• Title/Summary/Keyword: 자장분포

Search Result 83, Processing Time 0.033 seconds

Characteristic of Magnetic Field Distribution of 100hp Class High Temperature Superconducting motor (100hp급 고온초전도 모터의 자장분포특성)

  • 이정종;조영식;주진홍;홍정표;권영길
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.312-314
    • /
    • 2002
  • Magnetic circuit design of HTS (High Temperature Superconducting) motor is important to achieve the power at a given load condition, and it is essential to the thermal design for HTS motor rotors. To determine the result of thermal design, the magnetic field distribution has to be known exactly. On the basis of the 2 dimensional magnetic field analysis, the magnetic field distributions due to several cases are calculated by using Biot-Savart equation and magnetic image method. And the I$_{c}$ of HTS field coil was calculated by using I$_{c}$-B(equation omitted) curve and 3D FEA(Finite Element Analysis).is).

  • PDF

Harmonic Analysis for Development and Shimming of High Precision and Uniform Magnetic Field in Solenoid System (고정밀.균등자장의 솔레노이드 시스템 개발 및 보정을 위한 고조파 수치해석)

  • Kim, In-Ho;Lee, Se-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.961-962
    • /
    • 2011
  • 핵자기공명(NMR, Nuclear Magnetic Resonance) 장치의 성능은 자계의 세기와 균일한 정도에 따라 좌우된다. 그리고 균일도를 높이기 위해 자성체를 더하는 작업을 보정(Shimming)이라고 하며 이를 위해서는 기존에 분포하는 자계와 더해지는 자성체에 의해 발생하는 자계의 세기를 부분별로 정확하고 정밀하게 계산하는 것이 요구된다. 하지만 이를 비오-사바르의 법칙(해석해)으로 계산하는 것은 너무 복잡하고 그 대안으로 사용하는 유한요소법 기반의 수치해석 프로그램은 유한요소법 자체가 가진 오차로 인해 정확한 결과를 얻기 어렵다. 따라서 이를 해결하기 위해 가렛(M. W. Garrett)이 제안한 고조파 해석을 Real*16이 적용된 포트란을 사용하여 구하고 그 결과를 해석해의 값 및 수치해석 프로그램 결과와 비교하였다. 이를 통해 자계를 계산함에 있어서 고조파 해석의 타당성을 확인하였다.

  • PDF

Collimation of cesium atomic beam using laser light pressure (레이저 광압을 이용한 세슘 원자빔의 집속)

  • 박상언
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.4
    • /
    • pp.227-231
    • /
    • 2000
  • Thermal cesium atomic beam was collimated by transversely cooling of atoms, for which circularly polarized ($\sigma^+$ and $\sigma^-$ polarized) laser light was illuminated to the atomic beam from two perpendicular directions. As a result, the temperature corresponding to the transverse velocity component could be decreased from 430 mK to 60 11K. In addition, the spatial atomic distribution was observed according to the power difference of the two laser beams and the magnetic field applied, and the result was qualitatively coincided with the calculation result by the Doppler cooling theory. heory.

  • PDF

KSTAR NBI 이온원의 수소 및 헬륨 개스에서의 방전특성

  • 김계령;박선기;오병훈;최병호
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.224-224
    • /
    • 1999
  • KSTAR 토카막의 플라즈마 가열을 위한 NBI 장치의 대전류 이온원 방전 특성을 수소와 헬륨 개스를 사용하여 조사하였다. NBI 이온원은 빔 방향과 반대로 가속되는 전자들을 저지하는 전자덤프(electron dump), 병렬로 연결된 32개의 텅스텐 필라멘트(직경 1.5nn0, 영구자석(Nd-Fe)에 의해 만들어지는 강한 cusp 자장으로 둘러싸인 플라즈마 방전실 및 120kV의 에너지를 인가하는 가속부로 이루어지는데, 최대 빔 전류 65A에서 300초의 장시간 운전을 목표로 하고 있다. 수소와 헬륨 개스 분위기에서 안정된 플라즈마를 얻을 수 있는 필라멘트 전류의 파형을 각각 구하고, 기체압력(0.01~0.4 mbar) 및 아크 전류(100~1200A에)에 따른 플라즈마 파라메타 값들을 직경 1mm의 Langmuir probe를 이용하여 측정하였다. 또한 이온원 운전에 중요한 파라메타인 방전실 내의 플라즈마 밀도 분포와 장시간 운전 가능성에 대한 조사도 수행하였다.

