• Title/Summary/Keyword: 임상치위생

Search Result 396, Processing Time 0.02 seconds

Comparative Study of Dental Plaque Reduction according to Various Mouthwashes Using Quantitative Light Induced Fluorescence-Digital (Quantitative Light Induced Fluorescence Digital을 이용한 수종의 구강양치액의 치면세균막 감소효과에 대한 비교연구)

  • Lee, Sae-Rom;Kim, Jae-Hong;Huh, Sungyoon
    • Journal of dental hygiene science
    • /
    • v.13 no.4
    • /
    • pp.434-439
    • /
    • 2013
  • This study was conducted to compare the dental plaque reduction using various mouthwashes with Quantitative Light induced Fluorescence-Digital (QLF-D). A survey on 20 students was carried out. The students who were at Shingu College. Experimental group was gargled 20 ml of Listerine during 30 seconds and 15 ml of Hexamedine during 60 seconds. Control group was gargled distilled water during 30 second. The data were analyzed with t-test using SPSS 20.0 program. The ratios of control group and experimental group were reduced. Degree of ${\Delta}R30$ and ${\Delta}R70$ Listerine group was a significant difference (p>0.05). Degree of Simple Plaque Score and ${\Delta}R30$ Hexamedine group was a significant difference (p>0.05). There was no significant difference in the distilled water gargle group (p<0.05). The result of this study has the effect of two mouthwashes reduced dental plaque. The evaluation data of this study will be used in clinical application and research about QLF-D.

Regenerative Endodontic Procedure in Korean Children and Adolescents: A Case Report (한국 소아청소년 근관치료 영역에서 재생치료, 근관치료재생술에 대한 증례보고)

  • An, So-Youn;Kim, Jin-Kyoung;Shim, Youn-Soo
    • Journal of dental hygiene science
    • /
    • v.16 no.4
    • /
    • pp.317-322
    • /
    • 2016
  • Mineral trioxide aggregate (MTA) is widely used in endodontic therapy as a pulp-capping material, root or furcal perforation repair material, and for apexification and obturation of the root canal system. The purpose of this study was to formally document cases of MTA application in South Korean children and adolescents. Through this research, the practice of using MTA will be introduced and familiarized to the clinical practitioners. This study involved endodontic treatment using MTA for fractured crowns in 11- and 12-year-old. The children were followed up for 12 months until the pulp vitality was confirmed; in young permanent teeth with immature roots, the pulp is integral to the process of apexogenesis. These observational results regarding the use of MTA as an apexification material in non-vital immature permanent incisors appear to provide promising results in the search for new materials to meet existing endodontic needs.

Comparison of Tooth Whitening Efficacy between Gel and Strip with Light Activator (광을 이용한 2.9% 과산화수소 함유 젤과 첩부제의 치아미백효과 비교)

  • Kim, Ji-Hye;Bang, Seong-Eun;Kim, Ji-Young;Ahn, Jae-Hyun
    • Journal of dental hygiene science
    • /
    • v.17 no.6
    • /
    • pp.481-486
    • /
    • 2017
  • The study aimed to compare the whitening efficacy of a strip and gel containing 2.9% hydrogen peroxide, using a tooth whitening light activator. The whitening effect was compared through in vitro and in vivo studies. In the in vitro study, we used stained hydroxyapatite (HAP) specimens as artificial teeth. HAP specimens were made using HAP powder and polyvinyl alcohol solution, and stained by modified Stookey's method. A whitening gel and whitening strip were applied to the respective specimens for 20 minutes, with a light activator. The color changes were measured using a colorimeter. In the in vivo study, one group (test 1) used the gel with a light activator and the other group (test 2) used a strip with the same activator for 15 minutes a day, for four consecutive days. An organoleptic evaluation using a Vita shade guide and instrumental evaluation using a Shade eye-NCC (Shofu Co., Japan) were performed. The color change values (${\Delta}E^*$) in the in vitro study revealed the strip with the light activator to be more effective than the gel with the same activator (p<0.001). In the in vivo study, even though there was no significant difference between the groups with respect to the ${\Delta}E^*$, using either the Shade eye-NCC or the Vita shade guide, the change in yellowness (${\Delta}b^*$) was statistically significant (p=0.024). In conclusion, test 2 group that used 2.9% hydrogen peroxide strip with a light activator, showed a tendency towards increased whitening than test 1 group that used the gel with the same activator; however further studies are needed to validate the above finding.

