• Title/Summary/Keyword: 잠재 $CO_2$ 감축량

Search Result 37, Processing Time 0.023 seconds

Analysis of Potential Greenhouse Gas Mitigation in Pohang Steel Industrial Complex (포항철강산업단지의 온실가스 잠재 감축량 분석)

  • Lee, Gwang Goo
    • Clean Technology
    • /
    • v.20 no.4
    • /
    • pp.439-448
    • /
    • 2014
  • The potential mitigation of greenhouse gas (GHG) is studied in the Pohang steel industrial complex (PHSIC). The total GHG emission in 2010 is estimated to be in the range from 4,174,000 to 4,574,000 $tCO_2-eq$ in PHSIC. To meet the target proposed by the government, it is needed to reduce 552,000 $tCO_2-eq$ at minium by 2020. To estimate the potential amount of GHG reduction, the technologies used in the voluntary carbon reduction projects are applied to 51 companies which are subject to GHG target management. From the viewpoint of technological availability and payback period, the fuel conversion and waste heat recovery have an advantage in the short term with a possibility to reduce 160,000 $tCO_2-eq$. In the mid term, the thermal technologies in steel and iron industry have the potential to cut 229,000 $tCO_2-eq$, while the electrical technologies have the potential of 125,000 $tCO_2-eq$ reduction. The gap between the target GHG mitigation and potential reduction using the short and mid term technologies is about 38,000 $tCO_2-eq$, which should be compensated by the fundamental process innovation and the implementation of the most cutting-edge technologies including renewable energy.

Estimation of Greenhouse Gas Emissions (GHG) Inventory and Reduction Plans for Low Carbon Green Campus in Daegu University (저탄소 그린캠퍼스 조성을 위한 온실가스 인벤토리 구축 및 감축잠재량 분석 - 대구대학교를 중심으로)

  • Jeong, YeongJin;Li, KaiChao;Kim, TaeOh;Hwang, InJo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.7
    • /
    • pp.506-513
    • /
    • 2014
  • The objective of this study is to establish the greenhouse gases (GHG) inventories and estimate the GHG reduction plans for Daegu University from 2009 to 2011. The annual average of GHG emissions in Daegu University was estimated to be 19,413 ton $CO_2$ eq during the study period. Emissions of electricity usage in Scope 2 most contributed about 55.4% of the total GHG emissions. Also, GHG emissions of Scope 2, Scope 1, and Scope 3 contributed 60.4%, 22.6%, and 17.0%, respectively. In order to estimate reduction potential of GHG, the Long-range Energy Alternatives Planning (LEAP) model was calculated using three scenarios such as sensor installation, LED replacement, and solar facility. The GHG will be reduced by 1,656 ton $CO_2$ eq for LED scenario, by 1,041 ton $CO_2$ eq for sensor scenario, and by 737 ton $CO_2$ eq for solar scenario compared to 2020 business as usual (BAU). Therefore, the total GHG emissions in 2020 apply three scenarios can be reduced by 15% compared with 2020 BAU.

Comparison of Potential CO2 Reduction and Marginal Abatement Costs across Sectors and Provinces in the Chinese Manufacturing Industries (중국 제조업 부문별 CO2 잠재감축량 및 한계저감비용 지역 간 비교 분석)

  • Jin, Yingmei;Lee, Myunghun
    • Environmental and Resource Economics Review
    • /
    • v.22 no.3
    • /
    • pp.459-479
    • /
    • 2013
  • To assess the feasibility of 'low carbon, sustainable growth' policy pursued of the Chinese government, this paper first measures technical efficiency, $CO_2$ shadow prices, and indirect Morishima elasticity of substitution between capital and energy for 24 of manufacturing sectors in Beijing and Chongqing, in which China launched pilot carbon emissions trading scheme, by estimating the input distance function. Based on these results, then the potential for $CO_2$ reduction, cost savings from emissions trading, and the effectiveness of capital investment in reducing $CO_2$ are compared across industries and provinces. In 2010, manufacturing industries in Beijing and Chongqing could potentially reduce the largest $CO_2$ emissions, amounting 5.2 and 17 million tons, respectively, by achieving 100% technical efficiency. While, on average, Chongqing has a comparative advantage in the cost savings from carbon trading over Beijing, Beijing is more likely to reduce $CO_2$ by expanding capital investment.

