• Title/Summary/Keyword: 자기적 분리

Search Result 278, Processing Time 0.455 seconds

Mechanical Properties of the High Flowing Self-Compacting Concrete for Members of Bridge Overcrowded Arrangement of Bar (과밀 배근된 교량 부재용 초유동 자기충전 콘크리트의 역학적 특성)

  • Choi, Yun-Wang;Kim, Yong-Jic;Kang, Hyun-Jin
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.2
    • /
    • pp.175-183
    • /
    • 2008
  • Domestically, application of High Flowing Self-Compacting Concrete (HSCC) is limited to building structures and it is difficult to find examples of application in civil infrastructural constructions. However, in the case of North America and Europe, by introducing precast and prestressed system, HSCC is being used for high-density reinforced bridge members. Hence it is assessed that broadening the utilization of HSCC into areas such as bridges and civil construction is required. Therefore in this research, to apply HSCC to high-density reinforced bridge members, ground granulated blast-furnace slag and fly ash were mixed in binary and ternary systems. Also the dynamical characteristics of HSCC, following 1st class regulations of Japan Society of Civil Engineers (JSCE), were assessed to enable application on high-density reinforced structures. The test results revealed ternary system mixture showed better mechanical characteristics than binary system mixture and the application on high-density reinforced precast bridge members seems possible.

High-Speed RNA Isolation Using Magnetic Oligo(dT) Beads and Lateral Magnetophoresis (올리고-dT 자성입자와 측면방향 자기영동을 이용한 초고속 RNA 추출 기술)

  • Lee, Hwan-Yong;Han, Song-I;Han, Ki-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.12
    • /
    • pp.1309-1316
    • /
    • 2011
  • This paper presents a high-speed RNA microextractor for the direct isolation of RNA from blood lysate using magnetic oligo(dT) beads. The extraction is performed through lateral magnetophoresis, which is induced by a ferromagnetic wire array inlaid. With this RNA microextractor, more than 80% of the magnetic beads could be separated at a flow rate up to 20 ml/h, and the overall extraction procedure was completed within 1 min. The absorbance ratio of RNA to protein(A260/A280) was greater than 1.7, indicating that the extraction technique yields pure RNA. The feasibility of using this technique in reverse transcription polymerase chain reaction procedures was investigated by cDNA synthesis and PCR processes. The results confirmed that the RNA microextractor is a practical device for easy, fast, and high-precision RT-PCR using minimal amounts of reagent.

Magnetic Noise Reduction in MCG Using Spatial Filters (공간 필터를 이용한 심자도 신호에서의 자기잡음 제거)

  • Lee, Hana;Kim, Ki-Wang;Lee, Soo-Yeol;Cho, Min-Hyung;Heo, Young
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.4
    • /
    • pp.287-292
    • /
    • 2003
  • Even though MCG has many advantages over ECG, MCG signa)s are easily corrupted by external magnetic noises Since multi-channel MCG signals are recorded simultaneously at many spatial positions, it is effective to apply spatial fitters as well as the conventional temporal filters to remove external magnetic noises. The spatial filters can be designed by utilizing the fact that the noise signals caused by external noise sources are more spatially correlated than the original MCG signals. In this paper, we introduce a spatial filtering method for the noise reduction in MCG based on the principal component analysis. Healthy volunteer study results obtained with a 61-channel MCG system are presented.

Construction of the NQR Gaussmeter using Computer Interface (Computer Interface를 이용한 핵 사중극 공명 Gaussmeter의 제작)

  • 김혜진;신종필;조성호;김창석
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.2
    • /
    • pp.99-102
    • /
    • 1995
  • When the low magnetic field is applied to the synunetry axis of the axial synunetric electric field gradient tensor of the quadrupolar nucleus in the crystal with nuclear spin, I=1, two split resonance frequencies are observed by the Zeeman effect on the nuclear quadrupole resonance. The applied magnetic field is proportional to the difference of the two resonance frequencies and this proportionality constant for the $^{14}N$ of ${(CH_{2})}_{6}N_{4}$ single crystal is 0.16 mT/kHz. The NQR spectrometer is interfaced with a personal computer from which the resonance signals are displayed and the value of magnetic field is obtained directly from the difference of the two resonance frequeocies. The lowestest measured magnetic field was 0.20 mT using this NQR technique.

