• Title/Summary/Keyword: 인체 물성

Search Result 93, Processing Time 0.028 seconds

Functional Modification of Sanitary Nonwoven Fabrics by Chitosan Treatment (Part II) -Focused on Changes in Physical Properties- (키토산 처리에 의한 위생용 부직포의 기능성 개질화 (제2보) -물성 변화를 중심으로-)

  • Bae, Hyun-Sook;Kang, In-Sook;Park, Hye-Won;Ryou, Eun-Jeong;Kwon, Jay-Cheol
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.31 no.12
    • /
    • pp.1662-1671
    • /
    • 2007
  • The change in physical properties of polypropylene nonwoven fabrics used as top sheet for disposable sanitary goods was carried out using chitosan that is a type of natural polymer and has excellent human affinity by varying the molecular weight and concentration of chitosan. Low molecular weight(LMW) chitosan treated fabrics were found to be evenly coated on fabrics and had better dyeability by apparent dye uptake and its deodorization rate increased over the time. On the other hand, high molecular weight(HMW) chitosan treated fabrics showed higher add-on ratio and its dynamic water absorption rate and represented an increase in water transport rate. With chitosan treatment, its air permeability was improved. Regardless of the type of bacteria and chitosan concentration, its antibacterial activity was excellent in the case of the HMW chitosan treatment. In this regard, chitosan treatments by using a relatively high molecular weight was found as an effective way in the functional improvement of moisture properties and antibacterial activity including their most important performance in sanitary nonwoven fabrics.

Development and Prospect of Emulsion Technology in Cosmetics (화장품에서 유화기술의 발전 및 전망)

  • Kyong, Kee-Yeol;Lee, Cheon-Koo
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.32 no.4 s.59
    • /
    • pp.209-217
    • /
    • 2006
  • Emulsion is a dispersion system among liquids which are not miscible together. There are numerous cosmetic raw materials which have different physicochemical properties. Therefore, emulsion technology is very useful in cosmetics. With the development of emulsifier, several emulsification technologies have been developed. Since HLB method by Griffin in 1950's, PIT method, gel method, and D-phase methods, etc, have been developed. Recently, the application of natural emulsifier and polymeric emulsifier increases in cosmetics in order to achieve enhanced safety and biocompatibility. Besides nano-emulsion, multiple-emulsion, liquid crystal emulsion, and Pickering emulsion have been developed and applied as means of differentiating appearance and texture of products and achieving enhanced delivery of active ingredients. Meanwhile, the application studies of nano-dispersed structural system such as liposome or cubosome are on progress. Liposome is a bi- or multi-lamella layer dispersion system composed of amhiphilic molecules - phospholipids which are main components of plasma membrane. Cubosome also is a nano-sized dispersion system composed of a specific molecule like glyceryl monoloeate derived from natural products. And it has a cubic bicontinuous structure in water due to its unique molecular structure. Incorporating compounds (active materials) into such nano-particles can increase biocompatibility and delivery efficiency of target compounds. Manufacturing process and application of cosmetic emulsions and nano-particles are briefly introduced in this paper.

Surface properties on ion beam irradiated polycarbonate (이온주입에 의한 폴리카보네이트의 표면특성 조사)

