• Title/Summary/Keyword: 입사 방향성

Search Result 154, Processing Time 0.025 seconds

Active Stabilization for Surge Motion of Moored Vessel in Irregular Head Waves (불규칙 선수파랑 중 계류된 선박의 전후동요 제어)

  • Lee, Sang-Do;Truong, Ngoc Cuong;Xu, Xiao;You, Sam-Sang
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.26 no.5
    • /
    • pp.437-444
    • /
    • 2020
  • This study was focused on the stabilization of surge motions of a moored vessel under irregular head seas. A two-point moored vessel shows strong non-linearity even in regular sea, owing to its inherent non-linear restoring force. A long-crested irregular wave is subjected to the vessel system, resulting in more complex nonlinear behavior of the displacement and velocities than in the case of regular waves. Sliding mode control (SMC) is implemented in the moored vessel to control both surge displacement and surge velocity. The SMC can provide a closed-loop system with performance and robustness against parameter uncertainties and disturbances; however, chattering is the main drawback for implementing SMC. The goal of minimizing the chattering and state convergence with accuracy is achieved using a quasi-sliding mode that approximates the discontinuous function via a continuous sigmoid function. Numerical simulations were conducted to validate the effectiveness of the proposed control algorithm.

Qualitative Research of Job turnover and Stay, Based on Job Embeddedness (직무배태성에 따른 이직과 잔류의 영향 요인에 대한 질적 연구)

  • Hwari Eun;Jabok Koo;Taeyun Jung
    • Korean Journal of Culture and Social Issue
    • /
    • v.24 no.2
    • /
    • pp.221-250
    • /
    • 2018
  • The purpose of this study is to find out the causes of turnover, the causes of stay, and the effects of turnover of college graduates with early careers, based on the concept of job embeddedness and their stances. For this study, semi-structured interviews were conducted with 20 college graduates with early careers and the interviews were analyzed with phenomenological analytic research. The result of the study shows that the cause of turnover intention includes fit and link which are components of job embeddedness. More specifically, turnover intention of the interviewee is affected by fit which includes whether their ability and talent are used properly and whether their vision and culture fit well those of their organization, also affected by link which includes the formal or informal mutual relationship with coworkers and superiors. Stay intention, on the other hand, includes fit which contains satisfaction about work and organization, long-term career management. Stay intention also includes sacrifice which are anxiety about uncertain future and satisfaction about being employed. As an aspect of the effect of turnover, the satisfaction and fulfillment about work which are experienced after turnover by the interviewees and the satisfaction about coworkers and the team in which the interviewees are included offset the negative effect of turnover. The result also shows that organization should consider their workers' satisfaction about the first work, their amicable relationship, and turnover cost, to improve working and living standard of colleges graduates with early careers and to prevent them from turnover.

Dispersion Characteristics of Wave Forces on Interlocking Caisson Breakwaters by Cross Cables (크로스 케이블로 결속된 인터로킹 케이슨 방파제의 파력분산특성)

  • Seo, Ji Hye;Yi, Jin Hak;Park, Woo Sun;Won, Deck Hee
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.27 no.5
    • /
    • pp.315-323
    • /
    • 2015
  • Damage level of coastal structures has been scaled up according to increase of wave height and duration of the storm due to the abnormal global climate change. So, the design criteria for new breakwaters is being intensified and structural strengthening is also conducted for the existing breakwaters. Recently, interlocking concept has been much attention to enhance the structural stability of the conventional caisson structure designed individually to resist waves. The interlocking caisson breakwater may be survival even if unusual high wave occurs because the maximum wave force may be reduced by phase lags among the wave forces acting on each caisson. In this study, the dispersion characteristics of wave forces using interlocking system that connect the upper part of caisson with cable in the normal direction of breakwater was investigated. A simplified linear model was developed for computational efficiency, in which the foundation and connection cables were modelled as linear springs, and caisson structures were assumed to be rigid. From numerical experiments, it can be found that the higher wave forces are transmitted through the cable as the angle of incident wave is larger, and the larger the stiffness of the interlocking cable makes larger wave dispersion effect.

