A Study on the Implementation of a IoT Sensor-based Smart Compression System (센서 기반의 스마트 압축 시스템 구현에 대한 연구)

  • Oh, Eun-Young;Yoon, Keun-Young
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.6
    • /
    • pp.1287-1294
    • /
    • 2021
  • This paper is a study on the implementation of a sensor-based smart compression system for improving home and street environments. Since modernization, the amount of garbage has been increasing every year, and this has seriously adversely affected not only people but also ecosystems such as marine pollution and soil pollution. In particular, in large cities with large floating populations, garbage is dumped on the streets without proper measures to deal with the amount of waste generated. In order to improve this problem, this paper intends to implement a system with automatic compression and opening/closing functions using sensors. This system is designed to activate automatic opening/closing function through an infrared sensor, and automatically opening and closing when the inclination is changed using an impact sensor. In addition, by installing a distance sensor, the amount of internal waste can be easily monitored from the outside, and a manual compression switch and a manual opening/closing switch is separately designed to enable opening and closing and compression as needed to increase the effectiveness.

Diagnostic system development for state monitoring of induction motor and oil level in press process system (프레스공정시스템에서 유도전동기 및 윤활유 레벨 상태모니터링을 위한 진단시스템 개발)

  • Lee, In-Soo
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.19 no.5
    • /
    • pp.706-712
    • /
    • 2009
  • In this paper, a fault diagnosis method is proposed to detect and classifies faults that occur in press process line. An oil level automatic monitoring method is also presented to detect oil level. The FFT(fast fourier transform) frequency analysis and ART2 NN(adaptive resonance theory 2 neural network) with uneven vigilance parameters are used to achieve fault diagnosis in proposing method, and GUI(graphical user interface) program for fault diagnosis and oil level automatic monitoring using LabVIEW is produced and fault diagnosis was done. The experiment results demonstrate the effectiveness of the proposed fault diagnosis method of induction motors and oil level automatic monitor system.

Water Quality Management by Reservoir Discharge Control through Selective Withdrawal (선택취수를 이용한 댐하류 하천의 수질관리)

  • Kim Young Do;Yi Yong-Kon;Ko Ick Hwan;Kim Woo Gu
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.454-458
    • /
    • 2005
  • 여름철 집중강우시 유입되는 고탁수층은 저수지의 밀도성층으로 인하여 표수층 하부에 위치하며, 이를 적기에 배제하지 않을 경우에는 수평방향의 확산현상과 연직방향의 전도현상으로 인해 저수지 전역에 분포하게 되어, 탁수현상의 장기화를 유발한다. 일본 사메우라댐의 경우에는 1977년 9월 태풍 17호에 의한 집중호우로 대량의 고탁수가 유입되어 하류하천으로의 댐 방류수의 고탁도현상이 장기간 지속된 바 있다. 이와 같은 탁수장기화에 대한 저수지내 대책의 하나로서 홍수유입후 탁도가 높은 물을 단기간동안 방류하고, 갈수기에는 탁도가 낮은 물을 방류하는 선택취수 개념이 제안된 바 있다. 국내의 임하댐의 경우에도 2002년 태풍 '루사'와 2003년 태풍 '매미'로 인해 발생한 탁수가 전도현상을 거치며 저수지내 전수층에 확산됨으로써 댐방류수의 고탁도현상이 장기화된바 있다. 이로 인하여 댐하류에 위치한 안동시 용상정수장의 동절기 정수처리 장애로 2003년 11월이후 약 160여일동안 댐방류가 중단된 바 있다. 임하댐의 경우에도 탁수장기화에 대한 대책으로서 홍수기 고탁수층을 우선배제한 후, 저수지내에 유입되는 청수을 담수함으로써 이를 방지할 수 있다. 이러한 선택취수 기법은 동일한 수리동역학적 개념을 적용하여 하류하천의 냉해문제를 대비하기 위한 방법으로 표층의 온수를 선택방류하는 데에도 이용될 수 있다. 이와 같은 선택취수를 효율적으로 수행하기 위해서는 취수시설에 접근하는 밀도흐름을 정확하게 이해하고 있어야 한다. 또한 취수탑 인근에서의 온도 및 탁도 등의 연직분포를 실시간으로 파악할 수 있는 자동수질측정시스템이 구축되어 있어야 한다. 현재 임하댐의 경우, 하류하천의 수질을 고려한 효율적인 탁수배제를 위하여 상류 유입부 2개소, 발전취수탑 전면 1개소, 조정지댐 1개소 등 총 4개의 자동수질측정시스템이 설치되어 탁도와 온도가 실시간으로 모니터링되고 있으며, 향후 강우시 저수지에서의 밀도흐름을 보다 정밀하게 모니터링하기 위하여 저수지내 4개의 주요지점에 추가적으로 설치될 예정이다. 이와 같은 자동측정시스템과 더불어 주기적인 세부 수질조사를 실시하면 저수지내의 온도성층 변화와 탁수층 분포를 매우 정확하게 파악할 수 있으며, 호소의 수질모형과 연계하여 강우시 탁수 도달시간과 탁수량을 사전에 예측할 수도 있다. 또한 이와 같은 기초적인 정보를 바탕으로 하류하천의 탁수 피해를 최소화할 수 있는 선택취수탑의 운영방안을 수립할 수 있다 본 연구에서는 이를 위해 선택취수탑 주위의 성층흐름을 기존의 실험자료와 수치해석을 통하여 분석하였고, 온도성층구조나 취수구의 위치변화에 따른 방류수 수질특성을 조사하였다.

