• Title/Summary/Keyword: 재하실험

Search Result 712, Processing Time 0.022 seconds

Development of Short-span Precast Concrete Panels for Railway Bridge (철도교용 단지간 프리캐스트 콘크리트패널의 개발)

  • Seol, Dae-Ho;Lee, Kyoung-Chan;Kim, Ki-Hyun;Youn, Seok-Goo
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.5
    • /
    • pp.545-553
    • /
    • 2016
  • This paper presents experimental static test results of the precast concrete panels developed for short-span concrete bridge deck form. Different from LB-DECK, concrete rib attached to the bottom surface of concrete panel, and Top-bar is not used at the top surface of concrete panel. Number of concrete ribs and cross-section details of concrete rib are determined from the analytical results of parametric study considering the span length and the thickness of concrete bridge decks. Shear rebars are installed at the top surface of concrete panel for composite action between precast concrete panel and cast-in-place concrete. In order to evaluate the safety and the serviceability of the developed short-span concrete panel subjected to design load, static load test is conducted. Three test panels with span length of 1.6m are fabricated, and during the load test displacements, strains and cracks of test panels are measured and final failure modes are investigated. Serviceability of the test panels is evaluated based on the results of displacements, cracking load, and crack width at the design load level. Safety is also evaluated based on the comparison of the ultimate strength and the factored design load of test panels. Based on the test results, it is confirmed the short-span precast concrete panel satisfies the serviceability and safety regulated in design codes. In addition, the range of span length of concrete bridge decks for the short-span concrete panel is discussed.

An Experimental Study on the Thermal Property of Concrete under the Load Ratio Condition in Fire (화재시 하중재하에 따른 콘크리트의 열적특성에 관한 실험적 연구)

  • Kim, Hyung-Jun;Kim, Heung-Youl;Park, Kyung-Hun;Jung, Jae-Young;Kwan, Ki-Hyuk
    • Fire Science and Engineering
    • /
    • v.23 no.6
    • /
    • pp.66-74
    • /
    • 2009
  • When a fire occurs, the concrete structure's strength decreases by the increasing temperature under the fire in certain condition of constant load. And, the ratio of the axial force is changed by such decreased strength so that the structure is deformed. In this research, considering such case, we have conducted an actual fire test for the concrete lining with constant loading condition and various fire conditions. The specimen adopts the shape condition for small practical specimen defined by the EFNARC and we used 24MPa, 40MPa and 50MPa to analyze the thermal properties by the strength. The ratio of loading is imposed by a certain loading condition based on 20% and 40% of the sectional stress in concrete and MHC Fire is selected to realize the thermal impact of the concrete by rapid increasing temperature. As the result of the experiment, in the same ratio of loading, the 50MPa specimen shows more cracks and spalling as time goes on. The area damaged by the fire, according to the functional criteria of the concrete lining under the fire in ITA, does not satisfy with the standard in lack of 50mm depth from the heating surface at total 200mm lining.

Comparison of Flexural Tensile Strength according to the Presence of Notch and Fiber Content in Ultra High Performance Cementitious Composites (노치 유무와 섬유혼입률에 따른 UHPCC의 휨인장강도 비교)

  • Kang, Su-Tae
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.5
    • /
    • pp.525-533
    • /
    • 2012
  • In this study, bending tests were performed on beam specimens made of UHPCC with the fiber content range of 0~5 vol% to investigate the contribution of fiber content to first cracking strength and flexural tensile strength. Also, four-point bending tests for unnotched beam as well as three-point bending test for notched beam were performed to estimate the effect of the presence of notch on the strengths. The experiment result showed that the increase in fiber content made linear improvement in the flexural tensile strength; whereas first cracking strength was enhanced only when at least 1 vol% of fibers was incorporated. Comparison of the bending test results with and without notch showed that the notch effect varied with the fiber content. The increase in fiber content diminished the effect of stress concentration on the notch tip, reducing the difference in the strengths. With much higher fiber content, the effect of stress concentration almost disappeared and the defection on cracking plane or the size effect dominated the strengths, consequently resulting in higher strengths in the notched beams than the unnotched ones.

