• Title/Summary/Keyword: 임상 평가

Search Result 4,601, Processing Time 0.035 seconds

Effect of abutment superimposition process of dental model scanner on final virtual model (치과용 모형 스캐너의 지대치 중첩 과정이 최종 가상 모형에 미치는 영향)

  • Yu, Beom-Young;Son, Keunbada;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.203-210
    • /
    • 2019
  • Purpose: The purpose of this study was to verify the effect of the abutment superimposition process on the final virtual model in the scanning process of single and 3-units bridge model using a dental model scanner. Materials and methods: A gypsum model for single and 3-unit bridges was manufactured for evaluating. And working casts with removable dies were made using Pindex system. A dental model scanner (3Shape E1 scanner) was used to obtain CAD reference model (CRM) and CAD test model (CTM). The CRM was scanned without removing after dividing the abutments in the working cast. Then, CTM was scanned with separated from the divided abutments and superimposed on the CRM (n=20). Finally, three-dimensional analysis software (Geomagic control X) was used to analyze the root mean square (RMS) and Mann-Whitney U test was used for statistical analysis (${\alpha}=.05$). Results: The RMS mean abutment for single full crown preparation was $10.93{\mu}m$ and the RMS average abutment for 3 unit bridge preparation was $6.9{\mu}m$. The RMS mean of the two groups showed statistically significant differences (P<.001). In addition, errors of positive and negative of two groups averaged $9.83{\mu}m$, $-6.79{\mu}m$ and 3-units bridge abutment $6.22{\mu}m$, $-3.3{\mu}m$, respectively. The mean values of the errors of positive and negative of two groups were all statistically significantly lower in 3-unit bridge abutments (P<.001). Conclusion: Although the number of abutments increased during the scan process of the working cast with removable dies, the error due to the superimposition of abutments did not increase. There was also a significantly higher error in single abutments, but within the range of clinically acceptable scan accuracy.

A Study of Improvement of Skin Condition and Sensory Efficacy by Periodic Application of L-α-Amino Acid (L-α-아미노산의 주기적 도포에 의한 피부개선 효능과 소비자 체감 효능 연구)

  • Kwon, Koo Chul;Lee, Sung Woo;Ahn, Byungjun;Kang, Nae-Gyu;Park, Sun Gyoo;Park, Sang Wook
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.45 no.1
    • /
    • pp.9-17
    • /
    • 2019
  • In this study, $L-{\alpha}-amino$ acid, which is a constituent of natural moisturizing factor, was applied to skin in periodic cycle to improve skin tone and texture roughness. Based on the polarity of the alkyl group (R) of the $L-{\alpha}-amino$ acid, the acid was categorized into two groups and their efficacy was studied. As a result, it was found that the improvement rate of $L-{\alpha}-amino$ acid complex with polar alkyl group ($L-{\alpha}-AAC-1$) is 21% higher than that of $L-{\alpha}-amino$ acid complex with non-polar alkyl group ($L-{\alpha}-AAC-2$). For clinical trials, emulsions containing $L-{\alpha}-amino$ acid complex ($L-{\alpha}-AAC-1$) were applied to the randomly selected 20 to 40 year old female participants, as an experimental group, on the right facial cheek once per day for 8 weeks, and emulsions without $L-{\alpha}-amino$ acid complex, as a control group, were applied to the left facial cheek in the same way. Improvements in skin tone were measured using $JANUS^{(R)}$ equipment and analyzed using image analysis software. Skin texture improvement was measured and analyzed mechanically using the phaseshift rapid in-vivo measurement of the skin (PRIMOS) equipment. As a result, improvements of skin tone and skin texture were 11.7% and 6.7%, respectively. In addition, a questionnaire survey was conducted to the participants on the aesthetic improvement and the degree of the feeling of skin improvement. The results suggest that $L-{\alpha}-amino$ acid can be used as a cosmetic substance that can provide aesthetic satisfaction through physiological skin tone and texture roughness.

