Electrochemical Characteristics in Sea Water of Al-3%Mg Arc Spray Coating Layer for Corrosion Protection with Sealing Treatment (후처리 적용에 따른 방식용 Al-3%Mg 용사코팅 층의 해수 내 전기화학적 특성)

  • Park, Il-Cho;Kim, Seong-Jong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.5
    • /
    • pp.974-980
    • /
    • 2015
  • Arc thermal spray coating using Al-3%Mg thermal spray wire was carried out to prevent steel from corrosion damage under the marine environment. Post-sealing was applied to Al-3%Mg spray coating treatment using organic/inorganic composite ceramics in order to improve the corrosion resistance of the as-sprayed coating. The results of various electrochemical experiments with sealing treatment indicated that the improvement in corrosion resistance was observed due to low current density in all applied potential range during anodic and cathodic polarization experiments. Futhermore, the natural potential measurement exhibited severe potential fluctuation due to influence of micro-crack presence on the surface of sealed thermal spray coating layer. In addition, the sealed layer was easily eliminated during anodic polarization. Nevertheless, Al-3%Mg spray coating layer improved corrosion resistance by sealing treatment because the sealed coating efficiency was determined to be 92.11%, indicating the exterior environment barrier effect which is based on the Tafel analysis.

Analysis of Electrochemical Corrosion Resistance of Inconel 625 Thermal Spray Coated Fin Tube of Economizer (Inconel 625 용사코팅된 절탄기 핀튜브의 전기화학적 내식성 분석)

  • Park, Il-Cho;Han, Min-Su
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.1
    • /
    • pp.187-192
    • /
    • 2021
  • In this study, Inconel 625 was used as a thermal spray material to prevent dew point corrosion damage to the economizer tube, and sealing treatment was performed after applying the arc thermal spray coating technology. Various electrochemical experiments were conducted in the 0.5 wt% sulfuric acid solution to analyze the corrosion resistance of the thermal spray coating (TSC) layer. After the anodic polarization experiment, the degree of corrosion damage was determined through a scanning electron microscope and EDS component analysis. When measuring the open circuit potential, the effect of the sealing treatment was confirmed through stable potential formation of the TSC+sealing treatment (TSC+Sealing). As a result of the anodic polarization experiment, the passivation region was confirmed in TSC and TSC+Sealing, and corrosion resistance was improved as no corrosion damage was observed. In addition, the corrosion resistance of TSC+Sealing was the best when analyzing the corrosion potential and corrosion current density calculated by Tafel analysis.

The effect of immediate and delayed recognition memory on event-related potential(ERP) (즉각적 재인 기억과 지연 재인 기억이 사건과련전위에 미치는 영향)

  • 김명선;조상수;권준수
    • Korean Journal of Cognitive Science
    • /
    • v.11 no.3_4
    • /
    • pp.83-93
    • /
    • 2000
  • The effect of immediate and delayed recognition memory on event-related potential (ERP) was studied using a continuous recognition memory task and event-related potential (ERP). Among 240 stimulus words 40 words were not repeated. 100 were immediately repeated and 100 were repeated after 5 intervening words. All words presented only once during the experiment were referred to as new words. Subjects responded faster and more accurately to words repeated immediately than to new words a and to those repeated after intervening words. In terms of ERP results the immediately repeated words were associated with large P300 amplitude, early P300 latency and a absence of N400. while words repeated after a delay were associated with small P300 a amplitude. late P300 latency and the presence of N400. N400 was elicited only to new w words and to those repeated after a delay. The general morphology of the waveform was s similar for three stimulus-presentation conditions until around 3l0ms after the onset of stimulus. These results indicate that immediate and delayed recognition memory could be dissociated into two distinct processes possibly being mediated by different cerebral mechanism, and the dissociation between two types of recognition memory emerges around 3l0ms poststim'ulus. The immediate and delayed recognition memory for words are considered in terms of template matching and memory searching.

  • PDF

A Study on the Corrosion Inhibition Measurement Method of Carbon Steel in Various Inhibited Solutions (부식억제제가 함유된 용액중에서 탄소강의 부식억제능 측정법)

