected and appropriated prescription to provided clear vision life. Methods: The method of the study has been worked on 68 students (136 eyes) of man and woman enrolled in university of Gyeong-gi-do aged 20 to 40, who have myopic astigmatism in order to know how the corrected vision changes according to the size and position of the circle of least confusion of astigmatism, the vision has been tested by giving the vision whose astigmatic power of 0.25D and 0.50D was just reduced, low correcting the astigmatic power into 0.50D, and at the same time inserting additionally spherical power -0.25D, all under a condition that the corrected vision after completely corrected astigmatism, and the axis of astigmatism was not changed. Results: The average vision was 1.047 when the astigmatic power was fully corrected, and in low correction of 0.25D, it was 0.914, and in low correction of 0.50, it was 0.772. It has been learned that the bigger the circle of least confusion was the bigger the range of vision reduction and the corrected vision in astigmatism has correlation with the size of the circle of least confusion. It has been examined that the average vision according to position of the circle of least confusion in astigmatism was 1.047 when the astigmatic power was completely corrected and focused on the retina with state of point, and in case that the astigmatic power was 0.50D of state of low correction, that is, the circle of least confusion was focused before retina, it was 0.828, and it was also 0.826 when the astigmatic power is low corrected with 0.50D and the circle of least confusion was focused on the retina. Explained briefly, It has been examined that in case that the state of low correction of the astigmatic power was same, the vision reduction was less in the image of the circle of least confusion focused upon the retina than in the image of its being focused before the retina. Conclusions: In case that the refractive power of cylindrical lens is reduced in test of wearability in astigmatism, there needs surely an adjustment of spherical lens that can place the circle of least confusion on the retina.

  • PDF

An Convergence Study on the Characteristics of the Dental Arch Development According to the Causes of Short Stature (저신장의 원인에 따른 치열궁 발육의 특성에 대한 융합연구)

  • Kang, Sohee;Son, Hwa-Kyung;Lee, Hee-Kyung
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.10
    • /
    • pp.89-96
    • /
    • 2021
  • This study is aimed to establish the direction of orthodontic treatment by analyzing the differences in the dental arch development due to the cause of short stature. Dental diagnostic tests were conducted on patients who were diagnosed with short stature. Idiopathic short statured children were classified through the paired sampling based on the age and gender of a short statured children with growth hormone shortage. Control groups were classified using same method as above, after selecting candidates with an arch length of less than 3mm and malocclusion. In conclusion, short statured children with growth hormone shortage or idiopathic had the higher rate of crowding and the small value of overbite compared to normal children. Therefore orthodontic treatment for short statured children needs treatment plan included evaluation for Arch length discrepancy to treat a crowding early. This study will provide important data for successful orthodontic treatment according to the characteristics of dental occlusion of short statured children.

A Study of a Correction Effect of Astigmatism using Spherical RGP Lens (근시성 난시안에서 구면 RGP 콘택트렌즈의 난시교정 효과)

  • Ju, Seok-Hui;Park, Hae-Jung;Shin, Chul-Gun;Shim, Hyun-Seog
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.2
    • /
    • pp.85-89
    • /
    • 2003
  • A tear lens formed by between back surface of spherical rigid gas permeable(RGP) contact lens and front surface of cornea shows an excellent correction effect of astigmatism. To study an effects of tear lens power using spherical RGP lens and therefore to utilize them in clinical procedures, we analyze a change of the total astigmatism, the cornea astigmatism, and the residual astigmatism, we derive the following conclusion. 1. Almost all refractive astigmatism below than 2.00D present fully corrected. Thereby resulting good visual acuity. Refractive astigmatism higher than 2.50D show under-corrected and apparent decrease of visual acuity if it is higher than 3.00D. 2. Amount of corneal astigmatism below than 2.50D show acceptable under-corrected while higher than 3.000 present unacceptable visual acuity. 3. An estimated residual astigmatism is not revealed as it is : but it is reduced when it incorporate to refractive astigmatism.

