• Title/Summary/Keyword: 인간의 동적하중

Search Result 4, Processing Time 0.019 seconds

Characteristic of Human Dynamic load Acting on the Lightweight Wall (경량벽체에 작용하는 인간의 동적하중 특성)

  • Roh, Yong-Woon;Choi, Soo-Kyung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.188-189
    • /
    • 2013
  • The purpose of this research is to comprehend experimentally the characteristic of human dynamic load and provide the result as basic data to suggest a valid impact-resistance evaluation method. Human motions exerting dynamic load are classified to 3 types. Selecting 3 ranks of motion strength, 3 ranks of load plane stiffness (A:20kN/cm, B:4.7kN/cm, C:2.2kN/cm), and 30 male grownup inspectors in their twenties, load was measured when they applied force on load plane. Result of this research is as follows: (1) Human dynamic load has different nature from object collision in the highest load ratio depending on the load plane stiffness and action time (2) The highest load ratio for each motion was 10.06 for kicking, 4.44 for hitting with shoulder, and 5.58 for fist blow.

  • PDF

Characteristics of the Human Strength Acting on the Lightweight Wall of Buildings (인간이 경량벽체에 가하는 수평하중의 크기에 관한 연구)

  • Choi, Soo-Kyung;Roh, Yong-Woon;Kim, Sang-Heon;Lee, Young-Do
    • Journal of the Korea Institute of Building Construction
    • /
    • v.15 no.5
    • /
    • pp.473-481
    • /
    • 2015
  • The purpose of this research is to comprehend experimentally the characteristics of human strength for using as the basic data of impact resistance test method of lightweight wall. Human motions exerting static load are classified to 4 types. Pushes with two hands or shoulder are defined as the instantaneously forcing motions with hands or shoulder put on the force plate. Leanings back or one-hand against the wall are defined as motions of taking a rest in their respective comfortable posture. Human motions exerting dynamic load are classified to 3 types. Selecting 3 levels of motion strength (weak, middle, strong), 3 levels of force plate stiffness (A: 20kN/cm, B: 4.7kN/cm, C: 2.2kN/cm), and 30 male subjects, load was measured when they applied strength to the force plate. Results of this research are as follows: (1) The maximum load ratio (Pmax/W) of static load for each motion was 1.17-1.25 in two hands pushing, 0.95-0.99 in shoulder pushing, 0.16-0.18 in back leaning, and 0.12-0.15 in one hand leaning. (2) Human dynamic load and object collision were different in the load characteristics. (3) The maximum load ratio of dynamic load for each motion was 10.07 in heel kick, 4.46 in shoulder hitting, and 5.58 in fist blow.

Microleakage of Endodontic Temporary Restorative Materials under Dynamic Loading (동적하중 하에서 근관치료용 임시충전재의 미세누출의 평가)

  • Jung, Dong-Ho;Noh, Young-Sin;Lee, Hae-Doo;Chang, Hoon-Sang;Ryu, Hyun-Wook;Min, Kyung-San
    • Proceedings of the KACD Conference
    • /
    • 2008.05a
    • /
    • pp.198-203
    • /
    • 2008
  • The purpose of this study was to compare the sealing abilities of four endodontic temporary restorative materials using a methylene blue dye penetration test under dynamic loading. Standardized access cavities were prepared in forty-four intact human permanent molar teeth, and the cavities were restored with Caviton, MD-Temp, IRM, or ZOE. After thermocycling, an intermittent load of 98 N at 1 Hz was applied for 1,000 cycles to the long axis of the functional cusp of each of the teeth, which were immersed in a 1% methylene blue solution. The teeth were split in half, and the linear depth of dye penetration was evaluated according to the criteria. The results were analyzed using one-way ANOVA (p = 0.05) and Duncan's multiple range test. The results demonstrated that Caviton and MD-Temp showed significantly lower microleakage than IRM and ZOE. It was concluded that Caviton and MD-Temp exhibited better sealing ability than IRM and ZOE under dynamic loading.

  • PDF

Microleakage of Endodontic Temporary Restorative Materials under Dynamic Loading (동적하중 하에서 근관치료용 임시충전재의 미세누출의 평가)

  • Jung, Dong-Ho;Noh, Young-Sin;Lee, Hae-Doo;Chang, Hoon-Sang;Ryu, Hyun-Wook;Min, Kyung-San
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.3
    • /
    • pp.198-203
    • /
    • 2008
  • The purpose of this study was to compare the sealing abilities of four endodontic temporary restorative materials using a methylene blue dye penetration test under dynamic loading. Standardized access cavities were prepared in forty-four intact human permanent molar teeth, and the cavities were restored with Caviton, MD-Temp, IRM, or ZOE. After thermocycling, an intermittent load of 98 N at 1 Hz was applied for 1,000 cycles to the long axis of the functional cusp of each of the teeth, which were immersed in a 1% methylene blue solution. The teeth were split in half, and the linear depth of dye penetration was evaluated according to the criteria. The results were analyzed using one-way ANOVA (p = 0.05) and Duncan's multiple range test. The results demonstrated that Caviton and MD-Temp showed significantly lower microleakage than IRM and ZOE. It was concluded that Caviton and MD-Temp exhibited better sealing ability than IRM and ZOE under dynamic loading.