  • PDF

Analysis and Recognition of Behavioral Response of Selected Insects in Toxic Chemicals for Water Quality Monitoring (수질 모니터링을 위한 유해 물질 유입에 따른 생물체의 행동 반응 분석 및 인식)

  • Kim, Cheol-Ki;Cha, Eui-Young
    • The KIPS Transactions:PartB
    • /
    • v.9B no.5
    • /
    • pp.663-672
    • /
    • 2002
  • In this paper, Using an automatic tracking system, behavior of an aquatic insect, Chironomus sp. (Chironomidae), was observed in semi-natural conditions in response to sub-lethal treament of a carbamate insecticide, carbofuran. The fourth instar larvae were placed in an observation cage $(6cm\times{7cm}\times{2.5cm)}$ at temperature of $18^\circ{C}$ and the light condition of 10 time (light) : 14 time (dark). The tracking system was devised to detect the instant, partial movement of the insect body. Individual movement was traced after the treatment of carbofuran (0.1ppm) for four days 2days : before treatment, 2 days : after treatment). Along with the other irregular behaviors, "ventilation activity", appearing as a shape of "compressed zig-zag", was more frequently observed after the treatment of the insecticide. The activity of the test individuals was also generally depressed after the chemical treatment. In order to detect behavioral changes of the treated specimens, wavelet analysis was implemented to characterize different movement patterns. The extracted parameters based on Discrete Wavelet Transforms (DWT) were subsequently provided to artificial neural networks to be trained to represent different patterns of the movement tracks before and after treatments of the insecticide. This combined model of wavelets and artificial neural networks was able to point out the occurrence of characteristic movement patterns, and could be an alternative tool for automatically detecting presences of toxic chemicals for water quality monitoring. quality monitoring.

The Development of Remote Monitoring System for Storm Overflow Chamber Device (우수토실 일체형 하수유량조절장치 원격관리시스템 개발)

  • Jeon, In-Jae;Kim, Ki-Bong
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.6
    • /
    • pp.61-68
    • /
    • 2018
  • This paper propose the remote monitoring system using LoRa networks about storm overflow chamber, which is a device designed to discharge rainwater directly to a sewage treatment plant when it reaches a certain amount of rainfall during precipitation. In this system, when the information produced by the sensor is transmitted to the LoRa network server and updated, the application server can automatically receive data through the implemented communication interface. The application server carries out management functions of storm overflow chamber devices and subscription information, collects measured flow rate and opening-closing information, and provides statistical information using the collected data. The android app performs a firebase-based notification function to prompt the user of malfunctioning of the storm overflow chamber device.

A Study of Automatic Detection of Music Signal from Broadcasting Audio Signal (방송 오디오 신호로부터 음악 신호 검출에 관한 연구)

  • Yoon, Won-Jung;Park, Kyu-Sik
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.47 no.5
    • /
    • pp.81-88
    • /
    • 2010
  • In this paper, we proposed an automatic music/non-music signal discrimination system from broadcasting audio signal as a preliminary study of building a sound source monitoring system in real broadcasting environment. By reflecting human speech articulation characteristics, we used three simple time-domain features such as energy standard deviation, log energy standard deviation and log energy mean. Based on the experimental threshold values of each feature, we developed a rule-based algorithm to classify music portion of the input audio signal. For the verification of the proposed algorithm, actual FM broadcasting signal was recorded for 24 hours and used as source input audio signal. From the experimental results, the proposed system can effectively recognize music section with the accuracy of 96% and non-music section with that of 87%, where the performance is good enough to be used as a pre-process module for the a sound source monitoring system.