  • 원덕수;김영근;이성민;고영태
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 1998.05a
    • /
    • pp.108-108
    • /
    • 1998
  • 일반적으로 탄소강은 수용액 중에 노출될 경우 전면부식에 의한 손상을 받는다. 그러나 부식방지를 위하여 부식억제제를 적용할 경우, 탄소강의 부식거동은 현저한 변화를 겪게된다. 이러한 부식거동의 변화는 첨가되는 부식억제제의 종류에 따라 분 류할 수가 있는데, 양극부식억제제, 음극부식억제제 그리고 이들의 혼합부식억제제로 분류할 수가 있다. 현장에 적용된 부식억제제 시스템 중에는 자동차용 부동액과 가스히터용 열전달 매체액이 있다. 이러한 부식억제제가 적용된 시스댐은 정확한 부식억제능의 평가에 의한 그 교체 시기의 결정이 매우 중요하다. 교체 시기가 빠를 경우, 유지비용이 과다하게 소요되는 문제가 있으며, 교체시기가 늦을 경우 설비의 부식을 초래하는 문제 가 있다. 따라서 부식억제제의 정확한 성능 평가법은 매우 중요하며, 이에 대한 다양 한 연구가 진행 중이다. 부식억제제가 함유된 용액의 부식억제성능을 평가하는 방법에는 대표적으로 무게 감량법을 이용하고 있다. 이 방법은 다종의 금속이 적용된 자동차용 부동액을 실제 사용조건과 유사한 실험 조건에서 단기간, 가혹조건에서의 무게 감량에 의해 부식억 제능을 평가하는 방법이다. 그러나 이러한 방법은 특히 국부부식이 진행될 경우 부 식억제능을 정량화 하는데 어려움이 있다. 한편 전기화학적 측정방법으로는 분극곡선법을 이용한 $E_P$(공식개시전위), $E_R$(재부동태 화전위)의 측정법이 있다. 또한 부식억제피막의 안정성을 측정하기 위한 방법으로 인 위적인 양극전류 인가에 의한 피막의 파괴후에 피막이 복원가능 여부 및 그 속도 측 정에 의해 부식억제제의 건전성을 확인할 수가 었다. 본 연구에서는 가스히터의 주구성 재료인 A210 Gr Al의 탄소강을 사용하여, 사용기간이 5년 이상되어 부식억제 기능을 거의 상실한 것으로 여겨지는 열전달 매체액 과 신규 부식억제제가 적용된 시스템 등 객관적으로 확인된 부식억제제 시스랩에 대 하여 다양한 평가 방법을 동원 비교분석하고자 하였다. 실험은 KSM 2142에 의한 무게감량법, 분극곡선 측정에 의한 $E_P$(공식개시전위), $E_R$(재부동태화전위) 측정, 시간에 따른 자연전위 변화 측정 빛 이때의 부식속도(선형분극법), 인위적인 피막 파괴 전,후 의 전위 변화 및 부식속도 측정법에 의한 국부부식 발달 저지능 등을 평가하여 각 실험결과를 비교분석하여 보았다.

  • PDF

Effect of Vanadium Addition on the Cavitation Erosion Resistance of Fe-Cr-Ni-Si-C Hardfacing Alloy (Fe-Cr-Ni-Si-C계 경면처리 합금의 Cavitation Erosion 저항성에 미치는 Vanadium 첨가의 영향)