  • PDF

KSTAR 전자 사이클로트로 방출(ECE) 진단계

  • Jeong, Seung-Ho;Lee, Gyu-Dong;Kogi, Y.;Kawahata, K.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.411-411
    • /
    • 2011
  • KSTAR 토카막 플라즈마의 전자온도 측정을 위한 전자 사이클로트론 방출(ECE) 진단계가 완성되어 KSTAR 3차 운전기간 동안 전자온도를 측정하였다. ECE 진단계는 2단의 헤테로다인 수신기 2개와 75채널의 RF 검출기 그리고 비디오 증폭기로 이루어져있다. 2개의 헤테로다인 수신기의 주파수 범위는 각각 110 GHz~162 GHz, 164 GHz~196 GHz 이며 163 GHz multiplexer에 의해 ECE power를 나눠갖는다. 각 채널 사이의 주파수 간격은 1 GHz이며 토로이달 자장을 2.5T로 운전한다면 플라즈마 반경방향의 모든 위치에서 측정이 가능하다. 또한 시간분해능도 100 kHz로 우수하여 반경방향의 전자온도분포의 시간 변화를 측정할 수 있다. 이 포스터에서는 2010년 KSTAR 실험동안 반경위치에 대한 전자온도를 측정과 sawtooth, ELM 등 MHD 현상 관측 결과에 대해 발표하였다. 그리고 중성빔(NB) 가열을 하는 동안 나타난 H-mode 때 전자온도의 변화도 살펴보았다.

  • PDF

Profiles of electric and magnetic fields in the vicinity of 22.9[kV] Distribution Line (22.9[kV] 배전선로 주변의 전장과 자장의 분포)

  • Lee, Bok-H.;Gil, Hyoung-J.;Ahn, Chang-H.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1653-1655
    • /
    • 1998
  • In this paper, measurement and analysis of ELF electric and magnetic fields in the vicinity of 22.9[kV] distribution line have been performed. The height of measuring point from the earth's surface was 1[m], and the distance between the device and the operator was more than 3[m]. The experiments have been carried out by lateral profile, and we have made use of FIELDS program for the sake of comparision the experimental data with the theoretical value. Electric and magnetic fields intensity were strong under a distribution line, and were inversely proportional to lateral distance. The profiles of electric field were M shape and those of magnetic field were $\cap$ shape. Electric and magnetic fields intensity were increased with increasing the measurement height.

  • PDF

Profiles of Electric and Magnetic Fields around 22.9[kV] Distribution Lines (22.9[kV] 배전선로 주변의 전장과 자장의 분포)

  • ;李福熙
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.2
    • /
    • pp.178-178
    • /
    • 1999
  • In recent years, the electromagnetic environments are varied with the increase of power consumption and the spread of household electric appliances. Most of the interests to date have concentrated in the area of human health effects associated with exposure to power frequency electric and magnetic fields, and thus the precise measurement and analysis are required. In this paper, the measurements and analysis of the extremely low frequency(ELF) electric and magnetic fields produced by actual 22.9[kV] distribution lines were performed. The experiments have been carried out by lateral profile, and the theoretical analyses were made by use of FIELDS program for the sate of comparison with the experimental data. Electric and magnetic field intensity were strong under power distribution lines, and were inversely proportional to lateral distance. The profiles of electric and magnetic fields were M and ∩ shapes, respectively, and the measured data were good in agreement with the theoretical results. Both the electric and magnetic field intensity were increased with increasing the measurement height.

