• Title/Summary/Keyword: 이형층

Search Result 131, Processing Time 0.024 seconds

Tunable bragg filter of $Si_3N_4-SiO_2$ waveguide using thermooptic effect (열광학 효과를 이용한 $Si_3N_4-SiO_2$ 도파로 가변 브래그필터)

  • 이형종;정환재
    • Korean Journal of Optics and Photonics
    • /
    • v.3 no.4
    • /
    • pp.244-251
    • /
    • 1992
  • Buried Bragg filters of single mode $Si_{3}N_{4}$ rib waveguide with a cover layer of $SiO_{2}$ and grating at the interface of $Si_{3}N_{4}$ and $SiO_{2}$ are designed and fabricated. Etching of the grating on $Si_{3}N_{4}$ waveguide core by buffered HF showed uniform etching with good control up to 1 nm. This buried type of Bragg filters are immune to contamination of the surface of device. The mode index and bandwidth of filters are determined by measurements of the transmission spectrum of Bragg filters and compared with that of calculation. Waveguide Bragg filters loaded with the micro-heater of Cr film and the cladding of silicone rubber are made to control the Brag wavelength of the filter. As a result the filter wavelength of the device moved by 0.41 nm for 10 mA current to the shorter side of wavelength proportional to the square of the current.

  • PDF

An improved crystal rotation method for simultaneous measurement of pretilt angle and thickness of a liquid crystal layer (액정셀의 선경사각과 액정층의 두께를 함께 재는 개선된 결정회전법)

  • Son, Gong-Sook;Park, Chan;Park, Hee-Gap;Kim, Jin-Seung;Rho, Bong-Gyu;Lee, Hyong-Jong;Kim, Jae-Ki
    • Korean Journal of Optics and Photonics
    • /
    • v.7 no.3
    • /
    • pp.213-218
    • /
    • 1996
  • An improved crystal rotation method with increased accuracy and range is proposed and experimentally verified for simultaneous measurement of molecular tilt angle and thickness of LC (liquid crystal) layer of an LC cell. The improvement is brought about by direct determination of difference between phases instead of intensities of two components of orthogonal linear polarization of the light passing through an LC cell filled with uniformly oriented molecules. By comparing the experimental data with theoretical result the thickness and pretilt angle are determined more precisely. Further improvement is brought about by use of a liquid gate filled with an index matching liquid in which the LC cell is immersed. Because of the index matching liquid reflection of light at the surfaces of an LC cell almost completely disappears and the range of angle of refraction in the LC layer increases significantly, which gives rise to increased signal to noise ration as well as decreased statistical error. With this improvement precise measurement for either very thin (<10 ${\mu}{\textrm}{m}$) and/or higher pretilt angle($\geq$10$^{\circ}$) LC cells become possible.

  • PDF

Tin Alloy Electroplating Solution Containing Perfluorinated Alkyl Surfactant for Solder Bump (과불소화알킬 계면활성제를 함유하는 솔더범프용 주석합금 전기도금액)

  • Go, Jeong-U;O, Jeong-Hun;Son, Jin-Ho;Park, Gyu-Bin;Lee, Hyeong-Geun;Kim, Gyeong-Tae;Park, Hyeon-Guk;Jeong, Heung-Su
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2014.11a
    • /
    • pp.136-137
    • /
    • 2014
  • 주석계 전기도금액에 포함된 불소계 계면활성제는 분산 유화 소포 효과를 발휘할 수 있으며, 도금 금속 결정을 미세하게 하여 범프의 그레인 크기와 모양 특성을 개선하며, 범프의 높이 차 (WID, WIW) 감소 및 범프 내 빈 공간과 금속간 층의 균열 생성 방지에 영향을 주었음을 알 수 있었다.

  • PDF

내진벽 강성이 면진시스템의 지진응답에 미치는 영향

  • Koo, Gyeong-Hoe;Lee, Jae-Han;Lee, Hyeong-Yeon;Kim, Jong-Beom;Yoo, Bong
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.05a
    • /
    • pp.989-994
    • /
    • 1995
  • 본 연구의 목적은 국내에서 개발중인 액체금속로의 면진설계를 위하여 면진층과 원자로용기 사이에 있는 내진벽의 강성이 면진시스템의 지진응답에 미치는 영향을 분석하는 것이다. 이를 위하여 내진벽강성을 고려한 모우드해석을 수행하여 내진벽의 강성변화에 따른 동특성해석을 수행하였으며 면진 및 비면진시스템의 경우에 대하여 지진해석을 수행하였다. 면진 및 비면진시스템에 대한 지진해석결과에서 비면진시스템의 경우에 내진벽강성은 지진응답에 영향을 주지만 면진시스템의 경우에는 그 영향이 매우 작은 것으로 나타났다.

  • PDF

Geotextiles Horizontal Drain between Earth Fills and Natural Soft Ground (토목섬유를 사용한 무처리 연약지반과 성토사이의 수평배수층)

  • Lee, Hyoung-Kyu;Kong, Kil-Yong;Kim, Hyun-Tae
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.44 no.4
    • /
    • pp.129-138
    • /
    • 2002
  • This paper presents a study on the discharge capacity of geotextiles as a horizontal drain layer placed between the layers of earth fill and natural soft ground. Required discharge capacity of geotextiles as drain layers estimated by consolidation analysis is proportional to the consolidation coefficient of the ground soils and the width of the earth fills. The field discharge capacity of the geotextiles are measured by the hydraulic transmissivity test. And the results show wide variation according to the material characteristics of geotextiles, water content of the soils, vertical pressure, and etc. For the short horizontal drain length, geotextile filter mat can be used for the horizontal drain layer. And f3r the long drain($25{\sim}55m$), it is used for the drain together with Bord Drain.

