• Title/Summary/Keyword: 장축

Search Result 245, Processing Time 0.032 seconds

CLEANLINESS AND WALL MORPHOLOGY OF ROOT-END RETROGRADE CAVITY MADE BY ULTRASONIC DIAMOND INSTRUMENTS (초음파 다이아몬드 기구로 형성된 치근단 역충전 와동의 정화도 및 와벽형태)

  • Kim, Sung-Kyo;Lim, Choon-Hee;Kwon, Tae-Kyung
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.515-524
    • /
    • 1998
  • The purposes of this study were to observe the cavity wall morphology and to evaluate the degree of cavity cleanliness when root-end retrograde cavity preparation was done with ultrasonic diamond instruments. To observe the morphology of retrocavity and to evaluate the degree of cavity cleanliness. root-end resections were done on 20 palatal roots of extracted maxillary first molars after canal filling with gutta-percha. Retrocavities were prepared using either ultrasonic diamond instruments or stainless steel ones of medium power setting of level 6 ($Miniendo^{TM}$, EIE, CA, U.S.A.). Morphology of the cavity. degrees of the remaining canal debris and smear layer were evaluated under the scanning electron microscope. The results were as follows: Cavities prepared with ultrasonic diamond instruments showed scratched appearance of wall, while ultrasonic stainless steel preparation showed hatcheted appearance. Ultrasonic diamond instruments induced more smear layer than stainless steel ones did (p<0.01) in the cavity. However, there was no significant difference in canal debris (p>0.05).

  • PDF

Taxonomic study on the achene morphology of Korean Aster L. and its allied taxa (한국산 개미취속 및 근연 분류군의 열매 형태에 관한 분류학적 연구)

  • 정규영;정형진
    • Korean Journal of Plant Resources
    • /
    • v.13 no.3
    • /
    • pp.179-187
    • /
    • 2000
  • The achene morphology about 16 taxa of Korean Aster L. sensu lato were investigated to estimate its taxonomic values. The achene shapes were divided into four types; oblanceolate-oblong, obovate, oblong and obovate-oblong. The trichome shape on achene six types; uniseriate-conical, filiform, cylindrical, capitate type, long stalk capitate and globular. Their distributional features on upper part of achene four types; absent, sparse distribution of conical trichome, dense distribution of conical trichome and mixed distribution of conical and capitate trichome. The achene shapes and trichome characteristics were regarded to be a good characters in delimiting taxa because these did not differ among individuals in same taxa, but differ among the taxa. If Korean Aster L. sensu late were divided into Kalimeris, Heteropappus, Aster, Cymnaster, the capitate forms and mixed distribution of conical and capitate trichome were recognized as the good characters in delimting above section such as genus Kalimeris and Heteropappus, section Pseudocalimeris of Aster L. sensu stricto.

  • PDF

A Preliminary study of Biomechanical Behavior of High-Performance Polymer Post-Core System (고성능 폴리머 재질의 포스트-코어 시스템의 생역학적 거동에 대한 예비실험)

  • Lee, Ki-Sun;Kim, Jong-Eun;Kim, Jee-Hwan;Lee, Jeong-Yol;Shin, Sang-Wan
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.27 no.2
    • /
    • pp.75-81
    • /
    • 2018
  • The aim of this study was to evaluate the biomechanical behavior and long-term safety of high performance polymer PEKK as an intraradicular dental post-core material through comparative finite element analysis (FEA) with other conventional post-core materials. A 3D FEA model of a maxillary central incisor was constructed. A cyclic loading force of 50 N was applied at an angle of $45^{\circ}$ to the longitudinal axis of the tooth at the palatal surface of the crown. For comparison with traditionally used post-core materials, three materials (gold, fiberglass, and PEKK) were simulated to determine their post-core properties. PEKK, with a lower elastic modulus than root dentin, showed comparably high failure resistance and a more favorable stress distribution than conventional post-core material. However, the PEKK post-core system showed a higher probability of debonding and crown failure under long-term cyclic loading than the metal or fiberglass post-core systems.

A Case of Ascending Aortic Dissection with Severe Aortic Regurgitation Diagnosed by Echocardiography (심장초음파검사로 진단된 중증 대동맥판역류를 동반한 상행대동맥박리증 1예)

  • Kim, Sung-Hee;Lee, Ok-Kyoung
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.52 no.4
    • /
    • pp.425-429
    • /
    • 2020
  • Aortic dissection refers to the separation of the aorta into a true and false lumen as the medial membrane of the aorta is torn along the long axis due to a high aortic pressure when a minute rupture occurs in the aortic lining. The mortality rate is very high, and aortic dissection occurs 2~5 times more in men than women. The prevalent age range is 50~70 years old. In this case, the authors experienced a diagnosis of aortic dissection that occurred in a young woman in her 30s, which does not occur frequently. In the process of tracking severe aortic regurgitation, aortic valve prolapse was initially suspected. We report this case because aortic dissection could be diagnosed by observing the intimal flap of the ascending aorta in the process of confirming this suspected part.