  • PDF

Field Map Estimation for Effective Fat Quantification at High Field MRI (고자장 자기공명영상에서 효율적인 지방 정량화를 위한 필드 맵 측정 기술)

  • Eun, Sung-Jong;Whangbo, Taeg-Keun
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.11
    • /
    • pp.558-574
    • /
    • 2014
  • The number of fatty liver patients is sharply growing due to the rapid increase in the incidence of metabolic syndrome, which can lead to diseases such as abdominal obesity, hypertension, diabetes, and hyperlipidemia. Early diagnosis requires examinations using magnetic resonance imaging (MRI), wherein quantitative analyses are implemented through a professional water-fat separation method in many cases, as the intensity values of the areas of interest and non-interest are considerably similar or the same. However, such separation method generates inaccurate results in high magnetic fields, where the inhomogeneity of the fields increases. To overcome the limits of such conventional fat quantification methods, this paper proposes a field map estimation method that is effective in high magnetic fields. This method generates field maps through echo images that are obtained using the existing IDEAL sequences, and considers the wrapping degree of the field maps. Then clustering is performed to separate calibration areas, the least square fits based on the region growing method schema of the separated calibration areas, and the histograms are adjusted to separate the water from the fats. In experiment results, our proposed method had a superior fat detection rate of an average of 86.4%, compared to the ideal method with an average of 61.5% and Yu's method with an average of 62.6%. In addition, it was confirmed that the proposed method had a more accurate water detection rate of 98.4% on the average than the 88.6% average of the fat saturation method.

Magnetic Properties of Cr/CoPtCr/$SiO_2$Thin Films for High Density Magnetic Recording Media (고밀도 자기기록매체용 Cr/CoPtCr/$SiO_2$ 다층박막의 자기적 성질)

  • Choi, H.;Hong, Y.G.;Kim, C.O.
    • Korean Journal of Materials Research
    • /
    • v.8 no.6
    • /
    • pp.560-564
    • /
    • 1998
  • CoPtCr magnetic layer was fabricated on the Cr underlayer by RF magnetron sputtering and the protective $SiO_2$ layer was deposited at room temperature. As the thickness of Cr underlayer increased, the coercive force of magnetic layer increased, then saturated slightly further increasing Cr underlayer thickness. Maximum coercive force was 860 Oe. It is thought that in-plane arrangement of magnetic phase and magnetic decoupling between the magnetic crystallites could lead to the increase of the coercive force. Post-annealing raised the coercive force exceedingly. and maximum coercive force value was 1650 Oe which was acquired from the sample annealed at 55$0^{\circ}C$ for 1hr.

  • PDF

An Analysis on the Geomagnetic Transfer Function at Yongin Observatory Using by RR (Remote Reference) and SNS (Signal Noise Separation) Technique (원격참조(RR: Remote Reference) 기법과 신호잡음분리(SNS: Signal Noise Separation)기술을 이용한 용인 관측소의 지자기 전달함수 분석)

  • Yang Junmo;Lee Duk-Kee;Kwon Byung-Doo;Ryu Yong-Gyu;Youn Yong-Hoon
    • Economic and Environmental Geology
    • /
    • v.38 no.2 s.171
    • /
    • pp.155-163
    • /
    • 2005
  • For an unbiased TF (Tansfer Function) estimations we investigate geomagnetic TF derived from ICHEON and YONGIN sites, employing RR (Remote Reference) and SNS (Signal Noise Separation) techniques. The Rh technique, which requires synchronized field variations recorded at a clean remote site, is a reliable method to minimize the bias of TF by uncorrelated noises in magnetic channels. Meanwhile, SNS technique based on the assumption of noise-free remote data can improve the signal-noise level by separating signal TF and noise TF, which is successfully applied to the environments with strong correlated noises. In this study, TF at YONGIN is analyzed using geomagnetic data from ICHEON site as a remote reference, which seem to have somewhat better data quality. The application of Rh technique reduces the bias of TF, which appears in single site robust estimation, and makes curves in the amplitude and phase of TF more smooth as frequency. Futhermore, in order to investigate noise source quantitatively, SNS technique is applied. The results of SNS suggest that dominant noise source seems to be located at western region of YONGIN. This noise source is considered to originate from railway system such as KTX and national subway. which passes through the west regions of YONGIN.