The study of Hanbit magnetic mirror plasma diagnostics and characteristics by RF compensation triple probe (RF보상 삼중탐침을 이용한 한빛자기거울플라즈마의 진단과 특성 연구)

  • Choi, Ik-Jin;Park, Nam-Suk;Chung, Chin-Wook;Lee, S.G.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1529-1530
    • /
    • 2006
  • 현재 한빛 플라즈마에서 운영되고 있는 전자기 진단장치는 정전탐침, 자장탐침 및 반자성루프 둥이 있다. 정전탐침은 고정식, 이동식, 고속주사방식 세 종류의 진단장치가 개발되어 실험에 이용되어 왔는데 비교적 쉽게 많은 종류의 probe와 다양한 probe tip을 구성할 수 있기 때문에 한빛 장치에서 axial 및 azimuthal 방향으로 전자 온도/밀도 및 그들의 분포를 측정하고 있다. 단일탐침에서 사용되던 RF 보상기술을 삼중탐침에서도 적용시켜 RF 보상 삼중탐침을 개발하였다. 기존의 삼중탐침의 경우에는 DC에 대해서는 높은 임피던스로 외부에 부유되어 있지만 RF의 경우에는 외부와 부유되지 않고 낮음 임피던스로 연결되어있는 경우가 많았다. 하지만 RF보상 삼중탐침의 경우에는 RF의 경우에도 충분히 큰 임피던스로 부유되어 있다. 따라서 보다 왜곡되지 않은 측정을 할 수 있다. RF보상 삼중탐침을 이용하여 한빛 Mirror 플라즈마에서 axial 방향으로 Plasma 변수들의 변화를 관찰하면서 기존의 탐침에서 볼 수 얼던 여러 특성을 관찰할 수 있었다.

  • PDF

Design and Comparison of Superconducting Magnets with Circular Coil Elements for Magnetic Resonance Imaging (원형무코일로 구성된 MRI용 초전도 자석의 설계와 비교)

  • Kim, Yong-Gwon;Hyun, Jung-Ho;Seo, Jeung-Hoon;Kim, Hyug-Gi;Oh, Chang-Hyun
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.6
    • /
    • pp.57-62
    • /
    • 2011
  • This paper proposed a method which is the three types of magnet model for improving field inhomogeneity of superconducting magnet. The length of coil wire was compared for the optimized current pattern using minimum power methods and field inhomogeneity under the specific simulation condition in case of same magnet field strength about each magnet type field inhomogeneity. Length of wire and field inhomogeneity were compared under the same condition(18 target points, 20cm DSV). According to the simulation results, the smaller target points can reduce the wire length but it can not improve the field inhomogeneity. Length of wire and low field inhomogeneity can not improve in same time. However, small DSV and reducing target points can overcome the these problem. And to conclude, if it processes shimming as reducing target points in case of magnet model which is open to space, about the size of same imaging region it needs a lot of current values(or the length of wire) and decreases field homogeneity but it is useful to get small ROI.

A Study on Magnetoresistance Uniformity of NiFE/CoFe/AlO/CoFe/Ta TMR Devices Prepared by ICP Sputtering (ICP 스퍼터를 이용한 NiFe/CoFe/AlO/CoFe/Ta TMR 소자 제작에 있어서의 자기저항 균일성 연구)

  • 이영민;송오성
    • Journal of the Korean Magnetics Society
    • /
    • v.11 no.5
    • /
    • pp.189-195
    • /
    • 2001
  • We prepared TMR junctions of NiFe(170 )/CoFe(48 )/Al(13 )-O/CoFe(500 )/Ta(50 ) structure on 2.5$\times$2.5 $\textrm{cm}^2$ area Si/SiO$_2$ substrates in order to investigate the uniformity of magnetoresistance(MR) value using a ICP magnetron sputter. Each layer was deposited by the ICP magnetron sputter and tunnel barrier was formed by the plasma oxidation method. We measured MR ratio and resistance of TMR devices with four-terminal probe system by applying external magnetic field. Although we used ICP sputter which is known as superior to make uniform films, the standard variation of MR ratio was 2.72. The variation was not dependent on the TMR devices location of a substrate. We found that MR ratio and spin-flip field (H's) increased as the resistance increased, which may be caused by local interface irregularity of the insulating layer. The variation of resistance value was 64.19 and MR ratio was 2.72, respectively. Our results imply that to improve the insulating layer fabrication process including annealing process to lessen interface modulation in order to mass produce the TMR devices.

  • PDF