Evaluation of static fracture resistances and patterns of pulpless tooth restored with poly-ether-ketone-ketone (PEKK) post (Poly-ether-ketone-ketone (PEKK) 포스트로 수복한 근관 치료 치아의 정적 파절 저항성 및 파절 형태에 관한 평가)

  • Park, Ha Eun;Lee, Cheol Won;Lee, Won Sup;Yang, Sung Eun;Lee, Su Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.2
    • /
    • pp.127-133
    • /
    • 2019
  • Purpose: The purpose of present study was to investigate fracture strength and mode of failure of endodontically treated teeth restored with metal cast post-core system, prefabricated fiber post system, and newly introduced polyetherketoneketone (PEKK) post-core system. Materials and methods: A total of 21 mandibular premolar were randomly grouped into 3 groups of 7 each according to the post material. Group A was for metal cast post core; Group B for prefabricated glass fiber post and resin core; and Group C for milled PEKK post cores. All specimens were restored with metal crown. The fracture strength of each specimen was measured by applying a static load of 135-degree to the tooth at 2 mm/min crosshead speed using a universal testing machine. After the fracture strength measurement, the mode of failure was observed. The results were analyzed using Kruscal-Wallis test and post hoc Mann-Whitney U test at confidence interval ${\alpha}=.05$. Results: Fracture resistance of PEKK post core was lower than those of cast metal post and fiber reinforced post with composite resin core. In the aspect of fracture mode most of the root fracture occurred in the metal post core, whereas the post detachment occurred mainly in the fiber reinforced post. In the case of PEKK post core, teeth and post were fractured together. Conclusion: It is necessary to select appropriate materials of post for extensively damaged teeth restoration and clinical application of the PEKK post seems to require more research on improvement of strength.

Degree of Conversion and Polymerization Shrinkage of Low and High Viscosity Bulk-Fill Giomer-based and Resin-based composites (저점도 및 고점도 Bulk-fill Giomer 복합레진과 Bulk-fill 복합레진의 전환율과 중합수축)

  • Kim, Heera;Lee, Jaesik;Kim, Hyunjung;Kwon, Taeyub;Nam, Soonhyeun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.46 no.1
    • /
    • pp.1-9
    • /
    • 2019
  • The aim of this study was to compare the degree of conversion and polymerization shrinkage of low and high viscosity bulk-fill giomer-based and resin-based composites. Two bulk-fill giomer (Beautifil Bulk Restorative (BBR), Beautifil Bulk Flowable (BBF)), two bulk-fill (Tetric N-Ceram Bulk-fill (TBF), SureFil SDR flow (SDR)) and two conventional resin composites (Tetric N-Ceram (TN), Tetric N-flow (TF)) were selected for this study. The degree of conversion was measured by using Fourier transform infrared spectroscopy. Polymerization shrinkage was measured with the linometer. For all depth, BBR had the lowest degree of conversion and SDR had the highest. At 4 mm, the degree of conversion of low and high viscosity bulk-fill giomer resin composites was lower than that of bulk-fill resin composites (p < 0.05). At the depth between 2 mm and 4 mm, there were significant difference with TBF, TN and TF (p < 0.05), while no significant difference in the degree of conversion was measured for BBR, BBF and SDR. Polymerization shrinkage of six resin composites decreased in the following order: TF > SDR > BBF > TBF > TN and BBR (p < 0.05). Polymerization shrinkage of bulk-fill giomer resin composites was lower than that of bulk-fill resin composites (p < 0.05). From this study, it is found that the bulk-fill giomer resin composites and TBF were not sufficiently cured in 4 mm depth. The degree of conversion of low and high viscosity bulk-fill giomer resin composites was significantly lower than bulk-fill resin composites in both 2 mm and 4 mm depths. Therefore, such features of bulk-fill giomer resin composites should be carefully considered in clinical application.