A Study on the Measurement of Morphological properties of Coarse-grained Bottom Sediment using Image processing (이미지분석을 이용한 조립질 하상 토사의 형상학적 특성 측정 연구)

  • Kim, Dong-Ho;Kim, Sun-Sin;Hong, Jae-Seok;Ryu, Hong-Ryul;Hawng, Kyu-Nam
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.279-279
    • /
    • 2022
  • 최근 이미지분석 기술은 하드웨어 및 소프트웨어 기술의 급격한 발전으로 인해 의학, 생물학, 지리학, 재료공학 등에서 수많은 연구 분야에서 광범위하게 활용되고 있으며, 이미지분석은 다량의 토사에 대하여 입경을 포함한 형상학적 특성을 간편하게 정량화 할 수 있기 때문에 매우 효과적인 분석 방법으로 판단된다. 현재 모래의 입도분석 방법으로는 신뢰성 있는 체가름 시험법(KSF2302) 등이 있으나, 번거로운 처리과정과 많은 시간이 소요된다. 또한 입자형상은 입경이 세립 할수록 직접 측정이 어렵기 때문에, 최근에는 이미지 분석을 이용하는 방법이 시도되고 있다. 본 연구에서는 75㎛ 이상의 조립질 하상 토사 이미지를 취득하여, 입자들의 장·축단 길이, 면적, 둘레, 공칭직경 및 종횡비 등의 형상학적 특성인자를 자동으로 측정하는 프로그램 개발을 수행하였다. 프로그램은 이미지 분석에 특화된 라이브러리인 OpenCV(Open Source Computer Vision)를 적용하였다. 이미지 분석 절차는 크게 이미지 취득, 기하보정, 노이즈제거, 객체추출 및 형상인자 측정 단계로 구성되며, 이미지 취득시 패널의 하단에 Back light를 부착해 시료에 의해 발생되는 음영을 제거하였다. 기하보정은 원근변환(perspective transform)을 적용했으며, 노이즈 제거는 모폴로지 연산과 입자간의 중첩으로 인한 뭉침을 제거하기 위해 watershed 알고리즘을 적용하였다. 최종적으로 객체의 외곽선 추출하여 입자들의 다양한 정보(장축, 단축, 둘레, 면적, 공칭직경, 종횡비)를 산출하고, 분포형으로 제시하였다. 본 연구에서 제안하는 이미지분석을 적용한 토사의 형상학적 특성 측정 방법은 시간과 비용의 측면에서 보다 효율적으로 하상 토사에 대한 다양한 정보를 획득 할 수 있을 것으로 기대한다.

  • PDF

A study on sagittal root position of maxillary anterior teeth in Korean (한국인에서 상악 전치의 시상 치근 위치에 대한 연구)

  • Kong, Hyun-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.2
    • /
    • pp.88-94
    • /
    • 2020
  • Purpose: The purpose of this study was to analyze the sagittal root position of maxillary anterior teeth and report the frequency of each classification in Korean for immediate implant placement. Materials and Methods: A retrospective review of cone-beam computed tomography (cone-beam CT) images was conducted on 120 patients (60 male and 60 female) who fulfilled the inclusion criteria. After reorientation of the axis, cone-beam CT images were evaluated and the relationship of the sagittal root position (SRP) of the maxillary anterior teeth to its associated osseous housing was recorded. Class I, II, and III were classified respectively when the root was positioned on the labial, central, and palatal aspect of the alveolar bone. Class IV was the position that at least two thirds of the root is engaging both the labial and palatal cortical plates. Then, the angulation of the root axis and the alveolar bone axis was measured. Descriptive statistics and Kruskal-Wallis test were used to compare the angulation according to the root position and SRP class. Results: The frequency distribution of sagittal root position of maxillary anterior teeth indicated that 81.1%, 10.3%, 1.9%, and 6.7% were classified as Class I, II, III, and IV, respectively. The sagittal angulation at approximately 77.5% of central incisor, lateral incisor, and canine was < 20 degrees, but the angle at more than 42.7% of canine was ≥ 20 degrees. Within the class, the angulation was statistically significantly greater in Class I (16.19) compared to Class II (8.72) and Class III (9.93), and smaller in Class IV (3.79). Conclusion: Within the limitation of this study, a majority of the maxillary anterior roots were positioned close to the buccal cortical plate. However, some roots have very thin alveolar bone and sagittal angulation larger than 30 degrees. Therefore, cone-beam CT analyses of the sagittal root position and the sagittal angulation are recommended for the selection of the appropriate dental implant treatment approach.