SF6/O2 가스를 이용한 다결정 실리콘 웨이퍼 RIE Texturing이 제작된 태양전지 동작특성에 미치는 영향

  • Park, Gwang-Muk;Lee, Myeong-Bok;Jeong, Ji-Hui;Bae, So-Ik;Choe, Si-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.395-396
    • /
    • 2011
  • 본 논문에서는 30% 내외의 평균반사율을 가지는 다결정 실리콘 태양전지의 입사광 손실을 최소화하여 광전변환효율 극대화를 구현하기 위해서 SF6/O2 혼합가스를 이용한 RIE 표면 texturing 공정을 수행하였다. 현재 다결정 실리콘 태양전지는 다양한 방향의 grain을 가지기 때문에 단결정 실리콘에 적용되는 습식 식각 방식이 다결정 실리콘 표면 texturing에 적절하지 않은 것으로 알려져 있다. 이를 개선하기 위해서 이방성 식각 특성을 가지는 다양한 texturing 방법이 시도되고 있다. 대표적으로 기계적인 방식의 V-grooving, 레이저 grooving, 플라즈마 건식식각을 이용한 texturing 및 산 용액을 이용한 texturing 등의 연구가 보고되고 있다. 그 중에서 플라즈마 건식식각 방식의 하나인 RIE를 이용한 표면 texturing 공정이 간단한 공정과 산업계 응용의 용이성 때문에 활발히 연구되어 왔다. 특히 Sandia group과 일본 Kyocera사의 연구 결과에서는 그 가능성을 입증하고 있다. 본 연구에서는 공정의 단순화와 안전한 공정을 위해서 SF6/O2 혼합 가스를 이용하여 마스크 패턴 공정없이 RIE texturing 공정을 수행하였으며, RIE-textured 다결정 실리콘에 대해서 태양전지를 제작하여 표면 texturing이 광전변환효율에 미치는 영향에 대해서 분석하였다. 그 결과 SF6/O2 혼합 가스를 이용한 RIE texturing은 다결정 실리콘 표면에 주로 needle 구조를 형성하는 것을 확인하였다. 각 texturing 조건별 반사율의 차이는 needle 구조의 조밀도와 관련되는 것을 알 수 있었으며, 동일 공정 parameter 상에서 식각 시간 1, 2, 3, 4, 5분 기준 시간에 따른 표면 구조 분석 결과 seed 가 형성되고 그에 따라서 needle 형태로 식각되는 과정을 관찰하였다. 반사율은 분당 약 4%씩 낮아져 5분 식각 후 14.45% 까지 낮아졌으며, 표면 구조에서 폭은 약 30 nm로 모두 일정하며, 길이가 약 20, 30, 50, 80, 100 nm으로 증가되었다. 이 결과로 보아 seed로부터 needle 구조가 심화되어가는 것을 알 수 있었다. 시간에 따른 RIE texturing 후 제작된 태양전지는 효율이 1분 식각 기준 15.92%에서 약 0.35% 씩 낮아져 5분 식각 후 14.4%로 낮아졌다. Voc 는 texturing 시간에 관계없이 일정하며 Isc가 점점 감소되는 것으로 확인되었다. EQE 결과도 이와 동일하게 RIE texturing 시간이 길어질수록 전체 파장 범위에서 일정하게 낮아지는 것이 관찰되었다. Electroluminescence(EL) 이미지 결과 texturing 시간이 길어진 태양전지일수록 점점 어두운 이미지가 나타나 5분 식각의 경우 가장 어두운 결과를 나타내었다. 이런 결과는 한 가지 이유보다는 복합적인 문제로 예상되는데 궁극적으로는 RIE 공정 후 표면에 쌓인 charged particle들이 trap 준위를 형성하여 효율 및 공정상에 영향을 미친 것으로 보이며, 특히 잔류 O기가 불균일한 산화막을 형성하는 것으로 예상된다. 또한 EL 분석 결과를 볼 때 RIE texturing 공정이 길어질수록 불안정한 pn-junction을 형성하는 것을 확인하였으며, emitter 층 형성 후 PSG (phosphorous silica glass) 공정에서 needle의 상부 구조가 무너지면서 면저항이 증가된 결과로 분석된다. PSG 제거 후 측정된 면저항의 경우 3분 texturing 샘플부터 면저항이 약 4${\Omega}/sq$ 정도 증가됨을 확인하였다.

  • PDF

Determinations of the Exposure Rate Using a NaI(Tl) Detector of the Environmental Radiation Monitor (환경방사선감시기의 NaI(Tl) 검출기를 이용한 조사선량률 결정방법)