Evaluation of sleep quality and stress response in patients requiring dental prosthetic treatment (치과보철치료를 요하는 환자에서의 수면질과 스트레스 반응 평가)

  • Jeon, Hye-Mi;Jung, Kyoung-Hwa;Choi, Na-Rae;Song, Jae-Min;Lee, So-Hyoun;Kim, So-Yeun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.2
    • /
    • pp.181-189
    • /
    • 2021
  • Purpose: The purpose of this study is to investigate the stress response and sleep state of the new patients who visit the hospital for prosthodontic treatment due to tooth loss to make reference to further treatment direction. Materials and methods: Examinations, consultations, and surveys were conducted on 236 patients (94 males, 142 females, and 24-86 years old), who newly registered at the department of prosthodontics at Pusan national university hospital, for 2 years from 2018. The number of remaining teeth, edentulous arch, possibility of mastication, and future prosthetic treatment directions were recorded. The visual analogue scale (VAS), stress response inventory (SRI) and Insomnia severity index (ISI) were used as tools to measure patient's subjective discomfort, stress response, and sleep status. Results: Among the entire prosthodontic patient group, the average value of 'fatigue' was significantly higher among the 7 items of SRI, and the value of 'aggression' was significantly lower (P<.001). There are a significant difference between the edentulous and full dentition in the oral discomfort value measured by VAS (P=.004). In cases where less than 20 teeth remain, mastication is impossible, and patients who are planning treatment with removable prostheses, VAS value and 'depression' and 'fatigue' values in SRI were higher than those in the reverse case (P<.05). The patients showed severe level in VAS value have high value of 'tension', 'somatization', 'depression', 'fatigue'and 'frustration'in SRI than non-serious patients (P<.05). Clinical insomnia occurred in 11.4% of all patients, and women had significantly lower sleep quality than men (P=.044). Patients with insomnia showed significantly higher scores on the VAS value and all 7 SRI items than those of normal sleepers (P<.05). Conclusion: The new prosthetics had high 'fatigue' value among the 7 items of SRI. The oral condition, number of residual teeth and mastication function and clinical insomnia affected oral discomfort and the stress response.

A Study of Waterproofing Evaluation and Effect of UV Protection (UVB/UVA) of Multiple Emulsion Sunblock Cream using Sensory Engeeneering Science (감성공학을 적용한 다중에멀젼 선블록크림의 자외선차단(UVA/B) 효과와 내수성 평가 연구)

  • Kim, In-Young
    • Journal of the Korean Applied Science and Technology
    • /
    • v.37 no.6
    • /
    • pp.1517-1527
    • /
    • 2020
  • This study is about the UV protection effect and water resistance of a multiple emulsion (W/O/W) sunblock cream applied with emotional engineering and reports an actual industrial case. Multiple emulsion system of sunblock cream has the characteristics of changing to a W/O type that is soft and moist when applied, and has excellent water resistance after absorption. Multiple emulsion cream is a highly functional sunblock cream that has both moisture and water resistance. It is a stable milky white cream with a viscosity of 36,000 cps. The organic sunscreen used for the sunscreen was ethylhexylmethoxycinnamate and bisethylhexyloxyphenolmethoxyphenyltriazine. Hexagonal zinc oxide and titanium dioxide that block both UVB and UVA were used. As a result of measuring the UV protection effect by the in-vitro method, the UV protection effect (SPF) is 78.9 for multiple emulsion cream, 76.7 for W/O cream, and 71.3 for O/W cream. It was found that the blocking effect was different. This obtained the highest effect value in the multiple emulsion. As a clinical (in-vivo) result of the UV protection effect, the SPF value representing the UV protection effect of the sunblock cream developed with a multiple emulsion system was 85.7, and the PA-value that blocks the UVA area was 26.5, and ++++. It was found that it has a corresponding high blocking effect. As a result of the water resistance test, the W/O/W formulation had a high waterproofing resistance of 93.8% even after 4 hours, W/O had 75.4%, and O/W had a low water resistance of 25.3%. In the results of the HUT test, it was found in the order of multiple emulsion sun block cream > hydrophilic cream > lipophilic cream. Based on the research results of this multiple emulsion, it is expected to be highly active as a sunblock cream dedicated to outdoor activities by improving the feeling of use, UV protection index, and water resistance. Therefore, in this study, a multiple emulsion system of sunblock cream is developed and has a characteristic that changes to a W/O type that has a soft and moist feeling when applied, and has excellent water resistance after absorption.

