A Study on Sunshine Environment with Different Distance between Buildings (인동간격에 따른 일조환경에 대한 연구)

  • 최용석;최지혜;김용식
    • Journal of the Korean housing association
    • /
    • v.15 no.2
    • /
    • pp.55-62
    • /
    • 2004
  • Apartment design in residential Area is restricted by building distance limit code. Building distance limit decreases gradually to the 0.8H(height), and residential area has 250% site area ratio by building code, so site using has become efficient. In this study, examine the relationship between present building distance limit and right of daylighting environment by computer simulation. As well, high-rise residential officetel and multipurpose residential building becomes increase in commercial non-residential area. In the domestic, residential type multipurpose building made at the business area or central business area has 400∼800% site area ratio by building code. However, at a dweller's point of view, there are much lacks of environmental consideration to provide suitable daylighting environment. And, POE: Post Occupancy Evaluation is not completed yet. In this study, however, progress architectural environment prediction, basis by right of daylighting, and examine the possibility of daylighting by architectural distance limit code in residental area and by high-rise, high-density residential building in non-residental downtown area.

An Analysis of Complex for a Parking Lot Expansion (주차장 확대를 위한 공동주택 단지특성 분석)

  • Ha, Na;Song, Nak-Hyun;Yoon, Ho-Bin;Lee, Chan-Sik
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2007.11a
    • /
    • pp.1039-1042
    • /
    • 2007
  • The number of vehicle has been increased due to growth of economy. Consequently, the needs for parking area has been increasing. there is a serious problem in aged-apartments. It result from observing a parking lot law at that times. That is the reason why residents demand parking lot expansion. Parking lot addition is being studied on a lots different standpoint to solve the present parking lot condition. Parking lot expansion is limited by housing complex characteristics. This study analyzed the housing complex characteristics of aged-apartment. It is analyzed that the number of house holders, distance between buildings, and level of site for finding housing complex characteristics. The result are as follows. the complex lower than 300 households is about 35% in the Number of households. The buildings which has a moving distance from 41m to 50 is nearly 23%. Them the 멕스둣 house located on the flat is 82%. This study will become a reference data for the parking lot expansion.

  • PDF

Analysis on the Effects of Sunshine Environment by Overpass Structure in Urban Areas (도시부 고가구조물에 의한 일조환경 영향분석)

  • Kum, Ki-Jung;Kim, Jong-Bo;Choi, Yong-Gil;Kim, Young-Jun
    • International Journal of Highway Engineering
    • /
    • v.11 no.4
    • /
    • pp.49-58
    • /
    • 2009
  • Current sunshine regulations of our country, focused on common houses and general construction, are failing to reflect adequately the characteristics of roads and elevated structures. Besides, researches are chiefly being conducted on a pitch between common houses and its diverse effects, neglecting clearance between a road or elevated structure and a residential area, environmental elements brought on by structures, such as sunshine difficulty, and their resultant factors Therefore, this study, focused on the sunshine environment of elevated structures adjacent to a residential district, as part of all roads and elevated structures, looked over currently used clearance adequacy level and analyzed the characteristics of structures in relation to an angle of direction. Then, clearance ratio by heights was calculated through a pitch by characteristics of a structure. With a view to minimize the sunshine difficulty that might occur in the future construction, it aims to propose the basic data needed for calculating the minimum clearance, while emphasizing the necessity for institutional alignment on structures.

  • PDF

A Study on the Planning of Multi-Family Residential Buildings considering Daylight, View and Natural Ventilation (일조와 조망, 자연환기성능을 고려한 공동주택 배치계획에 관한 연구)

  • Choi, Doo-Sung;Cho, Kyun-Hyong
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.3
    • /
    • pp.55-64
    • /
    • 2010
  • The study has conducted a research on the main shape of domestic multi-family residential buildings. The four arrangements were selected after the research and each of them was analyzed for daylight, view and natural ventilation according to the different pitch of buildings. Based on the results from the analysis, the optimum pitch of buildings for each of the arrangements are as follows. With looking at the outcomes from the analysis on changes in residential environment by the pitch of building buildings in the four arrangements, it was figured out that it would be the best if the distance is more than 1.0H for Case_1. For Case_2, it should be more than 0.9H and for Case_3, it has to be 1.0H or more. Last but not least, it seems to be superb if the distance is more than 0.9H for Case_4.