  • Lee, Jae-Hyung;Yang, Dae-Jeong;Kil, Jae-Kyun;Kim, Bo-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.31-35
    • /
    • 2003
  • 폴리카보네이트는 내열성과 투명성이 우수한데 비해 내후성이 좋지 않아 황변 및 물성이 저하되고, 내찰상성이 약하여 긁히기 쉬운데다 이물질에 의해 오염되기 쉬워 투명성이 저하되는 문제점이 있다. 이러한 단점을 극복하고, 사용하는 용도에 따라 요구되는 다양한 기능성을 부여하기 위하여 폴리카보네이트 표면에 기능성층을 형성시킴으로써 그 목적을 달성하고자 한다. 본 논문에서는 이온 주입기술을 이용하여, 폴리카보네이트 표면의 전기전도도 특성을 향상시키고, 피부암 및 백내장 등을 유발하는 유해한 자외선 (UV-A, UV-B)을 차단하려 한다. 표면전기전도도의 향상은 이물질로부터 오염되는 정도를 낮추며, 정전기를 방지할 수 있다. PC(Polycarbonate) 표면에 $N^+,\;Ar^+,\;Kr^+,\;Xe^+$ 이온을 에너지 20keV에서 50keV을 사용하여, 주입량 $5{\times}10^{15}\;{\sim}\7{\times}10^{16}\cm^2$ 로 조사하였다. 이온 주입된 PC의 표면을 두 접점 방법의 표면 저항 측정으로 표면전기전도도 특성을 알아보았고, 자외선차단 특성은 UV-Vis 로 분석하였다. 이들 전기적 광학적 특성간의 상관관계를 관찰하고, 이러한 특성을 나타내는 화학적 기능그룹들의 변화를 보기 위해 FTIR 분석법으로 관찰하였다. 이온조사량의 증가에 따라 표면저항은 $10^7{\Omega}/sq$까지 감소하여 표면전기특성을 증가시키며, 자외선 차단 특성은 UV-A를 95%까지 차단하여 인체에 유해한 자외선 차단에 유용함을 확인하였다. 이러한 특성은 PC 표면에 카본 네트워크 형성과 $\pi$전자들의 운동량을 증가시키는 구조로 고분자 사슬들의 결합구조 변형에 의한 것으로 생각된다.블을 가지고 파서를 설계하였다. 파서의 출력으로 AST가 생성되면 번역기는 AST를 탐색하면서 의미적으로 동등한 MSIL 코드를 생성하도록 시스템을 컴파일러 기법을 이용하여 모듈별로 구성하였다.적용하였다.n rate compared with conventional face recognition algorithms. 아니라 실내에서도 발생하고 있었다. 정량한 8개 화합물 각각과 총 휘발성 유기화합물의 스피어만 상관계수는 벤젠을 제외하고는 모두 유의하였다. 이중 톨루엔과 크실렌은 총 휘발성 유기화합물과 좋은 상관성 (톨루엔 0.76, 크실렌, 0.87)을 나타내었다. 이 연구는 톨루엔과 크실렌이 총 휘발성 유기화합물의 좋은 지표를 사용될 있고, 톨루엔, 에틸벤젠, 크실렌 등 많은 휘발성 유기화합물의 발생원은 실외뿐 아니라 실내에도 있음을 나타내고 있다.>10)의 $[^{18}F]F_2$를 얻었다. 결론: $^{18}O(p,n)^{18}F$ 핵반응을 이용하여 친전자성 방사성동위원소 $[^{18}F]F_2$를 생산하였다. 표적 챔버는 알루미늄으로 제작하였으며 본 연구에서 연구된 $[^{18}F]F_2$가스는 친핵성 치환반응으로 방사성동위원소를 도입하기 어려운 다양한 방사성의 약품개발에 유용하게 이용될 수 있을 것이다.었으나 움직임 보정 후 영상을 이용하여 비교한 경우, 결합능 변화가 선조체 영역에서 국한되어 나타나며 그 유의성이 움직임 보정 전에 비하여 낮음을 알 수 있었다. 결론: 뇌활성화 과제 수행시에 동반되는 피험자의 머리 움직임에 의하여 도파민 유리가 과대평가되었으며 이는 이 연구에서 제안한 영상정합을 이용한 움직임 보정기법에 의해서 개선되었다. 답이 없는 문제, 문제 만들기, 일반화가 가능한 문제 등으