Marginal and internal fit of interim crowns fabricated with 3D printing and milling method (3D 프린팅 및 밀링 방법으로 제작된 임시 보철물 적합도 비교 분석)

  • Son, Young-Tak;Son, KeunBaDa;Lee, Kyu-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.4
    • /
    • pp.254-261
    • /
    • 2020
  • Purpose: The purpose of this study was to assess the marginal and internal fit of interim crowns fabricated by two different manufacturing method (subtractive manufacturing technology and additive manufacturing technology). Materials and Methods: Forty study models were fabricated with plasters by making an impression of a master model of the maxillary right first molar for ceramic crown. On each study model, interim crowns (n = 40) were fabricated using three types of 3D printers (Meg-printer 2; Megagen, Zenith U; Dentis, and Zenith D; Dentis) and one type milling machine (imes-icore 450i; imes-icore GmbH). The internal of the interim crowns were filled with silicon and fitted to the study model. Internal scan data was obtained using an intraoral scanner. The fit of interim crowns were evaluated in the margin, absolute margin, axial, cusp, and occlusal area by using the superimposition of 3D scan data (Geomagic control X; 3D Systems). The Kruskal-wallis test, Mann-Whitney U test and Bonferroni correction method were used to compare the results among groups (α = 0.05). Results: There was no significant difference in the absolute marginal discrepancy of the temporary crown manufactured by three 3D printers and one milling machine (P = 0.812). There was a significant difference between the milling machine and the 3D printer in the axial and occlusal area (P < 0.001). The temporary crown with the milling machine showed smaller axial gap and higher occlusal gap than 3D printer. Conclusion: Since the marginal fit of the temporary crown produced by three types of 3D printers were all with in clinically acceptable range (< 120 ㎛), it can be sufficiently used for the fabrication of the temporary crown.

Extract of Fructus Corni Ameliorates Testosterone-induced Benign Prostatic Hypertrophy in Sprague Dawley Rats (산수유 추출물에 의한 testosterone으로 유발된 양성 전립선 비대증의 개선)

  • Ji, Seon Yeong;Kim, Min Yeong;Hwangbo, Hyun;Lee, Hyesook;Hong, Su Hyun;Kim, Tae Hee;Yoon, Seonhye;Kim, Hyun Jin;Jung, Ha Eun;Kim, Sung Yeon;Kim, Tae Jung;Kim, Min Ji;Kim, Sung Ok;Choi, Yung Hyun
    • Journal of Life Science
    • /
    • v.31 no.6
    • /
    • pp.550-558
    • /
    • 2021
  • Fructus Corni, the fruit of Cornus officinalis, has long been used for the prevention and treatment of various diseases. We recently suggested that it was effective against benign prostatic hyperplasia (BPH). In this study, we investigated the inhibitory effect of Corni Fructus (CF) water extract on BPH induced by testosterone propionate (TP) in noncastrated and castrated animal models. BPH was induced in Sprague Dawley rats by an intramuscular injection of TP in castrated or noncastrated rats. Finasteride (FINA) treatment was used as a positive control for inhibition of BPH. According to our results, CF administration inhibited excessive enlargement of development of the prostate in both the noncastrated and castrated groups compared to the control and FINA-treated groups. The inhibitory effect of CF on BPH was associated with inhibition of expression of hypoxia-inducible factor-1α, 5α-reductase type 2, steroid receptor coactivator-1, androgen receptor (AR), and prostate-specific antigen. Serum levels of the stress hormone cortisol increased during BPH induction by TP in both the noncastrated and castrated groups, but they were attenuated significantly by CF administration. However, insulin and IGF-1 levels were not increased in the BPH-induced groups and CF, and no effective results were found by CF administration. These results point to a beneficial effect of CF on BPH through inhibition of AR signaling pathway activity and imply that CF shows excellent potential as a therapeutic agent for the prevention and treatment of BPH.