Transarterial embolization of renal artery in dogs with experimental hydronephrosis (개의 실험적 수신증에 실시한 신동맥 색전술)

  • Chang, Dongwoo
    • Korean Journal of Veterinary Research
    • /
    • v.41 no.3
    • /
    • pp.437-445
    • /
    • 2001
  • This study was performed to validate the procedure of transarterial embolization of the renal artery (TAE-RA) using iohexol-ethanol solution in dogs with unilateral experimental hydronephrosis and to evaluate the embolized kidney using B-mode ultrasonography and selective angiography. Experimental hydronephrosis was induced by ligation of unilateral ureter in 12 dogs. Ultrasonographic findings revealed that size of the kidney was significantly increased at 9 days and 17 days and the length of renal cortex was significantly decreased at 17 days after ligation of the unilateral ureter and it was in accordance with dilation of ipsilateral renal pelvis. No significant change of BUN, creatinine, ALT, calcium, and phosphorus was found immediately after unilateral experimental hydronephrosis. Therefore, it was concluded that unilateral hydronephrosis was established in 12 dogs at 17 days after ligation of ureter. Renal artery embolization was performed using selective catheterization in the hydronephrotic kidney of seven dogs and EKG, $SpO_2$, body temperature, pulse, and respiratory rate were within normal ranges during procedures. Iohexol-ethanol solution was used as embolic material. Average ethanol dose for renal artery embolization was $1.94{\pm}1.24ml/kg$. There were no dogs expired after TAE-RA and no side effects associated with regurgitation of iohexol-ethanol solution. Revascularization of renal artery was not found in angiography in dogs treated by TAE-RA at immediately after TAE-RA and 14 days after TAE-RA. Ultrasonographically, the mean longitudinal length of the embolized kidney decreased significantly at 2 and 3 months after TAE-RA compared to that of contralateral normal kidney. In summary, marked shrinkage of the embolized kidney was observed in dogs with unilateral experimental hydronephrosis treated by TAE-RA with iohexol-ethanol and no adverse effects were observed throughout the observation period. It is concluded that TAE-RA with iohexol-ethanol solution is a viable alternative to nephrectomy in dogs with unilateral hydronephrosis.

  • PDF

Dynamic Morphologic Study of the Ulnar Nerve Around the Elbow Using Ultrasonography (초음파를 이용한 주관절 주위 척골 신경의 동적 형태학적 연구)

  • Jeon, In-Ho;Lee, Seong-Man;Choi, Jin-Won;Kim, Poong-Tak
    • Clinics in Shoulder and Elbow
    • /
    • v.10 no.1
    • /
    • pp.99-105
    • /
    • 2007
  • Purpose: The morphological study and dynamic stability of the ulnar nerve around the elbow joint was investigated in asymptomatic normal population using ultrasonography. The purpose of this study is to provide fundamental data for ultrasonographic diagnosis of ulnar neuropathy in cubital tunnel syndrome. Materials and Methods: Fifty cases of 25 healthy male volunteers, aged between 20 to 30 years, included in this study. High resolution 7.5 MHz linear probe was used to examine the ulnar nerve in axial and longitudinal views. In a longitudinal view, the course, position and the thickness of nerve were monitored, the diameter of ulnar nerve and dynamic stability at elbow flexion and extension were measured in an axial view at four different points; 1cm proximal to medial epicondyle, behind the medial epicondyle, entrance to Osborne ligament, and 1cm distal to Osborne ligament. Results: The short diameters of ulnar nerve at elbow extension at four anatomic points were 2.66 mm, 2.97 mm, 2.64 mm, and 2.69 mm and the long diameters were 4.61 mm, 4.56 mm, 4.36 mm, and 4.37 mm, which showed no significant change at each point. However, at elbow flexion, the short diameters were changed to 2.72 mm, 2.34 mm, 2.65 mm, and 2.41 mm and the long diameters into 4.49 mm, 5.40 mm, 4.16 mm, and 4.66 mm. At elbow flexion, significant morphologic change was observed in the medial epicondyle area, and the diameter of the ulnar nerve was shortest at the entrance of Osborne ligament both at flexion and extension. In terms of dynamic stability, nine subluxations and seven dislocations were observed. Conclusion: This study shows dynamic instability and a morphological change of long and short diameters of ulnar nerve at flexion and extension in a normal person, which should be considered in the ultrasonographic diagnosis of ulnar neuropathy.