Bacterial Contamination of Dental Unit Water Systems in a Student Clinical Simulation Laboratory of College of Dentistry (치과대학 임상 시뮬레이션 실습실 치과용 유니트 수계의 세균 오염도 조사)

  • Yoon, Hye Young;Lee, Si Young
    • Journal of dental hygiene science
    • /
    • v.15 no.2
    • /
    • pp.232-237
    • /
    • 2015
  • The water supplied from dental unit water systems (DUWS) in dentistry may be heavily contaminated with bacteria and thus may be a potential source of infection for both practice staff and patients. The aim of this study was to evaluate the level of heterotrophic bacteria and to confirm the presence of opportunistic pathogens from DUWS in student clinical simulation laboratory of college of dentistry. Water samples were collected from 36 ultrasonic scalers in student clinical simulation laboratory. The levels of heterotrophic bacteria in water samples were quantified by counting colony forming units (CFUs) on R2A agar media. In addition, opportunistic pathogens were detected by using the polymerase chain reaction (PCR) method. The mean CFUs were 16,095 CFU/ml for water samples and all of water samples exceeded current American Dental Association recommendations of 200 CFU/ml. Pseudomonas species and non-tuberculous Mycobacterium species were detected in the one sample and two samples, respectively, among the 36 water samples by the PCR with specific primers for these bacteria. Our study indicated that DUWS in student clinical simulation laboratory can cause potential infection in students and participants. This study suggested the dental unit water line management and wearing personal protective equipment in student clinical simulation laboratory will be needed to reduce bacterial contamination.

Effect of Porcelain Firing Process on the Marginal and Internal Fit of Ni-Cr Alloy Metal-Ceramic Crown (도재 소성과정이 Ni-Cr 금속도재관의 변연 및 내면 적합도에 미치는 영향)

  • Kim, Ki-Baek;Kim, Seok-Hwan;Kim, Jae-Hong
    • Journal of dental hygiene science
    • /
    • v.14 no.3
    • /
    • pp.405-410
    • /
    • 2014
  • The purpose of this study in vitro investigation was to compare the marginal and internal fit of Ni-Cr alloy metal ceramic crown before and after porcelain veneering. Furthermore, this study evaluated whether the influence of the porcelain firing on the precision of fit of dental prostheses. The maxillary right incisor was selected as an abutment for experiments. Ten working models were prepared. Ni-Cr alloy cores appropriate for each abutment were prepared by lost wax technique. The marginal area and four internal areas of the crowns were measured at two stages: before veneering process and after upper porcelain firing. Silicone replica techniques were used. The data were statistically analyzed with the paired t-test (${\alpha}=0.05$). $Mean{\pm}SD$ marginal and internal gap were $67.1{\pm}23.3{\mu}m$ for the nickle chrome alloy core group and $74.4{\pm}21.9{\mu}m$ for the metal ceramic crown group. There were statistically significant differences in all investigated areas (p<0.05). Within the limitations of this study, none of the Ni-Cr alloy metal crown values measured after porcelain firing process exceeded $120{\mu}m$, which is the clinically acceptable threshold.

The Influence of Different Gypsum Materials on the Accuracy from Complete Arch Digital Impression (전악의 디지털 인상 채득 시 치과용 모형재가 디지털 모형 정확성에 미치는 영향)

  • Kim, Ki-Baek;Lee, Gyeong-Tak;Kim, Hae-Young;Kim, Jae-Hong
    • Journal of dental hygiene science
    • /
    • v.12 no.6
    • /
    • pp.617-623
    • /
    • 2012
  • This study was performed to measure the accuracy of different gypsum materials by a white light dental scanner. A master model with the prepared lower full arch tooth was used. The type IV and scannable stone were used for 20 stone casts (10 casts each) duplicated a master model of mandible. The distance between the reference points were measured and analyzed by the Delcam $Copycad^{(R)}$ (Delcam Plc, UK) 3D graphic software. The t-student test for paired samples were used for statistical analysis. The mean differences to master model for type IV stone and scannable stone model were 0.29~0.56 mm, and 0.17~0.35 mm, respectively. There were statistical differences in dimensional accuracy for full arch impression between the master model and type IV/scannable stone (p<0.05). Two different gypsum materials showed clinically acceptable accuracies of full arch digital impression produced by them. Besides, in both gypsum materials, the differences to the master model detected appear to provide enough accuracy for clinical application.

The effect of dental hygiene students' knowledge and attitude toward the elderly on the discrimination of the elderly (치위생학과 학생들의 노인에 대한 지식 및 태도가 노인차별주의에 미치는 영향)