  • PDF

Flexible 의료 영상 센서로 적용하기 위한 Flexible ITO substrate의 가스분압 특성 및 Bending의 전기적 특성 연구

  • Gang, Jin-Ho;Hong, Ju-Yeon;Kim, Dae-Guk;O, Gyeong-Min;Heo, Seung-Uk;Nam, Sang-Hui
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.185-185
    • /
    • 2013
  • 최근 의료 영상 센서는 급속도로 발전을 이룩하여 미세 병변의 위치와 그 크기를 진단하는 데에 많은 이용이 되고 있다. 하지만 기존 flat panel형태의 의료영상 센서는 인체의 굴곡으로 인한 영상 왜곡으로 발전의 한계에 이르고 있는 실정이다. 이 영상 왜곡으로 인한 오진은 환자에게 불필요한 피폭, 수술적 요법, 약물치료 등 환자에게 치명적인 의료사고를 일으킬 수 있다. 이러한 한계를 극복하기 위하여 flexible substrate을 이용한 투명전극들이 의료영상 센서로서의 적용을 연구 되어 졌다. IZO, ITO, FTO 등의 투명전극들 중 Indium Tin Oxide(ITO)는 다른 전극에 비해 높은 투명도와 낮은 저항으로 인하여 다양한 부분에서 널리 이용 되고 있다. 그러나 ITO를 flexible substrate로 적용 시 불충분한 resistivity와 기계적 강도를 지니고 있으며, 유연성을 위해 전극 재료의 두께를 감소시키면 전도성의 문제를 일으키는 단점이 있는 것으로 알려져 있다. 이러한 문제점을 보완 및 해결하기 위하여 본 연구에서는 sputtering magnetron system를 이용하여 polyethylene terephthalate(PET) substrate 위에 ITO을 증착함으로써 전기적 특성을 알아보았다. PET 필름의 크기를 55 절단하였고 증착 온도는 고온에서 수축하는 PET 필름의 물성을 고려하여 $23^{\circ}C$로 설정 하였다. 가스의 분압 비를 Ar는 50ccm으로 고정하고 O2의 비율을 각각 0, 0.2, 0.4, 0.8, 1ccm으로 나눈 후, 비율에 따라 각각 30, 60, 90sec간 sputtering 증착을 하였다. 또한 각각 30, 60, 90sec간 sputtering 증착하여 O2 유량과 sputtering 증착 시간의 변화에 따른 ITO의 전도특성과 유연성에 대한 전도특성을 측정하였다. 유연성을 측정하기 위해선 bending 각도를 각각 $0^{\circ}$ $30^{\circ}$, $45^{\circ}$, $60^{\circ}$로 구부린 후, Two-point probe를 이용하여 변화된 저항을 통해 ITO의 전기적 성질의 변화를 측정 하였다. 측정결과 flexible ITO substrate의 전도특성은 sputtering 증착시간이 증가할수록 저항 값이 낮아지는 것을 확인하였지만, O2 유량이 증가 시 저항이 낮아지다가 다시 증가하는 결과를 알 수 있었다. 본 연구에서는 Ar:O2의 50:0.8의 조건에서 90sec동안 sputtering 증착한 ITO가 131 ${\Omega}/cm^2$의 저항 값이 측정 되었고 다른 조건에서는 164 ${\Omega}/cm^2$에서 4.7 $k{\Omega}/cm^2$까지 저항변화를 가져 Ar:O2의 50:0.8의 조건이 최적화에 좋은 조건이라 판단하였다. 또한 50:0.8의 조건의 ITO의 경우 bending test시에서도 131 ${\Omega}/cm^2$에서 316 ${\Omega}/cm^2$ 정도의 안정적인 저항변화를 가지는 반면 다른 조건에서는 128 ${\Omega}/cm^2$에서 6.63 $k{\Omega}/cm^2$까지의 변화를 나타나 기계적 형상변화에도 분압비가 영향을 주는 것을 확인 할 수 가 있었다. bending 각도에 따른 저항의 변화를 측정하였을 시, 각도 변화에 따라 중심부의 저항 값이 $60^{\circ}$에서 가장 높은 변화가 나타나 전기저항이 높아진 원인을 찾기 위해 Scanning Electron Microscope (SEM)촬영을 한 결과 저항값이 높아짐에 따라 ITO의 압축응력이 작용하는 부근에 Crack이 발생함을 알 수 있었다. 이러한 결과로 flexible ITO substrate의 Crack발생률을 최소화 시키고 bending시 전도성을 유지하기 위해서는 가스의 유량 최적화가 flexible substrate의 기계적형상변화에 대한 ITO의 내구성을 향상시킬 수 있는 해답이 될 것으로 사료된다.

  • PDF

Manufacture and Characterization of Silkworm Gland Hydrolysate (누에 실샘 가수분해물의 제조 및 특성 규명)

  • Hwang, Jung Wook;Lee, Heui Sam;Kim, Hojin;Kim, Kyu-Oh;Choi, Yong-Soo
    • Journal of Sericultural and Entomological Science
    • /
    • v.50 no.2
    • /
    • pp.76-81
    • /
    • 2012
  • Silk protein has been explored to be used for biomedical applications for several decades. However, it has not been used in this field cause to their irreversible crystallization after dissolving in water. The existing methods of silk protein hydrolysis using silkworm cocoon were used with harmful solvents and through a very complicated process. Therefore, we have developed novel methods for the production of water-soluble hydrolysate using silkworm gland. We manufactured two types of silkworm gland-derived hydrolysate (water-soluble SGH, SSGH; total SGH, TSGH) and compared the characteristics with commercial cocoon-derived sericin hydrolysate (CSH). The molecular weight of SGH ranged from 7 to 50 kDa (SSGH) and 5 to 15 kDa (TSGH) within glycine, alanine, and aspartic acid as a main amino acid composition. In contrast, CSH ranged from 15 to 50 kDa within serine and aspartic acid. The results of FTIR implied that SGH was more soluble form than CSH, as shown by the decrease in the ${\beta}$-sheet structure at $1630cm^{-1}$ on amide I peak. In comparison with 10% fetal bovine serum, 0.1% (1 mg/ml) SSGH had equivalent effect on the proliferation of human dermal fibroblasts and mesenchymal stem cells. All results of the SSGH made by novel manufacturing process indicate the SSGH is more preferable as a culture medium supplement than cocoon-derived sericin.