Greenhouse Gas Reduction Scenario from LEAP Model Application to a University Campus-For Hanyang University Ansan Campus (LEAP 모델 적용을 통한 대학단위 온실가스 감축안 도출 - 한양대학교 안산캠퍼스 대상으로)

  • Park, Hyo-Jeong;Jung, Hye-Jin;Yi, Seung-Muk;Park, Jae-Woo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.4
    • /
    • pp.280-287
    • /
    • 2012
  • The sources of greenhouse gases (GHG) at Hanyang University Ansan campus, including direct sources, indirect sources, and others, were investigated in order to establish the GHG inventory. Emission of GHG was calculated with the energy use from each source from 2007 and 2009. The indirect emission (56.7%) due to the electricity significantly contributed to total GHG emission. The scenario for the GHG reduction was designed for both campus administration and members. The reduction potential of GHG was simulated from 2007 to 2020 using Long-range Energy Alternatives Planning (LEAP) model. In case of GHG reduction scenario by campus administration, the GHG can be reduced by 63.34 ton $CO_{2eq}/yr$ for stationary combustion in the direct source, by 221.1 ton $CO_{2eq}/yr$ for mobile combustion in the direct source, and by 4,637.34 ton $CO_{2eq}/yr$ for lighting in the indirect source, compared to 2020 Business As Usual (BAU). In case of GHG reduction action scenario by campus members, the reduction potential of GHG was 1293.76 ton $CO_{2eq}/yr$. Overall, the total GHG emissions in 2020 by the both scenarios can be decreased by 24% compared to 2020 BAU.

A Study on the CO2 Reduction Potential by Means of Increased Efficiency of the Electricity (제조업 전력 사용 효율성 제고를 통한 온실가스(CO2) 감축 잠재량 추정에 관한 연구)

  • Min, Dong-Ki
    • Journal of Environmental Policy
    • /
    • v.9 no.3
    • /
    • pp.143-160
    • /
    • 2010
  • This paper estimate the $CO_2$ reduction potential that can be achieved by improving the technical efficiency of input factors in the manufacturing sector. Technical efficiency in each manufacturing firm was estimated using the DEA technique. Depending on the returns-to-scale assumption selected, average technical efficiency was estimated to be between 0.467 and 0.643. These estimates suggest that, when the efficiency of electricity consumption in the manufacturing sector is improved, the overall $CO_2$ emissions can be reduced by 17.1-25.5%. Recently, the Korean government has adopted a low-carbon-green-growth policy with the goal of reducing greenhouse gas emissions by 30% below the BAU level by year 2020. The analysis of the paper suggests that this goal can be achieved through improved efficiency of electricity consumption.

  • PDF

Analysis of Greenhouse Gas Reduction Potentials in a University using Bottom-up Model (상향식 모형을 이용한 대학의 온실가스 감축 잠재량 평가)

  • Yoo, Jung-Hwa;Park, Nyun-Bae;Jo, Mi-hyun;Jeon, Eui-Chan
    • Journal of Climate Change Research
    • /
    • v.3 no.3
    • /
    • pp.183-193
    • /
    • 2012
  • In this study, the S University's energy usage, greenhouse gas emissions situation and potential reduction amount were analyzed using a long-term energy analysis model, LEAP. In accordance with the VISION 2020 and university's own improvement plans, S University plans to complete a second campus through expansion constructions by 2020 and by allocating the needed land. Accordingly, increases in energy usage and greenhouse gas emissions seem inevitable. Hence, in this study, the calculations of potential reduction amount by 2020 were attempted through the use of LEAP model by categorizing the energy used based on usage types and by proposing usage typebased reduction methods. There were a total of 4 scenarios: a standard scenario that predicted the energy usage without any additional energy reduction activity; energy reduction scenario using LED light replacement; energy reduction scenario using high efficiency building equipment; and a scenario that combines these two energy reduction scenarios. As scenario-based results, it was ascertained that, through the scenario that had two other energy reduction scenarios combined, the 2020 greenhouse gas emissions amount would be 14,916 tons of $CO_2eq$, an increase of 43.7% compared to the 2010 greenhouse gas emissions amount. Put differently, it was possible to derive a result of about 23.7% reduction of the greenhouse gas emissions amount for S University's greenhouse gas emissions amount through energy reduction activities. In terms of energy reduction methods, changing into ultra-high efficiency building equipment would deliver the most amount of reduction.

Application of LEAP Model to Reduce GHG Emissions from Residential Sector (LEAP 모형을 이용한 가정 부문 온실가스 저감효과 분석)

  • Jo, Mi-hyun;Park, Nyun-Bae;Jeon, Eui-Chan
    • Journal of Climate Change Research
    • /
    • v.4 no.3
    • /
    • pp.211-219
    • /
    • 2013
  • This study uses the LEAP model that is a long-term energy analysis model to analyze reduction potential on S city residential sector energy usage for greenhouse gas emission. Energy consumption of S-si in 2009 is consumed most in residential and commerce sector by 39.1%. Also, energy and greenhouse gas emission of residential sector is expected to increase due to increase of households. Therefore, greenhouse gas reduction measures are desperately required in residential sector. For this study recognizes energy consumption of S-si residential sector and has established reduction measure of S-si residential sector greenhouse gas through literature search on domestic and foreign climate change correspondence policies. Also, construction of greenhouse gas reduction potential by reduction measures through LEAP model. There were a total of 5 reduction measures scenarios is Reference Scenario, LED Lighting, Energy Alternative, Green Life Practice, and Total Reduction Measure. As a result, greenhouse gas emission of Light Emitting Diode Lightings by 2020 was $1,181.0thousand\;tonCO_2eq$, decrease of 6.1% compared to the Reference Scenario and Greenhouse gas emission of Energy Alternative by 2020 was $1,171.6thousand\;tonCO_2eq$, decrease of 6.8% compared to the Reference Scenario. Greenhouse gas emission of Green Life Practice by 2020 was $1,128.7thousand\;tonCO_2eq$, decrease of 10.2% compared to the Reference Scenario. For Total Reduction Measures by 2020 emission was $966.9thousand\;tonCO_2eq$, decrease 23.1% compared to Reference Scenario.