  • Young-Sun Kim;Jung-Hwa Lee
    • Journal of Korean Dental Hygiene Science
    • /
    • v.6 no.2
    • /
    • pp.129-139
    • /
    • 2023
  • Background: The elderly population aged 65 or older in Korea is expected to continue to increase to 18.4% in 2023, and to enter a super-aged society at 20.6% in 2025. In clinical practice, the elderly discrimination of dental hygienists may experience difficulties during dental hygiene treatment due to an increase in the number of elderly patients due to aging, which can lead to maladjustment to work and turnover, so education on the understanding of the elderly is essential for students in the Department of Dentistry, who are prospective dental hygienists. Accordingly, a study was conducted to prepare for a super-aged society by studying the relationship between elderly discrimination and the knowledge and attitudes of the elderly, and to change the curriculum of universities and develop programs related to the elderly. Method: 204 students enrolled in the Department of Dentistry in D area were analyzed using the SPSS/WIN 25.0 program. The subject's geriatric discrimination, knowledge about the elderly, and attitude toward the elderly were calculated as the mean and standard deviation. T-test and one-way ANOVA were performed to verify the difference in geriatric discrimination according to the general characteristics of the subject, with a Scheffe' test applied for post-hoc analysis. Correlation analysis was conducted on the subject's geriatric discrimination, knowledge about the elderly, and attitudes toward the elderly. Results: Geriatrics scored 2.03±0.36 out of 4. Knowledge about the elderly was categorized as follows: physical domain 0.57±0.15; social domain 0.36±0.17; and psychological domain 0.35±0.20. The attitude toward the elderly was 3.86±0.27. Knowledge of the elderly averaged 11.27±3.30 points out of 25. The question with the highest percentage of correct answers to knowledge about the elderly was 'physical strength tends to decrease with age', which was 93.1%. The attitude toward the elderly according to the general characteristics of the study subjects showed significant differences in gender (p=0.040), age (p=0.026), and life experience with grandparents (p=0.001). The elderly discrimination of the study subjects showed a negative correlation in both attitude and knowledge toward the elderly, and among the elderly discrimination, there was a high positive correlation with regard to emotional avoidance (r=.892, p<0.001). Conclusion: College students are the leading players in caring for the elderly and are directly affected by aging social problems. Therefore, it is considered necessary to apply various programs in the state, society, and educational institutions to avoid negative prejudices that lead to positive thinking and discrimination against the elderly.

Comparative Study of the Surface Roughness of Working Models Fabricated by Dental CAD/CAM Scannable Stone and Type IV Gypsum Products (치과용 캐드캠 스캔전용 석고와 Type IV 석고로 제작된 작업모형의 표면조도 비교 연구)

  • Kim, Sa-Hak;Kim, Jae-Hong
    • Journal of dental hygiene science
    • /
    • v.14 no.4
    • /
    • pp.455-460
    • /
    • 2014
  • This study compared the surface roughness and surface characteristics between a type IV stone and scannable stone. Materials used were a type IV stone, two different kind of scannable stone. Ten specimens per experimental group were prepared according to manufacturer's direction. Surface roughness of specimen was measured using profilometer. The measurement was based on the standard of Japanese Industrial Standards 1994. The mean and standard deviations of each reference point were analyzed using one-way ANOVA and Scheff$\acute{e}$ post hoc test. The program used to handle statistical analysis was SPSS 20.0 and the significance level was set at 0.05. The difference of surface roughness was statistically significant in order of Scannable Stone $10.07{\pm}0.02{\mu}m$, Scannable Stone $20.08{\pm}0.03{\mu}m$, Type IV $0.10{\pm}0.04{\mu}m$. These results will have to be confirmed in further clinical application researches.

The Microbial Contamination and Effective Control Method of Dental Unit Water System (치과용 유니트 수계의 미생물 오염 및 효과적인 관리 방법)

  • Yoon, Hye Young;Lee, Si Young
    • Journal of dental hygiene science
    • /
    • v.15 no.4
    • /
    • pp.383-392
    • /
    • 2015
  • Dental chair unit (DCU) is the most essential equipment for the dental treatment in dentistry. DCU output water is used for various applications during dental treatment. DCU output water must be clean at the same level as drinking water since patients and dental staff are regularly exposed to water and aerosols generated from the DCU. Many studies demonstrated that DCU output water is frequently contaminated with microorganisms including opportunistic pathogen such as Legionella and Pseudomonas species. Thus, DCU output water may be a potential source of infection. In order to reduce microbial contamination levels in DCU output water, periodic management and continuous disinfection are necessary. Currently, there are a variety of disinfection methods for managing DCU output water and its efficacy is also diverse. We reviewed the level of microbial contamination, clinical implications of contaminated DCU output water and the various DCU disinfection methods.

Evaluation of Dimensional Stability of Digital Dental Model Fabricated by Impression Scanning Method (인상 스캐닝 방법에 의해 제작된 디지털 치과 모형의 체적 안정성 평가)

  • Kim, Jae-Hong;Kim, Ki-Baek
    • Journal of dental hygiene science
    • /
    • v.14 no.1
    • /
    • pp.15-21
    • /
    • 2014
  • The purpose of this study in vitro investigation was to evaluate the dimensional stability of dental digital models made by impression scanning method. Twenty working models were produced. Twenty impressions were made from study models. The dimensional stability of models of two groups (stone and digital models) was examined using six landmark distances. Stone models were measured through digital vernier calipers. Digital models were measured by the computer program. Statistical analyses were performed with Wilcoxon rank sum test (${\alpha}=0.05$). The mean of six landmark distances were significantly larger in the stone models than in the digital models (p<0.05) but digital models showed clinically acceptable accuracy.