A Study on the evaluation of the Residential Environment Efficiency by Arrangement of Multi-Family Residential Buildings - focused on the evaluation of daylight and view environment - (공동주택 주동 배치유형에 따른 주거환경성능 평가에 관한 연구 - 일조 및 조망환경성능 평가를 중심으로 -)

  • Choi, Doo Sung;Do, Jin Seok
    • KIEAE Journal
    • /
    • v.9 no.6
    • /
    • pp.57-64
    • /
    • 2009
  • To make a prediction for a change of residential environment caused by the building code in Seoul which includes loosening the distance between multi-residential buildings, proposals of the four main building arrangements by analyzing examples were selected and then, amount of daylight and view efficiency were analyzed and presented through computer simulation for the proposals. In the result of the analysis, there was a difference among the arrangements but, when the distance between buildings was applied 0.8H as the least, residential environment like daylight and view efficiency per unit significantly decreased in quality. Particularly, for the middle stories(6-15) and the high stories(16~24), when the distance between buildings decreased from the current measurement, 1.0H, to 0.8H, the analysis indicated that 28% of daylight and 7% of view efficiency were reduced. In the building arrangements, an order of the best residential environment was followed in this sequence; balanced arrangement of flat type as the best, combined arrangement between L-shape and tower types, balanced arrangement of tower type, combined arrangement between flat and Y-shape types, grid arrangement of flat type, and combined arrangement between Y-shape and tower types as the least.

Characteristic of Wind Flow around Building Structures for Wind Resource Assessment (풍자원 평가를 위한 건축물 주변의 유동특성)

  • Cho, Kang-Pyo;Jeong, Seung-Hwan;Shin, Seung-Hwa
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.3
    • /
    • pp.50-58
    • /
    • 2011
  • To utilize wind resources effectively around buildings in urban area, the magnitudes of wind velocity and turbulence intensity are important, which means the need of the information about the relationship between the magnitude of wind velocity and that of fluctuating wind velocity. In the paper, wind-tunnel experiments were performed to provide the information about Characteristic of Wind flow around buildings with the spanwise distance and the side ratio of buildings as variables. For a single building with the side ratios of one and two, the average velocity ratio was 1.4 and the velocity standard deviation ratio ranged from 1.4 to 2.6 at the height of 0.02m at the corner of the windward side, in which flow separation occurred. For twin buildings with the side ratios of one and two, the velocity ratio ranged from 2 to 2.5 as the spanwise distance varied at the height of 0.02m, and the velocity standard deviation ratio varied near 1.25. For twin buildings with the side ratios of one and two, the maximum velocity ratio was 1.75 at the height of 0.6m, and the maximum velocity standard deviation ratio was 2.1. It was also found from the results of CFD analysis and wind-tunnel experiments that for twin buildings with the side ratios of one and two, the difference between the velocity ratio of CFD analysis and that of wind-tunnel experiments at streamwise distances was near 0.75.

An Experimental Study on the Fire Spread Risk Asessment according to the Eaves Conditions and Building Arrangement (건물의 인동거리 및 처마조건에 따른 화재확대 위험성 평가 실험)

  • Shin, Yi-Chul;Koo, In-Hyuk;Hayashi, Yoshihiko;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.04a
    • /
    • pp.536-541
    • /
    • 2010
  • 최근 도시화, 산업화 등으로 인하여 인구 및 도시시설이 밀집되어 자연적 재해 및 인위적 재난에 취약한 구조를 가지고 있으며, 오래된 시가지와 고지대주거지를 중심으로 재난에 무방비한 장소들이 존재한다. 이는 급속한 도시화 과정에서 비롯된 것으로 도시기반시설이 정비되지 않은 상황에서 무질서한 도시팽창이 이루어낸 결과라고 할 수 있다. 따라서 우리나라의 도시화재 발생 위험성을 평가하기 위한 도시화재의 물리적 연소성상 예측모델을 구축하기 위해 건물간격에 따른 유풍시에 개구분출화염의 성상에 대한 실험을 실시하였다.