Effect of Addition of β-TCP on Bioactivity and Mechanical Properties of Biodegradable PLA/β-TCP Composites (β-TCP 첨가량에 따른 생분해성 PLA/β-TCP 복합체의 생체활성과 기계적 특성 평가)

  • Moon, Hee-Jung;Kim, Seol-Ak;Kim, Dong-Ae
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.3
    • /
    • pp.609-615
    • /
    • 2021
  • The aim of the present study was to investigate the mechanical properties of melt-injected poly lactic acid (PLA) composites with β-tricalcium phosphate (β-TCP). The PLA mixed with calcined PLA/β-TCP powder to be contents of 0, 10, 30, 50 wt%, respectively, was dissolved in chloroform solvent under stirring for 24 h. Then the liquid mixtures were dropped into ethanol to extract solvent. After drying, the well-dispersed PLA/β-TCP composites were granulated and melt-injected to prepare specimens for various mechanical testing. PLA/β-TCP induced the precipitation of an apatite bone-mineral phase on the surface after immersion in a human simulated body fluid (SBF) for 90 days, showing in bioactivity. Mean various mechanical properties PLA/β-TCP composite were increased up to 10-30 wt% with significantly in part and composite were decreased 50 wt% of showing in mechanical properties. In conclusion, Over 30 wt% addition of β-TCP to PLA may be not advisable to improve the mechanical properties of melt-injected polymeric composites. Results indicated that β-TCP can be used considered as potential reinforcing agent for increasing mechanical properties for PLA. Therefore, it was suggest that the additional effects of β-TCP and research on a wide range of substances.

Optimization of In Vivo Stickiness Evaluation for Cosmetic Creams Using Texture Analyzer (Texture Analyzer (TA)를 이용한 화장품 크림의 In Vivo 끈적임 평가법의 최적화)

  • Ryoo, Joo-Yeon;Bae, Jung-Eun;Kang, Nae-Gyu
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.46 no.4
    • /
    • pp.371-382
    • /
    • 2020
  • There have been continuous attempts to quantify sensory attributes of cosmetic products by measuring relevant physical properties. The most representative method to evaluate stickiness is to measure axial force using texture analyzer. Stickiness is known to correlate with AUC which abbreviates area under curve in the obtained axial force curve as a function of time. Recently, Normandie University research group developed in vivo stickiness evaluation method considering the characteristics of skin along with established evaluation method[8]. Based on the study, we tried to optimize in vivo stickiness evaluation method especially for cosmetic creams. The experiment was carried out on 5 different facial creams products by changing the amount and the times of rolling of creams, and the shape and material of probes. Based on the results of the sensory evaluation, the most consistent conditions were established as the optimal evaluation method. As a result, applying 70 μL of cream and rubbing 10 times for 7 s inside the 3.4 cm circle were judged to be suitable. As for the probes, spherical metallic probe was more proper due to its reproducibility. We conducted the settled method on 10 subjects to check its validity. Although the absolute values of AUC differed depending on the individuals, the AUC values were all ranked the same. Finally, for the standardization of stickiness of AUC, polyvinylpyrrolidone (PVP) was set as a reference material and we measured AUC of its aqueous solution by changing concentration. Then, the degree of stickiness recognition for 5 different creams was surveyed to check the correlation between AUC and stickiness.

A Study on Inhibition of Bacterial Membrane Formation in Biofilm formed by Acne Bacteria in Valine through Property Analysis (물성 분석을 통한 Valine 의 여드름균 바이오필름 내부 세균막 형성 억제 연구)