레이저 유기 형광법을 이용한 자기장이 인가된 유도결합플라즈마의 전기장 특성 연구

  • Song, Jae-Hyeon;Kim, Hyeok;Jeong, Jae-Cheol;Hwang, Gi-Ung
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.474-474
    • /
    • 2010
  • 현재 반도체시장의 확장으로 인해서 기존의 300mm 웨이퍼에서 450mm의 웨이퍼를 사용하는 공정으로 변화하는 추세이다. 450mm 웨이퍼로 대면적 화되면서 기존 300mm 공정 때보다 훨씬 효율적인 플라즈마 소스 즉, 고밀도이고, 고균등화(high uniformity) 플라즈마 소스를 필요로 한다. 본 논문에서는 고밀도 플라즈마 소스인 유도 결합형 플라즈마(Inductively Coupled Plasma ; ICP)에 축 방향의 약한 자기장을 인가시킨 자화된 유도결합형 플라즈마(Magnetized Inductively Coupled Plasma : MICP)[1]를 제안하여 기존 ICP와의 차이점을 살펴보았다. 실험 방법으로 레이저 유기 형광법(Laser Induced Fluorescence : LIF)[2]을 이용하여 플라즈마 쉬스(Sheath) 내의 전기장을 외부 자기장의 변화에 따라 높이별로 측정하고 그 결과로부터 쉬스의 전기적 특성을 살펴보았다. 플라즈마의 특성상 탐침이나 전극에 전압을 인가하면 그 주위로 디바이 차폐(Debye Shielding)현상이 일어나서 플라즈마 왜곡이 일어난다. 그렇기에 플라즈마, 특히 플라즈마 쉬스의 특성을 파악하기 위해서 레이저라는 기술을 사용하였다. 레이저는 고가의 장비이고 그 사용에 많은 경험지식(know-how)를 필요로 하지만 플라즈마를 왜곡시키지 않고, 플라즈마의 밀도, 온도, 전기장 등 많은 상수(parameter)들을 얻어 낼 수 있다. 또한 3차원적으로 높은 분해능을 가지고 있는 장점이 있다. 강한 전기장이 있는 곳에서 입자들의 고에너지 준위가 전기장의 세기에 비례하여 분리되는 Stark effect[3] 이론을 이용하여 플라즈마 쉬스내의 전기장을 측정하였다. 실험은 헬륨가스 700mTorr 압력에서 이루어졌다. 기판의 파워를 50W에서 300W까지 변화시키면서 기판에 생기는 쉬스의 전기장의 변화를 살펴보았고, 자기장을 인가한 후 동일한 실험을 하여 자기장의 유무에 따른 플라즈마 쉬스의 전기장 변화를 살펴보았다. 실험결과 플라즈마 쉬스의 전기장의 변화는 기판의 파워와 플라즈마 밀도에 크게 의존함을 알았다. 기판의 파워가 커질수록 쉬스의 전기장은 커지고, 기판에 생기는 Self Bias Voltage역시 음의 방향으로 커짐을 확인 하였다. 또한 자기장을 걸어주었을 경우 쉬스의 두께가 얇아짐으로써 플라즈마의 밀도가 증가했음을 확인 할 수 있었다.

  • PDF

Acute Infrapatellar Fat Pad Separation after Contusion in the Kneeling Position (슬관절의 과굴곡 상태에서 좌상 후 발생한 급성 슬개골하 지방괴의 분리 손상)

  • Yi, Seung Rim;Im, Se Hyuk;Cho, Eui Hwan
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.4
    • /
    • pp.341-345
    • /
    • 2021
  • The infrapatellar fat pad (IPFP) is one of three fat pads located about the anterior knee. Injury in this region is relatively common. Damage to the IPFP is caused mostly by an iatrogenic injury from a surgical procedure or repeated small collision trauma. The authors experienced a case of an IPFP injury, that has not been reported in the domestic or international literature. In this case, acute IPFP separation followed by a contusion at the anterior aspect of knee in the kneeling position, confirmed using magnetic resonance imaging. The patient was fully recovered with conservative treatment.

The Magnetic Properties of Amorphus Phase in Mechanically Alloyed $Fe_{50}Zr_{50}$ Powders (기계적 합금화한 비정질 $Fe_{50}Zr_{50}$ 분말의 자기특성)

  • 이성의;나형용;김원태;유성초
    • Journal of the Korean Magnetics Society
    • /
    • v.7 no.1
    • /
    • pp.7-12
    • /
    • 1997
  • Amorphous $Fe_{50}Zr_{50}$ alloy has been manufactured by mechanical alloying from pure elemental powders of Fe and Zr in conventional ball mill under an Ar atmosphere. Structure and magnetic properties of the amorphous phase were studied by transmission electron microscopy and SQUID magnetometry. Selected area diffraction patterns taken from the mechanically alloyed powders showed two halo rings, indicating coexistence of Fe rich and Zr rich amorphous phases in mechanically alloyed powder. Curie temperature of the Fe rich amorphous phase, measured by Arrot plot, was 195 K. Fe content in the ferromagnetic amorphous phase, estimated from the Curie temperature, was about 65 at%. Spin wave stiffness constant of $Fe_{50} Zr_{50}$ alloys processed for 100 and 200 hrs were 52.2 and 63.8 meV, respectively. The higher spin wave stiffness constant in 200 hrs milled powders may arise from the precipitation of $\alpha$-Fe by partial crystallization of amorphous phase.

  • PDF