A 3-dimensional finite element analysis of tapered internal connection implant system (Avana SS $III^{(R)}$) on different abutment connections (경사형 내부연결 임플란트 시스템 (SS $III^{(R)}$)에서 지대주 형태에 따른 응력분포의 3차원 유한요소 분석)

  • Lee, Hye-Sung;Kim, Myung-Rae;Park, Ji-Man;Kim, Sun-Jong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.3
    • /
    • pp.181-188
    • /
    • 2010
  • Purpose: The purpose of this study was to compare the stress distribution characteristics of four different abutment connections on SS-$III^{(R)}$ fixture under occlusal loading, using 3-dimensional finite element method. Materials and methods: The fixture of SS-$III^{(R)}$ (Osstem, Korea) with 4 mm diameter and 11.5 mm length and 4 types of abutments were analyzed; Solid, Com-Octa, ComOcta Gold, and Octa abutment. The models were placed in the area of first molar in the mandible. The 4 loading conditions were; (1) the vertical loading of 100 N on the central fossa, (2) the vertical loading of 100 N on the buccal cusp, (3) the $30^{\circ}$ inclined loading of 100 N to lingual side on the central fossa, and (4) the $30^{\circ}$ inclined loading of 100 N to the lingual side on the buccal cusp. The 3G.Author program was used, the von-Mises stress was calculated and the stress contours were plotted on each part of the implant systems and the surrounding bone structures. Results: Regardless of abutment types and loading conditions, higher stress concentration was observed at the cortical bone. In cancellous bone, the highest stress was observed at apical portion and the maximum stress occurred at the implant neck. The higher internal stress was observed in the fixtures than in the bone. The lowest stress was observed at loading condition 1 and the stress concentration was also lower than any other loading conditions. Conclusion: Within the limitation of the result of this study, it seems that the abutment connection type does not affect much on the stress distribution of bone structure.

Environmental Character and Catch Fluctuation of Set Net Ground in the Coastal Water of Hanlim in Cheju Island II. Fluctuation of Temperature, Salinity and Current (제주도 한림 연안 정치망 어장의 환경특성과 어획량 변동에 관한 연구 II. 수온 및 염분의 변동과 해수의 유동)

  • KIM Jun-Teck;JEONG Dong-Gun;RHO Hong-Kil
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.32 no.1
    • /
    • pp.98-104
    • /
    • 1999
  • To investigate the relationships between ocean environmental characteristics, the time-series data of temperature and salinity observed at a station near at Hanlim set net in 1995 and 1996 are analyzed, and the results are as follow ; 1. In hanlim set net, the diurnal range of temperature and salinity variation in summer is very large and the amplitude of short-period fluctuation of temperature and salinity is very large. That is, not only the water of the middle and bottom layers (low temperature and high salinity) but also the coalstal water (high temperature and low salinity) appears alternatively depending on the current direction 2. from the result of mooring for 22 days in Hanlim set net, the mean speed and direction of tidal current in neap tide were 9.1 cm/sec and south westward in ebb time, and 11.6 cm/sec and north or northeastward in flood time, respectively. The highest speed of the current was 15cm/sec in ebb time, and 22.6 cm/sec in flood time. The mean speed and direction of tidal current in spring tide were 10.4 cm/sec, and southwestward in ebb time, and 12.3 cm/sec, and north or northestward in flood time, respectively. The highest speed of the current was 19.4 cm/sec in ebb time, and 20 cm/sec in flood time respectively. The mean speed of the current in flood time was larger than that in ebb time. The velocity vector along the major axis of semidiurnal tide ($M_2$) component was 1.5 times larger than that of diurnal tide ($K_1$), The major directions of two compornants were northwestward and east-southeastward and residiual current were 3.25 cm/sec and northwestward-directed. Result of TGPS Buoy tracer for 3 days between Biyang-Do and Chgui-Do showed that the mean speed was 1.6 knot in ebb time and 1.3 knot in flood time. Direction of tidal was southwestward in ebb time and northeastward in flood time respectively. The maximum current speed was 4.8 knot in ebb time and 3.7 knot in flood time respectively. The mean speed and direction of tidal in of offshore were 1.7 knot and northwestward in flood time. The residual current appeared 0.3 knot northeastward.

  • PDF