  • Ji, Young-Yong;Lee, Wanno;Choi, Sang-Do;Chung, Kun Ho;Kang, Mun Ja;Choi, Geun-Sik
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.11 no.3
    • /
    • pp.245-251
    • /
    • 2013
  • The energy band and the G-factor method were compared to determine the exposure rate from the measured spectrum using a NaI(Tl) scintillation detector. First, G-factors of a 3"${\Phi}X3$" NaI(Tl) detector mounted to a EFRD 3300, which means the environmental radiation monitor, in Korea Atomic Energy Research Institute (KAERI) were calculated for several directions of incident photons through the MCNP modeling, and the optimum G-factor applicable to that monitor was then determined by comparing the results both the energy band method and the G-factor method. The results for these spectrometric determinations were also compared with the dose rate from a HPIC radiation monitor around a EFRD 3300. The measured value at the EFRD 3300 based on a 3"${\Phi}X3$" NaI(Tl) detector was $7.7{\mu}R/h$ and its difference was shown about $3{\mu}R/h$, when compared with the results from a HPIC radiation moditor. Since a HPIC is known to be able to measure cosmic rays with the relatively high energy, the difference between them was caused by cosmic rays which were not detected in a 3"${\Phi}X3$" NaI(Tl) detector.

The Clinical Effect and Construction of a Stereotactic Whole Body Immobilization Device (전신 정위 고정장치 제작과 임상효과에 대한 연구)

  • 정진범;정원균;서태석;최경식;진호상;지영훈
    • Progress in Medical Physics
    • /
    • v.15 no.1
    • /
    • pp.30-38
    • /
    • 2004
  • Purpose: To develop a whole body frame for the purpose of reducing patient motion and minimizing setup error for extra-cranial stereotactic radiotherapy, and to evaluate the repositioning setup error of a patient in the frame. Materials and Methods: The developed whole body frame is composed of a base plate, immobilizer, vacuum cushion, ruler and belts. The dimension of the base plate is 130 cm in length, 50 cm in width and 1 cm in thickness. The material used in the base plate of the frame was bakelite and the immobilizer was made of acetal. In addition, Radiopaque angio-catheter wires were engraved on the base plate for a coordinate system to determine the target localization. The measurement for radiation transmission and target localization is peformed in order to test the utilization of the frame. Also, a Matlab program analyzed the patients setup error by using the patient's setup images obtained from a CCTV camera and digital record recorder (DVR). Results: A frame that is useful for CT simulation and radiation treatment was fabricated. The frame structure was designed to minimize collisions from the changes in the rotation angle of the gantry and to maximize the transmission rate of the Incident radiation at the lateral or posterior oblique direction. The lightening belts may be used for the further reduction of the patient motion, and the belts can be adjusted so that they are not in the way of beam direction. The radiation transmission rates of this frame were measured as 95% and 96% at 10 and 21 MV, respectively. The position of a test target on the skin of a volunteer is accurately determined by CT simulation using the coordinate system in the frame. The estimated setup errors by Matlab program are shown 3.69$\pm$1.60, 2.14$\pm$0.78 mm at the lateral and central chest, and 7.11 $\pm$2.10, 6.54$\pm$2.22 mm at lateral and central abdomen, respectively. The setup error due to the lateral motion of breast is shown as 6.33$\pm$ 1.55 mm. Conclusion: The development and test of a whole body frame has proven very useful and practical in the radiosurgery for extra-cranial cancers. It may be used in determining target localization, and it can be used as a patient immobilization tool. More experimental data should be obtained in order to improve and confirm the results of the patient setup error.

  • PDF

Characteristics in the Deposition of Mn-Zn Ferrite Thin Films by Ion Beam Sputtering Using a Single Ion Source (단일 이온원을 사용하는 이온빔 스퍼터링법에 의한 Mn-Zn 페라이트 박막의 증착 기구)

  • Jo, Hae-Seok;Ha, Sang-Gi;Lee, Dae-Hyeong;Hong, Seok-Gyeong;Yang, Gi-Deok;Kim, Hyeong-Jun;Kim, Gyeong-Yong;Yu, Byeong-Du
    • Korean Journal of Materials Research
    • /
    • v.5 no.2
    • /
    • pp.239-245
    • /
    • 1995
  • Mn-Zn ferrite thin films were deposited on $SiO_2(1000 \AA)/Si(100)$ by ion beam sputtering using a single ion source. A mosaic target consisting of a single crystal(ll0) Mn-Zn ferrite with a Fe metal strip on it was used. As-deposited films without oxygen gas flow have a wiistite structure due to oxygen deficiencies, which originated from the extra metal atoms sputtered from the metal strips during deposition. The as-deposited films with oxygen gas flow, however, have a spinel structure with (111) preferred orientation. The crystallization of thin films was maximized at the ion beam extraction voltage of 2.lkV, at which the deposited films are bombarded appropriately by the energetic secondary ions reflected from the target. As the extraction voltage increased or decreased from the optimum value, the crystallinity of thin films becomes poor owing to a weak and severe bombardment of the secondary ions, respectively. Crystallization due to the bombardment of the secondary ions was also maximized at the beam incidence angle of $55^{\circ}$. The as-deposited ferrite thin films with a spinel structure showed ferrimagnetism and had an in-plane magnetization easy axis.