  • 김경오;김준기;장세기;김선진;강성군
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 1998.11a
    • /
    • pp.72-72
    • /
    • 1998
  • 원자력발전소 1차계통내 밸브의 경면처리(hardfa따1잉에 사용되는 재료는 $90~343^{\circ}C$의 고온과 높은 접촉응력 그리고 급격한 압력변화가 일어나는 환경에서 사용되기 때문에 내마모성과 내식성 그리고 cavitation erosion 저항성이 우수한 Co계 Stellite 합금이 현재 사용되어진다. 그러나 Co가 원력발전소 1차계통의 방사선장을 형성하는 주요 원소로 알려지면서 S Stellite 합금을 대체할 수 있는 Fe계 경면처리용 합금을 개발하려는 연구가 진행되고 있다. 현재 Fe계 경면처리용 합금의 개발은 적절환 팝금원소를 첨가하여 적충결함에너지를 낮춤 으로써 전위의 교차슬립을 억제하여 표면을 경화시키고, 소성변형을 억제하여 마모저항성을 향상시키려는 방법으로 연구가 진행되고 있다. 본 연구에서는 Fe-Cr-Ni-Si-C 합금에 Fe계 합금의 적충결함에너지를 감소시키는 것으로 알려진 vanadium을 0, 1, 2wt%첨가하여 첨가량의 변화가 cavitation erosion 저항성에 미치 는 영향을 조사하였다. Cavitation erosion 실험은 초음파를 이용하여 미세한 기포를 발생시키는 vibratory type으로 A ASTM G-32 규격에 따라 제작된 실험장치를 이용하여 $25{\pm}2^{\circ}C$의 온도의 증류수 속에 잠긴 상태에서 실시하였다. 시면은 지름 16mm, 두게 7mm의 버턴형태로 vanadium 첨가량을 변화시킨 조성을 아크 용융 방법을 이용하여 제작하였으며 hom끝단부에 부착하여 cavitation e erosion 저항성 살험을 하였다. 시편의 cavitation erosion 실험시간에 따른 무게감소량을 측 정하였으며 cavitation erosion 시킨 시편의 표면을 SEM으로 관찰하였다.겨지는 열전달 매체액 과 신규 부식억제제가 적용된 시스템 등 객관적으로 확인된 부식억제제 시스랩에 대 하여 다양한 평가 방법을 동원 비교분석하고자 하였다. 실험은 KSM 2142에 의한 무게감량법, 분극곡선 측정에 의한 $E_P$(공식개시전위), $E_R$(재부동태화전위) 측정, 시간에 따른 자연전위 변화 측정 빛 이때의 부식속도(선형분극법), 인위적인 피막 파괴 전,후 의 전위 변화 및 부식속도 측정법에 의한 국부부식 발달 저지능 등을 평가하여 각 실험결과를 비교분석하여 보았다. 수록 민감하여 304 의 IGSCC 와 매우 유사한 거동을 보인다. 본 강연에서는 304 와 600 의 고온 물에서 일어나는 IGSCC 민감도에 미치는 환경, 예민화처리, 합금원소의 영향을 고찰하고 이에 대한 최근의 연구 동향과 방식 방법을 다룬다.다.의 목적과 지식)보다 미학적 경험에 주는 영향이 큰 것으로 나타났으며, 모든 사람들에게 비슷한 미학적 경험을 발생시키는 것 이 밝혀졌다. 다시 말하면 모든 사람들은 그들의 문화적인 국적과 사회적 인 직업의 차이, 목적의 차이, 또한 환경의 의미의 차이에 상관없이 아름다 운 경관(High-beauty landscape)을 주거지나 나들이 장소로서 선호했으며, 아름답다고 평가했다. 반면에, 사람들이 갖고 있는 문화의 차이, 직업의 차 이, 목적의 차이, 그리고 환경의 의미의 차이에 따라 경관의 미학적 평가가 달라진 것으로 나타났다.corner$적 의도에 의한 경관구성의 일면을 확인할수 있지만 엄밀히 생각하여 보면 이러한 예의 경우도 최락의 총체적인 외형은 마찬가지로 $\ulcorner$순응$\lrcorner$의 범위를 벗어나지 않는다. 그렇기 때문에도 $\ulcorner$

  • PDF

An Experimental Study on the Restoration Creation of Tidal Flats (간석지 생태계 복원에 관한 실험적 연구)

  • Lee, Jeoung-gyu;Lee, Nam-hoon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.8 no.1
    • /
    • pp.77-82
    • /
    • 2000
  • Seven constructed and three natural tidal flats were compared to evaluate state-of- the-art of creation and restoration technology for tidal flats. parameters studied were physico-chemical and biological characteristics of soils and rate of respiration. The natural tidal flats had higher contents of silts, nitrogen and organic matter compared to the constructed ones. The natural ones had reductive Bone below 2 cm whereas the constructed ones had oxidative zone from the surface to below 20 cm. The bacterial population in the soil of the constructed tidal flats was one to two magnitudes lower than that in the natural ones. Biomass of macrobenthos and microbial respiration rate, however, were not different significantly between the natural and the constructed tidal flats. The purification capacity by diatom+bacterial+meiobenthos and macrobenthos in the constructed tidal flats was higher than that in the natural ones due to deeper permeable layer for purification in the constructed tidal flats. There was an exceptional constructed tidal flat with similar physico-chemical and biological characteristics to natural ones. Shearing stress to the surface of the tidal flat by the flow of seawater was as low as that of natural ones. These hydraulic conditions seemed to be a controlling factor on structures and functions of tidal flats. The control of hydraulic condition seemed to be one of the most important factors to create natural-like tidal flats.

  • PDF

Comparison of the Ion Adsorption Method, Potentiometric Titraion and Backtitration Technique for Surface Charge measurement in Ultisol, Alfisol, and Inceptisol (Ultisol과 Alfisol 및 Inceptisol 토양에서 토양표면전하 측정에 사용된 이온흡착법, 전위차 적정법 및 역적정법간의 비교)

