• Title/Summary/Keyword: 자동측정시스템

Search Result 1,047, Processing Time 0.035 seconds

A Study on the Smart Filter System for External Environment Recognition (외부환경 인식용 스마트 필터 시스템에 대한 연구)

  • Seo, Do-Won;Yoon, Keun-Young
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.2
    • /
    • pp.271-278
    • /
    • 2021
  • This paper is a study on the implementation of smart filter system that recognizes the external environment and automatically removes pollutants according to pollution level. Recently, the occurrence of various pollutants in indoor and outdoor space has adversely affected the human body. Especially, various fine dust generated in the atmosphere becomes worse in closed residential space or office space. Although air pollution can be temporary lowered through ventilation, it is difficult to respond to fine dust changes in real time, and such problems become serious in the space where many people reside, such as at home or industry. Therefore, it is necessary to measure the pollution level of fine dust inside the residential space in real time and to reduce the pollution of indoor ventilation through automatic ventilation with the outside. To improve these problems, this paper proposes the implementation of smart filter system for external environment recognition. The structure of smart filter system that automatically measures air quality inside and outside, removes pollutants, implements the function, and confirms the operability by manufacturing prototypes. Finally, the effectiveness of the smart filter system for solving fine dust problems was examined.

Unit Under Tester Auto System using OCR(Optical Character Recognition) (Optical Character Recognition을 이용한 계측기기 자동 교정시스템구축기술)

  • Kang, Sang-Mu;Kim, Young-Jic;Cheon, Yong-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1772-1773
    • /
    • 2011
  • 현대기술의 발전에 따라 계측기술 또한 다양하고 복잡하게 변모하였으며, 정밀측정기기의 교정 업무에서는 복잡하고 정확한, 반복적이며 계속적인 데이터 취득을 요구한다. 또한 여러 장비를 사용할 경우, 장시간 소요되는 데이터 취득과 정확한 계측기 사용법 및 고도의 관련기술을 필요로 한다. 그러므로 컴퓨터를 이용 한 계측장비 제어로 측정에 필요한 시간을 최대한 단축하고, 개인오차를 제거할 수 있는 동일한 결과와 쉽게 데이터를 취득할 수 있도록 측정자동화가 필요하다.

  • PDF

Stitch Reliability Measurement for Recovering Accurate Camera Focal Length in Panoramic Mosaics (파노라마 모자익에서의 정확한 초점거리 복원을 위한 접합 신뢰도 측정방법)

  • Kim, Hwa-Seong;Kim, Chang-Heon
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.28 no.3
    • /
    • pp.125-133
    • /
    • 2001
  • 본 논문은 파노라마 모자익의 접합 질을 판단하기 위해 접합 신뢰도라는 수량적 기준을 제시한다. 또한, 파노라마의 자동 생성과 따른 시각화를 위해 필요한 초점거리 측정에 접합 신뢰도가 유용함을 보인다. 이미지로부터 초점거리를 복원하는 기존 방법은 일반적인 파노라마 모자익에서 나타나는 잘못 접합된 부분을 초점거리 계산에 포함하기 때문에 부정확하다는 단점이 있다. 제안 방법은 높은 접합 신뢰도를 가진 일정 개수의 이미지를 선별할 수 있기 때문에 초점거리를 따르고 정확하게 자동 측정한다. 접합의 신뢰도를 계산하기 위해, 제안 방법은 카메라 회전 움직임 제약조건의 만족 여부를 판단할 수 있는 특징점을 정의하고, 이 특징점의 이상적인 위치와 실제 위치의 차이를 계산한다. 본 논문에서 제시한 제약조건은 카메라의 자유 회전 움직임에서 항상 만족하고, 이는 수학적으로 증명된다. 마지막으로, 실험을 통해 제안 방법이 기존 방법보다 초점거리의 편차가 작다는 것을 보이고, 파노라마 모자익의 접합 질을 높인다는 것을 보인다.

  • PDF

Medical Image-Based Sarcopenia Automatic Diagnosis Support System and Its Application:: Liver Disease Analysis (의료영상 기반 근감소증 자동진단 지원 시스템 및 응용 : 간질환 분석)

  • Si-Hyeong Noh;Dong-Wook Lim;Chang-Won Jeong
    • Annual Conference of KIPS
    • /
    • 2024.05a
    • /
    • pp.702-704
    • /
    • 2024
  • 최근 사회적으로 근감소증에 대한 관심이 높아지면서 노인성 근감소증 시장이 골다공증 시장을 뛰어 넘을 것으로 전망하고 있다. 진단 방법으로 의료영상기반으로 근육량을 인공지능 기술로 측정하여 근감소증 진단에 적용하는 연구가 활발하게 진행되고 있다. 본 논문에서는 복부 CT 영상에서 L3 부위의 근육량을 기반으로 한 진단 기준을 이용하여 아시아 피험자의 T-score를 기반으로 근감소증 진단을 자동화하였다. 특히 복부 CT영상의 업로드와 함께 자동으로 근육량을 측정하여 개인별 상태를 확인할 수 있도록하여 근감소증 진단을 지원 할 수 있도록 개발하였다. 그리고 이를 기반으로 4가지 간 질환 환자의 L3 부위 근육량을 측정하여 근감소증과의 상관성을 확인하였다. 이는 다양한 기저 질환과 근감소증과의 연관성 연구에 도움이 될 것으로 기대한다.