  • PDF

An Convergence Analysis of the Effect of Growth Hormone Deficiency on the Development of Teeth in short stature Children (성장호르몬결핍이 저신장 소아의 치아발육에 미치는 영향에 대한 융합 분석)

  • Son, Hwa-Kyung;Kang, So-Hee;Lee, Hee-Kyung
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.6
    • /
    • pp.39-47
    • /
    • 2021
  • The purpose of this study is to analyze the differences among short statured children with growth hormone deficiency, idiopathic, and normal children in order to find the effect of growth hormone deficiency on tooth developmental stage. We classified children diagnosed with short stature at the Pediatrics in Yeungnam University Hospital as subjects due to idiopathic and growth hormone deficiency. We analyzed the relationship between short stature and tooth development through the measuring of oral panorama and body index. Only the eruption of lateral incisors showed significant difference between short statured with growth hormone deficiency and idiopathic. Almost all tooth eruption was significantly delayed on short statured children with growth hormone deficiency compared to average group. In conclusion, short stature children with either growth hormone deficiency or idiopathic were affected not only in their somatic stature but also dental maturity. We look forward to this study presenting basic data for orthodontic therapy.

TheReviser: A Real-time Gesture Interface for a Document Polishing Application on the Projection Display (리바이저: 프로젝션 화면에서 문서교정을 위한 실시간 제스처 인터페이스)

  • Moon, Chae-Hyun;Kang, Hyun;Jung, Kee-Chul;Kim, Hang-Joon
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2003.11a
    • /
    • pp.601-604
    • /
    • 2003
  • 본 논문은 프로젝션 화면에서 사용자와 컴퓨터간의 상호작용을 위한 인터페이스인 리바이저를 제안한다. 리바이저는 프로젝션 화면에서 사용자의 손 제스처로 문서교정 부호를 인식하여 전자문서를 교정하는 인터페이스 시스템이다. 프로젝션 화면에서 이러한 제스처를 인식하려면 두 가지 문제가 있다. 하나는 다양한 빛의 변화와 복잡한 배경을 가지는 프로젝션 화면에서 전방물체를 검출하는 것이고, 다른 하나는 사용자의 연속적인 움직임에서 사용자의 의도를 알아내는 것이다. 전방물체를 검출하기 위해 프로젝터로 입력되는 영상과 카메라에 의해 캡쳐된 영상 사이의 색상정보를 사용한다. 이 색상정보는 다양한 빛의 변화와 복잡한 배경에서 전방물체를 구별할 수 있게 한다. 연속된 제스처를 인식하기 위해 적출과 인식이 포함된 새로운 제스처 적출방법을 제안한다. 실험결과 제안된 시스템에서 의미없는 움직임이 포함된 제스처 시퀀스에서 사용자 제스처의 인식률은 평균 93.22%로 만족할만한 결과를 보였다.

  • PDF

Examination of Refractive Correction and Accommodative Ability on Myopic Elementary School Children Wearing Glasses in Jinju City (진주지역 근시 안경착용 초등학생들의 굴절교정상태와 조절기능의 검사)

  • Nam, Woon-Go;Cho, Hyun Gug;Son, Jeong-Sik;Kwak, Ho-Weon;Moon, Byeong-Yeon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.1
    • /
    • pp.109-114
    • /
    • 2009
  • Purpose: This study was designed to investigate the condition of refractive correction on wearing glasses currently of elementary school children and their accommodative ability in Jinju city. Methods: Objective refraction, subjective refraction, amplitude of accommodation, negative and positive accommodation, accommodative facility, and dynamic retinoscopy were examined on 60 elemenary school children who aged 8~12 wearing myopiacorrected glasses. Results: The condition of refractive corrections was distributed that a case of full correction was 11.7%, a case of low correction with more than 0.8 visual acuity (VA) was 10%, and a case of low correction with less than 0.8 VA was 78.3% in wearing glasses currently. In results from examination of accommodative ability, the number of children having accommodative anomaly is 8 persons (13.3%), they were divided into accommodation insufficiency (4 persons), accommodative facility insufficiency (2 persons), accommodation excess (1 person), and accommodation insufficiency related to ocular function (1 person). Conclusions: It is demanded a periodic inspection of refractive correction to growing children, and the refractive correction after due consideration to accommodative ability is really needed.

  • PDF