Experimental Study on Modal Parameter Estimation of Structures (구조물의 자유진동특성 추정을 위한 실험적 연구)

  • 윤정방;이형진
    • Computational Structural Engineering
    • /
    • v.7 no.4
    • /
    • pp.137-144
    • /
    • 1994
  • As for the safety evaluation of existing large-scale structures, methods for the estimation of structural and dynamic properties are studied. Sequential prediction error method in time domain and frequency response function estimators in frequency domain are examined. For this purpose, impact tests are performed on a steel frame structure with 2 bays and 3 floors. Results from both methods are found to be consistent to each others. However those from the finite-element analysis are slightly different from the experimental results. The discrepancies may be caused by the improper modeling of the complex behavior at the connection joints of the model structure.

  • PDF

AN EXPERIMENTAL STUDY ON TRACHEAL RECONSTRUCTION USING RIB CARTILAGE AND PERICHONDRIUM IN RABBITS (가토의 자가 늑연골 및 늑연골막을 이용한 기관재건술에 대한 실험적 연구)

  • 채우석;김경래;이형석;안경성;김선곤
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1991.06a
    • /
    • pp.24-24
    • /
    • 1991
  • 기관협착증은 이비인후과 영역에 있어서 치료가 어려운 질환중의 하나로 이의 재건에는 여러가지 자가조직이 각각의 장점에 따라 사용되어 왔지만 완전하고 만족할만한 결과를 얻지 못하는 실정이다. 저자들은 가토의 자가 늑연골 (1군) 및 늑연골막 (2군)을 이용한 기관 재건술을 시행하여 다음과 같은 결과를 얻었다. 1) 이식편은 술후 10주 (1군) 및 12주 (2군)에 흡수나 섬유조직으로의 대치는 없었으며, 기관강의 크기는 직상 하부의 정상기관과 큰 차이가 없었다. 2) 늑연골을 이식한 부위는 연골막의 내세포층에서 연골세포가 분화, 이동되어 절단된 연골사이로 이동하여 새로운 연골을 형성하였다. 3) 늑연골막을 이식한 부위는 연골막에서 형성된 연골세포 및 연골기질이 절단된 연골사이로 이동하여 새로운 연골을 형성하였다. 4)) 이식한 부위의 점막층은 점막재생이 이루어져 원주상피로 피복되었다. 5) 기관 전벽의 결손부위는 늑연골 및 늑연골막을 이용하여 성공적으로 재건되었다.

  • PDF

An adaptive control scheme of streaming video in smart agent AP for DASH (DASH를 위한 무선 스마트 에이전트의 적응적 비디오 품질 조절 방법)

  • Oh, Gyu-Tae;Lee, Yoo-Nyeong;Lee, hyung-keun
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2014.11a
    • /
    • pp.115-117
    • /
    • 2014
  • 본 논문에서는 MPEG 표준인 DASH 서비스를 DASH 표준이 나오기 이전에 출시된 기존 단말들에게 무선 랜 환경에서 DASH를 위한 비디오 스트리밍 서비스를 제공해 주기 위한 무선 스마트 에이전트의 적응적 비디오 품질 조절 방법을 제안한다. 기존 연구는 스마트 에이전트가 클라이언트의 네트워크 상황을 파악하기 위해 전송 계층의 정보를 이용하기 때문에 무선 랜 환경에서 페이딩이나 간섭 등과 같은 이유로 적합하지 않다. 본 논문에서 제안하는 방법은 802.11 MAC 부계층에서 얻을 수 있는 정보를 이용하여 급격히 변하는 각 클라이언트의 상황을 빠르게 파악하여 무선 채널의 상태를 적응적으로 비디오 스트리밍하여 전달하도록 한다. 제안하는 방법의 실험을 통하여 DASH 표준 서비스를 제공 받는 클라이언트처럼 네트워크 상황에 적응적으로 비디오 스트리밍 되는 것을 확인하였다. 또한, 클라이언트의 이동성과 무선 채널의 에러를 추가함으로써 급격히 변하는 네트워크의 상황에도 적응적으로 클라이언트에게 비디오 스트리밍을 제공하는 것을 확인하였다.

  • PDF

A Study on the Analysis of the Relaxation Area and the Improvement Effect of the Ground by Road Subsidence (지하연속벽 배면 도로의 지반침하에 따른 이완영역분석방법과 지반 보강 효과검증에 관한 연구)

  • Lee, Hyoung Kyu;Lee, Yong-Sun
    • Journal of the Korean Geotechnical Society
    • /
    • v.37 no.1
    • /
    • pp.29-41
    • /
    • 2021
  • Although underground works are essential to use underground spaces in urban areas efficiently, various damages caused by constructions have often occurred, making them major social problems. Since 2018, it is stipulated in the Special Act on Underground Safety Management that appropriate construction methods must be used in the design stage to prevent various damage cases. This Special Act includes establishing an area subject to underground safety impact assessment, analysis of ground and geological status, review of effects caused by changes in groundwater, review of ground safety, and establishment of measures to secure underground safety. This study area consists of various strata in order of landfill, sedimentary silt, sedimentary sand, sedimentary gravel, weathering zone, and foundation rock. Also, the slurry wall, a highly rigid underground continuous wall, was chosen as a construction method to consider high water table distribution and minimize the influence of the surroundings in this area. However, ground subsidence occurred on the road nearby in December 2019 due to the inflow of loosening soil to the construction area. Thus, several types of site investigations were conducted to suggest an appropriate analysis method and to find out loosed ground behavior and its area for the subsided site. As a result, new design soil properties were re-calculated, and the reinforcement measures were proposed through analytical verification.