초고속통신망하에서의 GIS를 이용한 대기측정시스템에 관한 연구

  • Lee, Bong-Gyu
    • 한국공간정보시스템학회:학술대회논문집
    • /
    • 1999.06a
    • /
    • pp.85-92
    • /
    • 1999
  • 본 연구는 초고속통신망하에서 GIS를 이용하여 상시 자동대기측정망으로부터의 대기정보에 대한 데이터베이스를 구축하고 1시간 간격으로 일반사용자가 특정지역의 대기상태 및 예경보 현황을 인터넷 서비스 받을 수 있는 시스템 개발을 연구 목적으로 한다. 본 연구의 결과를 이용하면 일반사용자도 대기상황에 대한 정보를 쉽게 이해할 수 있고, 구축된 GIS 데이터베이스를 이용하여 지역별로 측정 및 예측된 오염상태를 활용한 총 대기오염의 현황을 산출할 수 있다. 또한 대기측정기 이상에 의한 자료입력 불능에 대비한 날씨, 시간, 요일 별 대기상황 예측이 가능할 것이며, 대기오염측정기의 최적설치장소 선정 및 관리에도 활용할 수 있을 기대된다. 그리고 지속적이고 신뢰성 있는 데이터베이스 구축을 통해 중장기 대기오염측정 및 저감대책을 수립하는데 기여할 수 있을 것이다.

  • PDF

Development of 2 Division Illuminance Measurement Mobile Systems (차량을 이용한 2분할 조도측정시스템의 개발)

  • Jo, Deok-Soo;Lee, Chang-Mo;Jung, Seung-Gyun;Seok, Doe-Il;Kim, Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.1
    • /
    • pp.1-6
    • /
    • 2008
  • It is important to grasp the accurate lighting level for appropriate maintenance of the road lighting equipment. It is developed 2 division illuminance measurement systems. This system has a small size and no need to block the way and achieves the speedy measurement and high accuracy data in automatically measurement. As a result, this system can save expense and time to measure roadway lighting.

Measurement of Electrical Treeing Length and Area by Use of Image Processing (영상 처리 방법을 이용한 트리 길이와 열화면적 계측)

  • 백관현;김재환
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.8 no.1
    • /
    • pp.57-62
    • /
    • 1994
  • In this paper, a system for measuring of treeing degradation in organic dielectric material by using image processing technics, is discussed. Traditionally, treeing is measured by visual method. It made difficulty to understanding for features and changes in the configlEation of the tree growth. Using image processing system, it is made to describe the characters of the tree growth, specially length of tree and area of treeing degradation. From this image processing and visual measurement, the similar results were made, an automatic measurement system was made for configuration of the tree growth.

  • PDF

Design and Implementation of Measurement System of Carpus Callosum (뇌량의 형태검출 및 측정 시스템의 설계 및 구현)

  • Choi, Yoo-Joo;Tae, Woo-Suk;Hong, Seung-Bong;Kim, Myoung-Hee
    • Annual Conference of KIPS
    • /
    • 2002.04b
    • /
    • pp.1235-1238
    • /
    • 2002
  • 본 연구에서는 선천적 뇌량의 기형 판별 및 타질환에 의한 뇌량의 형태학적 변화추적을 위한 뇌량의 형태검출 및 측정 시스템을 설계, 구현하였다. 개발 시스템은 대뇌에 대한 자기공명영상의 정중시상단면을 기반으로 간단한 사용자 인터랙션을 통하여 초기 뇌량 영역을 선택하고, 영역확장법과 윤곽선 검출기법을 통하여 뇌량의 형태를 검출하였다. 또한, Witelson의 영역측정 기준에 따라, 뇌량의 영역을 7개의 영역으로 구분하고, 각 구성영역의 크기를 자동 측정함으로써, 뇌량의 형태학적 변화분석이 용이하도록 하였다.

  • PDF

Implementation of Acoustic Properties Measurement System Based on LabVIEW Using PXI for Marine Sediment (PXI를 이용한 LabVIEW기반 해양퇴적물의 음향특성 측정시스템 개발)

  • Park, Ki-Ju;Kim, Dae-Choul;Lee, Gwang-Soo;Bae, Sung Ho;Kim, Gil Young
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.18 no.3
    • /
    • pp.216-222
    • /
    • 2015
  • A previous velocity measurement system for marine sediment had several problems such as the errors occurred when picking first arrival time and the inconvenient measurement procedure. In order to resolve these problems, we developed a new acoustic properties measurement system by using PXI (PCI eXtentions for Instrumentation) module based on LabVIEW. To verify the new system, we measured the velocity and attenuation of sediment using the new system in a parallel with the previous system under the same experimental environment. The result of measurement showed 1~2% margin of error for the velocity as well as similar attenuation values. We concluded that the new system can efficiently measure the acoustic properties of marine sediment. It also has an advantage to construct the database of acoustic data and raw signal.

Efficacy of Automatic Dispensing/Injection System to Reduce Radiation Exposure of Nuclear Medicine Workers During PET Procedures (PET 검사에서 작업종사자의 방사선 노출 선량을 줄이기 위한 자동 분주/주사 시스템의 유용성)

  • Cho, Young-Kwon
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.8
    • /
    • pp.220-224
    • /
    • 2014
  • In this study we assessed the efficacy of an automatic dispensing/injection system (ADIS) to reduce the radiation exposure of workers during PET procedures. NMW(Nuclear Medicine Workers) were classified into 2 groups, one of which used conventional method and the other used an ADIS. The radiation dose during injection were also measured in both groups, with another set of experiment. In dispensing step, ADIS imposed significantly less radiation dose than conventional method, both to finger and to whole body. In injection step, ADIS also imposed significantly less dose to finger, while the dose of whole body was somewhat larger in ADIS than in conventional method. Using ADIS, the radiation exposure of NMW during dispensing was markedly reduced. Also, the exposure of finger during injection was markedly reduced, although exposure of whole body was mildly increased.