Development of Radio Spectrum Monitor for HF Communication (단파 스펙트럼 수신 모니터링 시스템 개발)

  • Park, Sung Won;Kim, Young Yun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.9
    • /
    • pp.821-827
    • /
    • 2015
  • Electromagnetic waves which are emitted from the Sun due to solar flare explosion can cause failures in HF radio communications in the day-side area of the Earth, that is so-call as Radio Blackouts. The international scale representing the severity of the Radio Blackouts is determined by the solar X-ray flux which is measured by United States Geostationary Operational Environmental Satellite. However, the scale is not always applicable to HF communication users in the different area on the Earth, because the HF communication effects depend not only on the X-ray strength but also on the subsolar point location. To solve this problem, we developed a HF radio spectrum monitoring system utilizing a spectrum analyzer. This system conducts a real-time measure of the HF spectrum, and automatically calculates signal to noise ratios and the occurrences of the HF blackouts as comparing with the interference level which is described from the ITU recommendation.

Design and Implementation of a Cloud-Based Recovery System against Ransomware Attacks (클라우드 기반 랜섬웨어 복구 시스템 설계 및 구현)

  • Ha, Sagnmin;Kim, Taehoon;Jung, Souhwan
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.27 no.3
    • /
    • pp.521-530
    • /
    • 2017
  • In this paper, we propose a protection solution against intelligent Ransomware attacks by encrypting not only source files but also backup files of external storage. The system is designed to automatically back up to the cloud server at the time of file creation to perform monitoring and blocking in case a specific process affects the original file. When client creates or saves a file, both process identifiers, parent process identifiers, and executable file hash values are compared and protected by the whitelist. The file format that is changed by another process is monitored and blocked to prevent from suspicious behavior. By applying the system proposed in this paper, it is possible to protect against damage caused by the modification or deletion of files by Ransomware.

A Study on Survivability of Node using Response Mechanism in Active Network Environment (액티브 네트워크 환경에서 대응 메커니즘을 이용한 노드 생존성에 관한 연구)

  • Yang, Jin-Seok;Lee, Ho-Jae;Chang, Beom-Hwan;Kim, Hyoun-Ku;Han, Young-Ju;Chung, Tai-Myoung
    • The KIPS Transactions:PartC
    • /
    • v.10C no.6
    • /
    • pp.799-808
    • /
    • 2003
  • Existing security solutions such as Firewell and IDS (Intrusion Detection System) have a trouble in getting accurate detection rate about new attack and can not block interior attack. That is, existing securuty solutions have various shortcomings. Shortcomings of these security solutions can be supplemented with mechanism which guarantees an availability of systems. The mechanism which guarantees the survivability of node is various, we approachintrusion telerance using real time response mechanism. The monitoring code monitors related resources of system for survivability of vulnerable systm continuously. When realted resources exceed threshold, monitoring and response code is deployed to run. These mechanism guarantees the availability of system. We propose control mathod about resource monitoring. The monitoring code operates with this method. The response code may be resident in active node for availability or execute a job when a request is occurred. We suggest the node survivability mechanism that integrates the intrusion tolerance mechanism that complements the problems of existing security solutions. The mechanism takes asvantage of the automated service distribution supported by Active Network infrastructure instead of passive solutions. The mechanism takes advantage of the automated service distribution supported by Active Network infrastructure instead of passive system reconfiguration and patch.

A Study on Application of IEC61850 to "GIS Condition monitoring and Diagnosis System" (온라인 GIS 예방진단시스템의 IEC61850 적용 연구)

  • Park, Dong-Ho;Min, Byoung-Woon
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.250-251
    • /
    • 2006
  • 현대 전력산업은 IEC61850의 표준화작업이 한창 진행중이다. IEC61850-7-4는 전력설비 요소마다 Logical Node를 선언해 놓았다. 현재의 Logical Node는 보호, 제어, 인터페이스, 기록, 자동, 측정, 센서 & 모니터링, 변전기기 등의 그룹으로 나뉘어져 있다. 그러나 본 논문에서 대상으로 하는 GIS 예방진단 시스템에 관한 Logical Node와 공통 데이터 클레스(CDC: Common Data Class)가 명확히 선언되지 않았다. 1993년 IEC61850의 객체모델이 제안될 때부터 변전소의 다양한 설비를 완벽하게 객체화 할 수 있는가에 대한 의문이 있었으며 현재에서 이런 의문점을 개선하기 위하여 TC57위원회에서는 지속적인 모델 수정 및 정비 작업을 수행하였다. 실제로 현재에도 전력품질에 대한 logical node가 'Q'그룹으로 새롭게 제시되고 있고 풍력발전이나 분산전원에 대한 logical node가 추가되거나 기존의 IEC61850-7-4의 내용이 수정되고 있는 실정이다. 본 연구는 이와 같이 변전설비 자동화에 필요하지만 IEC TC57에서 표준화되지 않은 온라인 GIS 예방진단용 설비에 대한 표준모델을 제시하였고 모델에 대한 logical node나 CDC를 구성하였다.