  • Lee, Sang-Eun;Neue, Heins Ulitz;Park, Jun-Kyu;Lim, Sookil H.
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.26 no.3
    • /
    • pp.160-171
    • /
    • 1993
  • Surface charge characteristics of Ultisol(Luisiana soil from Philippines), Alfisol(Maahas soil from Philippines), and Inceptisol(Yongii soil from Korea) were studied by way of potentiometric titration, backtitration technique, and ion adsorption method(or CEC - AEC method). The PZNC(point of zero net charge) values determined by ion adsorption method were much lower than the natural pHs in all soils, indicating that all soil samples bore net negative surface charge. The PZSE (point of zero salt effect) values determined by potentiometric titration and backtitration technique were identical in Luisiana and Yongii soils but not in Maaghas soil. All soils showed higher PZSE values than PZNC values probably due to the influence of permanent negative charge. The permanent charge calculated by the theory of Uehara and Gillman (1980) occupied quite low portion of the CEC measured at pH 7 in all soils. Backtitration technique corrected errors of potentiometric titration at extreme pH. However, it still overestimate the surface charge compared with ion adsorption method. Therefore, the ion adsorption method was recommanded for the surface charge measurement of the usual soils which have high negative charge components.

  • PDF

An Experimental Study on Relationship Between Half-Cell Potential and Corrosion Current Density of Chloride-Induced Corroded Steel in Concrete (염해에 따라 콘크리트 속에서 부식된 철근의 반전지전위와 부식전류밀도의 상관관계에 관한 실험적 연구)

  • Jo, Sang-Hyeon;Kim, Dong-Won;Kee, Seong-Hoon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.6
    • /
    • pp.1-13
    • /
    • 2022
  • This study aims to investigate the feasibility of the half-cell potential (HCP) measurements on the concrete surface for evaluation of corrosion rate (or corrosion levels) of reinforcing steel in concrete. A series of experimental study is performed to measure HCP (or corrosion potential, Ecorr) and corrosion current density (icorr) of reinforcing steel in concrete cube specimens, with a side length of 200 mm. Various corrosion levels in a range of 0% to 20% of the test specimens are accelerated by impressing current to the reinforcing steel in concrete immersed in 3.0 % NaCl solution. HCP is measured in accordance with ASTM C876-15, and corrosion current density is determined by using the Stern-Geary equation and measured polarization resistance measured by electrochemical impedance spectroscopy (EIS). As a result, a numerical formula that relates HCP and icorr in the test specimen is established by a regression analysis of the measured data in this study. It is observed that HCP is linearly correlated with log(icorr) with a R2 greater than 0.87, which is less affected by the experimental variables such as concrete mixture proportion, diameter of reinforcing steel and the amount of applied current in this study. These results exhibit that HCP measurements could be effective for evaluation of corrosion rate (or corrosion levels) of reinforcing steel in concrete in the case of exposed to a certain consistent environment.

Planar microchip-based lactate biosensor (평면 소자형 락테이트 바이오센서)

  • Ha, Jeonghan;Huh, Hwang;Kang, Tae Young;Lee, Yong Seok;Yoon, Soon Ho;Shin, Jungwon;Nam, Hakhyun;Cha, Geun Sig
    • Analytical Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.482-489
    • /
    • 2006
  • Two electrode-based lactate biosensor was prepared by immobilizing lactate oxidase (LOD) obtained from pediococcus species in a poly(vinyl alcohol). Hydrogen peroxide ($H_2O_2$) produced by the reaction of lactate and LOD was detected on the Pt-black that was electrochemically deposited on the Au electrode. Sensors fabricated with Pt-black deposited Au electrode provided a high current of $H_2O_2$ oxidation at a substantially lowered applied potential (+300 mV vs. Ag/AgCl), resulting in reduced interferences from easily oxidizable species such as ascorbic acid, acetaminophen, and uric acid. An outer membrane is formulated by adjusting water uptake of hydrophilic polyurethane (HPU). The sensor performance was evaluated in vitro with both flow-through arrangement and static mode. The sensor showed a linear range from 0.1 mM to about 9.0 mM in 0.05 M phosphate buffer (pH 7.6) containing 0.05 M NaCl. Storing the sensors prepared in this work at $4^{\circ}C$ buffer solution while not in use, they provided same electrochemical performance for more than 25 days.

An Experimental Study on the Durability and Reinforcement Corrosion of Polymer Cement Based Repair Material (폴리머시멘트계 단면복구재의 내구성 및 철근부식특성에 관한 실험적 연구)

  • Kim Young Sun;Kim Young Duck;Na Chul Sung;Cho Bong Suk;Kim Gyu Yong;Kim Moo Han
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.487-490
    • /
    • 2005
  • In this study, for the establishment of the performance evaluation methods and the quality control standards of durability recovery method, the data of indoor durability test and the data of the long term exposure test under the coast are accumulated and analyzed. As a result of the indoor test, durability of repair material was more superior to that of plain concrete, but as a result of investigating and evaluating exposure test at 30 month of exposure age under the coastal environment, the difference in electric potential and the reinforcement corrosion at place replaced with repair material are found.

  • PDF