  • Song, Sang-Hun;Hwang, Byung Woo;Son, Seongkil;Kang, Nae-Gyu
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.47 no.2
    • /
    • pp.163-170
    • /
    • 2021
  • This study was conducted to create a technology to remove acne bacteria with human-friendly materials. First, the Cutibacterium acnes (C. acnes) were adsorbed to the mica disc to grow, and then the biofilm was checked through an atomic microscope to see if the biofilm had grown. Based on the topographic image, the shape changed round, the size was 17% longer on average, and the phase value of the resonance frequency separating materials was observed as a single value, the biofilm grown by covering the extracellular polymeric substrate (EPS). As a result of processing 50 mM of amino acids in the matured biofilm, the concentration of C. acnes decreased when valine, serine, arginine and leucine were treated. Scanning with nanoindentation and AFM contact modes confirmed that the hardness of biofilms treated with Valine (Val) increased. This indicates that an AFM tip measured cell which may have more solidity than that of EPS. The experiment of fluorescent tagged to EPS displays an existence of EPS at the condition of 10 mM Val, but an inhibition of growth of EPS at the 50 mM Val. Number of C. acnes was also reduced above 10 mM of Val. Weak adhesion of biofilm generated from an inhibition of EPS formation seems to induce decrease of C. acnes. Accordingly, we elucidated that Val has an efficiency which eliminates C. acnes by approach of an inhibition of EPS.

A Study on the Applicability of Acrylic Water Leak Repair Materials used to Repair Cracks in Conduits and Underground Structures (관거 및 지하구조물 균열 보수에 사용되는 아크릴 누수 보수재의 적용성에 대한 연구)

  • Eunmi Lee;Kyungik Gil
    • Journal of Wetlands Research
    • /
    • v.26 no.2
    • /
    • pp.139-146
    • /
    • 2024
  • Various injection materials, such as asphalt-based injection materials, urethane-based injection materials, cement- based injection materials, and acrylic-based injection materials, are used for the repair of aged conduits and underground structures with cracks. In this study, research was conducted on an environmentally friendly acrylic- based leak repair material that exhibits good curing properties even in humid conditions and stability in temperature fluctuations. To compare the performance of the improved acrylic leak repair material with the existing acrylate injection material, experiments were conducted using KS standard methods, including underwater length change rate tests, underwater leakage resistance tests, and chemical performance tests. The comparative experiments revealed that the improved acrylic leak repair material showed no changes in shrinkage due to humidity, temperature variations, or chemical reactions compared to the existing acrylate injection material. In the underwater resistance test, the improved acrylic leak repair material did not show any leakage. Additionally, to assess the environmental impact of the improved acrylic leak repair material, acute fish toxicity tests and acute oral toxicity tests were conducted, and the results showed no mortality and no specific concerns with the test specimens. The experimental results led to the conclusion that the improved acrylic leak repair material is considered to be superior in performance, environmentally safe, and harmless to the human body. Based on various experimental results, it is inferred that the improved acrylic leak repair material is suitable for use as a repair material for cracks in manholes and underground structures compared to the existing acrylate repair material. This study aims to propose valuable data for future technological development by evaluating the applicability of acrylic leak repair materials.

A STUDY ON THE SIZE OF THE PERMANENT TEETH (영구치의 치아크기에 관한 연구)

  • Baik, Byeong-Ju;Park, Jeong-Yeol;Kim, Jae-Gon;Lee, Doo-Cheol
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.3
    • /
    • pp.502-509
    • /
    • 2003
  • After 800 students of Chonbuk National University was examined, 86 people (male : 43, female : 43, mean age : 22.2 years old) was selected as a group of normal occlusion. From their gypsum cast, this conclusion was obtained. 1. Intra-observer measurement errors in buccolingual diameter, maxillary lateral incisors have somewhat bigger errors. In mesiodistal diameter, maxillary first molars and maxillary second molar have bigger numerical value. Mean errors of measurement are 0.051mm at buccolingual diameter of crown and 0.083mm at mesiodistal diameter. 2. Fluctuating asymmetry is 0.030 average in buccolingual diameter, and 0.037 average in mesiodistal diameter. Statistically there are no big differences. 3. Male has longer buccolingual diameter than female in every permanent teeth. Teeth which have statistical difference in buccolingual diameter are maxillary lateral incisor, maxillary canine, maxillary second molar, mandibular central incisor, mandibular canine, mandibular second premolar, and mandibular first molar. In mesiodistal diameter maxillary central incisor, maxillary canine, and mandibular first molar have statistically difference. 4. Tooth which has the biggest difference depending on gender is maxillary lateral incisor in buccolingual diameter and mandibular canine in mesiodistal diameter. 5. Both sexes have similar crown index. Male has bigger value of crown module measurement and crown area measurement in every tooth. Crown area considered as size of tooth from occlusal surface was bigger in male than in female statistically except some teeth, maxillary first premolar, mandibular lateral incisor, first premolar and second premolar.

  • PDF