Investigation of Strain Behaviour around the Tip of Model Pile - Comparison between Laboratory Model Test and Numerical Analysis - (모형말뚝 선단부 주변의 변형률 거동 분석 - 실내모형실험과 수치해석 비교 -)

  • Lee, Yong Joo;Lee, Jung-Min
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.4C
    • /
    • pp.159-167
    • /
    • 2012
  • In this study, laboratory model pile-load test and finite element analysis were carried out to compare and analyze the strain behaviour around the model pile tip. In order to simulate the pile load, both the LCM(load control method)and DCM(displacement control method) were introduced to determine which one is appropriate for the FE simulation. In contrast to the previous simulation method, two interface elements around the model pile were used to consider the slip effect in the finite element analysis and its results were compared to the model test. Through this study it was found that the degree of non-associated flow was a dominant factor in terms of numerical solution convergence. In addition, an improved FE mesh was required to obtain the symmetric distribution of the maximum shear strain contour.

Characteristics of the Lateral Resistance of Pile according to the Lateral Loading Rate in Dense Sand (조밀한 모래지반에서 수평재하속도에 따른 말뚝의 수평저항 특성)

  • Gichun Kang;Hyejeong Park;Seong-kyu Yun;Jiseong Kim
    • Journal of the Korean Geosynthetics Society
    • /
    • v.22 no.3
    • /
    • pp.97-103
    • /
    • 2023
  • Recently, research on the lateral resistance of pile foundations has been actively conducted. In experimental studies on the lateral resistance of pile foundations, displacement control or load control methods are used. However, in the case of the displacement control method, the lateral resistance of the pile varies depending on the rate of the load applied to the pile. Therefore, this study seeks to determine the change in lateral resistance of pile foundations according to lateral loading rate through model experiments. The experimental results showed that the lateral resistance of the pile tended to decrease as the lateral loading rate applied to the pile head increased. In order to confirm this, a model experiment of the side change of the ground and pile according to the loading rate was additionally conducted. Through inverse analysis, the change in the depth of the rotation point according to the lateral loading rate was identified. Through the change in the lateral resistance of the pile foundation and the depth of the rotating point according to the lateral loading rate, it was proposed to test the loading rate within 1.5 mm/min during the lateral loading test of the pile.

Centrifuge Model Tests on Sliding Behavior of Cantilever Retaining Wall due to Surcharges (과재하중에 의한 역T형 옹벽의 활동거동에 관한 원심모형실험)

  • 유남재;유건선;이명욱;이종호
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.6
    • /
    • pp.153-160
    • /
    • 2000
  • 본 연구는 과제하중의 재하폭과 재하위치를 매개변수로 변화시켜 옹벽의 뒤채움재 상부 지표면에서 제한폭의 과재하중작용시 그의 활동거동에 관한 실험적, 수치적 해석적 연구이다. 중력 수준을 1g, 20g,40g로 변화시켜 수행한 원심모형실험을 통해 구한 기초의 극한지지력 및 하중-침하특성, 하중-옹벽수평변위특성에 관하여 조사연구 하였다. 또한, 옹벽의 활동으로 인한 지반파괴의 영향을 받기 시작하는기초의 재하위치를 추정하기 위하여 종래의 얕은 기초의 극한지지력 실험을 수행하여 이들 결과와 함께 비교하였다. 한편, 모형실험결과와 기존의 이론식을 수정보완한 해석 결과와 비교분석하였다.

  • PDF

Full-Scale Test on Precast Concrete Arch Bridge with Reinforced Joint and Backfill (보강된 이음부와 뒤채움을 적용한 조립식 프리캐스트 콘크리트 아치교량의 실물모형실험)

  • Chung, Chulhun;Joo, Sanghoon;Choi, Dongchan;Lee, Jongyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.2
    • /
    • pp.389-402
    • /
    • 2014
  • In this paper, the load test of full-scale precast concrete arch bridges considering reinforced joint and backfill was conducted. It is an improved method that the reinforced joint enhanced the structural performance of conventional masonry arch system which was proposed by previous researchers. The models of full-scale test are $10m(span){\times}3m$ (rise) and $10m(span){\times}2m$ (rise), which are 2 meters in width. The critical load position was shown at a third-span from the results of the pre-analysis. Based on the this results, the positions of load, measuring items and points were determined in experiments. As a result, the maximum load capacity of the specimen $10m{\times}2m$, a relatively small rise to span ratio (compared to the specimen $10m{\times}3m$), was higher than the specimen $10m{\times}3m$. It was evaluated that all the specimens have sufficient structural performance on the design load.