국내 화력발전산업의 연료의 효율적 배분과 CO2 저검규모 추정

  • Lee, Myeong-Heon
    • Environmental and Resource Economics Review
    • /
    • v.21 no.1
    • /
    • pp.3-25
    • /
    • 2012
  • Generally speaking, firms, faced with a regulatory environment, are likely to use more or less inputs than optimal level due to allocative inefficiency of inputs. This paper, first, tests allocative efficiency of fuel inputs and calculates the divergence between the actual and optimal levels of each fuel input conditional on the optimal level of capital stock in Korean thermal power industry. Then, given that each fuel is efficiently allocated. potential reduction of $CO_2$ is estimated over the period 1987~2008. The null hypothesis of allocative efficiency with respect to all fuels is rejected, indicating that thermal power plants fail to attain cost minimization subject do market prices. Allocative efficiency between each pair of fuels is also tested; efficient uses of fuels relative to each other are all rejected. Empirical results indicate that coal and gas are used more and oil is used less than optimal level. On average, more than 10 million tons of $CO_2$ per year could be reduced by achieving allocative efficiency of fuels.

  • PDF

Estimating CO2 Emission Reduction of Non-capture CO2 Utilization (NCCU) Technology (NCCU(Non-Capture CO2 Utilization) 기술의 CO2 감축 잠재량 산정)

  • Lee, Ji Hyun;Lee, Dong Woog;Gyu, Jang Se;Kwak, No-Sang;Lee, In Young;Jang, Kyung Ryoung;Choi, Jong-shin;Shim, Jae-Goo
    • Korean Chemical Engineering Research
    • /
    • v.53 no.5
    • /
    • pp.590-596
    • /
    • 2015
  • Estimating potential of $CO_2$ emission reduction of non-capture $CO_2$ utilization (NCCU) technology was evaluated. NCCU is sodium bicarbonate production technology through the carbonation reaction of $CO_2$ contained in the flue gas. For the estimating the $CO_2$ emission reduction, process simulation using process simulator (PRO/II) based on a chemical plant which could handle $CO_2$ of 100 tons per day was performed, Also for the estimation of the indirect $CO_2$ reduction, the solvay process which is a conventional technology for the production of sodium carbonate/sodium bicarbonate, was studied. The results of the analysis showed that in case of the solvay process, overall $CO_2$ emission was estimated as 48,862 ton per year based on the energy consumption for the production of $NaHCO_3$ ($7.4GJ/tNaHCO_3$). While for the NCCU technology, the direct $CO_2$ reduction through the $CO_2$ carbonation was estimated as 36,500 ton per year and the indirect $CO_2$ reduction through the lower energy consumption was 46,885 ton per year which lead to 83,385 ton per year in total. From these results, it could be concluded that sodium bicarbonate production technology through the carbonation reaction of $CO_2$ contained in the flue was energy efficient and could be one of the promising technology for the low $CO_2$ emission technology.

Estimation of the Shadow Price of Carbon Dioxide Emissions, the Potential Reduction, and Substitution Possibility for fuels in the Chinese Fossil-fueled Power Generation Sector (중국 화력발전산업의 CO2 암묵가격 및 잠재감축량, 연료에 대한 대체가능성 분석)

  • Jin, Yingmei;Lee, Myunghun
    • Environmental and Resource Economics Review
    • /
    • v.22 no.1
    • /
    • pp.77-98
    • /
    • 2013
  • China, the world's largest $CO_2$ producer, is likely to be obligated to reduce greenhouse gas emissions under the post-Kyoto protocol. This paper estimates a Shephard input distance function for the Chinese fossil-fueled power generation sector to measure the shadow price of $CO_2$ emissions, technical efficiency, and indirect Morishima elasticities of substitution between inputs. Empirical results show that, on average, it costs approximately 3.2 US dollars per year to reduce $CO_2$ emissions by one ton over the period 1981-2009. This finding indicates that Chinese power sector is expected to benefit from selling emission permits to other countries such as Korea and Japan, given that our estimate for China is lower than the ones previous literatures estimated for the power sector in these countries. The maximum attainable average $CO_2$ reduction potential amounts to approximately 25 million tons per year by improving technical efficiency. Capital is substitutable with both coal and oil and capital is relatively more readily substituted for these fuels.