Clinical Results of Lateral-Posterior Internal Fixation for the Treatment of Scapular Body Fractures (견갑골 체부 골절에서 외측 후방 금속판 고정술의 치료 결과)

  • Lee, Yoon-Min;Yeo, Joo-Dong;Song, Seok-Whan
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.1
    • /
    • pp.46-53
    • /
    • 2020
  • Purpose: Scapular body fractures have generally been treated with non-surgical methods. This study reports the clinical and radiological outcomes after lateral-posterior internal fixation for treating displaced scapular body fractures. Materials and Methods: From March 2007 to May 2017, out of 40 patients who underwent internal fixation for scapular fractures, 13 cases of lateral plate fixation of a scapular body fracture were reviewed retrospectively. Preoperative and postoperative displacement, angulation and glenopolar angle (GPA) were measured. The range of shoulder motion, visual analogue scale (VAS), and disabilities of the arm, shoulder, and hand (DASH), and Constant score were assessed at the last follow-up. Results: The mean follow-up period was 17.7 months (range, 6-45 months). The mean preoperative GPA was 23.3°±3.96° (range, 17.8°-28.1°) and the postoperative GPA was 31.1°±4.75° (range, 22.5°-40.1°). Injury to the suprascapular nerve, nonunion, fracture redisplacement, metallic failure, or infection did not occur. At the last follow-up, the mean range of motion was 150.5°±19.3° in forward flexion, 146.6°±2.34° in lateral abduction, 66.6°±19.1° in external rotation, and 61.6°±18.9° in internal rotation. The VAS, DASH, and Constant scores were 1.7±1.3, 6.2±2.4, and 86±7.9 points, respectively. Conclusion: A scapular body fracture with severe displacement, angulation and marked decreased GPA can be stabilized by lateralposterior plate fixation using the appropriate surgical technique with good functional and radiological results.

Anti-obesogenic Effect of Brassica juncea Extract on Bisphenol-A Induced Adipogenesis of 3T3-L1 Cells (비스페놀 A (Bisphenol-A)로 유도된 지방세포 분화에 미치는 갓 추출물의 항오비소겐 효과)

  • Lee, Se-jeong;Na, Uoon-Joo;Choi, Sun-Il;Han, Xionggao;Men, Xiao;Lee, Youn Hwan;Kim, Hyun Duk;Kim, Yoon Jung;Lee, Ok-Hwan
    • Journal of Food Hygiene and Safety
    • /
    • v.36 no.6
    • /
    • pp.528-536
    • /
    • 2021
  • The purpose of the study was to investigate the content of sinigrin, an index component, in Brassica juncea extract and to evaluate the differentiation of lipocytes, inhibition of production of reactive oxygen species (ROS) and reduction of protein production by lipogenic factors (PPARγ, C/EBPα, aP2) in the processing of Brassica juncea extract and sinigrin in 3T3-L1 preadipocytes which induces Bisphenol A (BPA), an endocrine disrupting environmental hormone. From the investigation, the content of sinigrin in Brassica juncea extract, measured by HPLC, is found to be 21.27±0.2 mg/g. The XTT assay result on BPA-derived 3T3-L1 adipocytes shows there is no cytotoxicity found from 180 µM of sinigrin and 300 ㎍/mL of Brassica juncea extract. Moreover, both intracellular lipid accumulation and ROS production during differentiation of lipocyte are significantly reduced in cells processed with Brassica juncea extract and sinigrin. Lastly, it was also found that the production of transcription factors of lipocyte differentiation, PPARγ, C/EBPα and aP2, were found to be suppressed by the application of Brassica juncea extract and sinigrin. Such results reveals that Brassica juncea is effective in not only suppressing lipid accumulation in the environmental hormone bisphenol A-derived lipocyte, but also in reducing the ROS. The sinigrin-containing Brassica juncea is highly expected to be used in natural functional supplements that prevents the lipid metabolism disorders caused by BPA. There are necessities for additional clinical research and follow-up studies on the in vivo model to verify the relevant mechanisms.