Experimental Study for Performance Evaluation of Structural Details of Girder-Abutment Joint in Integral Abutment Steel Bridge (일체식교대 강교량의 거더-교대 연결부 상세의 거동평가를 위한 실험적 연구)

  • Kim, Sang-Hyo;Yoon, Ji-Hyun;Choi, Woo-Jin;Kim, Jun-Hwan;Ahn, Jin-Hee
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.1
    • /
    • pp.61-72
    • /
    • 2011
  • In this study, the structural details of steel girder-abutment joints with shear connectors and tie bars were suggested to improve the rigid behavior and crack-resisting capacity of the joints in integral bridges. Experimental loading tests of steel girder-abutment joint specimens with the proposed and empirically constructed structural details were carried out, and the capacities and behavioral characteristics of the joints were evaluated through loading tests. Based on the results of the loading tests, it was estimated that all types of tested joints can be applied to the steel girder-abutment joints because they have sufficient stiffness and crack-resisting capacity under the required design and yield loads. According to the initial stiffness, crack propagations, and load-strain relationships, however, the joints with shear connectors and tie bars showed better structural behaviors compared to the empirically constructed joint.

Fire Resistance Behavior and Residual Capacity of Voided Slab Subjected to Fire According to Loading Condition (화재 시 하중 재하 조건에 따른 중공슬래브의 내화거동 및 잔존성능)

  • Choi, Hyun-Ki;Bae, Back-Il;Jung, Hyung-Suk;Choi, Chang-Sik;Choi, Joo-Hong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.1
    • /
    • pp.99-106
    • /
    • 2018
  • This study presents experimental investigation on the residual capacity of fire-damaged voided slabs according to loading conditions. In this study, two voided slab specimens were fabricated, and heated by ISO standard fire during 120 minutes with different loading conditions of presence of loading. These specimens were cooled down to room temperature, and the residual capacity of fire-damaged voided slabs was investigated. Based on test results, thermal distribution of voided slab through the depth of concrete sections is different by the loading conditions. The temperature of loaded specimen is rapidly elevated through the whole depth of concrete sections compared to the unloaded specimen. The residual strength of fire-damaged voided slab specimens are 60% and 66% of that of voided slab specimen without fire damage, and the residual stiffness of fire-damaged voided slab specimens decreases by 15%~23% of that of voided slab specimen without fire damage. In case of voided slab specimens subjected ISO standard fire, the loaded specimen shows the decrease of 10% in the residual strength and the decrease of 15% in the residual stiffness compared to the unloaded specimen. It seems to result from higher temperature of bottom reinforcements in the loaded specimen due to the cracks, and more extensive damage on concrete cover of reinforcements by spalling process according to load level.

Lateral Displacement and Ground Rising Movement with Soil Embankment (성토에 따른 지반의 측방변위와 지표면 융기량)

  • Jeong, Ji-Cheol;Shin, Bang-Woong;Oh, Se-Wook
    • Journal of the Korean GEO-environmental Society
    • /
    • v.5 no.2
    • /
    • pp.63-69
    • /
    • 2004
  • During and after the construction of embankment on soft ground, consolidation settlements and lateral displacements develop. But generally it's very difficult to predict the magnitude of lateral deformations and the correct distribution of lateral displacements with depth under the toe of embankment because the consolidation and the shear deformations of soft ground occur simultaneously. This study shows that later displacements of ground surface arise by embankment loading act on soft clay hight water contents in laboratory model testing. The results of model test are observed settlement of embankment, amount of maximum rising and displacement of ground surface with loading velocity. The formula were proposed to predict lateral movement by test series.

  • PDF