  • PDF

Usability Evaluation of Lateral Sliding Table in CT Examination (CT 검사에서 Lateral Sliding Table의 유용성 평가)

  • Choi, Jeong Hun;Kong, Chang gi;Song, Jong Nam;Han, Jae Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.677-684
    • /
    • 2020
  • Miscentering in the left and right X axis direction during CT examination affects dose and quality. When the CT Gantry Isocenter and the center of the examination objective are matched using the Lateral Sliding Table, the image quality is improved and the exposure dose is reduced. CTDI Head Phantom (Kimda, Korea) and dosimeter (Ray Safe, Sweden) were used to measure dose comparison CTDI (mGy) due to center deviation, and Water Phantom (HITACHI, Japan) was used to measure noise to see the difference in uniformity due to center deviation. Measurements of doses for dose comparison CTDI (mGy) with a deviation showed that doses were consistently reduced and exact dose was not projected until they were moved to 80 mm by 20 mm from the Isocenter. SD values were measured to see the difference in uniformity due to center deviation and the noise continued to increase until it was moved by 20 mm to 80 mm. The range of collimation has increased by the extent of deviating from the center and the range of exposure has increased. Using the Lateral Sliding Table, you can easily adjust the Isocenter, increase the quality of the image by adjusting the Isocenter in areaa such as the cardiac examination of the location away from the Isocenter, Extreme bone and Shoulder, and greatly reduce the collimation to the Isocenter, so it can be used to reduce unnecessary exposure dose.

Verification of Target Position in Stereotactic Radiosurgery Based on Photon Knife System (Photon Knife 시스템에 근거한 뇌정위 방사선수술에서 표적위치 확인)

  • 최태진;김진희;김옥배
    • Progress in Medical Physics
    • /
    • v.14 no.2
    • /
    • pp.99-107
    • /
    • 2003
  • This study was performed to prepare the verification film for localizing beam-target position with the Photon Knife radiosurgery system (PKRS) using linear accelerator(Mitsubishi, Model ML-15MDX). We developed a laser calibration system using a reticle of transparent lucite to detect Inlet and outlet beams. We verified fixation of the second collimator with film mounted on a holder in the shape of an octagon block 5cm apart from the isocenter. The film was exposed to photon beams of linear accelerator at an interval of 45 degrees during the gantry movement. There were no shifts in the beam of the second collimator during gantry movement. We used a position marker which is designed a head-shaped small lead block and a 10 mm in diameter of steel bead in the plastic tube. The position marker helped to verify the beam directions with patient position in multi-arc and trans-multi-arc of PKRS The verification of beam alignments showed an average 0.8$\pm$0.26 mm discrepancy in LINAC-gram images of PKRS. In our study, the couch movement was $\pm$5 mm laterally, while it shook $\pm$ 2 mm toward the couch axis. The couch, however, was immediately returned to the initial site after shaking. Thus, we postulate that the beam-target position(s) should be verified with LINAC-gram in a stereotactic radiosurgery system to achieve the accuracy of beam-target alignment.

  • PDF

Assessment of Effective Dose from Diagnostic X-ray Examinations of Adult (진단X선에 의한 성인의 진단행위별 유효선량평가)

  • Kim, Woo-Ran;Lee, Choon-Sik;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.3
    • /
    • pp.155-164
    • /
    • 2002
  • Methodology to evaluate the effective doses to adults undergoing various diagnostic x-ray examinations were established by Monte Carlo simulation of the x-ray examinations. Anthropomorphic mathematical phantoms, the MIRD5 male phantom and the ORNL female phantom, were used as the target body and x-ray spectra were produced by the x-ray spectrum generation code SPEC78. The computational procedure was validated by comparing the resulting doses to the results of NRPB studies for the same diagnostic procedures. The effective doses as well as the organ doses due to chest, abdomen, head and spine examinations were calculated for x-rays incident from AP, PA, LLAT and RLAT directions. For instance, the effective doses from the most common procedures, chest PA and abdomen AP, were 0.029 mSv and 0.44 mSv, respectively. The fact that the effective dose from PA chest x-ray is far lower than the traditional value of 0.3 mSv(or 30 mrem), which results partly from the advances of technology in diagnostic radiology and partly from the differences in the dose concept employed, emphasizes necessities of intensive assessment of the patient doses in wide ranges of medical exposures. The methodology and tools established in this study can easily be applied to dose assessments for other radiology procedures; dose from CT examinations, dose to the fetus due to examinations of pregnant women, dose from pediatric radiology.